Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-Finance | ₹24.0 L | L1 | Accepted-Finance BEING LOWEST |
| 2 | L2₹24.1 L+₹12,530 (0.52%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | ₹24.1 L+₹12,530 (0.52%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | Rejected-Technical 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | - | - | Rejected-Technical NO IN WLR |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
8 Jun 2020, 6:00 pmClosed
GE A Jaisalmer
Jaisalmer
REPAIR AND MAINT OF CEILING FAN, EXHAUST FAN, HEATING APPLIANCES, SOLAR APPLIANCES UNDER THE JURISDICTION OF GE (A) JAISALMER
2020_MES_343921_1
8919/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
REPAIR AND MAINT OF CEILING FAN, EXHAUST FAN, HEATING APPLIANCES, SOLAR APPLIANCES UNDER THE JURISDICTION OF GE (A) JAISALMER
7 documents required · 7 mandatory
₹500
Yes
GE A Jaisalmer
₹60,000
Yes
28 Jul 2020
11 May 2020
10 Jun 2020
11 May 2020
8 Jun 2020
25 May 2020
Amount
Note :-The quoted rates shall deemed to be included for the following : (a) As the above work is required to be carried out for rectifying day to day E/M nature compliants, the following term and conditions shall be applied (b) Hence the contractor shall have to employee adequote manpower not less than 2 elects & 2 helpers to attend and rectify all the complaints/defects received in a day on same day. (c) A creadit rep of contractor shall report daily at service centre to concern JE E/M or Engr -in- Charge and receive job card/complaint slip for repair/replace the items on same day failing which the panalty shall be imposed and recovered as under :- (i) Non reporting of trademen : 300/- per elect /day Helper 200/- per helper per day (ii) Non attending the complaints to with in 24 hrs 30/- per complaints per day shall be recovered. (b) The contractor shall depute adequate trademan/ helper to repair/ replacement of u/s parts and attending the day to day complaints received from user on daily basis but not less than 2 Electrician and 2 helper per day.
Attending the complaints of non functional of ceilling/exhaust fan/Wall fan of any sweep and testing and repairing the ceilling/exhaust fan/Wall fan without taking down by replacing of fan condencer, fan regulator and connection wire etc. and making fan serviceable all as directed. (NOTE- Item such as fan condenser, fan regulator, 1.5 sqmm, 3 core copper flexible cable shall be measured and paid seperataly as 'Supply Only')
Supply only following items:-
(a) Fan condencer, 2.5 Mfd, 240 volts for ceiling/Exhaust fan including PVC clamp Make: Epcos, Bajaj, Havells, CG.
(b) Fan condencer, 4 Mfd, 240 volts for ceiling/Exhaust fan including PVC clamp
(c) Fan regulator electronic Modular step type, 120 watts, 1 module/2 module
(d) Fan regulator electronic switch type / socket type 120 watts,
(e) Supply only for rubber reel insulator, 3 Nos nut bolt , washer and lock pin complete all as specified and as directed.
(f) Ceiling fan blade
(g) Exhaust fan blade any size any type
(h) Ceiling fan fastner for fixing fan
(j) Ceiling fan downrod suitable size with GI Hook as per requirement of site of any size
Taking down ceiling fan / Exhaust fan of any sweep sealing cable end dismanting blade and removing fan and blade to store complete all as specified and as directed.
S&F in repairs for ball bearing suitable for ceiling fan complete all as specified and as directed. Make : SKF/NBC/TATA
S&F in repairs for ball bearing suitable for exhaust fans complete all as specified and as directed. Make : SKF/NBC/TATA
S&F in repairs for brass GM bush suitable for fan any sizecomplete all as specified and as directed
M & L for rewinding of ceiling fan of any size with supper enameled copper wire of existing gauge including varnishing and drying complete reassembling & testing complete of following size complete all as specified and as directed.
(a) Ceiling fan 1200/1400 mm Sweep
(b) Exhaust Fan 250/300/380 mm
(c) Exhaust Fan 400/450 mm
(d) Exhaust Fan 600 mm
(e) Wall mounted fan 400 mm Sweep
(f) Air circulater 600 mm sweep
M & L for Painting of ceiling fan/ Exhaust fan complete in situ with synthetic enamel paint by spraying including filling cavity with filler one coat after cleaning all dust etc complete all as specified and as directed.
Fixing only Ceiling fan and connecting up including provn of cable from ceiling rose or connector to fan complete all as specified and as directed.
Fixing only exhaust fan/Wall Mounting/Air circulater and connecting up including provn of cable from ceiling rose or connector to fan complete all as specified and as directed.
M & L for making of bearing cover housing as per fan shaft diameter of any type and size of ceiling fan and fixing at ball bearing in place of bush of required size by means of lathe machine (ball bearing shall be measured & paid separately)
Taking down storage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25/50 ltrs of any type and make, in MES store Yard complete all as specified.
Refixing storage type water heater, checking the serviceablity of all parts such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly completet (considered as one unit) and installing and testing the same as per the direction of Engineer-In-Charge.(Supply only for parts against unserviceable parts shall be measured and paid for separately under relavent items given below)
S&F in repairs for replacement of heating elements, 1.5 KW ISI mark 230 volts complete all as specified and directed. (Make -THEETA/Hotmax)
...Ditto... All as per serial item No.15.00 above but 2 KW complete all as specified and directe . (Make -THEETA/Hotmax)
S&F in repairs for replacement of thermostat immersion point type 15 Amps, 230 volts/AC ISI marked complete all as specified and directed. (Make - Elcon/Hotmax)
S&F in repairs for replacement safety valve ISI marked complete all as specified and directed
S&F in repairs for replacement of pressure realizing valve of size 15 mm dia complete all as specified and directed
S&F in repairs for Metal clad plug top, 3 pin, 20 Amps complete all as specified and directed (Make: ABB, Legrand, C&S)
S&F in repairs for Metal clad socket 20 Amps complete all as specified and directed (Make: ABB, Legrand, C&S)
S&F in repairs for Three pin plug top, 16 amp capacity, 240 VAC, heavy duty, ISI marked complete all as specified and directed. (Make : Anchor, Cona )
S&F in repairs for MCB SP 16 Amps single pole, 230volt, 50 Hz Complete all as specified (Make Legrand, ABB, Schneider)
S&F in repairs for Fastners screw for fixing Geyser complete all as specified and directed
S&F in repairs for replacement of PVC flexible conneciton pipe with brass check nuts suitable for geysers HOT/COLD water pipe complete all as specified and directed by Engineer-In-Charge.
S&F in repairs for replacement of indicator lamp assembly for geyser complete all as specified and directed by Engr-In-Charge.
S&F in repairs for replacement of 3 core PVC insulated and sheathed cable with copper conductor of size 40/0.076. Make - Plaza/National complete all as specified.
S&F in repairs for replacement of inlet & outlet assembly plate suitable for 25 ltrs capacity geyser as per existing pattern complete all as specified and directed by Engr-In-Charge.
...Ditto... all as per serial item No.28.00 above but 50 ltrs.
Dismantling & taking out the unserviceable gunmetal non returen valve/stop valve 15 mm dia from geyser connection pipe complete all as specified and directed by Engr-In-Charge.
S&F in repairs for Inner tank of geyser of 25 Ltr capacity of made out of steel tank in replecement of leakage tank of geyser complete all as specified
...Ditto... all as per serial item No.31.00 above for 50 Ltr.
S&F in repairs for gun metal non return valve 15 mm dia including making proper connection complete all as specified and directed by Engr-in-Charge.
S&F in repairs for STOP COCK cast copper alloy, screwed down high pressure screwed both ends for iron pipe of 15 mm bore fancy type chromium plated complete all as specified.
Dismantling old defective solar water heater collector of any type any make complete all as directed.
Taking down of hot water tank of any capacity any make complete all as directed by Engr-In-Charge.
S&F in repair MNRE registered/ approved stainless steel hot water tank with inner tank material SS 304L with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation suitable for tank volume of 200 Liters complete with backup heater option 2 KW all as specified and directed by Engr-In-Charge. (Make: V-Guard, Havells, Greentek, Jain Solar, Nilloy, Emvee)
S&F in repair MNRE registered/ approved stainless steel hot water tank with inner tank material SS 304L with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation suitable for tank volume of 150 Liters complete with backup heater option 2 KW all as specified and directed by Engr-In-Charge. (Make: V-Guard, Havells, Greentek, Jain Solar, Nilloy, Emvee)
S&F in repair MNRE registered/ approved stainless steel hot water tank with inner tank material SS 304L with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation suitable for tank volume of 100/125 Liters complete with backup heater option 2/1.5 KW all as specified and directed by Engr-In-Charge. (Make: V-Guard, Havells, Greentek, Jain Solar, Nilloy, Emvee)
S&F in repair MNRE registered/ approved ISI marked 100LPD capacity Evacuated tube collector (ETC) type 1800 / 2100mm long tubes with inner dia 47mm and outer dia 58mm with frame and frame angle 30 degree complete with electric backup of 1.5 KW and stainless steel hot water tank with inner tank material SS 304L with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation suitable for tank volume of 100 Liters complete with minimum one year warranty complete all as specified and directed by Engr-in-Charge. (Make: Havells,Racold, V-Guard, Jain Solar, Emmvee)
S&F in repair MNRE registered/ approved ISI marked 150LPD capacity Evacuated tube collector (ETC) type 1800/2100mm long tubes with inner dia 47mm and outer dia 58mm with frame and frame angle 30 degree complete with electric backup of 1.5 KW and stainless steel hot water tank with inner tank material SS 304L with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation suitable for tank volume of 150 Liters complete with minimum one year warranty complete all as specified and directed by Engr-in-Charge. (Make: Havells, Racold, V-Guard, Jain Solar, Emmvee)
S&F in repair MNRE registered/ approved ISI marked 200LPD capacity Evacuated tube collector (ETC) type 1800/2100mm long tubes with inner dia 47mm and outer dia 58mm with frame and frame angle 30 degree complete with electric backup of 1.5 KW and stainless steel hot water tank with inner tank material SS 304L with outer cladding of painted & oven baked pre coated galvanised sheet, insulated with 40mm thick high density PUF insulation suitable for tank volume of 200 Liters complete with minimum one year warranty complete all as specified and directed by Engr-in-Charge. (Make: Havells,Racold, V-Guard, Jain Solar, Emmvee)
Taking down of rusted MS structure of any type any shape complete all as directed by Engr-In-Charge.
S& F strong and durable MS anti corrosive painted outer cladding/ frames and support/mounting structure for hot water and cold water tanks/piping and FPC complete of capacity upto 200 LPD fabricated out of size 50*50*4mm thick MS angle and bottom piece of MS plate 2.0 mm thick and fixing mounting bed support bolts including and forming PCC work and 12mm thick etc complete to avoid any deformation complete all as specified and directed by Engr-In-Charge.
Taking down old U/S , broken pipe of any type any size complete all as directed by Engr-In-Charge.
Supplying and laying in repair of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete of size 20mm including union, bends and tees complete all as specified. Make: Astral, Supreme
S&F in repair, heating element for solar water heating system of capacity 3 KW ISI marked complete all as specified & directed by Engineer-in-charge. (MAKE : BAJAJ, REOLD, SPHERHOT)
S&F in repair, the thermostat suitable for 100/200 litres capacity of solar water heater complete all as specified & directed by Engineer-in-charge. (MAKE : BAJAJ, REOLD, SPHERHOT)
S&F in repair, Gun-metal, globe or gate valves, with iron wheel head ,screwed both ends from iron pipe and fixed size 15 mm complete all as specified & directed by Engineer-in-charge. (Make: Vir/Leader/Kirloskar)
…Ditto… All as per Serial Item No 52.00 above but size 20 mm (Make: Vir/Leader/Kirloskar)
…Ditto… All as per Serial Item No 52.00 above but size 25 mm (Make: Vir/Leader/Kirloskar)
S&F in repairs for rotational moulded synthetic (HDPE) water storage tank 500 litre capacity ISI marked double layered, cylindrical vertical with closed top hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed.
S&F Galvanised iron pipe medium grade 20 mm bore ISI marked with necessary fittings such as tees, elbows, bends, reducers, union etc fixed along wall/floor/roof incld covering with insulation all around with 25mm thick bonded mineral wool preformed 'SNAPON' pipe sections of density 144 KG/Cum conforming to IS 9842 as directed of rock wool/mineral wool, chicken mesh and cladding with 26 SWG alum sheet incld chasing/cutting of wall as required complete all as specified and directed by Engr-in-charge.
Rasam Engg Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .