PERIODICAL MAINTENANCE AND SERVICING OF REFRIGERATORS ACs WATER COOLER DESERT COOLER WATER HEATER AND REPAIR REPLACEMENT OF STREET LIGHT AND CONNECTED WORKS AT AF STN RAJOKRI AND PERIODICAL MAINT OF STP COOLING APPLIANCES REPAIR TO EXT WS LINES DG S
2023_MES_607138_1
GE/GUR-/NIT-15/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹94,000
9 Sept 2023
30 Jun 2023
31 Jul 2023
30 Jun 2023
28 Jul 2023
14 Jul 2023
Amount
Carry out 'B' check from authorised rep or service engineer from the manufacturer of DG Set of 100 KVA capacity including the cost of the following spares all as per OEM instruction and directed by Engr-in-charge. Note - Contractor should submitted MOU of OEM (Kirloskar) with authorised service Engineer:-
S&F in repair lubrication of oil filter
S&F in repair by pass filter
Cleaning of hydraulic governor
S&F Checking and toping up of coolant
S&F in repair fuel filter
S&F in repair air cleaner element
Cleaning of radiator complete set
Supply and filling Engine oil as per manufacturer specification and any other checking as per manufacturer instruction
All as per item No 1.01 to 1.08 here in before but 62.5 KVA DG Set Make - Kirloskar complete all as specified.
All as per item No 1.01 to 1.08 here in before but 20/25 KVA DG Set Make - Kirloskar complete all as specified.
S&F Solenoid switch suitable for upto 100 KVA DG Set complete all as specified and directed by Engr -in-charge.
S&F in repair ring gear of flywheel suitable for DG set upto 100 KVA complete all as specified and directed.
Supply and fixing in replacement of AVR VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Output DC voltage suitable for DG set upto 100KVA complete all as specified and directed by Engineer -in-charge.
M&L for disconnection and opening of self starter assembly 12/24 volt for repair from DG set upto 100 KVA and repair unserviceable part of self starter suitable size as required on site complete all as specified and directed. Note:- Rate are deemed to be include all worn out part including gear and winding complete all as specified.
M&L for discaling of cooling system of DG set upto 100 KVA by radiwash with two times circulation of rediwash by means of running of engine and cleaning of fan blades, crankcase breather, radiator and its fins by means of high pressure air or water complete all as specified and as directed :
Supply only the following items of DG Set of various capacity :-
Battery terminal, lug, bolts type suitable for heavy duty battery 12/24 V.
Battery leads for copper conductor multiwired 35 Sqmm.
Hinges for DG set door of any size, any type as required on site.
Servo cool plus Radiator coolent
Low viscosity synthetic Engine oil 15W40
M&L for dismantling existing U/S battery charger and S&F of SMPS type battery charger suitable for 12V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG set is not in use complete all as specified and directed by Engr-in-charge.
S&F for 'V' belt for fan pulley (set of 2 Nos) for DG set upto 100 KVA complete all as specified.
S&F for 'V' belt for alternator and water pump assembly for DG set upto 100 KVA complete all as specified.
S&F for fuel hose pipe from fuel filter to fuel pump for DG set upto 100 KVA complete all as specified.
S&F for fuel pipe from fuel tank to fuel filter for DG Set upto 100 KVA complete all as specified.
M&L for carrying out complete over hauling/servicing of DG set panel /AMF panel/control panel including checking and rewiring of faulty electrical circuit using 1.5 Sqmm FRLS copper conductor for DG set of any type/make /capacity and making all electric connection and testing for smooth operation complete all as directed.
S&F of under/over voltage relay 3 phase 415V for DG set of capacity upto 100 KVA all as specified and directed.
S&F of battery voltage relay 12/24V DC complete all as specified and directed.
S&F of fuse for DG Set of capacity upto 100 KVA complete all as specified and directed. Make-L&T/ABB/Havells
S&F in replacement of lead acid maintenance free battery 12V 130AH of existing type and size suitable for DG set. Make - Exide/AMCO including initial charging complete all as specified.
S&F in replacement of 63 to 160 Amps, 415V, 50 Hz, MNX Power contactor of coil voltage 240V complete all as specified and directed. Make-- L&T/Schineider/Hevells.
M&L for attending of any breakdown of standby power supply in any location, whenever required round the clock, rectify the fault and restore the standby supply within three hours after receipt of complaint of any nature ie engine, alternator, control panel/AMF panel etc complete all as directed. Note- (i) The cost of replaced spare parts will be paid and measure separately. (ii) If complaint is not attended by contractor with in five hours the penalty of Rs 500/- per hour to be imposed and amount of penalty will be deducted from RAR. (iii) The cost of transportation (to and from) for all kind of necessary equipment /T&P shall be arranged/brought by contractor to complete the job at site or at E/M Yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically so contractor to specify the telephone/mobile No who will receive the complaint round the clock.
M&L for opening/taking out of injector of DG set of any type/capacity /make upto 100 KVA disconnection and opening of fuel injector assembly carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit including calibration of injector , checking the allignment and making proper fuel connector and testing for smooth operation complete all as specified and directed.
S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set commection testing complete all as specified and directed.
M&L for complete overhauling/servicing of turbo charger, opening/taking out of turbo charger of DG set upto 100 KVA capacity, disconnection of air supply connection pipe etc including replacement of turbo charger repair kit, calibration testing of turbo charger system complete and re-assembling the same fitted with DG set properly in original position, checking the alignment and making all connection, testing for smooth operation from authorised rep or service engineer from the manufacturer complete all as specified and directed.
M & L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified.
Taking down and dismantling HPSV street/flood/garden light fitting with GI bracket for 70/150/250 watt capacity of any make/type from pole/GI pipe unserviceable items etc complete all as specified and directed.
Supply and Fixing in replacement LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant. Complete all as specified and as directed. make of CG or its equivalent in Wipro/Phillips Note : Any reducer to suit the manufacturer mounting dia for fixing of fitting to existing bracket shall be deemed to be included in the rates quoted by the Contractor
Supply and Fixing in replacement circular LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant. complete all as specified and as directed . Cat Part No. LFLN-90 cdl make of CG or its equivalent in Wipro/Phillips Note : Any reducer to suit the manufacturer mounting dia for fixing of fitting to existing bracket shall be deemed to be included in the rates quoted by the Contractor.
Supply and Fixing LED street light luminaire 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed . Make: CG or its equivalent in Wipro/Havells/Surya
Supply and Fixing LED street light luminaire 70 Watt 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including two run PVC multi stranded copper conductor of size 1.5 Sqmm 2 core for street light fitting to junction pole box complete all as specified and as directed . Make: CG or its equivalent in Wipro/Havells/Surya
Supply and fixing weather proof street light junction box of size 300 x 200 x 105mm including MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and outgoing cables, gland for cable etc of suitable size complete all as specified and as directed. Make : Hensel/Sintex/Universal Switch Gear control. Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection.
Supply and Fixing LED post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed . Make: CG or its equivalent in Wipro/Havells/Surya
Supply and fixing LED Solar street light fitting 45 Watt including galvanized steel pole in built, suitable size and capacity lithium ion battery, solar panel, charge controller with dusk down sensor complete Including excavation, earth work and PCC 1:3:6 for fixing of solar light pole complete all as specified and as directed
Supply and Fixing in replacement LED decorative Garden/post-top light for 360 degree indirect light IP-65 grade of protection with High power LED of 10 watt with resistance to impact and corrosion. Glare free and better uniformity. Milky version .complete all as specified and as directed . Cat Part No. LBLS1-10-CDL make of CG or its equivalent in Wipro/Phillips. Note : Any reducer to suit the manufacturer mounting dia for fixing of fitting to existing bracket shall be deemed to be included in the rates quoted by the Contractor.
M&L in replacement for sub main wiring with two single core 1.5 sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in 20 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 1.5Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire, cable lugs complete all as specified and directed by Engr-in-charge.
Comprehensive maintenance of electric water heater storage type of capacity 25/50 Ltrs, 230 volts single phase AC and descaling of inner tank of geyser ,including brazing /welding if required ,replacement of worn out parts, re-assembling and refixing on site ,including preparation of surface of geyser and painting with 2 coat of white enameled paint by spray painting machine complete all as specified and directed. Note :- Spares parts will be measured and paid separately under respective items.
S&F in replacement of geyser assembly 06/09 holes with washer suitable to fix thermostat , heating element of the existing size including clamps with bolts and nuts etc complete all as specified and directed.
S&F in replacement of heating element 2000 watt capacity triangular type complete all as specified and directed. .
S&F in replacement of heating element 1500 watt capacity triangular/circular type complete all as specified and directed.
S&F in replacement of thermostat suitable for 25/50 Ltrs storage type water heater complete all as specified and directed. .
Supply and fix stainless steel tank for 25 ltr storage type water heater complete all as specified and directed..
Supply and fix Copper tank for 25 ltr storage type water heater complete all as specified and directed. .
S&F in replacement of light indicator (Red & Green colour) suitable for 25/50 ltrs water heater complete all as specified and as directed.
M&L for Servicing, Oiling, Greasing and Cleaning of window type/ split type AC, 1.5/2 Ton with high pressure pump/jet machine with complete kit of any capacity, checking of defects/ leakage of gas and adjusting setting to work and testing complete all as specified & directed.
