Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-Finance Lowest | |
| 2 | L2₹54.0 L+₹13.0 L (31.8%)Accepted-Finance | L2 | Accepted-Finance Other then lowest | |
| 3 | L3₹56.0 L+₹15.0 L (36.6%)Accepted-Finance NOT FOUND | L3 | Accepted-Finance Other then lowest | |
| 4 | L4₹65.2 L+₹24.2 L (59.1%)Accepted-Finance | L4 | Accepted-Finance Other then lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Feb 2022, 6:00 pmClosed
Major Auronee Das GE (Utility) Chandimandir
GE (Utility) Chandimandir
GE(U)/CHM-47/2021-22 PROVN OF LT UNDERGROUND CABLES AND LT PANELS INCLUDING REPLACEMENT OF OLD BUS BAR LT SUPPLY DISTRIBUTION SYSTEM WITH UG CABLES OF CERTAIN ACCN AT CHANDIMANDIR CANTT
2021_MES_492562_2
GE(U)/CHM-47/2021-22
Open Tender
Miscellaneous Works
Item Rate
210 days
Chandimandir Cantt
Please refer as per Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE (Utility) Chandimandir
₹90,000
Yes
26 Feb 2022
25 Jan 2022
22 Feb 2022
25 Jan 2022
15 Feb 2022
1 Feb 2022
Amount
Supply, laying , jointing, testing and commissioning LT electric cable, XLPE insulated PVC sheathed, armoured, heavy duty 1100 volts grade, multistranded aluminum conductor, laid in existing ducts, complete all as specified and as directed of size :-
630 Sqmm 3.50 core
400 Sqmm 3.50 core
240 Sqmm 3.50 core
185 Sqmm 3.50 core
150 Sqmm 3.50 core
Supply, laying/fixing, jointing, testing and commissioning LT electric cable, XLPE insulated PVC sheathed, armoured, heavy duty 1100 volts grade, multistranded aluminum conductor, laid in existing ducts or fixed to walls upto a height of 30.00 metre (maximum) with appropriate/suitable size clamps/hooks, as approved by Engr-in-Charge, complete all as specified and as directed of size :- NOTE :- (i) Appropriate / suitable size clamps/hooks, as approved by Engr-in-Charge shall be measured and paid for separately. (ii) Cutting hole for fixing clamps / hooks and making good shall be measured and paid for separately.
120 Sqmm 3.50 core
70 Sqmm 4.00 core
50 Sqmm 4.00 core
Cutting holes in brick work / RCC wall upto a height of 30.00 metre (Maximum) of size 10 cm x 10 cm x 10cm and filling with cement concrete 1:2:4 type B.O, after fixing the clamp and making good to match with existing finish complete all as specified and as directed.
Mild steel work in clamps, hooks, stays, made to shape and size as directed and fitted in position, including nuts, bolts and washers as required complete all as specified and as directed.
Supply, installation, testing and commissioning of out door type LT Panel factory made, CPRI approved, openable from front & rear, double door type, dust and vermin proof, fabricated out of 3.15 mm CRCA sheet duly powder coated of approved shade over a coat of zinc chrome primer, 4 Nos heat shrink insulated bus bar of 1.5 times rating of incoming MCCB including all connections with aluminium strip pillar board provided with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connections with new lugs, glands to be provided at cable entries, including , MS channel frame of ISMC 75 at base of panel only and 04 Nos legs of not less than 75 cm long each below the base of panel made of angle iron 50 x 5 0 x 6 mm for grouting purpose and grouted in PCC 1:2:4 type B1( using 20 mm graded stone aggregate) complete all as specified and directed by Engr-in- charge and comprising of following accessories:-
(A) INCOMING:- (a) ACB, 415 Volts, 50 HZ, four pole 630 Amps, EDO Type, microprocessor based breaking capacity 52 KA, IEC - 60947, EN - 60947 double insulation = 01 No (B) OUTGOING :- (a) MCCB four pole 415 Volts ,50 HZ, 125 Amps adjustable thermal and adjustable magnetic protection release breaking capacity 25 KA with Ics = 100% Icu=06 Nos (b) MCCB four pole 415 Volts ,50 HZ, 160 Amps adjustable thermal and adjustable magnetic protection release breaking capacity 25 KA with Ics =100% Icu = 02 Nos (c) MCCB four pole 415 Volts ,50 HZ, 200 Amps adjustable thermal and adjustable magnetic protection release breaking capacity 36 KA with Ics = 100%Icu= 01 No (d) Phase indicator lamp complete with copper control wiring and suitable size of CT complete = 01 (Set of three) (e) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed.
Supply, installation, testing and commissioning of out door type LT Panel factory made, CPRI approved, openable from front & rear, double door type, dust and vermin proof, fabricated out of 3.15 mm CRCA sheet duly powder coated of approved shade over a coat of zinc chrome primer, 4 Nos heat shrink insulated bus bar of 1.5 times rating of incoming MCCB including all connections with aluminium strip pillar board provided with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connections with new lugs, glands to be provided at cable entries, including , MS channel frame of ISMC 75 at base of panel only and 04 Nos legs of not less than 75 cm long each below the base of panel made of angle iron 50 x 5 0 x 6 mm for grouting purpose and grouted in PCC 1:2:4 type B1( using 20 mm graded stone aggregate) complete all as specified and directed by Engr-in- charge and comprising of following accessories:-
(A) INCOMING :- (a) ACB, 415 Volts, 50 HZ, four pole 1000 Amps, EDO Type, microprocessor based breaking capacity 52 KA, IEC - 60947, EN - 60947 double insulation = 01 No. (B) OUT GOING :- (a) MCCB four pole 415 Volts ,50 HZ, 125 Amps adjustable thermal and adjustable magnetic protection release breaking capacity 25 KA with Ics = 100% Icu=02 Nos (b) MCCB four pole 415 Volts ,50 HZ, 250 Amps adjustable thermal and adjustable magnetic protection release breaking capacity 36 KA with Ics = 100% Icu= 03 Nos (c) MCCB four pole 415 Volts ,50 HZ, 320 Amps adjustable thermal and adjustable magnetic protection release breaking capacity 36 KA with Ics = 100% Icu= 01 No (d) MCCB four pole 415 Volts ,50 HZ, 160 Amps adjustable thermal and adjustable magnetic protection release breaking capacity 25 KA with Ics = 100% Icu= 02 Nos (e) Phase indicator lamp complete with copper control wiring and suitable size of CT complete = 01 (Set of three). (f) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed.
Supply, installation, testing and commissioning of out door type LT Panel factory made, CPRI approved, openable from front & rear, double door type, dust and vermin proof, fabricated out of 3.15 mm CRCA sheet duly powder coated of approved shade over a coat of zinc chrome primer, 4 Nos heat shrink insulated bus bar of 1.5 times rating of incoming MCCB including all connections with aluminium strip pillar board provided with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connections with new lugs, glands to be provided at cable entries, including , MS channel frame of ISMC 75 at base of panel only and 04 Nos legs of not less than 75 cm long each below the base of panel made of angle iron 50 x 5 0 x 6 mm for grouting purpose and grouted in PCC 1:2:4 type B1( using 20 mm graded stone aggregate) complete all as specified and directed by Engr-in- charge and comprising of following accessories:-
(A) INCOMING :- (a) ACB, 415 Volts, 50 HZ, four pole 1000 Amp, EDO Type, microprocessor based breaking capacity 52 KA, IEC - 60947, EN - 60947 double insulation = 01 No (B) OUT GOING :- (a) MCCB four pole 415 Volts ,50 HZ, 125 Amps adjustable thermal and adjustable magnetic protection release breaking capacity 25 KA with Ics = 100% Icu=02 Nos (b) MCCB four pole 415 Volts ,50 HZ, 250 Amps adjustable thermal and adjustable magnetic protection release breaking capacity 36 KA with Ics = 100% Icu=07 Nos (c) MCCB four pole 415 Volts ,50 HZ, 320 Amps adjustable thermal and adjustable magnetic protection release breaking capacity 36 KA with Ics = 100% Icu=02 Nos (d) MCCB four pole 415 Volts ,50 HZ, 160 Amps adjustable thermal and adjustable magnetic protection release breaking capacity 25 KA with Ics = 100% Icu=02 Nos (e) Phase indicator lamp complete with copper control wiring and suitable size of CT complete = 01 (Set of three) (f) Digital type multi meter LCD display complete for Volt meter and ammeter of size 96 x 96 mm complete all as specified and directed.
Earthing complete with galvanized iron or steel plate electrode 600mm X600mm X 6.0 mm burried directly in ground vertially in a pit of depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth of not less than 1.50m below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to with and including GI/ Steel strip of size 32mmx6mm upto a length of 7.50 metre by means of bolts, nuts, check nuts & washers of galvanized iron /steel, earth strip protected by and including galvanized steel pipe light grade of bore 40 mm (internal dia) & connected to main control board / switch board or any other electrical equipment complete all as shown in electrical plate No : 3 MES SSR including necessary excavation & earth work, disposal of surplus soil not exceeding 50m, in any type of soil. (The rate also includes for cost of charcoal & salt in alternate layers of 15 cm thickness, 20 mm bore internal dia GI/steel pipe light grade) for watering, funnel, wire mesh, PCC chamber in cement concrete (1:3:6) type C-1, 40mm thick RCC(1:2:4) type B-0, reinforced with XPM of weight not less than 4.00 kg/Sqm and mild steel frame of angle 50mmx50xxx6mm and testing on competion including dismantling / taking out existing earthing and removing dismantling / taken out materials outside the defence land complete all as directed.
Taking out old aluminium bus bar from any location/situation at a height upto 30.00 metre (Max) and removing from site of work all as directed
Dismantling existing LT panel board including fittings/fixtures and removing from site of work all as directed.
KIRTI ELECTRICALS
shiv shanker enterprises
M/S BALWINDER SINGH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .