Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 CrAccepted-AOC | ₹7.1 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹8.7 Cr+₹1.6 Cr (22.9%)Rejected-Finance 54 AKASH DEEP COLONY CHAKRATA ROAD DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹8.7 Cr+₹1.6 Cr (22.9%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹9.2 Cr+₹2.1 Cr (30.3%)Rejected-Finance RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹9.2 Cr+₹2.1 Cr (30.3%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹9.4 Cr+₹2.4 Cr (33.3%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹9.4 Cr+₹2.4 Cr (33.3%) | L4 | Rejected-Finance Not Being L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Work Experience in the relevant field not submitted and The bidder has stated in their letter dated 28 Nov 2024 that they do not have experience for such work |
Tender Value
₹9.3 Cr
EMD Value
₹7.9 L
Closing Date
12 Nov 2024, 6:00 pmClosed
Chief Engineer
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
PROVN OF RCC DRAIN CONNECTING VARIOUS UNITS TO FAZALPUR DRAIN AT MEERUT CANTT
2024_MES_672314_1
CEBZ/MRT/T-20 OF 2024-25
Open Tender
Civil Works
Lump-sum
365 days
Meerut
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE South Meerut
₹7.9 L
Yes
2 Jan 2025
5 Sept 2024
19 Nov 2024
5 Sept 2024
12 Nov 2024
28 Oct 2024
Amount
Total amount of Sch 'A' Part I Building Work) (For details see Sch 'A' in PDF folder)
Total amount of Sch 'A' Part II Internal Water Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE A PART III (INTERNAL ELECTRIC SUPPLY)
M & L for point wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed steel terminal box for mounting fittings i.e, modular switch / sockets incl cover plate with frame and covered with 3 mm thick white bakelite / laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: -
(a) One light point point /bell buzze/ ceiling fan/Exhaust fan point controlled by one-one way switch.
(b) One three pin 5 Amp socket on same board with other switches.
(c) One three pin 5 Amp socket on independent board
All as per item No-4 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm.
Supply and fixing modular switch 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed.
Supply and fixing modular socket outlet 5 pin, 05 / 06 Amps flush type 240 volts complete all as specified & directed.
Supply & fixing of modular socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed .
Supply and fix in modular switch 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed.
Supply & fixing lamp holder (Angular / Straight), insulated body, with back plate complete all as specified and directed.
Supply and fix modular blanking plate on the existing modular plate & switch box excluding modular plate as required complete all as directed.
Supply and fixing ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified
S & F 125 Amp, 415 Volts four pole MCCB adjustable type with breaking capacity 16 KA and incl connections, testing and commissioning complete all as specified and directed.
Supply and fixing of MCB TPN, 100 Amps, 415 Volt,10 KA 'C' curve complete all as specified and directed.
S&F DB TPN, 415 volt with 250 amps rated copper bus bar for double door 4 way IP-54, IK-09 suitable for one MCB as incoming and MCB TPN as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
S&F DB SPN, 240 volt with 200 amps rated copper bus bar for double door 12 way IP-43, IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
S&F DB SPN, 240 volt with 200 amps rated copper bus bar for double door 04 way IP-43, IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
S&F MCB SP, 5 to 32 Amps,240 Volt 10 KA 'C' curve conforming to ISI marked complete all as specified & directed .
S&F MCB SPN, 40 to 63 Amps,240 Volt 10 KA 'C' curve conforming to ISI marked complete all as specified & directed .
M&L sub main wiring in replacement with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 1.5 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 1.5 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
M&L sub main wiring in replacement with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 2.5 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 2.5 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
M&L sub main wiring in replacement with 4 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 16 Sq.mm. (nominal area) drawing in and including 25 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 16.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
Supply & fixing LED light fitting 1x20 watt, 220 volt AC decorative box type with driver, holders, including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed.
Supply & fix LED light fitting high out put diffuser 2 feet, 10 watt, 220 volt AC decorative type with driver, holders, including LED lamp connecting up with three core flexible copper conductor of suitable size complete all as specified and directed.
Supply & fix LED lamp 12 watt, 220 volt AC decorative type connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and directed.
Supply and fix exhaust fan steel body AC single phase 230 V of size 300 mm sweep with blades and frame and louvers
Supply and fix exhaust fan steel body AC single phase 230 V of size 450 mm sweep with blades and frame and louvers
Supply and fixing BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories of suitable capacity upto 50W 230 Volts, 1200 mm sweep, min air delivery 245 CFM five star rated with squirrel cage induction motor complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 miters below normal ground level, connected to galvanised earth lead strip 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Supply and fixing of earth continuity conductor or main earthing lead of size 25x4 mm , GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles/wall or any other indicated situation for loop of earthing etc. complete all as directed.
Supply, installation, testing and commissioning of Water Heater Storage Type five star rating, electric suitable for single phase ,50HZ, AC supply, stainless steel inner assembly, 2 KW heating element, Twin thermostat for water temperature and safety thermostat stove enamel outer body including minimum 1M of three core 2.5 sq mm twisted copper conductor cable PVC sheathed, three pin plug top, polyethylene pipe connection piece 450mm long of 6Kg/sq,CM with two sets of chromium plated adopter at each end suitable for 15mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopter at ends, at hot water outlet, with safety fusible plug confirming to relevant IS of 25 ltrs capacity.
Supply, fix, connecting and testing building LED security light fitting 35 W with pressure die cast aluminium housing, heat resistant toughened glass, IP 66 protection and impact resistance of IK 07 with 10KV Built-in Surge Protection Device, better optics for uniform distribution compete with electronic driver, including connecting up with three core copper conductor cable with 1.5 sqmm size copper wire from ceiling rose to connector of light fitting complete all as specified and directed.
Total amount of Sch 'A' Part IV Site Clearance) (For details see Sch 'A' in PDF folder)
Total amount of Sch 'A' Part V A, Area Drainage) (For details see Sch 'A' in PDF folder)
SCHEDULE A PART V B ( AREA DRAINAGE)
Supply installation, testing and commissioning of MS sliding type gate valve manual gear operated with hand wheel for opening size 1200X1200 mm with frame consisting of MS Channel 65X125 mm with hold fast, sealing frame, stiffeners, horizontal and vertical girders, guide, stainless steel flat/ Brass flat, rivets, wedges, gear assembly, lifting rod of SS 410 grade etc, with all accessories as per drawing attached as Annex-I including MS Channel frame & MS gate of 14 mm thickness complete set for Drain work including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, seal fixing, tools and tackles etc and applying two coat of zinc rich epoxy primer to give dry film thickness of 65 microns and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 145 microns per coat, complete as per specifications and directed by Engineer-in-Charge.
Supply installation, testing and commissioning of MS sliding type gate valve manual gear operated with hand wheel for opening size 2400X2000 mm with frame consisting of MS Channel 75X150 mm with hold fast, sealing frame, stiffeners, horizontal and vertical girders, guide, stainless steel flat/ Brass flat, rivets, wedges, gear assembly, lifting rod of SS 410 grade etc, with all accessories as per drawing attached as Annex-I including MS Channel frame & MS gate of 20 mm thickness complete set for Drain work including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, seal fixing, tools and tackles etc and applying two coat of zinc rich epoxy primer to give dry film thickness of 75 microns and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 microns per coat, complete as per specifications and directed by Engineer-in-Charge.
SCHEDULE A PART VI ( EXTERNAL WATER SUPPLY)
SITC of submersible pumpset cast iron body, SS shaft rating 450 cum/empar 370mm dia, 10m head amarex KRTE 200-401, n=960 rpm Motor 18kW 415V, 3 phase,50Hz AC supply, including 20RM, 8 core cable, complete as required. Note: Cable starter panel to motor with motor including controlcable and float for dry condition and auto on and stop.
M & L for providing lowering in trenches, laying and jointing ductile iron pipe (K-9), socket and spigot end, as per specifications (IS-8329) with internal cement mortar lining and external bitumen coating for portable water supply with rubber ring joints, including cost of rubber rings as per IS:5382 (1985), giving satisfactory hydraulic field testing and commissioning as per Technical specification etc complete of 300mm dia complete all as specified and directed.
Cutting to existing CI/DI/GI pipe line in position upto 300/ 200/150mm dia for insertion of and including new GI /CI/DI Tee, branches, collar, including jointing material etc complete all as specified and directed.
Supply, fixing and testing of cast iron body sluice valve flanged ends, drilled, having stainless steel spindle (ISI marked) suitable for 300 mm bore pipe line, class PN 1.60 with non magnetic , conforming to IS-14846 to 2000 with and including all accessories such as nut-bolts, washers & fibre / rubber gasket as required at site complete all as specified and directed.
M & L for construction of brick masonry valve pit of size 950 X 950 X 950 mm (outer dimensions) with excavation & earthwork in any type of soil, brick work of fly ash old size bricks built in cement mortar 1:4, PCC 1:2:4 type B-1 as in foundation concrete, bed/floors, coping and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces, external plaster shall be upto 15 cm below GL and mixed with water proofing compound @ 2% by weight of cement with and including 40 mm X 40 mm X 6 mm mild steel angle iron frame, 3.15 mm thick mild steel sheet cover with appropriate size lifting handles and locking arrangement and 01 No. 50 mm size 4 levers lock with keys in duplicate make Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawings and as directed.
M&L for ductile iron special and fittings for spigot and socketed pipes for water mains / branches lines such as bends(any type radious and angle ) tapers any type (straight, bend,increasing,decresing,or double socket etc) tee pices, single branch ,Y juntion, double branch,cross(all socket ,socket and spigot) collers,caps&plugs, including connecting pieces one end flanged and other socket or spigot and bell mouth pices suitable for rubber joint/run lead joint, up to 300mm bore complete all as specified and directed. Note :- All excavation and earth work as involved in this schedule shall be measured and paid under external electric supply schedule items.
Total amount of Sch 'A' Part VII A External Electric Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE A PART VII B (External Electric Supply)
Supply, installation, testing and commissioning of 11 KV RMU, rated voltage 12 KV, 630 A, 21 KA/3 sec, outdoor type, non extensible, Inter ARC 21 KA for tank, floor mounted with internal copper bush bar, SF6 insulated ocmpletely motorised, 3 way RMU consisting of 01 No VCB as incommer and two No load break switch as outgoing with SCADA compatable overload and earth fault protection Relay (Ashidha/ CSPDR) with air insulated Metering module (MFM for VCB Feeders). All live parts, bush bars, LBSs conections of RMU shall be enclosed in one SF6 tank to avoid multiple interconnections. SF6 Tank shall be sealed for life robotically welded non magnetic and non fenile sainless steel Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filed with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. No Fault unit shall have front cable (Suitable for termination of 1R X30CX95.120/150 Sqmm Cable) for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. RMU should be complete with all accessories such as terminal boots, VPIS, cable supports, all front cable terminations. mechancial indications for Load break swithc ON/ OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external bus bar. Also, the outer enclosure shall cover the full length of the switchgear, to ensure IP3X+IP54 protection for cable boxes. The unit shall be internal arc proof 21 KA for 1 sec with AFLR classification teted and totally safe for human beings. The gas releae & personel safety from internal arc shall not depend on plinth design. The release of the gas to be from the top of the unit, so tha,t even if the person is operating the unit, opening the cover, & there are personnels near the sides of the RMU/ plinth, top release will ensure their safety. The hot gas release, in case of internal arc, if no case should be from any side or bottom of the unit. Bidder shall provide type test report to prove compliance to the Internal Arc fault IAC-AFLR as per IEC 62271-200, Internal arc testing shall be done with enclosure door in open condition, with switching devices in operation mode as per specifed and directed by Engr-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through outdor termination heat shrink type complete with jointing material and accessories suitable for 3.5 core XLPE armoured AI conductor cable of size 185Sqmm.
"Material and labour for shifting, installation, testing and commssioning of existing transformer of capacity 63 KVA step down outdoor type copper wounded 11/0.433 KV from MES yard Meerut to proposed pump house complete all as specified and directed at site. Note 1: Rate included for PCC platform as per manufacturer recommendations. 2. Rate quoted against this items shall be deemed to include required manpower, tools and plants and vehicle for satisfactory completion of the job.
Supply and install APFC Panel for 3 phase,415V & 50Hz system of cap. 50KVAR without incoming MCCBs.
M & L for supply & fix dropout fuse unit consisting of fized & moveable insulators with expulsion fuse single pole 11000 Volts above 25 & up to 50Amps capacity mounted one & including common MS channel complete all as directed.
Supply, installation commissioning and testing HT 11 KV out door type gang operated air break switch outdoor type, triple pole suitable for vertical mounting complete with MS channel of size 100 x50mm, suitable clamps, MS bolts, nutswashers with operating mechanism worked from ground level, current rating 200 Amps complete with locking arrangement, fuse unit type carriers, fuse element of required capacity and switch having 11 KV 3 phase including connecting with OH & HT UG cable all as specified and directed.
Supply installation testing and commissioning of LT feeder pillar box (KIOSK) type totally enclosed made of MS sheet 3.15 mm thick outdoor type weather proof having sloping canopy with both side openable, locking arragement and painting etc (factory made) comprising the following:- (i) Incoming MCCB 200 Amps 4 pole 415 volt 50 KA -1 No. (ii) Outgoing MCCB 100 Amps TPN 415 volt 36 KA -3Nos (01 spare) (iii) Busbar aluminium 200Amp with insulated for TPN. (iv) Indicator lamp LED type - 3 Nos. (v) Panel wiring with 2.5 Sqmm copper cable PVC single core -1 Job. (vi) PCC plateform with foundation 1:2:4 = 1 job.
M&L for pole box fabricated out of 1.8mm MS sheet having 3 nos busbar 50 Amp copper conductor mounted on insulators one no 20x3 copper bus bar with 2 clamps of copper strip for earthing of the armoured of the cable complete with making holes for connecting cables etc nuts blots etc size of box not less then 100x200x80mm front openable hinged cover suitable for mounting on steel using clamps nut bolt etc pvc adopteers and PVC hose pipe upto clamps trench for incoming and outgoing cables, factory made duly painted with powder coating process complete all as specified and directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S Clamps, bolts and nuts of approved size for HT 25x20cm size.
Boring of Hole under road , pavement , hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitabe for 0.4 Mpa working Pressure .
Supply and fix cable jointing kit for 11 KV grade cable for outdor termination heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured AI conductor cable of size 95 Sqmm.
Steel tubular swaged poles complete with cast iron base plate, finaial taper plug, bolts, nuts and screws as specified type 410SP-22(11.00Meters) long.
Supply and laid (GI light grade tube ) in under Road/drain/cullvert fixed to poles wall with flat Iron clamps bolts nuts and washerts of 100 mm size complete all as specified and directed
Supply and laid (GI light grade tube ) in under Road/drain/cullvert fixed to poles wall with flat Iron clamps bolts nuts and washerts of 50 mm size complete all as specified and directed
M&L river washed and screeened dry fine sand filling in trenches below and above / around under ground cable for cable protection including punniing around cable complete all as specified and directed. (Note: Punned thickness shall only be be measured for payment purpose.)
S & F lightening arresters, expulsion complete with all fittings, transmission class 11000 volt grade, discharge capacity 65 Kilo Amps complete all as specified and directed.
S&F of automatic street light timer switches 250V single phase of 20 Amp. Rating with contractor fitted inside steel enclosure.
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete.
M&L for Weather proof flat twin core aluminium cable conductor of size 2.5 Sqmm for connection of Securiry light to OH or Pole Box all acomplete as specified and directed.