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of window/ split type AC 1/1.5/2 Ton capacity complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A"
M&L for replacement running capacitor of existing makes and capacity duly ISI marked for Window / split type AC, 1/1.5/2 Ton capacity complete all as specified and directed.
M&L for replacement of starting relay of existing makes and capacity duly ISI marked for window / split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
M&L for replacement starting capacitor of existing make and capacity duly ISI marked for window type A/C 1.5 ton and split type AC 1/1.5/2 ton capacity complete all as specified and directed.
S&F in replacement of Electronic control (PCB) of existing makes and capacity duly ISI marked for Window and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for Window and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
S&F in replacement of blower motor for window/split type AC of capacity 1.5/2.0 Ton complete all as specified & directed.
S&F in replacement of new rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5/02 Ton capacity complete all as specified & directed.
S&F in repair replacement new sealed compressor reciprocating type suitable for split/ window type AC, 1.5/02 Ton capacity single phase, 230 Volt, 50 Hz in and including refilling refrigerant gas R-22 filling up to required pressure and testing complete all as specified and directed.
S&F in replacement of Evaporator coil for Window and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
S&F in replacement of Suction/Discharge valve for Window and split type AC 1/1.5/2 Ton capacity complete all as specified and directed.
S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC 1/4 complete all as specified and directed.
S&F in replacement of Copper tube for 1.5 /2.00 Ton split AC 1/2 complete all as specified and directed.
S&F in replacement of Copper tube cover complete all as specified and directed.
Material and labour for PVC drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement all as specified and directed.
S&F in replacement of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and directed.
M&L for shifting/relocating of split/window type AC 1.5/2 Ton from one location to another location as required including all connected works complete all as specified and directed by Engr-in-charge. Note:- (i) The cost of dismantling and refixing of Split/Window type AC deemed to be included in unit rate.
M&L for servicing, oiling, Greasing and Cleaning of water cooler of any capacity with high pressure pump , checking of defects/ leaking of gas and adjusting setting to work and testing complete all as specified & directed.
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of any capacity complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A" (iv) Refilling and toping up of refrigerant (type and quantity) as required on site is measured and paid separately.
S&F compressor reciprocating type (hermetically) sealed for capacity 40/80/160 litre water cooler complete all as specified and as directed.
S&F in repair of thermostat switch suitable for existing water cooler any make and capacity complete all as specified and as directed. Make: Renutrol/Indofos/Annapurna/Totaline
M&L in replacement of starting relay and overload relay suitable for existing size and make water cooler complete all as specified and as directed. Make: Epcos/Asian
M&L in replacement of starting capacitor for water cooler suitable for existing size & make water cooler complete all as specified and as directed.
M&L in replacement of running capacitor suitable for existing size & make water cooler complete all as specified and as directed.
M&L for dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge including replacement of shaft/ bush etc complete all as specified and as directed.
S&F in replacement of fan blade of condenser motor of any make and capacity of water cooler complete all as specified and as directed.
S&F of wastage water tray of any capacity of water cooler complete all as specified and directed.
M&L for servicing of deep freezer any capacity and size by cleaning greasing including painting with one coat of super synthetic enameled paint including preparation of surfaces complete all as specified and as directed.
S&F of starting relay of deep freezer of any size & make complete all as specified and as directed.
M&L for gas charging in deep freezer any make and capacity including testing of leakage complete all as specified and as directed.
S&F of thermostat switch for deep freezer any make & capacity complete all as specified and as directed.
M&L for servicing, oiling, cleaning greasing of refrigerator any capacity including replacement of following unserviceable parts, starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, thermostat switch - 01 No, Door rubber beeding set - 01 Set complete all as specified and directed.
S&F in repair replacement new sealed compressor suitable for Refrigerator of any capacity single phase, 230 Volt, 50 Hz in and including refrigerant gas filling up to required level complete all as specified and directed.
Supply & fix in replacement ceiling fans complete with accessories 230 V,1200 mm sweep. BEE 5 star rated complete all as specified & directed by engr - in- charge
Supply & fix in replacement exhaust fans single phase 230/ 240 V of size 450 mm sweep with louver Steel body complete all as specified & directed by Engr - in- charge
Supply & fix in replacement pedestal fans single phase 230/ 240 V of size 450 mm sweep with louver Steel body complete all as specified & directed by Engr - in- charge
Supply & fix in replacement wall Mounted fans single phase 230/ 240 V of size 400 mm sweep with louver Steel body complete all as specified & directed by Engr - in- charge
M&L for rewinding of following fans with same gauge of super enameled copper wire complete varnishing ,baking ,connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nots /bolts/washer /split pin and blade screw s etc testing , complete all as specified and directed. NOTE: (i) Spare parts like bearing, capacitor, bushes if required will be measured and paid separately. (ii) The rates shall be deemed to include dismantling of fan and reassembling after repair /replacement of worn out parts.
Ceiling fan 1200 /1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Wall mounted fans 400 mm /450mm sweep
Supply and fix in repair ball bearing suitable for the following fans : Make :-NBC/SKF/Tata
Ceiling fan 1200 /1400 mm sweep
Exhaust fan 300 mm sweep
Exhaust fan 450 mm sweep
Wall mounted fan 400 mm sweep
M&L for servicing, cleaning of RO water purifier of any make/size and capacity with high pressure pump, checking of defects/adjusting setting to work and testing complete all as specified & directed.
S&F in replacement of RO water purifier candle of existing size and make complete all as specified and as directed
S&F in replacement of RO water purifier membrane of existing size and make complete all as specified and as directed
S&F in replacement of RO water purifier booster pump of existing size and make complete all as specified and as directed
S&F in replacement of RO water purifier PVC inlet/out pipe of existing size and make complete all as specified and as directed
Supply and fix in repair capacitor 2.5 mfd, 230 volt ,50 hz all as specified and as directed.
Supply and fix in repair capacitor 3.15 mfd, 230 volt ,50 hz all as specified and as directed.
Supply and fix in repair capacitor 4 mfd, 230 volt ,50 hz all as specified and as directed.
M&L for excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out soil all as specified and directed.
M&L for returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
M&L for removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete as specified and directed.
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as directed. Note : Punned down thickness shall be measured and paid .
Supply and laying un-reinforced precast concrete LV cable cover class Type I with 250 x 150 x 40 mm, as specified and directed.
Supply and fix GI pipe light grade of sizes 80mm for cable protection in trenches/ at PCC poles for loopin/loopout of cable and cable entry at bldg/block end, all as per specified and directed.
Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade with following cross sectional area complete all as specified and as directed. Note : Provision of suitable double crimpped lugs, glands and suitable size aluminium thimbles deemed to be included in quoted rates.
XLPE LT Cable 3.5 core 120 Sqmm
XLPE LT Cable 3.5 core 50 sqmm
XLPE LT Cable 4 core 25 sqmm
Taking down the existing LT cables from trenches of any size complete all as specified and directed.
Supply & install in repair testing , commissioning of feeder pillar board Kiosk type ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) floor mounted , factory assembled, outdoor type weather and vermin proof (Protection Class IP-54) made out of 40m x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated externally and internally after seven tanks treatment and lifting channel, fully compartmentalized design complete Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding complete all as specified and as directed.
M&L for cutting, clearing bushes/small plants and grass surrounding the E/M installations and removing the debris to a distance of 50m complete all as specified.
S&F MCCB 100 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. Make: Legrand/Siemns/ABB/Schneider
S&F MCCB 125 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. Make: Legrand/Siemns/ABB/Schneider
S&F MCCB 250 A ,3 pole ,16 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge. Make: Legrand/Siemns/ABB/Schneider
(v) Indicating lamp- 01 set of three (vi) Aluminium bus bar of rating 400A- set of four (b) Outgoing . (i) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 02 Nos (ii) MCCB 4 pole , 160 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 02 Nos (c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. . Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 1
Supply and installation in replecement of Hot dipped Octagonal galvanized iron pole 8 mtr height, with necessary Foundation RCC 1:1:5:3 with 8Nos.16 mm dia tor bar as main bars and 8mm dia.Tor bars strips@190mm c/c as this reinforcement shall confirm to IS : 1786 latest edition. The foundation shall extend above surroundings ground/drive way level for 200 mm and have DWC 63 mm dia, PVC sleeve cast foundation for cable entry, Excavation, RCC and reinforcement etc as per manufacturer recommendation and the cost of necessary foundation , steel bars , strip as per Manufacturer instructions and as specified .
Carry out 'B' check from authorised rep or service engineer from the manufacturer of DG set of 500 KVA, capacity Make : Cummins ( including the cost of the following spares all as per OEM instructions and directed by Engineer in Charge. (Note:- contractor should submit MOU of OEM cummins with authorised service engineer & Necessary test report shall be submitted) . (a) S & F in repair lubrication oil filter (b) S & F in repair by pass filter (c ) Checking of hydraulic governor (d) Checking and toping up of coolant (e) S & F in repair fuel filter. (f) S & F in repair air cleaner element . (g) Cleaning radiator complete set (h) Engine Oil as per manufacturer specification and any other checking as per manufacturer instruction.
All as per item No.107 (a) to (h) here in before but for up to below 250 KVA DG set Make Cummins complete all as specified.
All as per item No.107 (a) to (h) here in before but for up to below up to 380/400 KVA DG set Make cummins complete all as specified .
Supply and fixing in replacement of AVR S/F VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Output DC voltage suitable for DG set upto 500KVA complete all as specified and directed by Engineer -in-charge.
Disconnected and opening of self starter assembly 12/24 volt from 500 KVA DG set taking out unserviceable part of self starter and supply and fixing in replacement of self suitable size as required on site complete all as specified and directed. (Note:- Rate are deemed tobe include all wom out part including gear & winding complete all as specified).
Dismantling of radiator fan engine of capacity upto 500 KVA, cleaning and chocked tubes after draining out water, washing with caustic, descaling and brazing for water leakage etc. and refixing the same properly complete all as specified & directed.
Supply only the following items of DG Set of various capacity complete all as specified and as directed:-
a) Battery terminal, lug, bolts type suitable for heavy duty battery.
b) Battery leads for copper conductor multiwired 70 Sqmm. Single Core
c) Hinges for DG set door of any size, any type as required on site.
Dismantling existing U/S battery charger & S/F of SMPS type battery charger suitable for 12 V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG Set is not in use complete all as specified & directed by Engineer In charge.
Supply only coolant suitable for generator set diesel engine driven of best quality ISI marked complete all as specified and directed.
S&F V belt for fan pulley (set of 2Nos) for DG set upto 500 KVA DG Set complete all as specified.
S&F V belt for alternator and water pump assembly for DG set upto 500 KVA complete all as specified.
S&F Fuel hose pipe from fuel filter to fuel pump for DG set upto 500 KVA, complete all as specified.
S&F Fuel pipe from fuel tank to fuel filter for DG set upto 500 KVA, complete all as specified.
Supply and fixing of 'under/over voltage relay, 3 phase, 415 volts', for DG sets of capacity upto 500 KVA complete all as specified and directed by engineer-in-charge.
Supply and fixing of battery voltage relay 12 VDC complete all as specified and directed.
Supply and fixing of Fuse (HRC type) for DG sets of capacity up to 500 KVA complete all as specified and directed. Make: L&T/ABB/Havells
Supply and fixing in replacement of Lead acid maintenance free Battery 12 Volts 120AH of existing type & size suitable for DG Sets complete all as specified and directed by engineer-in-charge. Make : EXIDE/AMCO including initial charging.
Supply and fixing in replacement of 63 to 160 Amp, 415 Volts, 50 Hz Power contactor of coil voltage 240 Volts, complete all as specified and directed. Make: L&T/Schineider/Havells
Material & labour for opening / taking out of injector of DG set of any type/make and capacity 250 KVA to 500 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making proper fuel connection, testing for smooth opreatio complete all as directed.
S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set connection testing complete all as specified and directed.
Material & labour for complete overhauling, servicing of turbo charger, opening /taking out of turbo charger of DG set of 250 KVA to 500 KVA capacity ,disconnection of air supply connection pipe etc, including replacement of turbo charger repair kit, calibration/ testing of turbo charger system complete and re-assembling the same ,fitted with DG set properly in original position, checking the alignment, making proper all connection, testing for smooth operation from authorised rep or service engineer from the manufacturer complete all as directed.
Carry out periodical maintenance & servicing (monthly) from authorised rep or service engineer from the manufacturer of blower of STP ( including the cost of replacement of Gear oil , Replacement of worn out helical Gear, worn out blower motor Fan & fan belt etc.) all as per OEM instructions and directed by Engineer in Charge . Note : contractor should submit MOU of OEM with authorised service engineer.
comprehensive maintenance for repair by periodical (monthly) checking of motor compressor system , valve , STP pipe line , fillter system , pressure guage including air compressor complete coupling & leakage joint & repair / replacement of worn out parts of sewage treatment plant as existing complete all as specified and as directed. Note : i. technician should attend breakdown on as and when Requaired to rectified the defect urgently. . ii. Defective parts shall be measured & paid separately
S&F in replacement of fan belt for compressor / flactuator motor any size & any type as per sample complete All as specified & directed by engr-in-charge.
S&F in replacement of Butter fly / Ball Valve 50 mm nominal bore CPVC complete All as specified & directed by engr-in-charge.
S&F in replacement of Sewage side flow meter as per sample for STP complete All as specified & directed by engr-in-charge.
S&F in replacement of treated side flow meter as per sample for STP complete All as specified & directed by engr-in-charge.
S&F in replacement of Dosing Pump as per sample for complete All as specified & directed by engr-in-charge.
S&F in replacement of pressure gauge / rotometer as per sample for STP complete All as specified & directed by engr-in-charge.
M&L for repair blower as per sample for STP complete All as specified & directed by engr-in-charge.
S&F in replacement of chemical injection pipe as per sample complete All as specified & directed by engr-in-charge.
M&L for Repair , servicing & Maintenance of chemical injection pump with complete serviceable condition including replacement of worn out part complete All as specified & directed by engr-in-charge.
M&L for taking out / down pump / motor from base / chambber & opening of the motor up to 7.5 HP carefully & removing burnt windding from stator & rewinding with same gauge of supper enamelled copper insulated wire & superior insulating material including warnishing , heating , greacing replacement of worn out bearring , reassembling the same including testing on full load up to entire satisfaction complete All as specified & directed by engr-in-charge.
M&L for removing burnt winding from stator & rewinding with same gauge of supper enameled copper wire & superior insulating material including varnishing , heating , greasing replacement of worn out bearing , reassembling the same including testing on full load for 3 HP press feed pump up to entire satisfaction complete All as specified & directed by engr-in-charge.
M&L for taking out & cleaning of BAR screen chamber / oil & greace trap / equalization tank / MBBR Tank / floculator tank / tube satteler tank / chlorine contact tank / fillter feed tank / treated water tank , dewatering & digging out sludge , mud state & removing sludge to a distance exc. 250m & N exc 500 m & disposed of complete All as specified & directed by engr-in-charge. Note :- i. Rate are deemed include for transportation & labour Charge from STP to low laying area complete All as specified & directed by engr-in-charge. ii. Cleaning of sluge shall be carried out 2 times of with interval of 3 months each cleaning shall be measured as each job
M&L for taking out & cleaning of sludge draing bed of STP any size digging out sluge , mud state & removing sluge to a distance exc. 250m & n exc 500 m & disposed of complete All as specified & directed by engr-in-charge. Note :- i. Rate are deemed include for transportation & labour Charge from STP to low laying area complete All as specified & directed by engr-in-charge. ii. Cleaning of sluge shall be carried out 2 times of with interval of 3 months each cleaning shall be measured as each job
Supply only Nitrogenous frertiliser conten 46% nitrogen, Biuret % by weight Max 1.5%, in 50 Kg packets complete all as specified and directed by engineer-in-charge.
Supply only diammonium phosphate phosphorus furtiliser contain nitrogen 18 %, phosphorus 46%in 50 kg complete all as specified and directed by engineer-in-charge. packets
M&L for repairs & Servicing of defective submersible pump of capacity 10 HP by dismantling the pump & removing unserviceable parts , assemble the pump properly after replacements of unserviceable parts complete all as specified and as directed. . Note:- (a) The rates are inclusive of transporting the pump from bore well site to repair work shop & back to site. (b) The rate are inclusive of turning / finishing work for fixing of parts properly. (c) The replacement of unserviceable parts will be measured and paid separately under respective item of this schedule.
M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 10 HP complete all as specified and as directed.
Demolition of existing valve pit chamber , M&L for masonry valve pit of size 900x900x900mm internal size complete with excavation, earth work and brick work in CM 1:6, 15mm thick plastering in CM 1:4 internally including 5mm thick MS Sheet cover and angle iron frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer complete with locking arrangement complete all as specified and directed.
Lifting and taking out the submersible pump set and motor of capacity Upto 12.5 HP including column pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sump /bore well and lowering back the pump after repairing from the pump including making electrical connection with the existing panel /starter and connecting the complete the column pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as directed. Note :- Rate are deemed to be inclusive for jointing of Submersible Cable , reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete.
Supply and fixing in replacement of flat submersible 3 core 6 sqmm cable PVC insualted unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
Supply and Fixing LED street light luminaire IP-66 grade of proterction with 24 High power LED of 70 watt rating with unique peanut lens to ensure uniform distribution complete all as specified and as directed .
Supply and fix in replacement of automatic timer switch panel mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as specified and as directed. Note: (i) Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr deemed to be included in the unit rate. (ii) Provn of glands and lugs shall be deemed to be included in the quoted rate.
S&F in replacement of heating element 2000 watt capacity triangular type complete all as specified and as directed.
S & F replacement PVC connection pipe with synthetic coating & washer suitable for hot /cold water of geyser complete all as specified and as directed.
M &L for Carry out Servicing, Oiling, Greasing and Cleaning of window type/ split type AC from authorised rep or service engineer from the manufacture with high pressure pump of 2 Ton capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified & as directed. Note :- contractor should submit MOU of OEM with authorized service engineer.
M &L for Carry out Servicing, Oiling, Greasing and Cleaning of window type/ split type AC from authorised rep or service engineer from the manufacture with high pressure pump of 1.5 Ton capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified & as directed. Note :- contractor should submit MOU of OEM with authorized service engineer.
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.5 ton Split/W/T type AC complete all as specified and as directed.
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 2.0 ton Split/W/T type AC complete all as specified and as directed.
M&L for detection/rectification of leakage of gas in the system Through with NDT test and gas charging in the system with appropriate quantity of gas as per OEM Recommendations including testing for smooth functioning of Split AC of capacity 1.5 Ton complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be included in unit rate. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured under respective items of Sch "A" (iv) Refilling and toping up of refrigerant (type and quantity) as required .
M&L for detection/rectification of leakage of gas in the system Through with NDT test and gas charging in the system with appropriate quantity of gas as per OEM Recommendations including testing for smooth functioning of Split AC of capacity 2 Ton complete all as specified and as directed. Note:-(i) Unserviceable condensing coil if required (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured under respective items of Sch "A" (iv) Refilling and toping up of refrigerant (type and quantity) as required.
M&L for replacement running capacitor of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
M&L for replacement of starting relay of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
M&L for replacement starting capacitor of existing make and capacity duly ISI marked for window type A/C 1.5 ton and split type AC 1/1.5/2 ton capacity complete all as specified and as directed.
S&F in replacement of Electronic control (PCB) of existing makes and capacity duly ISI marked for W/T and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
Repair to compressor off size of existing makes and capacity for W/T and split type AC 1.5 Ton capacity complete all as specified and as directed.
Repair to compressor off size of existing makes and capacity for W/T and split type AC 2 Ton capacity complete all as specified and as directed.
S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for W/T and split type AC 1.5/2 Ton capacity complete all as specified and as directed.
S & F Rewinding of blower motor of capacity 1.5/2.0 Ton complete all as specified & as directed.
S&F in repair/replacement of rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 1.5Ton capacity complete all as specified & as directed.
S&F in repair/replacement of rotary type AC compressor of window type/split AC with reconditioned & repaired compressor from authorized dealers of company in exchange including gas charging of capacity 2.0 Ton capacity complete all as specified & as directed.
S&F in repair/ replacement compressor reciprocating type suitable for 2.0 Ton capacity single phase, 230 Volt, 50 Hz split/ window type air conditioner in and including refrigerant gas filling up to required level complete all as specified and as directed.
S&F in replacement of Evaporator coil 1.5/2 Ton complete all as specified and as directed.
S&F in replacement of Suction/Discharge valve complete all as specified and as directed.
S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC 1/4 complete all as specified and as directed.
S&F in replacement of Copper tube for 1.5 /2.00 Ton split AC 1/2 complete all as specified and as directed.
S&F in replacement of Copper tube cover complete all as specified and as directed.
Material and labour for drain pipe rigid and flexible 20mm dia with clamps of suitable size as per site requirement complete all as specified and as directed.
S&F in replacement of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and as directed. Note :- Rate quoted by contractor should include making the distrub surface as this (plastering & white washing & painting with same)
M&L for Carry out Servicing Oiling, Greasing and Cleaning of water cooler of capacity 40/80 ltrs from authorised rep of service engineer from the manufacture with high pressure pump, checking of defects/leaking and adjusting setting to work and testing complete all as specified and as directed. Note:- contractor should submit MOU of OEM with authorised service engineer.
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of capacity 40/80 ltr complete all as specified and as directed. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A" (iv) Refilling and toping up of refrigerant (type and quantity) as required on site is measured and paid separately.
S&F in repair/replacement compressor reciprocating type (hermetically) sealed for capacity 40/80 litre water cooler complete all as specified and as directed.
S&F in repair of thermostat switch suitable for existing water cooler any make and capacity complete all as specified and as directed. Make: Renutrol/Indofos/Annapurna/Totaline
M&L in replacement of starting relay and overload relay suitable for existing size and make water cooler complete all as specified and as directed.
M&L in replacement of starting capacitor for water cooler suitable for existing size & make water cooler complete all as specified and as directed.
M&L in replacement of running capacitor suitable for existing size & make water cooler complete all as specified and as directed.
Dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge or gauge as approved by Engineer-in-Charge including replacement of shaft/ bush etc complete all as specified and as directed.
S&F in replacement of fan blade of condenser motor of any make and capacity of water cooler/AC/Ref or deep freezer complete all as specified and as directed.
M&L for servicing of deep freezer any capacity and size by cleaning greasing including painting with one coat of super synthetic enameled paint including preparation of surfaces complete all as specified and as directed.
S&F of starting relay of deep freezer of any size & make complete all as specified and as directed.
M&L for gas charging in deep freezer any make and capacity including testing of leakage complete all as specified and as directed.
S&F of thermostat switch for deep freezer any make & capacity complete all as specified and as directed.
M&L for Repair and maintenance, refrigerator of any capacity including replacement of following UNSV Parts starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, thermostate switch - 01 No, Door rubber beeding set - 01 Set complete all as specified and as directed.
S&F in repair replacement compressor of suitable for Refrigerator of single phase, 230 Volt, 50 Hz of Refrigerator in and including refrigerant gas filling up to required level complete all as specified and as directed.
S & F of thermostat switch for refrigerator any make & capacity complete all as specified and as directed.
Attending Complaints by deploying sufficient labour for rectification of leakage of UG water pipe lines of size 80 to 100 mm Bore of any description such as CI/GI pipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material complete all as specified and as directed.
All as per Item No 194 above but for upto 50mm dia pipe line. . Note for Items 194 & 195:- (i) Complaint shall be notified to contractor on mobile phone. Hence, it is mandatory to mention his mobile No. while quoting the tender. ii) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and will be rectified within 12 hours after notification, failing which double of quoted rate per day per complaint will be recovered iii) Completion report of the complaint shall be given in writing and recorded in the register. iv) Rates quoted shall be deemed to include the cost of T&P required. Pipes and Jointing material shall be measured and paid under relevant items of schedule.
Attending leakage complaints of sluice valves by opening removing gland plate and pumping/taking water from water pit and proving gland packing and refitting by replacing worn out bolts, nuts and washers complete all as specified. Note: bolts, nuts and washers will be paid under relevant items of schedule.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 50mm dia bore complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 40mm dia bore complete all as specified and directed by Engr-in-Charge.
M& L for complete dewatering and cleaning of underground sump of capacity 50K gallons with high pressure jet to remove all masses ,algae and dirt and removal of dirty water along with sludge using sludge machine and disposal of same to a safe distance and including scrubbing of internal surface using industrial vacuum machine and applying of anti-bacterial sterilization spray and apply one coat white wash to wall , floor and ceiling , internal surface of reservoir where applicable all as directed by engr-in-charge.
M& L for complete dewatering and cleaning of underground sump of capacity 10K gallons with high pressure jet to remove all masses ,algae and dirt and removal of dirty water along with sludge using sludge machine and disposal of same to a safe distance and including scrubbing of internal surface using industrial vacuum machine and applying of anti-bacterial sterilization spray and apply one coat white wash to wall , floor and ceiling , internal surface of reservoir where applicable all as directed by engr-in-charge.
M&L for comprehensive maintenance & repair of Hydro pneumatic system (Make: Grund Fos) checking of motor, Well Vent Air Release Valve vertical turbine Pump, Water Meter ,ASME Pressure Relief valve Including Replacement of air water control unit Complete all as specified & directed by Engr-in-charge.
M&L for rewinding of electric motor upto 15 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 25mm dia bore complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 20mm dia bore complete all as specified and directed by Engr-in-Charge.
Taking down old U/S any type /capacity gate valve all as specified and directed by engr-in-charge.
Supply only calcium based white to off white free flowing solid granules chemicals having chlorine content of minimum 60% for chlorination in 45 kg packing complete all as specified and directed.
Taking the water sample for semi underground sump and submitted the sample of water to the Govt lab for testing of water Qutarly ,Chlorine test and all chemical components test complete all as specified and as directed.
Supply laying, testing GI tubing 40mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 25 mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 20 mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing CPVC pipe (SRD 11) line 20 mm dia bore with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing CPVC pipe (SRD 11) line 25 mm dia bore with all fittings laid in trenches complete all as specified and directed.
.Excavation in trenches not exceeding 1.5m wide and not exceeding 1.50m deep for laying of water pipe lines/taking out pipe lines and getting out in any type of soil including forming bottom surface to required level and slope all as specified and directed.
Returing, filing including spreading ,leveling ,watering and well ramming in layers not exe. 2.5 cm soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Taking down of existing GI tubing 40/50/80mm bore any type complete all as specified and as directed.
Taking down of existing GI tubing 25mm bore any type complete all as specified and as directed.
Taking down of existing GI tubing 20mm bore any type complete all as specified and as directed.
Supply and fix in replacement cast iron flanged drilled heavy duty Non Return sluice valve with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers etc of size 80 mm bore complete all as directed by Engr-in-Charge.
Supply and fix parts of submersible pump set of capacity 10 HP complete all as specified and as directed.
(i) Bearing bush Gun Metal
(ii) Bearing bush SS with rubber
(iii) Oil seal
(iv) Thrust plate/thrust bearing set
(v) Sand Guard
(vi) CI Thrust Casing
(vii) CI stage casing
(viii) GM Bush
(ix) Mild steel key for impeller
(x) SS Studs with nuts
(xi) CI Intermediate section
(xii) SS coupling bush common for pump & motor with key
(xiii) High Tensile steel shaft
Supply laying, testing GI tubing 80mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and as directed.
Supply laying, testing GI tubing 50mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and as directed.
YASHVI ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .