Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹79.5 L+₹99,144 (1.26%)Rejected-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹82.9 L+₹4.4 L (5.54%)Rejected-Finance 3RD FLOOR F5 III PHASE SYMTEC TOWER EKKATTUTHANGAL CHENNAI TAMIL NADU 600032 | CHENNAI | TAMIL NADU | 600032 | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹85.0 L+₹6.5 L (8.23%)Rejected-Finance | L4 | Rejected-Finance Not L1 |
Tender Value
₹81.4 L
EMD Value
₹1.6 L
Closing Date
27 Jul 2023, 3:00 pmClosed
AGM(EE)
AGM(EE)
Replacement of VFD panels at AC plant at CIA
2023_AAI_160133_1
AAI/CIA/AMED-VIII/HVAC/2023
Open Tender
Electrical Works
Item Rate
240 days
Chennai Airport
As per NIT
14 documents required · 14 mandatory
₹1,180
₹1.6 L
30 May 2024
7 Jul 2023
28 Jul 2023
7 Jul 2023
27 Jul 2023
7 Jul 2023
7 Jul 2023 - 14 Jul 2023
Amount
Sub Head- 1 - Dismantling
Dismantling of entire section of existing panel board comprising of compartments i/c dismantling of existing incoming bus bar trunk, outgoing cable connections & BMS cable connections from all the compartments & handing over to AAI Stores, compartments in the existing panel board are as follows;
MCC Panel - 1 Incomer - 3200 Amps ACB - 1 No. Outgoings - 2000 Amps ACB for LT Chiller - 1 No. 250 Amps MCCB for Secondary pumps - 2 Nos 160 Amps MCCB for Cooling Towers - 2 Nos. 160 Amps MCCB for Primary pump - 1 No. 400 Amps MCCB for Condenser Pump - 1 No. 250 Amps MCCB for Secondary pump (T3) - 1 No.
MCC Panel - 1A Incomer - 3200 Amps ACB - 1 No. Outgoings - 2000 Amps ACB for LT Chiller - 1 No. 250 Amps MCCB for Secondary pumps - 2 Nos 160 Amps MCCB for Cooling Towers - 2 Nos. 160 Amps MCCB for Primary pump - 1 No. 400 Amps MCCB for Condenser Pump - 1 No. 250 Amps MCCB for Secondary pump (T3) - 1 No.
MCC Panel - 2 Incomer - 3200 Amps ACB - 1 No. Outgoings - 800 Amps MCCB for Condenser Pumps - 2 Nos. 250 Amps MCCB for Secondary pumps - 2 Nos 160 Amps MCCB for Cooling Towers - 4 Nos. 250 Amps MCCB for Primary pumps - 2 Nos.
MCC Panel - 2A Incomer - 3200 Amps ACB - 1 No. Outgoings - 800 Amps MCCB for Condenser Pumps - 2 Nos. 250 Amps MCCB for Secondary pump - 1 No. 250 Amps MCCB for Cooling Tower - 1 No. 160 Amps MCCB for Cooling Towers - 4 Nos. 250 Amps MCCB for Primary pumps - 2 Nos.
Sub Head- 2 - Fabrication/SITC
MCC Panel - 1 Compartment for Incomer without switchgear- 3200 Amps ACB - 1 No. (ACB included in SH III) Compartments for following Outgoings with switchgear : 250 Amps MCCB with 75kW VFDs for Secondary pumps - 2 Nos 160 Amps MCCB with 45kW VFDs for Cooling Towers - 2 Nos. Compartments to house the following ACB/MCCBs without switchgear i/c control wiring (Switchgears included in SH III): 2000 Amps ACB for LT Chiller - 1 No. 160 Amps MCCB for Primary pump - 1 No. 400 Amps MCCB for Condenser Pump - 1 No. 250 Amps MCCB for Secondary pump (T3) - 1 No.
MCC Panel - 1A Compartment for Incomer without switchgear- 3200 Amps ACB - 1 No. (ACB included in SH III) Outgoings - 250 Amps MCCB - 75kW VFDs for Secondary pumps - 2 Nos 160 Amps MCCB - 45kW VFDs for Cooling Towers - 2 Nos. Compartments to house the following ACB/MCCBs without switchgear i/c control wiring (Switchgears included in SH III): 2000 Amps ACB for LT Chiller - 1 No. 160 Amps MCCB for Primary pump - 1 No. 400 Amps MCCB for Condenser Pump - 1 No. 250 Amps MCCB for Secondary pump (T3) - 1 No.
MCC Panel - 2 Compartment for Incomer without switchgear- 3200 Amps ACB - 1 No. (ACB included in SH III) Outgoings - 250 Amps MCCB - 75 kW VFDs for Secondary pumps - 2 Nos 160 Amps MCCB - 45 kW VFDs for Cooling Towers - 4 Nos. Compartments to house the following ACB/MCCBs without switchgear i/c control wiring (Switchgears included in SH III): 800 Amps MCCB for Condenser Pumps - 2 Nos. 250 Amps MCCB for Primary pumps - 2 Nos.
MCC Panel - 2A Compartment for Incomer without switchgear- 3200 Amps ACB - 1 No. (ACB included in SH III) Outgoings - 250 Amps MCCB - 75 kW VFD for Secondary pump - 1 No. 160 Amps MCCB - 45 kW VFD for Cooling Tower - 2 Nos. Compartments to house the following ACB/MCCBs without switchgear i/c control wiring (Switchgears included in SH III): 800 Amps MCCB for Condenser Pumps - 2 Nos. 160 Amps MCCB for Cooling Towers - 3 Nos. 250 Amps MCCB for Primary pumps - 2 Nos.
Sub Head - 3 Dismantling & Shifting
Dismantling and shifting of the following ACBs / VFDs from the dismantled old panel board of Item No. 1 to 4 of SH-1 and fix it in the new cubicle panel of SH II, including necessary termination, etc. complete as required.
MCC Panel - 1 Incomer - 3200 Amps ACB - 1 No. Outgoings - 2000 Amps ACB for LT Chiller - 1 No. 22 kW VFD for Primary pump - 1 No. 90 kW VFD for Condenser Pump - 1 No. 75 kW VFD for Secondary pump (T3) - 1 No.
MCC Panel - 1A Incomer - 3200 Amps ACB - 1 No. Outgoings - 2000 Amps ACB for LT Chiller - 1 No. 22 kW VFD for Primary pump - 1 No. 90 kW VFD for Condenser Pump - 1 No. 75 kW VFD for Secondary pump (T3) - 1 No.
MCC Panel - 2 Incomer - 3200 Amps ACB - 1 No. Outgoings - 200 kW VFD for Condenser Pumps - 2 Nos. 55 kW VFD for Secondary pumps - 2 Nos
MCC Panel - 2A Incomer - 3200 Amps ACB - 1 No. Outgoings - 200 kW VFD for Condenser Pumps - 2 Nos. 22 kW VFD - 2 Nos each compartment for Cooling Towers - 3 Sets. 55 kW VFD for Primary pumps - 2 Nos.
vk sam engineering
SYMTEC ENGINEERS PRIVATE LIMITED
SHANTI ENTERPRISES ELECTRICALS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .