Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC AT BALU BANKER COLONY PO DHORI BERMO DIST BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | Rejected-Technical 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | - | Rejected-Technical Bid not be opened as per NIT terms | |
| 3 | Rejected-Technical AT KARGALI BAZAR BERMO DIST BOKARO PIN NO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical Bid not be opened as per NIT terms |
Tender Value
₹30.3 L
EMD Value
₹37,900
Closing Date
28 Sept 2024, 9:00 amClosed
Staff Officer (EnM)
Office of the General Manager, Dhori Area
Repair and maintenance of 11 kV HT feeder (feeder no. 3 and 4) from main regional substation (MRSS) to Dhori Old Checkpost sub-station under MRSS, GM Unit, Dhori area for a route length of 5.5 km approx and 3.0 km approx respectively
2024_CCL_317543_1
GM(D)/SO(EnM)/DA/2024-25/35
Open Tender
Electrical and Maintenance Works
Item Wise
60 days
GM Unit, Dhori Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹37,900
4 Nov 2024
16 Sept 2024
30 Sept 2024
17 Sept 2024
28 Sept 2024
17 Sept 2024
17 Sept 2024 - 20 Sept 2024
Amount
Part A: Feeder No.3
Erection of steel tubular pole or rail pole strut in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. 12x4=48 +20 for total O.H.Line
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. 4x6=24 +30, For total Overhead Line
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. (8 stay for new DP and 10 for total OH line)
Supplying of two length of channel iron 75 mm x 40 mm x 6 mm (7.14 kg / mtr ) double pole cross arm for three wire 11 KV OH line conductor complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm MS flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arm together, including drilling holes for insulator pins, bolts nuts and washers etc (as per drawing) and painting with primer and finish paint as requied. (8 Set for GOS and 4 set for total OH line)
Erection of double pole 3 wire cross arm for 11 KV over head lines as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/channel iron, cross arm on steel tubular/ rail/ PCC pole for 11 KV as required.
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required - Dog Conductor
Dismantling of overhead lines comprising of aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Providing of 11 kV, 400 A Male contact Blade suitable for Double Break GOS
Providing of 11 kV, 400 A Female contact Blade suitable for Double Break GOS
Repairing of 400 Amps, 11KV grade GOS after dismantling of burnt/defective one phase Male & Female fixed contact, copper wirenet - 1.5 mtr, moving contact etc and replace from the materials along setting it on the pole structure
Supply of 6 SWG G.I. wire.
Erection of G.I. wire no 8 SWG includig binding etc as required.
Erection of cradle guard as required.
Providing of 10 mm X 25 mm long GI bolt with nut etc
Dismantling of pole in cement concrete foundation etc. as required
Shifting of dismantled pole from one site/workshop/substation to another site
Supply and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size 3 core XLPE aluminium conductor cable of 11KV grade as required - 120 sq. mm
Fixing of new 11KV grade onload Gang Operating Switch after dismantling of old GOS
Clamps, bolts nuts etc.
Providing & fixing of 11KV grade post insulator for GOS
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal coke and salt as required.
Providing and fixing of 25 mm x 5 mm GI strip on surface or in recess for connections etc as required
Supply and providing cable hanger made by angle with double clamp with nuts and bolts including fitting and fixing on pole for cable.
Lettering with black Japan paint of approved brand and manufacture for Numbering of poles.
Appling priming coat : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)/steel works
Painting with aluminium paint of approved brand and manufacture to give an even shade - Two coats.
Part B: Feeder No.4
Erection of steel tubular pole or rail pole strut in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. 12x2=24 +24 for total O.H.Line
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. 12 for breaker
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supplying of two length of channel iron 75 mm x 40 mm x 6 mm (7.14 kg / mtr ) double pole cross arm for three wire 11 KV OH line conductor complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm MS flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arm together, including drilling holes for insulator pins, bolts nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11 KV over head lines as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. 2 for OH line and 2 for supporting bracket )
Erection of pole top/ straight two wire/ V shape two wire, angle iron/channel iron, cross arm on steel tubular/ rail/ PCC pole for 11 KV as required.
Supplying and erection of a set of cross bracing FRLSame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required - Dog Conductor
Dismantling of overhead lines comprising of aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Providing of 11 kV, 400 A Male contact Blade suitable for Double Break GOS (3 set GOS)
Providing of 11 kV, 400 A Female contact Blade suitable for Double Break GOS( 3 Set GOS )
Repairing of 400 Amps, 11KV grade GOS after dismantling of burnt/defective one phase Male & Female fixed contact, copper wirenet - 1.5 mtr, moving contact etc and replace from the materials along setting it on the pole structure
Supply of 6 SWG G.I. wire.
Erection of G.I. wire no 8 SWG includig binding etc as required.
Erection of cradle guard as required.
Providing of 10 mm X 25 mm long GI bolt with nut etc
Dismantling of pole in cement concrete foundation etc. as required
Shifting of dismantled pole from one site/workshop/substation to another site
Supply and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size 3 core XLPE aluminium conductor cable of 11KV grade as required - 120 sq. mm
Fixing of new 11KV grade onload Gang Operating Switch after dismantling of old GOS (GOS departmental supply)
Clamps, bolts nuts etc.
Providing & fixing of 11KV grade post insulator for GOS
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal coke and salt as required.
Providing and fixing of 25 mm x 5 mm GI strip on surface or in recess for connections etc as required
Supply and providing cable hanger made by angle with double clamp with nuts and bolts including fitting and fixing on pole for cable.
Total impact of GST for the purpose of CTC
M/S KUMAR ENTERPRISES
M/S SHIV PARBATI ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .