| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC | ₹8.1 L Quoted ₹8.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹9.1 LRejected-Finance | ₹9.1 L | L2 | Rejected-Finance Highest Amount Quoted |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Not Recommended. As refer of HQ Chief Engineer Jodhpur Zone letter No 800000/WLR/379/E8 dated 30 Jan 2026. |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Not Recommended. As refer of HQ Chief Engineer Jodhpur Zone letter No 800000/WLR/379/E8 dated 30 Jan 2026. |
| Sl No | Description | Qty | Unit | L AND J CONSTRUCTION CO. L1 | M/s SUNIL ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone masonary, precast cement concrete walling built in cement mortar including all quoins, arches, pillars etc., complete with removal of debris all as specified. | 5 | Cum | 300 ₹1,500 | 300 ₹1,500 |
| 2.00 | Material and labour for brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6), complete all as specified and directed. | 5 | Cum | 4,000 ₹20,000 | 5,000 ₹25,000 |
| 3.00 | Material and Labour for PCC 1:2:4 type B-0 using (12.5 mm graded stone aggregate) as levelling coarse/benching rounded or chamfered on top and edges of brick work complete all as specified and directed. | 2.5 | Cum | 2,500 ₹6,250 | 4,500 ₹11,250 |
| 4.00 | Demolition of RCC water tank external capacity 300 to 500 ltrs on roof top of any storey bldgs and removed debris from site upto 1.50 Km as directed by Engr-in-Charge. | 20 | Each Job | 250 ₹5,000 | 400 ₹8,000 |
| 5.00 | M&L for cleaning of PVC/GI water storage tank including removing all scales, dirt etc from tank and from the mouth of circulating pipe, not exc 500 Ltr capacity each complete all as specified and directed. | 850 | Each | 150 ₹1.3 L | 110 ₹93,500 |
| 6.00 | M&L for cleaning of PVC/GI water storage tank including removing all scales, dirt etc from tank and from the mouth of circulating pipe, not exc 1000 Ltr capacity each complete all as specified and directed. | 350 | Each | 180 ₹63,000 | 140 ₹49,000 |
| 7.00 | S&F rotational molded polyethylene water storage tanks white tripple layered (cylindrical vertical with closed top) capacity 500 Ltr hoisted and fixed in position including taking down of existing tank all as specified and directed by Engr-in-charge. | 70 | Each | 3,500 ₹2.5 L | 4,650 ₹3.3 L |
| 8.00 | S&F rotational molded polyethylene water storage tanks white tripple layered (cylindrical vertical with closed top) capacity 1000 Ltr hoisted and fixed in position including taking down of existing tank all as specified and directed by Engr-in-charge. | 35 | Each | 7,500 ₹2.6 L | 7,150 ₹2.5 L |
| 9.00 | S&F in repair PTMT ball valves high pressure with epoxy coated aluminium rod & high density plastic ball screwed for 20mm bore pipes all as specified and directed by Engr-in-charge. | 105 | Each | 250 ₹26,250 | 200 ₹21,000 |
| 10.00 | S&F in repair of 15mm Nipple suitable for PVC water tank hoisted and fixed in position all as specified and directed by Engr-in-charge. | 105 | Each | 100 ₹10,500 | 55 ₹5,775 |
Updated dates
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
9 Apr 2026, 6:00 pmClosed
AGE I UDAIPUR
ASST. GARRISON ENGINEER (I) EKLINGGARH CANTT, UDAIPUR (RAJ.) - 313001
REPLACEMENT AND CLEANING OF WATER STORAGE TANK AT MIL STN UDAIPUR
2026_MES_756353_1
8030/E8 AGE I Udaipur
Open Tender
Civil Works
270 days
ARMY AREA UDAIPUR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
AGE I UDAIPUR
₹17,000
Yes
9 Jun 2026
14 Mar 2026
13 Apr 2026
14 Mar 2026
9 Apr 2026
27 Mar 2026
Demolition of brick work or stone masonary, precast cement concrete walling built in cement mortar including all quoins, arches, pillars etc., complete with removal of debris all as specified.
Material and labour for brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6), complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B-0 using (12.5 mm graded stone aggregate) as levelling coarse/benching rounded or chamfered on top and edges of brick work complete all as specified and directed.
Demolition of RCC water tank external capacity 300 to 500 ltrs on roof top of any storey bldgs and removed debris from site upto 1.50 Km as directed by Engr-in-Charge.
M&L for cleaning of PVC/GI water storage tank including removing all scales, dirt etc from tank and from the mouth of circulating pipe, not exc 500 Ltr capacity each complete all as specified and directed.
M&L for cleaning of PVC/GI water storage tank including removing all scales, dirt etc from tank and from the mouth of circulating pipe, not exc 1000 Ltr capacity each complete all as specified and directed.
S&F rotational molded polyethylene water storage tanks white tripple layered (cylindrical vertical with closed top) capacity 500 Ltr hoisted and fixed in position including taking down of existing tank all as specified and directed by Engr-in-charge.
S&F rotational molded polyethylene water storage tanks white tripple layered (cylindrical vertical with closed top) capacity 1000 Ltr hoisted and fixed in position including taking down of existing tank all as specified and directed by Engr-in-charge.
S&F in repair PTMT ball valves high pressure with epoxy coated aluminium rod & high density plastic ball screwed for 20mm bore pipes all as specified and directed by Engr-in-charge.
S&F in repair of 15mm Nipple suitable for PVC water tank hoisted and fixed in position all as specified and directed by Engr-in-charge.
S&F in repair of 20mm Nipple suitable for PVC water tank hoisted and fixed in position all as specified and directed by Engr-in-charge.
Supply & Fixing in repairs 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
Taking up or down 15mm dia steel tubing and connections by disconnecting fittings/tubing from existing tubing were required including cleaning for refixing or removal from site complete all as specified and directed.
Taking up or down 20 mm dia steel tubing and connections by disconnecting fittings/tubing from existing tubing were required including cleaning for refixing or removal from site complete all as specified and directed.
Supply & fixing GI tubing medium grade 15mm dia incl fittings, cutting threading and fixing to walls or fixing in concealed walls or in floors etc, and making good the surfaces matching to exsiting surafaces of walls/ floor to the entire satisfaction of Engineer-in-charge.
Supply & fixing GI tubing medium grade 20mm dia incl fittings, cutting threading and fixing to walls or fixing in concealed walls or in floors etc, and making good the surfaces matching to exsiting surafaces of walls/ floor to the entire satisfaction of Engineer-in-charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
tender8030.pdf
Tender Documents • 0.60 MB
splcon8030.pdf
Tender Documents • 0.83 MB
BOQ_847220.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid