Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LQualified DIMAPUR NAGALAND 797112 UDYAM NL 01 0004111 | DIMAPUR | NAGALAND | 797112 | ₹11.8 L | L1 | Qualified MSE, MII, Category: General |
| 2 | L2₹16.9 LQualified H NO 11 L K COMPLEX KOHIMA ROAD BANK COLONY DIMAPUR NAGALAND 797112 | DIMAPUR | NAGALAND | 797112 | ₹16.9 L | L2 | Qualified MII |
Tender Value
₹16.2 L
EMD Value
₹32,447
Closing Date
21 Feb 2026, 6:00 pmClosed
Transportation of distribution transformer up to 3 phase 63 kVA to a following specified distance 0 TO 60 kM
Transportation of distribution transformer up to 3 phase 63 kVA to a following specified distance 61 TO 180 Km
Transportation of transformer up to 3 phase 63 kVA to a following specified distance 181 TO 350 kM
Arrangement of repaired and refurbished 3 Ph upto 63 kVA similar to the faulty 0 TO 25 kVA 11kV 440V Transformer
Arrangement of repaired and refurbished 3 Ph transformer upto 63 kVA similar to the faulty 26KVA-63 kVA 11kV 440V Transformer
Supplying and erection of three piece nonlinear resistor type lightning arrestor
Supplying and erection of 11 KV pin insulator complete with large steel head G I pin nuts washers etc as required
Supplying and erection 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings
11 KV triple pole 200 A rating A B Switch suitable for vertical mounting with three 11 kV Polymeric Insulator on 75 by 40 mm M S Channels
Transformer oil HV grade with suitable di electric strength and should comply with the requirements of Type II Insulating Oil as per IS 335 2018
Supplying and Laying of 2 core 16 Sqmm WPTC PVC insulated and PVC sheathed Aluminium Cable including providing 8 SWG GI wire
Providing Earthing with G I earth plate of 600 mm 600 mm 6 mm thick including accessories and providing masonry enclosure
Providing and fixing 25 mm 5 mm G I strip in 40 mm dia G I pipe from earth electrode including connection with G I nut bolt spring washer
Providing and fixing 25 mm 5 mm G I strip on surface or in recess for connections etc as required
Supplying and laying of 40 mm dia PVC pipe for LA strip etc as required
8945450
GEM/2026/B/7203568
Two Packet Bid
Transportation of distribution transformer up to 3 phase 63 kVA to a following specified distance 0
Nagaland; Dimapur
Total value wise evaluation
BOQ
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Transportation of distribution transformer up to 3 phase 63 kVA to a | - | HSN not specified by seller | 3 Jobs | 16,500 | 49,500 |
| Transportation of distribution transformer up to 3 phase 63 kVA to a | - | HSN not specified by seller | 4 Jobs | 22,000 | 88,000 |
| Transportation of transformer up to 3 phase 63 kVA to a following | - | HSN not specified by seller | 8 Jobs | 27,000 | 216,000 |
| Arrangement of repaired and refurbished 3 Ph upto 63 kVA similar to | - | HSN not specified by seller | 10 Jobs | 32,500 | 325,000 |
| Arrangement of repaired and refurbished 3 Ph transformer upto 63 kVA | - | HSN not specified by seller | 5 Jobs | 46,000 | 230,000 |
| Supplying and erection of three piece nonlinear resistor type lightning | - | HSN not specified by seller | 10 Sets | 2,600 | 26,000 |
| Supplying and erection of 11 KV pin insulator complete with large steel | - | HSN not specified by seller | 12 Sets | 600 | 7,200 |
| Supplying and erection 11 KV disc insulator for 11 KV over head lines | - | HSN not specified by seller | 12 Sets | 1,200 | 14,400 |
| 11 KV triple pole 200 A rating A B Switch suitable for vertical mounting | - | HSN not specified by seller | 5 Sets | 17,000 | 85,000 |
| Transformer oil HV grade with suitable di electric strength and should | - | HSN not specified by seller | 500 Ltrs | 152 | 76,000 |
| Supplying and Laying of 2 core 16 Sqmm WPTC PVC insulated and PVC | - | HSN not specified by seller | 200 Mtrs | 130 | 26,000 |
| Providing Earthing with G I earth plate of 600 mm 600 mm 6 mm thick | - | HSN not specified by seller | 6 Sets | 4,000 | 24,000 |
| Providing and fixing 25 mm 5 mm G I strip in 40 mm dia G I pipe from | - | HSN not specified by seller | 18 Mtrs | 610 | 10,980 |
| Providing and fixing 25 mm 5 mm G I strip on surface or in recess for | - | HSN not specified by seller | 18 Mtrs | 230 | 4,140 |
| Supplying and laying of 40 mm dia PVC pipe for LA strip etc as required | - | HSN not specified by seller | 15 Mtrs | 130 | 1,950 |
6 documents required · 6 mandatory
3 yrs
₹5 L
₹5 L
80%
Accounts Officer Cash, NE2 Circle, Department of Telecommunications (DOT), Bharat Sanchar Nigam Limited Portal(BSNL), Ministry of, Communications, (Accounts Officer Cash Bsnl Dimapur), 3/17
₹32,447
27 Apr 2026
6 Feb 2026
21 Feb 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Transportation of distribution transformer up to 3 phase 63 kVA to a following specified distance 0 TO 60 kM | Transportation of repaired refurbished distribution transformer up to 3phase 63 kVA to a following specified distance inclusive of dismantling the existing faulty distribution transformer from the DP structure by disconnecting the HT conductors and LT cable utilizing chain pulley and manual labour Firmly installing the repaired refurbished distribution transformer onto the DP structure including loading and unloading reconnecting the HT conductor and LT cable changing lugs if necessary and conducting testing and commissioning as required
Note 1 To and fro transportation of burnt and replaced transformer is included in the rate
Note 2 The agency may collect the faulty transformer
0 TO 60 kM | 3 | Jobs | Umakanta Kar 797112,O/othe GMTD BSNL Dimapur-797112 Nagaland | 365 |
| 2 | Transportation of distribution transformer up to 3 phase 63 kVA to a following specified distance 61 TO 180 Km | Transportation of repaired refurbished distribution transformer up to 3phase 63 kVA to a following specified distance inclusive of dismantling the existing faulty distribution transformer from the DP structure by disconnecting the HT conductors and LT cable utilizing chain pulley and manual labour Firmly installing the repaired refurbished distribution transformer onto the DP structure including loading and unloading reconnecting the HT conductor and LT cable changing lugs if necessary and conducting testing and commissioning as required
Note 1 To and fro transportation of burnt and replaced transformer is included in the rate
Note 2 The agency may collect the faulty transformer
61 TO 180 kM | 4 | Jobs | Umakanta Kar 797112,O/othe GMTD BSNL Dimapur-797112 Nagaland | 365 |
| 3 | Transportation of transformer up to 3 phase 63 kVA to a following specified distance 181 TO 350 kM | Transportation of repaired refurbished distribution transformer up to 3phase 63 kVA to a following specified distance inclusive of dismantling the existing faulty distribution transformer from the DP structure by disconnecting the HT conductors and LT cable utilizing chain pulley and manual labour Firmly installing the repaired refurbished distribution transformer onto the DP structure including loading and unloading reconnecting the HT conductor and LT cable changing lugs if necessary and conducting testing and commissioning as required
Note 1 To and fro transportation of burnt and replaced transformer is included in the rate
Note 2 The agency may collect the faulty transformer
181 TO 350 kM | 8 | Jobs | Umakanta Kar 797112,O/othe GMTD BSNL Dimapur-797112 Nagaland | 365 |
| 4 | Arrangement of repaired and refurbished 3 Ph upto 63 kVA similar to the faulty 0 TO 25 kVA 11kV 440V Transformer | Arrangement of repaired refurbished 3 Ph distribution transformer upto 63 kVA similar to the faulty transformer of same capacity and same winding materials with full quantity of transformer oil properly tested for winding resistance insulation temparature raise ratio OC and SC tests ic checking of leakages bushing terminal etc complete as required as below
Note
1 Firm should provide one year warrenty of the replaced transformer
2 Test results should be submitted to engineer in charge before installation.
3 Liasoning with DOPN authority for HT Line clearance is agencies responsibility
4 The faulty transformer shall be tested for winding failure burnt in presence of site incharge JTO SDE
0 TO 25 kVA 11kV 440V Transformer | 10 | Jobs | Umakanta Kar 797112,O/othe GMTD BSNL Dimapur-797112 Nagaland | 365 |
| 5 | Arrangement of repaired and refurbished 3 Ph transformer upto 63 kVA similar to the faulty 26KVA-63 kVA 11kV 440V Transformer | Arrangement of repaired refurbished 3 Ph distribution transformer upto 63 kVA similar to the faulty transformer of same capacity and same winding materials with full quantity of transformer oil properly tested for winding resistance insulation temparature raise ratio OC and SC tests ic checking of leakages bushing terminal etc complete as required as below
Note
1 Firm should provide one year warrenty of the replaced transformer
2 Test results should be submitted to engineer in charge before installation.
3 Liasoning with DOPN authority for HT Line clearance is agencies responsibility
4 The faulty transformer shall be tested for winding failure burnt in presence of site incharge JTO SDE
26KVA-63 kVA 11kV 440V Transformer | 5 | Jobs | Umakanta Kar 797112,O/othe GMTD BSNL Dimapur-797112 Nagaland | 365 |
| 6 | Supplying and erection of three piece nonlinear resistor type lightning arrestor | Attending break down faults of 11KV 415 Volts transformer up to 63 KVA including replacement of any spares mentioned below including supplying fixing testing etc complete as reqd
Note Liasoning with DOPN authority for HT shutdown disconnection reconnection charges if any is agencies responsibility
A Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire 11 KV overhead lines with rated voltage 9 KV rms with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement G I bolts nuts washers etc as required | 10 | Sets | Umakanta Kar 797112,O/othe GMTD BSNL Dimapur-797112 Nagaland | 365 |
| 7 | Supplying and erection of 11 KV pin insulator complete with large steel head G I pin nuts washers etc as required | Attending break down faults of 11KV 415 Volts transformer up to 63 KVA including replacement of any spares mentioned below including supplying fixing testing etc complete as reqd
Note Liasoning with DOPN authority for HT shutdown disconnection reconnection charges if any is agencies responsibility
B Supplying and erection of 11 KV pin insulator complete with large steel head G I pin nuts washers etc as required | 12 | Sets | Umakanta Kar 797112,O/othe GMTD BSNL Dimapur-797112 Nagaland | 365 |
| 8 | Supplying and erection 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings | Attending break down faults of 11KV 415 Volts transformer up to 63 KVA including replacement of any spares mentioned below including supplying fixing testing etc complete as reqd
Note Liasoning with DOPN authority for HT shutdown disconnection reconnection charges if any is agencies responsibility
C Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings ball and socket type and complete with galvanised strain clamps bolts nuts washers etc as required | 12 | Sets | Umakanta Kar 797112,O/othe GMTD BSNL Dimapur-797112 Nagaland | 365 |
| 9 | 11 KV triple pole 200 A rating A B Switch suitable for vertical mounting with three 11 kV Polymeric Insulator on 75 by 40 mm M S Channels | Attending break down faults of 11KV 415 Volts transformer up to 63 KVA including replacement of any spares mentioned below including supplying fixing testing etc complete as reqd
Note Liasoning with DOPN authority for HT shutdown disconnection reconnection charges if any is agencies responsibility
D 11 KV triple pole 200 A rating A B Switch suitable for vertical mounting with three 11 kV Polymeric Insulator having 320 CD mounted on 75 by 40 mm M S Channels having manually operated with a locking type arrangement through coupling rod and suitable size G I Pipe with operating handle etc as required | 5 | Sets | Umakanta Kar Transformer Oil HV Grade 797112,O/othe GMTD BSNL Dimapur-797112 Nagaland With Suitable Di Electric | 365 |
| 10 | Transformer oil HV grade with suitable di electric strength and should comply with the requirements of Type II Insulating Oil as per IS 335 2018 | Attending break down faults of 11KV 415 Volts transformer up to 63 KVA including replacement of any spares mentioned below including supplying fixing testing etc complete as reqd
Note Liasoning with DOPN authority for HT shutdown disconnection reconnection charges if any is agencies responsibility
E Transformer oil HV grade with suitable di electric strength and should comply with the requirements of Type II Insulating Oil as per IS 335 2018 | 500 | Ltrs | Umakanta Kar 797112,O/othe GMTD BSNL Dimapur-797112 Nagaland | 365 |
contract_GEMC-511687770907230.pdf
GEM_CONTRACT • 0.13 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_8945450.pdf
GEM_BID
atc_rc_for_transformers_nld_ba-docx_2026-02-06-16-30-35_0cd96fb3d47a992511b939b2aaf551c2.pdf
BOQ
boqtrtender_2026-02-06-16-30-35_43a38213c374b2af229dbdc11e88fb40.csv
BOQ
1770376740.pdf
OTHER
ATCRCDTR_8aa4076d-5b26-431b-8e4f1770377632223_EE_E_NE2.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
1770376740.pdf
GEM_OTHER
ATCRCDTR_8aa4076d-5b26-431b-8e4f1770377632223_EE_E_NE2.pdf
GEM_OTHER • 1.59 MB
list-of-categories-where-trials-are-allowed_1712126171.pdf
GEM_OTHER • 0.52 MB
gtc.pdf
GEM_OTHER • 0.70 MB
Download all tender documents and submit your bid