LT Panel:(Indoor type)Fabrication , supply & Fixing, installation, testing and commissionins of cubicle type floor mounted main distribution Board panel made out of 2mm thick CRCA sheet including connection, inter connection alongwith 4 strip aluminium bus bar as per MES specifications and IS : 8623 comprising of followings panel mounting switchgears etc. as required as per spefication. (i) MCCB 4 Pole 160 Amps, 25KA - 01 No (for incoming) Make:Legrand/L&T/Siemens/ABB/C&S/GE/Schneider (ii) MCCB 4 Pole ,100 Amps, 25KA (for outgoing) -02No. with thermal magenetic release for O/C, & S/C Protection. Make: Legrand/L&T/Siemens/ABB/C&S/GE/ Schneider (iii). CT operated of Multi functional three phase digital meter (LCD) display type in size(96 x 96) sq mm - 01 Set(100amps) (iv). Phases Indication & ON/OFF Lamp with control fuse - 01 Set. (v). Aluminum Busbar 200 Amps TP & N(BPTM type heast - strinkable busbar insulation) supplorted by DMC/FRP insulators. (vi). MCCB TP 63Amps - 04 Nos with thermal magenetic release for O/C & S/C Protection. (vii). Star deltal starter automatic and manual suitable for 415V AC for 16 KW Motor - 02 Nos. (viii). Ammter with 3Nos. 30/5A, CL-1 CTs as reuired - 04Nos. (ix). LED ON/OFF Trip indication Lamp with 2A SP MCB - 04 Sets.
Supply & fixing of Cable route markers made of galvanized iron with supporting GI angle of size 40 X 40 X 6 mm for stand and plate size 150X150X5mm thick and primering, painting, writing of HT/LT cable route mark for suitable size letters including M/L PCC 1:3:6 type C2 using 40mm graded aggregades in mass concrete or plinth block complete all as specified and directed.
Construction of open plateform with rail, resting for transformer complete with fencing and steel gate etc complete all as specified and shown on drawing. (Ref TD-156).
S&F ACSR conductorany type for transformer connectivity.
Material and labour for earthing of machiner/equipment (Transformer, RMU & feeder Pillar box,) Installed at power house/substation, using 32 x 6mm GI MS strip with galvanised steel earth plate electrided 600 X 600 X 6 mm thick buried in ground (earth pit not less than 2.25 mtr depth below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI MS strip 32x6 mm by means of bolts nuts chek nuts and washers of galvanized iron or steel earth lead wire protected by and including 15 mm dia GI pipe medium grade pipe for protection and 20 mm dia GI pipe (medium grade) for watering and connected to control switch as directed including necessary earth work as in soft/loose soil, concrete pit in PCC (1:3:6) type c1, pre cast RCC 1:1:5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 100 mm CC both way and 2 No, lifting handle made of 12mm dia TMT bar and set in cement mortor (1:4), funnel wire nesh, char-coal or coke and salt in alternate layer, testing etc complete all as specifide in electrical plate No. 3 of SSR Pt-1 all as specified and directed. Note:- (i) If the desired earth resistance is not found within permissible limit, shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 Sqmm and 15mm dia GI pipe medium grade upto 7.5 m is included in the rate quoted for this item.
Earthing of machiner/equipment Installed at power house/substation(Pump & Motor), earthing complete with Copper earth plate electrode 60×60cm.× 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion .
Material and labour for earthing with galvanised steel earth plate electrided 600 X 600 X 6 mm thick buried in ground (earth pit not less than 2.25 mtr depth below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth lead wire 4.0 mm dia by means of bolts nuts chek nuts and washers of galvanized iron or steel earth lead wire protected by and including 15 mm dia GI pipe medium grade pipe for protection and 20 mm dia GI pipe (medium grade) for watering and connected to control switch as directed including necessary earth work as in soft/loose soil, concrete pit in PCC (1:3:6) type c1, pre cast RCC 1:1:5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 100 mm CC both way and 2 No, lifting handle made of 12mm dia TMT bar and set in cement mortor (1:4), funnel wire nesh, char-coal or coke and salt in alternate layer, testing etc complete all as specifide in electrical plate No. 3 of SSR Pt-1 all as specified and directed. Note:- (i) If the desired earth resistance is not found within permissible limit, shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 Sqmm and 15mm dia GI pipe medium grade upto 7.5 m is included in the rate quoted for this item.
Anti climbing device spikes type fabricated out of MS bars (round Sq and flat)including nuts,bolts, washeers and welding in two halves made toshape to suit the cross-section of the pole .
For Pump station No 1 (for 02 Nos of Pumps):- Supply installation, testing and commissioning of LT Panel board, indoor type full wired control panels (both operation manually & Auto) and shall be of suitable size made of 2 mm thick CRCA sheet powder coated with IP-54 conforming CPRI approved from with mounted accessories as per BOM annexute. Make: Siemens/ Schneider/ Powertech
For Pump station No 2 (for 02 Nos of Pumps):- Supply installation, testing and commissioning of LT Panel board, indoor type full wired control panels (both operation manually & Auto) and shall be of suitable size made of 2 mm thick CRCA sheet powder coated with IP-54 conforming CPRI approved from with mounted accessories as per BOM annexute. Make: Siemens/ Schneider/ Powertech
Supply installation , commissioning and testing of smart motor protection devices for motor/ pumps (01 no working and 01 No standby), VFD should have 22KW/30 HP- heavy duty rating according to pump rating works in both a synchronus motors. Make: Siemens/ Schneider/ Powertech.
Supply installation, commissioning and testing of Human machine interface (HMI) for local operation of motors/ pumps HMI should be 7" screen touch color TFT with minimum 01 ethernet port USB port and programming support. Make: Siements/ Schneider/ Powertech
Supply, installation, commissioning and testing of standalone PLC system in control Panel RTU/PLC have 2410's & capability to store date 24V/48V/110V DC operation, RTU/ PLC should be Modbus, Modbus TCPIP, DNP-3 protocol complaint with 2 TCPIP port
Supply, installation, commissioning and testing of Ultra sonic transmitter for measuring of water level. Make: E&H/P&F/MAX.
SCHEDULE 'A' PART VIII : DG SET
Supply, installation, testing and commissioning of silent diesel engine driven generating set 415 Volts, 3 phase 4 wire engine as per IS 10001/10002 and alternator as per IS 13364 complete CPCB norms with outdoor AMF panel with necessary foundation as per manufacturer recommendations. AVM pads control panel with necessary meters and sound proof canopy of capacity upto 62.5 KVA complete all as specified and directed for the following specifications :- (A) DIESEL ENGINE :- water cooled, 4 x cylinder (83 BHP) @ 1500 RPM , Engine shall be cooled by rail mounted, engine driver radiator of adequate capacity, with blower fan , fan guard, self regulated electronic governor and fan belts etc. The diesel engine shall be vertical, to run continuously at 1500 RPM confirming to IS 10002, BS-5514, standard with overload capacity of 10% for one hour in every 12 hours of operation. Diesel Engine shall be comply with latest CPCB Norms. (B) ALTERNATOR :- Alternator 62.5 KVA, suitable to deliver rated output at 1500 RPM, 415 Volt, 0.8 PF (LOG), 50HZ, 3 PH, in SPDP enclosure, self-excited, and self regulated electronic governer. The alternator shall conforms to IS-13364 and shall be suitable for tropical condition. Full load efficiency of the alternator offered should be above 90%, insulation and temperature rise also limited to class-H. Enclosure shall confrim to IP-23. Totally enclosed, steel construction control panel comprising of follwings :- (i) Main on/ off MCCB 3 phase 4 pole 415 Volt, 50Hz 100 Amp taring-01 Nos. (ii) Phase indicating lamps set of three-01 Nos. (iii) Instrument fuse-01 Set. (iv) Digital Display /indication of engine and alternator parameters as mentioned below :- (a) Lube Oil Pressure (b) Battery Voltage. (c) Engine RPM. (d) Fuel Level in the Tank. (e) Engine Running Hours Indication. (f) AC Current and Voltage. (g) AC Frequency (h) AC Power Metering. (j) Suitable CTS for displaying the electrical Parameters.
M/S SURAT SINGH AND SONS (BID ID -3158024)
M/S Chhavi Constructions Co (BID ID -3158130)
Sudhir Sharma Associates (BID ID -3156484)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .