Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹11.2 L+₹28,988.01 (2.65%)Rejected-Finance 3RD FLOOR BALAJI POINT OPP MARWARI HOSPITAL ATHGAON GUWAHATI KAMRUP M ASSAM PIN 781001 | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹12.4 L+₹1.4 L (13.0%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹13.5 L+₹2.5 L (23.2%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹13.6 L+₹2.7 L (24.5%)Rejected-Finance BAM GAON SILAPATHAR DIST DHEMAJI ASSAM | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹12.6 L
EMD Value
₹25,200
Closing Date
6 Jul 2020, 6:00 pmClosed
MAJ JYOTI PRAKASH SAHOO
GE 872 EWS C/o 99 APO
PROVN OF HARDSTANDING WITH STORE ROOM IN UNIT AREA AND PROVN OF DRAINAGE SYSTEM ALONGWITH BLDG No. T-73 AT LIKABALI MIL STN UNDER GE 872 EWS(8812/T-12/E8
2020_MES_352633_1
8812/T-12/E8
Open Tender
Civil Works
Item Rate
122 days
LIKABALI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹25,200
Yes
4 Sept 2020
13 Jun 2020
7 Jul 2020
13 Jun 2020
6 Jul 2020
24 Jun 2020
13 Jun 2020 - 18 Jun 2020
Amount
B/R SERVICES/WORKS
Surface Dressing not exc. 15 Cm deep and getting out in Soft/Loose soil, complete all as specified and as directed.
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for Foundation etc. or for Shafts, Wells, Cess Pits, Manholes, Pier Holes, etc. not exc. 10 Sqm on Plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering and Well Ramming in layers not exc. 25 Cm, in Soft/Loose Soil, complete all as specified and as directed.
Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed.
Excavating in Post Holes (or similar Holes) each not exc. 0.50 Cum, getting out, returning, filling in and ramming Earth or Broken Rubble mixed with Earth around, in layers not exc. 25 Cm in Soft/Loose Soil, complete all as specified and as directed.
M&L Sand Filling under Floors or in Foundations including Watering and Consolidation in layers not exc. 15 Cm thick, complete all as specified and as directed.
M&L Hardcore broken Stone or Boulders, gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15 Cm thick, watered and well rammed to a True surface, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (20mm graded stone aggregate) in Surface Channels and Drains, etc. including necessary Use and Waste of Formwork as ordered, complete all as specified and as directed.
M&L Extra for Forming Fair Finished to Drain or Channel of Inner Girth in Cement Concrete with using Extra Cement including Forms, Moulds, Stopped Ends etc., complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Roof Kerbs or Mud Stops, etc., Rounded or Chamfered on Edges, etc. including necessary Use and Waste of Formwork as ordered, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Coping, Bed Plates, Holdfast, Bed Block, Kerb Stones, etc., Weathering, slightly Rounded or Chamfered Angles and Throating including necessary Use and Waste of Formwork as ordered, complete all as specified and as directed.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including necessary Formwork as ordered, complete all as specified and as directed.
M&L Reinforced Cement Concrete M-25 (20mm graded stone aggregate) in Foundation including Rafts, Footing, Foundation Beams for Column Basement Slab, under reamed Piles, complete all as specified and as directed. NOTE : Reinforcement and Formwork will be Measured and Paid for separately under appropriate Items.
M&L Reinforced Cement Concrete M-25 (20mm graded stone aggregate) in Columns, Pillars, Piers, Posts and Struts, etc., complete all as specified and as directed. NOTE : Reinforcement and Formwork will be Measured and Paid for separately under appropriate Items.
M&L Reinforced Cement Concrete M-25 (20mm graded stone aggregate) in Roof Beams, Lintel Bands, Cantilevers, Bressumers, Lintels over 1.50 Metre Span, etc., complete all as specified and as directed. NOTE : Reinforcement and Formwork will be Measured and Paid for separately under appropriate Items.
M&L Reinforced Cement Concrete M-25 (20mm graded stone aggregate) in Chajjas and the like, complete all as specified and as directed. NOTE : Reinforcement and Formwork will be Measured and Paid for separately under appropriate Items.
M&L Pre-cast Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregate) in Landings, Cover Slabs (for Manholes, etc.), Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves and Similar Articles with Plain Faces, set in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Reinforcement will be Measured and Paid separately under respective Items.
M&L Pre-cast Cement Concrete 1:3:6 (20mm graded stone aggregate) Block Masonry with Solid Blocks, exc. 10 Cm in width, Set in Cement Mortar 1:6, complete all as specified and as directed.
M&L Formwork to Sides of Concrete Foundations, Footings, Bases of Columns, Raft and Raft Beams, Sides and Soffits (if any) of Foundation and Plinth Beams and Similar Work; Square, rectangular or polygonal, Vertical or to batter, Flat, Rough Finished surfaces of Concrete, complete all as specified and as directed.
M&L Formwork to Sides of Pillars, Posts, Struts, Piers, Columns and Stanchions, Flat, Rough Finished surfaces of Concrete, complete all as specified and as directed.
M&L Formwork to Sides and Soffits of Floor or Roof Beams, Girders, Beam Haunchings, Bress-summers, Lintels, Cantilevers, Shelves including Supports, Overhangs, etc. also splays between Floors and Beams, etc., Flat, Rough Finished surfaces of Concrete, complete all as specified and as directed.
M&L Formwork to Chullah Hoods, Chajjas, Troughs and Similar Items including Edges, etc., Rough Finished surfaces of Concrete, complete all as specified and as directed.
Taking down Shutter of any description, exc. 1.50 Square Metre but not exc. 4.00 Square Metre Each and Re-fixing in the same Opening including necessary Resecuring or Easing and Adjusting, complete all as specified and as directed.
S&F Steel Windows with Side Hung Shutter including Box type Hinges with Steel Handle and Steel Peg Stays, complete with Glazing Bars, dovetailed or welded, complete all as specified and as directed.
S&F Sheet Glass 3.0mm thick, Plain, Ordinary quality and Glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane, complete all as specified and as directed.
M&L TMT Bars 8.0mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed.
M&L TMT Bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed.
M&L TMT Bars 8mm dia in Stirrups, Spacers and Binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and as directed.
M&L Rolled Mild Steel in Joist, Channel, Angle, or Tee Sections, fixed independently, without Connecting Plates, etc. (cut to ordinary lengths i.e. within 20mm of the Length indicated), conforming to Fe-410-W (Gde E-250), Quality B, complete all as specified and as directed.
M&L Rolled Mild Steel in Roof Trusses (Framed), Trusses, Purlines, Crane Gantries, Rails and Fastening and Heavy Bracket Framing (Beam, Tee, Angle, Channel or Flat Sections) including Distance Pieces, Cleats, etc, welding or riveted, conforming to Fe-410-W (Gde E-250), Quality B, complete all as specified and as directed.
M&L Mild Steel Framed Works such as Grills, Gratings, etc. with Ends of Bars shouldered and/or riveted or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walkways; Railings; Framework of Water Tanks and similar Work, conforming to Fe-290, Gde-E-165, complete all as specified and as directed.
M&L Mild Steel Screw Bolts (Machine made) with Hexagonal or Square Heads at One End and screwed the Other, or screwed Both Ends, Each screwed End to be fitted with Washers and One Hexagonal or Square Nut, Length of Bolt exc. 5.0 Cm but not exc. 10 Cm and Diameter of Neck 11mm to 15mm, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Corrugated Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Plain Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Ridges/ Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) 100mm thick in Sub-base to Flooring, Pavings, etc., finished Concrete Surfaces Fair and Even, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) 40mm thick in Floors, etc., Laid in Alternate Panels, finished Concrete Surfaces Even and Smoooth without Using Extra Cement, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (40mm graded stone aggregate) 100mm thick in Floors, etc., Laid in Alternate Panels, finished Concrete Surfaces Even and Smoooth without Using Extra Cement, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (20mm graded stone aggregate) 75mm thick in Plinth Protection, etc., Laid in Alternate Panels, finished Concrete Surfaces Even and Smoooth without Using Extra Cement, complete all as specified and as directed.
M&L Plastic Dividing Strips 38x1.5mm thick, inserted in Floor to confirm design, complete all as specified and as directed.
M&L Roughening Surfaces of Old Concrete Floor by Picking, Sweeping Clean and Washing down with Water to remove Dust, etc., and Brushing with Neat Cement Slurry @ 3.0 KG/SQM on Cleaned Concrete Surfaces, complete all as specified and as directed.
M&L Non-skid Ceramic Coloured Tiles 7.0-8.0mm thick (square/rectangular) area of Each Tile exc. 0.11 Sqm but not exc. 0.18 Sqm (1st quality) conforming to IS:13755, in Floors, jointed in Neat Cement Slurry and pointed in Coloured Cement to match the Tile, laid over and including Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate
M&L Rendering (Internal) 15mm thick in Cement Mortar 1:6 on Brick/ PCC Blocks or Concrete Works, finished Plastered Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L Rendering (External) 15mm thick in Cement Mortar 1:4 on Brick/PCC Blocks or Concrete Works, finished Fair and Even, complete all as specified and as directed.
M&L Rendering (External) 15mm thick in Cement Mortar 1:4 on Brick/PCC Blocks or Concrete Works including mixed with WPC, finished Fair and Even, complete all as specified and as directed. NOTE : Water Proofing Compound (WPC) will be Measured and Paid saperately under appropriate Item.
Supply only Water Proofing Compound (as approved), conforming to IS:2645-2003, complete all as specified and as directed.
M&L Preparing Newly Plastered Surfaces of Walls and applying Three Coats of White Wash, complete all as specified and as directed.
M&L Preparing Newly Plastered Surfaces of Walls and applying Two Coats of Cement Based Paint over a coat of Alkali Resistant Priming Paint, complete all as specified and as directed.
M&L Preparing Steel and Iron Surfaces of any descriptions, over exc. 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
S&F PVC (SWR) 110mm bore (dia) Pipe, Single Socketed, in any length with Rubber Ring Joints, laid in Trenches/Floors or fixing to Walls, complete all as specified and as directed.
E/M SERVICES/WORKS
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/ FAN/ BELL POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including ERW Rigid Steel Conduit (Stove Enamelled) of suitable size (approx 20mm dia), ISI Marked along with all Fitting/ Fixtures as Flame Proof Bend, Flame Proof Junction Box, Flame Proof Reducer, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT POINT controlled by One MCB on INDEPENDENT BOARD, complete all as specified and as directed. NOTE : Cost of Flame Proof Junction Box 2-way suitable for ERW Rigid Steel Conduit 20mm dia shall deem to be include in the Quoted Unit Rate.
S&F Switch Flame Proof Rotary type with Termination Box in Cast Aluminium Alloy (LM6) Construction, Epoxy Powder coated, 16 Amp, Single Pole, ON/OFF type, 250 Volt AC, Certified by CRMI Dhanbad for Group II A & II B including Compression Glands, complete all as specified and as directed.
S&F Ceiling Rose 65x50mm, 3 Terminals, Surface Bakelite suitable for 230 Volt AC and connecting up, complete all as specified and as directed.
S&F LED Bulk Head Light Fitting 1x10 Watt having Plastic Housing with Clear Prismatic Diffuser LED 10 Watt Lamp and connecting up with and including suitable size Twisted Flexible Copper Conductor Cable, complete all as specified and as directed. MAKE : C&S, Cat No. CG80IB10WLED or equvalent in Make : BAJAJ/ CROMPTON/HAVELS/PHILPS (as approved by GE)
S&F Flame Proof Weather Proof LED Tube Light Fitting 1x36 Watt (4 Feet) with LED Tube Light suitable for PE/EXLED/904236 including Integral Reflector made of Aluminium Die-cast Alloy LM6 of Gas Gr. II A, II B, Certified by CRMI Dhanbad with Electronic Ballast, Bipin Holder, Connector Block, etc. all Accessories Pre-wired, Elecrically Connecting up with and including suitable size Twin Core twisted Flexible Copper Conductor, complete all as specified and as directed.
S&F MCB Single Pole 6 Amp to 32 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up, complete all as specified and as directed.
S&F MCB Single Pole & Neutral 40 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up, complete all as specified and as directed.
S&F MCB Distribution Board Sheet Metal Enclosure, SPN, 4-way, 240 Volt with 200 Amp rated Neutral Bars & Earth Bar, Double Doors, flush with Wall Inside the Nitches or Outside on Wall Surface, suitable for mounting Isolators & MCB's, etc. and connecting up, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Laying of Cables, etc., Forming Surfaces to required Foundation, etc. and getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, providing Heaps along the Route of the Cable Line with Surplus Soil (if any) in Soft/Loose Soil, complete all as specified and as directed.
Supply & Laying LT UG XLPE insulated, PVC sheathed, heavy duty, armoured with multi-stranded Aluminium Conductor Cable, 1100 Volt grade, conforming to IS:7098 (Part-I) 1998, Cross-sectional area 10 Sqmm, 2 Core, laid in Trenches, Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand Cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Unreinforced Pre-cast Concrete Cable Cover of size 300x180x40mm thick, Class LV, Type 2, Flat, Concrete grade M-20 minimum, complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
Sunwin Energy and Infra Pvt Ltd
LALIT DOLEY
AFTAB ENTERPRISES
M/S Raju prasad
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .