Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.1 CrAccepted-AOC | ₹2.1 Cr | 1 | Accepted-AOC Being L1 |
| 2 | 2₹2.2 Cr+₹10.0 L (4.83%)Rejected-Finance | ₹2.2 Cr+₹10.0 L (4.83%) | 2 | Rejected-Finance Since not L1 |
| 3 | 3₹2.4 Cr+₹29.4 L (14.1%)Rejected-Finance | ₹2.4 Cr+₹29.4 L (14.1%) | 3 | Rejected-Finance Since not L1 |
| 4 | 4₹2.6 Cr+₹51.5 L (24.7%)Rejected-Finance | ₹2.6 Cr+₹51.5 L (24.7%) | 4 | Rejected-Finance Since not L1 |
| 5 | 5₹2.7 Cr+₹63.0 L (30.3%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹2.7 Cr+₹63.0 L (30.3%) | 5 | Rejected-Finance Since not L1 |
Tender Value
₹2.4 Cr
EMD Value
₹3.1 L
Closing Date
25 Apr 2022, 6:00 pmClosed
Chief Engineer RnD Secunderabad
Chief Engineer RnD Opp JBS Picket Secunderabad 500003
CONSTRUCTION OF BUILDING FOR HIGH DYNAMIC PRESSURE SUPERSONIC WIND TUNNEL FOR DIRECTORATE OF AERODYNAMIC TESTING DOAT AT DRDL HYDERABAD
2022_MES_512318_1
84974
Open Tender
Civil Works
Lump-sum
365 days
Kanchanbagh Hyderabad
class B category a i
8 documents required · 8 mandatory
₹2,000
GE I RnD Kanchanbagh
₹3.1 L
Yes
25 May 2022
7 Mar 2022
2 May 2022
7 Mar 2022
25 Apr 2022
11 Apr 2022
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01 to 1.05) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of Wind Tunnel Hall building, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Model Storage building, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Toilet Block building, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Supply and laying on site LLDPE septic tank for 25 Users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundaion, vent shaft, connection with upflow filter including media, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Construction of Soakage well of size 1.80 m dia and 3.00 m effective depth, complete all as shown on drawings and as specified.
Lump sum price worked out by the Contractor for “ EXCAVATION, EARTHWORK,SITE CLEARANCE,AREA DEVELOPMENT AND DEMOLITION ” as listed in Schedule ‘A’ Part - II representing _______ % ______________ percent Above / Below the lump sum price of `7,22,658.49 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “ ROAD / PATH / CULVERT / HARD STANDING ” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of ` 91,941.20. inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “ SEWAGE DISPOSAL ” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of `2,00,113.01 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for " AREA DRAINAGE” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of `5,80,421.12 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for "INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VI representing _______ % __________________ percent Above / Below the lump sum price of `13,445.04 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `5,71,832.70 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “ EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VIII representing _______ % _________________ percent Above / Below the lump sum price of `47,45,831.84 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - IX representing ______ % _________________ percent Above / Below the lump sum price of ` 48,406.21 inserted by the MES in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for “ LIGHTENING PROTECTION ” as listed in Schedule ‘A’ Part - X representing ______ % _________________ percent Above / Below the lump sum price of `1,00,128.80 inserted by the MES in Schedule ‘A’ Part - X
Schedule 'A' Part - XI This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 12.00 to 49.00
INTERNAL WATER SUPPLY Supply and fix, two way bib cock, cast copper alloy, chromium plated for size 15mm dia with crutch or butter handle, screwed down for iron pipe complete all as specified and directed.
Supply and fix, health faucet cast copper alloy ,chroimum plated including 1 mtr long pipe, and all fittings to fix screwed down for iron pipe complete all as specified and directed
INTERNAL ELECTRIFICATION Supply and fix, High bay 100W LED light fittings IP65 protected luminaire robust open type vertical Highbay luminous efficiency not less than 150 lm/w, CCT 5700K along with not less than 4 KV surge protection, electronic driver inclduing fixing to the ceiling using necessary fastner/hook for hanging the lights and connecting with three core 2.5Sqmm round copper cable from ceiling rose to the connector of the fitting all as specified and directed.
Supply & Fix 2x2 recessed mounted energy efficient LED luminaire 36W, with luminous efficacy of 120lm/watt , 5700 K CCT with electronic driver suitable for false grid ceiling complete with all accessories prewired and connecting up with three core 1.5sqmm round PVC copper conductor cable complete all specified and directed.
Supply & Fix Security light fitting 20 W IP 66 protection, color temp (Cool White) pressure die cost aluminium body with high power LEDs as light source and tranparent diffuser, inbuilt electronic driver and luminous efficacy of 120lm/watt fixing on the GI bracket of not less than 25mm dia bend to shape as required at site and fixing with nexcessary GI clamps on the wall including connecting up with three core copper cable all as specified and directed.
S&F 1x20W,230V, 6500K CCT surface mounted integral LED batten with extruded alluminium housing with inbuilt electronic driver, polycarbonate diffuser including connecting up with twin core twisted flexible copper condctor cable from ceiling rose to fitting all as specified.
S&F 1x10W,230V, 6500K CCT surface and wall mounted integral LED batten extruded alluminium housing with inbuilt electronic driver and including connecting up with twin core twisted flexible copper condctor cable from ceiling rose to fitting all as specified.
S&F in replacment indoor industrial type recess mounted LED Surface mounted for downlight with white powder coated polycarbonate housing and pressure die-cast heat body with heat sink having high efficiency.15W, 230 V, 50Hz, 6500K CCT, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable as required at site with suitable size complete all as specified and directed
Supply and fixing telephone jack 2 way RJ-11 complete all as specified and directed.
S&F ceiling fan of sweep 1200mm,240volts, of not less than 5 star BEE rating, BLDC dust resistant fan connecting up with three core 1.0 Sqmm cable from ceiling rose including required length of down rod as required at site all as specified.
Supply and Fix air circulator fan 600 mm sweep high speed 230V, 50 Hz incluing fixing arrangement wirth MS bracket frame complete all as specified and directed.
Supply and Fix Pedestal fan 450 mm sweep with high air delivery aerodynamically designed 230V, 50Hz complete all as specified and directed.
M&L for fixing the heavy duty, metallic body exhaust fan of sweep 300mm,single phase 240V, 900 RPM including aluminum louvers and necessary fastner fixing accessoires to fix on any type of wall all as specified and directed.
Material and labour for fixing industrial type sheet metal enclosures Triple pole and neutral with a five pin and earth insulated plug and socket 63 Amps, 415 volts,50Hz complete with all accessaries etc all as directed.
Material and labour for fixing industrial type sheet metal enclosures Triple pole and neutral with a five pin and earth insulated plug and socket 32 Amps, 415 volts,50Hz complete with all accessaries etc all as directed.
Supply and fixing factory made epoxy powder coated Distribution Board TPN 8 way double door (VTPN MCCB DB ) MCCB TPN as In comer, with metal door IP-43 protection, IK-09as per IES-61439-3 fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and 200Amps copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall complete all as specified. Note:MCBs will be measured and paid seperately under respective Sch A item in the schedule
M&L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, GI light grade 15mm dia pipe for earth lead protection including necessary excavation earth work in any type of soil and getting out and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed.
S & F automatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, suitable for 6 kw load single phase comprising of 40 amps MCB , 32 A power contactor and 230 V digital timer switch for controlling street lights, including neccessary fixing arrangement on wall as per site requirement complete all as specified and directed.
EXTERNAL WATER SUPPLY M&L construction of valve chamber of size 600x600x600mm internal size suitable for valves with PCC 1:4:8 type D 2 for foundation and brick masonry wall in cement mortar 1:6 PCC 1:2:4 type B 1 for coping rendering in CM 1:4:15mm thick including Provn of mild steel sheet cover 3.15mm thick on 40x40xx6mm angle iron frame work with two coats of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation earth work all as specified and directed
Cutting of existing GI pipe of size 50 mm dia for taking brach connection and screwing including providing GI fittings as required at site
REFRIGERATION AND AIRCONDITIONING Supply installing, testing and commissioning of 1.5 TR capacity Split type air conditioner unit (Inverter type) 5 star rated complete with drive motor, air cooled condenser with all accessories varied speed and dual rotary compressor, including fixing the outdoor unit with powder coated MS stand/PCC base and fixing of indoor unit on wall including core cutting of required size on type of wall and making good of disturb surface, providing and making interconnection, including refrigerant piping with nitryle rubber insulation and control cable from indoor to outdoor up to a distance of 3.0 mtrs, power cabling (max 3.0 mtrs from isolator/enclosure) to units, first charging non CFC/non HCFC R-32 of refrigerant gas including cord less remote, PVC drain pipe of 25mm dia for connecting drain lines from indoor unit to maximum of 3.0 mtrs to nearest drain points complete all as specified and as directed.
Supply installing, testing and commissioning of 2 TR capacity Split type air conditioner unit (Inverter type) 5 star rated complete with drive motor, air cooled condenser with all accessories varied speed and dual rotary compressor, including fixing the outdoor unit with powder coated MS stand/PCC base and fixing of indoor unit on wall including core cutting of required size on type of wall and making good of disturb surface, providing and making interconnection, including refrigerant piping with nitryle rubber insulation and control cable from indoor to outdoor up to a distance of 3.0 mtrs, power cabling (max 3.0 mtrs from isolator/enclosure) to units, first charging non CFC/non HCFC R-32 of refrigerant gas including cord less remote, PVC drain pipe of 25mm dia for connecting drain lines from indoor unit to maximum of 3.0 mtrs to nearest drain points complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and as directed.
LIGHTNING PROTECTION & EXTERNAL ELECTRIFICATION M & L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth strip 32X6 mm by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore , wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI light grade 40mm dia pipe for earth lead protection including necessary excavation earth work in any type of soil including getting out and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking up of old GI earth plate all as specified and directed.
Steel tubular swaged poles type 410 SP 55 (Overall length 11.00 metre) complete with cast iron base plate, finial taper plug, with necessary bolts, nuts and washers screws, pole shall be painted with two coat of black bituminous paint throughout internally and externally upto planting depth (i.e., embedded portion in ground / concrete) and the remaining external complete pole portion shall be painted two coat of aluminium paint over a coat of red oxide primer, painting of black & yellow alternate strips of 30cm each externally from ground level upto 1.5m with synthetic enamel paint, complete all as specified and directed. NOTE:- Excavation in trenches, PCC in bed concrete, foundation and coping shall be measured and paid separately under respective items of this Schedule.
Supply and Fix Automatic Power Factor Correction (APFC) Panel confirming IEC 61439-1&2 for 3 Phase, 415 V & 50 Hz system of capacity 400 KVAR with incoming MCCB 4P, 630 Amps, 50 KA, Microprocessor controlled, duly with 10% of fixed capacity and 90% of variable capacity in steps operating with 12 steps APFC control module.
M&L for earthing complete with copper plate of size 300x300mm x 3mm thick as earth electrode burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to copper strip 20 x 3 mm as earth lead by means of bolts, nuts, check nuts and washers of copper plate all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the copper earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.
Material & Labour Chemical Earthing, maintenance free with 17.2mm electrode copper coated steel rod 3 mtrs long using 23 kg of powerfill and 9kg powerset compound with brass clamps (earth pit not less than 3.0 M deep below normal ground level) with top edge of the electrode connected to copper earth strip 20x3mm by means of bolts, and nuts check nuts and washers of brass including necessary escavation and earth work in any type of soil, returning and filling, removal of soil to a distance not exc 50 mts, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1, 40MM thick cover with MS rod 8mm dia 150mm long reinforcement all as specified and directed and tested on completion. Make : Jef Techno solutions PVT. Ltd. or equivalent of Indelec or as approved by the GE
Supply & fix HT cable route marker of standard size minimum thickness not less than 5mm thick 100mm dia round, two hole for mounting 3 mm embossed HT cable letter route marker plate and mounted on MS angle 25 x 25 x 3 mm including two coat of enamel paint over one coat of red oxide complete all as specified and directed.
Supply & Laying under ground caution tape red colored for HT UG cable of size not less than 4 inch colour as per standard application wise maximum 1 roll not less than 100 mtr length complete all as specified and directed
Material and Labour for cutting existing road/PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified and directed
Labour for removal and re-laying of HT UG cables laid at site in trenches complete for re-routing all as specified and directed.
Taking down old unserviceable exhaust fan complete all as directed. Note: Exhaust fan obtained shall be deposted to MES store.
Taking down carefully main switches and MCB DB / MCB / MCCBs of any type size and capacity and making good the disturbed surfaces complete all as directed.
UPS Supply, Install, testing and commissioning of UPS (uninterruptible Power Supply) of capacity 10 KVA, 3 Phase, AC, Input 300 to 450 volts, 3 Phase output 415 volts +_ 1%, 50Hz to provide 30 Minute backup complete with suitable battery bank of suitable capacity including cable connections as required for complete system and all as specified and directed. (i) 10 KVA,12 VDC online UPS system which is suitable for 3 : 3 with in built isolation transformer -01 No. (ii) 12 V 65 AH SMF batteries -20 Nos (iii) Suitable MS rack for battery interlink for batteries (with UNINYVIN Cables & 3D Lugs) -01 No.
Indu Electricals
c devender reddy and co
M/s R.L.PAREEK
M/s. P S REDDY
DANDU CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .