Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.6 L+₹1.3 L (8.38%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹16.7 L+₹1.4 L (8.94%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹17.0 L+₹1.7 L (10.8%)Rejected-Finance SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹20.8 L+₹5.5 L (35.9%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
15 Jan 2024, 6:00 pmClosed
GE I R AND D Chandigarh
Garrison Engineer I R and D, DIHAR Base Lab, Ground Floor, Near 3 (BRD) AF Stn, Industrial Area, Ph-II, Ramdarbar, Chandigarh
REPAIR MAINTENANCE OF EXTERNAL WATER SUPPLY LINES VALVES, PUMP SETS AND WATER LEVEL CONTROLLER AT SECTOR 24, 37, 42, 28, 29, 30 AND OTHER EQPT AT CHANDIGARH
2023_MES_622628_2
GE I R AND D/CHD-76/2023-24
Open Tender
Civil Works
Item Rate
180 days
Chandigarh
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandigarh
₹38,000
Yes
12 Mar 2024
27 Dec 2023
17 Jan 2024
27 Dec 2023
15 Jan 2024
2 Jan 2024
Amount
Disconnecting the 3 phase electric motor of capacity 7.5 HP from the fire fighting pump set, taking down from the foundation , removal of defective winding from the stator , cleaning the slots & core, egressing with suitable solvent using polyester enamelled copper wire of suitable gauge & class F insulating materials, sleeves , cotton tapes etc. The winding is dried in oven & it is impregnated with insulating varnish Of Dr. Beck & Co, & backed in a oven as specified by the manufacturer. After backing a coat of epoxy resin is applied on the winding to protect it from harmful effect of moisture in egress & chemical atmosphere. The motor shall be assembled with fresh lubrication to the bearing & test run to be taken at original position , making all electrical connections. Dismantalling the pump, check the alignment, impelers and bearing etc. Overhauling the pump by greasing, oiling complete. Testing for proper working complete all as specified and directed. Note:- Copper winding wire and bearing of suitable size etc. shall be measured and paid separately under respctive Items.
All as per serial item No 1.00 above but capacity 10 HP
All as per serial item No 1.00 above but capacity 5 HP non clog submersible
Disconnecting the 3 phase electric motor of capacity 20 HP from the fire fighting pump set, taking down from the foundation , remove deposits of dust, oil and dirt in the fan cover to maintain good ventilation and allow proper cooling of the motor, remove and nenew grease in ball bearing . The motor shall be assembled with fresh lubrication to the bearing & test run to be taken at original position , making all electrical connections. Dismantalling the pump, check the alignment, impellers and bearing etc. Overhauling the pump by greasing, oiling complete. Testing for proper working complete all as specified and as directed.
All as per serial item No 2.00 above but capacity 65 BHP
All as per serial item No 2.00 above but capacity 10 HP
All as per serial item No 2.00 above but capacity 7.5 HP
Supply only super enamelled copper winding wire complete all as specified and directed
Supply only PVC insulated water proof copper conductor winding wire complete all as specified and directed
Supply and replacing of ball bearing No 6206/6208/6306/6307 complete all as specified and directed
Supply and replacing of ball bearing No 6308/6309/6310 complete all as spcified and directed.
Material and labour for repair to Submersible pump set motor of capacity 5 to 7.5 HP by dismantling of submersible motor 3 phase, 440 Volts cutting and removing the burnt winding wire, cleaning of slots and rewinding with super quality PVC insulated water proof copper conductor winding wire and machining as per original dia complete and replacement of thrust plate, thrust bearing, rotor straightenting, sealing kit, balancing of rotor.and reassembling complete all as specified and as directed (Thrust plate, thrust bearing, rotor straightenting, sealing kit, balancing of rotor and reassembling shall be unit rate deemed to include cost of the same by the contractor). Note:- PVC insulated water proof copper conductor Winding shall be measured and paid separately.
Material and labour for replacement of unserviceable submersible cable 3 core 1100 Volt flat stranded copper conductor of size 10 Sqmm, ,complete all as spcified and directed.
Material and labour for cleaning of RCC under ground water sump of capacity approx 100000 Ltrs in technical area by removal of sludge, scrapping silt mud and foreign material etc with wire brushes on the walls and floor of tank and washing and flushing the surfaces with bleaching powder and taking out the same manually from the compartments and removing the same to a distance not exc 50m and depositing where directed by Engineer -In - Charge and applying two coats of first grade synthetic enamelled paint (Internally ) to the tank, writing date of cleaning with white paint on black patch 45cm X45cm on external surface of tank in technical area complete all as specified and as directed. Note:- The cleaning of RCC under ground water tank will be carried out in every six months.
Material and labour for cleaning of RCC under ground water sump of capacity approx upto 25000 Ltrs in technical area by removal of sludge, scrapping silt mud and foreign material etc with wire brushes on the walls and floor of tank and washing and flushing the surfaces with bleaching powder and taking out the same manually from the compartments and removing the same to a distance not exc 50m and depositing where directed by Engineer -In - Charge and applying two coats of first grade synthetic enamelled paint (Internally ) to the tank, writing date of cleaning with white paint on black patch 45cm X45cm on external surface of tank in technical area complete all as specified and as directed. Note:- The cleaning of RCC under ground water tank will be carried out in every six months.
Disconnecting the electric supply and out let connections and taking out of submersible pump set 7.5 to 15 HP capacity with column pipes and submersible cable etc from U/G sump by means of mechanical T&P and keeping aside and repairing the same by supply and replacing the following spare parts complete all as spcified and directed.
Supply only GM bush.
Supply only Non return valve GM.
Supply only Impeller key.
Supply only Bearing Sleeve.
Supply only Impeller GM.
Supply only Shaft S/S.
Supply only Suction strainer.
Supply and replacing rotational moulded polythelene water storage tank 1000 ltr capacity 5 layered cyliderical vertical with closed top ISI marked hoisted and fixed in position as specified in SSR part-I complete including tank nipples of 20/25 mm dia for making inlet and outlet connections complete all as spcified and directed.
Supply and Fixing water flow meter of 15 mm size brass with suitable fixing material at both ends i.e union/elbow/tee etc incl testing of meter as approved of UT Chandigarh . Note :-Old water meter shall be deposited in MES store yard as the property of deptt.
Dismantling existing cement mortar bedding( holding block of motor ) and precast concrete articles complete and remove the wastage material 50 mtr away from site complete all as spcified and directed.
Material and labour for cement concrete (1:2:4), type B-1, using 20mm graded mechanically crushed stone aggregate as in , bed block benching, kerbs, mud stop, square or chamferred on edges including necessary form work/moulds complete all as specified and directed.
Supply and instalation in replacement monoblock type water pumping set and discharge size 25mm and discharge pressure of 1600 to 600 LPH at 6/30 Mtr head self priming type 1.0 HP capacity single phase 220 volts including disconnecing and re-connect electric and water connection complete all as spcified and directed.
Supply, installation, testing, connecting of mono block centrifugal pump set at a head of 27 mtr, 2900 RPM , 80x 65 mm coupled with squirrel cage induction motor 415 volt 3 phase not less than 7.5 HP/5.5 KW, 50 Hz , insulation type "B" , duty type S-1 complete all as specified and directed.
Material and labour in replacement of existing cover mild steel sheet 3.15 mm thick of size 0.61x0.46x.47mtr with angle iron frame of size 40 x 40 x 5 mm thick with suitable nuts and bolts to fix on platform of monoblock pump duly painted with two coats of smoke grey paint over a coat of red oxide primer complete all as spcified and directed.
Supply and fixing for cast iron sluice valve flanged and drilled with stainless steel spindle, iron wheel ISI marked with nuts, bolts & washers and gasket heavy duty PN 1.6 of following sizes tested with high pressure conforming to IS - 14846,of 100 mm dia.
Supply and fixing for cast iron sluice valve flanged and drilled with stainless steel spindle, iron wheel ISI marked with nuts, bolts & washers and gasket heavy duty PN 1.6 of following sizes tested with high pressure conforming to IS - 14846,of 80 mm dia.
Supply and fixing for in replacement of rubber gasket suitable for 80mm/100 dia sluice valve stuffing box.
Supply and fixing for inreplacement of gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 15 mm dia, complete all as spcified and directed.
All as per serial item no 28.00 above but size 20 mm dia,
All as per serial item no 28.00 above but size 25 mm dia,
All as per serial item no 28.00 above but size 40 mm dia,
All as per serial item no 28.00 above but size 50 mm dia,
Material labour for complete detect & repair of leakage of pipe line from surface/ground/floor/floor/roof /wall of size 15/20/25/40/50 mm dia using with suitable material e.g elbow/Tee/union /socket of any size as directed by Engr in-charge . Note : Exavation and demoliton of concrete will be measure and paid separetely .
Supply and fixing for in replacement of water tank top cover suitable for 500 litre water tank
Dismantling existing concrete of any description ie floor/tiles and in any position and remove the wastage material 50 mtr away from site as specfiied and as directed.
Material and labour for cement concrete in type B1 1:2:4 (20 mm graded aggregate) mechanically crushed stone aggregate as in bed, block, benching kerbs, mud stop, square or chamferred on edges including necessary form work/moulds complete all as specified and directed.
Taking up or down / Cutting steel tubing and connections , including cleaning for refixing or removal to store of size Bore of pipe 15 mm.
All as per serial item no 34.00 above but size Bore of pipe 20mm.
All as per serial item no 34.00 above but size Bore of pipe 25mm.
All as per serial item no 34.00 above but size Bore of pipe 40 mm.
Supply and fixing in repairs galvanised tube medium grade, with all fitting as required at site like TEE/Elbow/Bend/socket etc and fixed complete to walls and ceilings or laid in trenches/ floors/ tiles of size Bore of pipe 15 mm.
All as per serial item no 35.00 above but size Bore of pipe 20mm.
All as per serial item no 35.00 above but size Bore of pipe 25mm.
All as per serial item no 35.00 above but size Bore of pipe 40 mm.
Supply and fixing for Battery 12V, 150 AH with Electro plates including battery lead positive & negative battery terminal complete duly charged .
Supply and fixing in replacement 15 mm bib tabs standard PTMT any colour high pressure screwed for iron pipe minimum weight 15 mm - 90 Grams fix complete.
Material and labour for Ball brass valves,high pressure,with polythene float and flynut float and flynut complete,screwed for iron pipe or brass ferrule and fixed
Material and labour for Earthing complete with galvanized steel earth plate electrodes 60x60x6 mm thick buried directly in ground (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanized iron earthing strip 25mm x 4mm thick by means of bolt nuts check nuts and washers of galvnised iron or steel all as specified &shown in electrical plate No.3 of MES SSR part-I connected as specified and directed, and testing on completion including provision of protection pipe 40mm dia GI light grade pipe and watering pipe 20 mm bore medium grade including all excavation & earth work in any strata incl PCC for pit in (1:3:6) type C-1 with RCC cover in PCC(1:2:4) including chrcoal , salt, funnel, all as specified. Note:- strip shall not be protected with pipe. Earth strip shall be meassured seperately
Supply and fixing for inreplacement of CI foot valve flanged 50 mm dia heavy duty with fixing arrangement and testing on completion complete all as specified and directed.
Supply and fixing for inreplacement of CI foot valve flanged 80 mm dia heavy duty with fixing arrangement and testing on completion complete all as specified and directed.
Supply and fixing in replacement of heating element 1500 Watt suitable for 25 litre capacity geyser including testing complete all as specified and directed.
Supply and fixing in replacement of auto cutt - off thermostat suitable for 25 litre capacity geyser including testing complete all as specified and directed.
Supply and fixing in replacement of DOL motor starter stainless steel suitable for 5 HP 3 phase 415 V submersible electric motor including connection, testing complete all as specified and directed.
Supply and fixing for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
Material and labour for cleaning of PVC water tank of capacity 500 Ltrs in Md accn area by removal of sludge, scrapping silt mud and foreign material etc with soft brushes on the walls and floor of tank and washing and flushing the surfaces with bleaching powder and taking out the same manually from the bottom surface and removing the same to a distance not exc 50m and depositing where directed by Engineer -In - Charge
Supply and fixing and testing in replacement of fully automatic water level indicator single phase on water tank upto 10 - 20 meter height with anti corrosion sensor, contact capacity 2 HP , start, stop, auto manual switch , tank level indication, pump on indication and connections with copper conductor copper wire 1.5 sq mm of suitable length complete all as specified and directed.
SANJEEV ENTERPRISES
M/s Shiksha Enterprises
M/s Friends Engineering Works
GOODWILL ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .