Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | ₹2.3 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹2.3 Cr+₹27,659 (0.12%)Rejected-AOC 6TH CROSS STREET KAMARAJ NAGAR PALAYAMKOTTAI | PALAYAMKOTTAI | TIRUNELVELI | TAMIL NADU | 627002 | ₹2.3 Cr+₹27,659 (0.12%) | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹2.4 Cr+₹4.4 L (1.86%)Rejected-AOC 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | ₹2.4 Cr+₹4.4 L (1.86%) | L3 | Rejected-AOC NOT BEING LOWEST |
| 4 | L4₹2.4 Cr+₹5.3 L (2.25%)Rejected-AOC | ₹2.4 Cr+₹5.3 L (2.25%) | L4 | Rejected-AOC NOT BEING LOWEST |
| 5 | L5₹2.4 Cr+₹7.3 L (3.13%)Rejected-AOC | ₹2.4 Cr+₹7.3 L (3.13%) | L5 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹2.1 Cr
EMD Value
₹2.8 L
Closing Date
15 Aug 2022, 6:00 pmClosed
CHIEF ENGINEER CHENNAI ZONE
CHIEF ENGINNER CHENNAI ZONE ISLAND GROUNDS CHENNAI 600009
SPECIAL REPAIRS TO BLDG T-26 FAD FIVE BASE OF 515 ARMY BASE WORK SHOP AT BANGALORE
2022_MES_523385_2
88543/E8
Open Tender
Construction Works
Item Rate
365 days
BANGALORE
As per Appendix A of NIT
8 documents required · 8 mandatory
₹2,000
Garrison Engineer (South) Bangalore
₹2.8 L
Yes
4 Sept 2022
18 Jul 2022
17 Aug 2022
18 Jul 2022
15 Aug 2022
2 Aug 2022
19 Jul 2022 - 28 Jul 2022
Amount
B/R ITEMS
Demolition of brick work or precast cement concrete block walling or stone masonry built in cement mortar including all quions, arches, pillars etc., but excluding ashlar facing etc., complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thick below or above GL including removal of debris to outside MD land.etc., complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and paving exceeding 15cm thick below or above GL including removal of debris to outside MD land.etc., complete all as specified and as directed.
Dismantling wrought iron or mild steel works of any description not otherwise provided for.complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semicorrugated including ridge.) sheets in roof coverings complete all as specified and as directed.
Dismantling of plain, corrugated, semicorrugated steel sheets of any gauge, thickness including Nainital or similar pattern in roof coverings etc., complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., and cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
Material and Labour for precast cement concrete block masonry with solid blocks exceeding 10cm in width, of grade C4 all as per IS 2185 , having minimum average compressive strength 4 N/sqmm at 28 days and density not less than 1800 kg/cum, set in CM 1:6 all as specified and as directed
Material and labour for providing precast cement concrete, 1:2:4, type B1, using 20mm graded stone aggregate and set in CM 1:4 as in cooking platform, landings, manhole cover slabs, chullah hoods, Chajjas, water troughs, shelves, and similar articles with plain faces complete all as specified and as directed. Note: Reinforcement bars shall be measured and paid under relevent item.
Material and labour for reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in foundation, incl rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs under reamed piles and mass concrete.complete all as specified and as directed.
Taking down door / window chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area not exceeding 1.5 Sqm each complete all as specified and as directed.
Material and labour for Mild steel framed work such as gates and grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290, Gde E-165 complete all as specified and as directed.
Supply and fixing of mild steel bolts of dia of neck exc 20 mm but n. exc 25 mm, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 30 cm long including fabrication and repair all as directed by Engineer -in-Charge
Material and labour for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and as directed.
Supply, fabricate and erection / fixing of Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc.complete conforming to Fe-410-W, Gde E-250, Quality A all as specified and as directed.
Supply and fix rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee, angle channel or flat sections) incl distance pieces, cleats etc., Conforming to Fe-410-W (Gde-E-250) quality-A. all as specified and as directed.
Supply and Fixing of steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, with glazing bars dovetailed or welded complete all as specified and as directed.
Supply and fix 2.0mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and as directed. Note: The corrugation of the sheet to be same as item No.36.00 of BOQ
Supply and Fixing of 1.8 mm thick plain, galvanised, zinc coating mild steel plain sheeting in ridge, hips, valley gutters, drip and straight flashing (length and grith as fixed) with grade of zinc coating 275.complete all as specified and as directed.
Supply and fix Multi rib TM profile Pre-painted galvalume aluminum zinc coating Galvanised iron based plain steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, cut as per site requirement fixed with self drilling/self tapping screw with EPDM seal etc., complete all as specified by manufacturer specification complete all as specified and as directed.
Material and labour for 100 mm thick plain cement concrete M-15 Design Mix, as in floor, floor to be finished by Vaccum Dewatering Flooring (VDF) method to received EPU complete all as specified and as directed by Engr-in-Charge.
Material and labour for Plain 75 mm thick Cement Concrete 1:4:8, type D2,(using 40mm graded stone aggregate) as in sub base of flooring complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.including brushing neat cement slurry with 3.0kg of cement per Sq. metre complete all as specified and as directed.
Taking down cement plaster of any description on brick work or stone walls / concrete surfaces / ceiling plaster etc., including raking out of joint, hacking for key scrubbing down with water and removing debris to outside MD land etc., complete all as specified and as directed.
Supply and Fixing of rough cast wired glass, 6.4 mm thick and glazing with oil putty in square area exc 0.75 sqm but n.exc 1.0 sqm complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pin, spring/clips and providing and fixing new ones. complete all as specified and as directed.
Material and labour for preparation of old painted wooden and wood based surfaces of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Material and labour for preparation of new or previously untreated steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enemel paint over a coat of red oxide. primer complete all as specified and as directed.
Material and labour for preparation of old painted steel surfaces of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Supply and fixing of UPVC (SWR) pipes 110mm bore, single socketed in any length with rubber ring joints fixed to walls or under floors including taking down old pipes etc., complete all as specified and as directed .
Supply and fix in 110mm bore UPVC (SWR) bend any radius with access door complete all as specified and as directed.
Supply and fix in 110mm bore UPVC (SWR) reducers any radius with access door complete all as specified and as directed.
Supply and fixing of forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound A Grade of epoxy based material and all as per manufactrurer instruction and Appoxy filled material all as specified and directed by Engr-in-Charge
Supply and fixing of forming Construction joint 30mm deep x 10mm wide filled with sealing compound A Grade of epoxy based material and all as per manufactrurer instruction and all as specified and directed by Engr-in-Charge
Material and labour for Mild steel framed work such as gates and grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290, Gde E-165 complete all as specified and as directed.
Supply and Fixing of 0.50 mm thick aluminium alloy colour coated roofing sheets of alloy IS designation 31500, temper H*8 conforming to IS 737 and dimension as per IS Code 2676 with characteristics of good formability and corrosion resistance and troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width 1092 mm, cover width 1000mm at all heights, levels and locations. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/ tapping stainless steel screws M6, 60 mm long with 3 mm EPDM seal washer inclusive scaffolding, Tools and plants and sundries complete all as specified and as directed.
Material and labour for 75 mm thick PCC 1:3:6, type C1 using 20mm graded stone aggregate in plinth protection as specified and all as directed.
Material and labour for Rendering 15 mm thick in Cement Mortar 1:4, mixed with water proofing compound as per manufacturers' instructions on stone mason surfaces, finished even and fair etc., complete all as specified and as directed. Note: Water proofing compound shall be measured and paid separately under relevant items.
Supply only Integral Water Proofing Compound conforming to IS:2645-2003 complete all as specified and as directed.
Material and labour for Rendering 15mm thick in Cement Mortar 1:6 on stone masonry wall surfaces or surface other than fair face of brick-work inculding finishing the wall surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for complete removal of existing treatment of old treated surfaces of walls including washing, rubbing and preparation of old surface on walls, ceiling, chajja etc. and applying two coats of cement Base over a coat of primer as per manufactures instructions with all necessary scafolding etc complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over including one coat of primer over 2 mm thick layer of wall care putty complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Material and labour for complete removal of existing treatment and applying two coat of oil bound distember over one coat of primer and over 2 mm thick layer of wall care putty on plastered surfaces complete all as specified and as directed..
Supply and Fixing of sheet glass 4mm thick ordinary quality and glazing with oil putty / wooden beads as directed in squares not exceeding 0.50 Sqm in each pane including Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones etc., complete all as specified and as directed.
Demolition of cement concrete (reinforced) in manhole cover not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
Supply and fixing of 600 mm dia wind driven Roof Ventilator with high grade alluminium alloy Industrial type of thickness not less than 0.5mm with Stainless steel -304 bearing and necessary fitting and fixtures all as specified and as directed by Engr-in-Charge.
Taking down steel door shutter exc 2 Sqm but not exc 5 Sqm and refixed the door in same opening with necessary floor support assembly heavy duty pintel to the door 01 No in each Shutter including demolition of foundation and recast the same of size 400x400x400mm of PCC 1:2:4 and repair to pintel hinges 02 No in each shutter and aldrop bolt and necessary minor repair ie oiling, easing to door all as directed by Engineer-in-Charge.
Note for Item No.48.00 1. The door shutter shall operate freely after repair and refixing door shutter. 2. The door shutter shall be taken down and refixing shall be done with necessary machanical equiptment 3. Fixing of sheet and replacement of any rusted/damage steel angle/tee/flat shall be measured & paid under relavent items separately.
Material and Labour for 150 mm width Gangway yellow line with epoxy material as per item No.50.00 (d) marking in Factory floors and fixing of masking tapes on both sides of the line and cleaning the surface using solvents, and removing the masking tape after marking of neat finish complete all as directed.
Material and Labour for Epoxy Polyeurethane Coating (EPU) all as specified and as directed with the following:- Ref Details Sl No: 50.01(a) to (d) to 50.03
50.00 Condt... (a) Preparation of the dry concrete surface by using proper scarification equipment to remove all loose material, contaminations and laitance to provide a sound, gripping surface, clean the entire floor area to a dry state inspecting the surface of cracks if any have to be sealed with epoxy repairing mortar by cutting 'V' groove and to correct the floor undulation, installation of 3mm thick epoxy self level mortar screed to be provided. (b) Supply and application of moisture insensitive solvent free epoxy bonding primer over the prepared surface (Floor/Coving) in a thin continues film and spread the primer into the surface using a shift bush or roller. Applying the second priming coat on identified light coloured dry patches over first coat to achive uniform thickness of 200 micron of priming coat in complete areas. The approximate coverage rate shall be 5.5-6.5 sqm/litre as per manufacture's instruction shall be followed . Installation of the coving with powder coated auluminum extruded section of minimum 1mm thick and radius 60mm all around placing of earthing/ground tapes of copper strip of size 25 x 0.5 mm and grid size 2.0m x 2.0m.shall be provided.
50.00 Condt... (c) Supply and application of base layer pigmented of self smoothing self levelling epoxy underlay spread evenly to maintain 3.0 mm thickness using a serrated trowel and with spike roller, rolled over the levelled underlay to remove any entrapped air all as per manufacturer instructions. Apply epoxy based putty to fill the substrata of below holes/voids and surface levelling by using approximate products to be provided. Physical properties : (As per IS 9197-1979) (d) Supply and application of Shalifloor SLAS 3PU with protective coating Shalifloor 2PUTC and application of ShaliPoxy thinner or equivalent as approved heavy duty Epoxy polyeurethane (EPU) based flow applied self leveling topping system of thickness 2.0 mm to achive smooth and glossy finish as per manufacturer instructions and as sepcified below. -
50.00 Condt... Physical properties :Compressive strength (Min) -28 Days - 45 N/mm2 (ASTM C 579) Flexural Strength (Min) - 28 days -15 N/mm2 (ASTM C 580 Tensile Strength (Min) - 28 Days - 6.5 N/mm2 (ASTM C 307) Abrasion Resistance - 0.1-0.15 mg/cycle-loss of weight (ASTM D 4060 with CS 17 steel of 1000g weight) Shore D Hardness - 70-80 (ASTM D2240) Tensile Adhesion Strength (Min) < 1.5 N/mm2 (failure in concrete ) (ISO 4624)
E/M ITEMS
Taking down carefully existing Unserviceable Aluminium batten/surface conduit/casing caping point wiring (light/exhaust fan/socket/call bell/Power point) complete including fittings and fixtures such as switches, ceiling roses, shades, brackets, sockets, holders, light fittings, call bells and removing the materials to store for keeping in safe custody for reuse at site or for taking credit including making good the disturbed surfaces of walls/floors/ceilings etc. complete all as specified and as directed.
Taking down Unserviceable main switches , DB's /change over switch along with teak wood boards etc and making good the distrubed surfaces of wall /floors to match the existing surfaces complete all as specified and as directed.
Material and labour for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including non metallic PVC rigid conduit medium grade of size 19mm dia with all accessories fixed on wall / ceiling including continous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including provn of fabricated branded pressed steel terminal box of suitable sizes & 1.6 mm thick duly painted inner & outside by anti-corrosive paint, for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover with brass screw, cup washer complete all as specified and directed for the following:- Note : (i) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. (ii) The cost of cutting chases in brick/stone masonry walls and making good the disturbed surfaces is deemed to be included in the quoted rate.
(b) One three pin switch socket 5/6 Amps outlet on same board.
(c) One three pin switch socket 5/6 Amps outlet on independent board.
Material and labour for point wiring complete all as specified with 1100 Volts grade 4 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including non metallic PVC rigid conduit medium grade of size 19mm dia with all accessories fixed on wall / ceiling including continous earth wire 4 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including provn of fabricated branded pressed steel terminal box of suitable sizes & 1.6 mm thick duly painted inner & outside by anti-corrosive paint, for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover with brass screw, cup washer complete all as specified and directed Note:Note : (i) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. (ii) The cost of cutting chases in brick/stone masonry walls and making good the disturbed surfaces is deemed to be included in the quoted rate.
Supply and fix switch piano, flush type, single pole, one way, 5/6 Amps, 230 volts, ISI marked complete all as specified and as directed.
Supply and fix socket outlet 5 pin 6 Amps flush type multipurpose suitable for 3 pin/ 2 pin plug complete all as specified and as directed
Supply and fixing of switch piano15 Amp 230 Volts, flush button single pole one way, ISI marked complete all as specified and as directed.
Supply and fix socket outlet 2 in 1, 3 pin 6/16 Amps and 3 pin flush type 230 volts, ISI marked complete all as specified and as directed.
Supply and fix electronic fan regulator stepped flush type 230 Volts suitable for 1200mm/ 1400mm sweep ceiling fans etc., complete all as specified and as directed.
Supply and fix ceiling rose, surface mount type, PVC/ Polycarbonate, isolated body with face bakelite 65 x 50mm 2/3 terminals complete all as specified and as directed.
Supply and fixing surface 20 Watts LED (4'x1) wall mounted batten with integrated LED channel engineering plastic batten with white acrylic cover system luminarie with all accessories cat part No BCLSB20WH or Bajaj techno-commercially equivalent of other specified makes including connecting up with three core flexible copper conductor cable of sustainable size from ceiling rose and all as specifiedand as directed.
Supply and fixing 36Watts, LED recessed 600 mm x 600 mm luminrie 230 V AC with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED Lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete White powder coated CRCA housing with seamless front frame with flat non-yellowish diffuser of capacity including connecting up with three core flexible copper conductor cable of sustainable size from ceiling rose and all as specifiedand as directed. Make: Bajaj cat No -BZRSQL 36W GZi WH or equivalant of Wipro and CG. Notes for items No. 61 to 62: The new fittings shall bear the CA No. and Year written by Black synthetic enamel paint using stencils or by permanent marker pen and the unit quoted shall be deemed to include the cost of writing these details.
Supply and fixing Rigid non metalic PVC conduit exclusive of boxes (junction/Terminal) but inclusive of all tees , bends, elbows, reduces , bell mouth tub ends and fixing accessories such as couplers , lock nuts saddles pipe hooks etc of dia 25mm
Supply and fixing PVC junction boxes 1 to 4 Way of size 25mm dia complete all as specified and as directed.
Taking down old exsiting wall mounted Air circulator fan from site and harder over to deposited to MES GE E/M store yard.complete all as specified and as directed.
Supply and fixing ceiling fan complete with blades, down rods of required length and accessories 230 V 1200mm sweep, Min air delivery 210 CFM with service value 6.00 BEE five star rated with brush less direct current motor (BLDC) and including provision of suitable hook for hanging of ceiling fan and connecting up using copper conductor cable of size 3 core 0.5 sqmm to PVC terminal of ceiling fan testing complete all as specified and directed by Engr-in -Charge.
Supply ,installing, testing and commissioning of Air circulator 600mm wall moutning type single phase 230 Volts silent type including connecting up using copper conductor cable of size 3 core 0.5 sqmm to PVC terminal of fan testing complete all as specified and directed by Engr-in -Charge.
Material and labour for Sub main wiring with Three runs of 2.50 Sqmm (1 Phase, 1 Neutral and 1 Earth) single core, multistranded, FRLSH PVC insulated unsheathed cable 1100 volts grade with copper conductor conforming to IS:694 with ISI marking, drawn through existing non metallic PVC grey conduit medium grade with conduit fittings and all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of the building as ordered and testing on completion including taking down and removing the existing sub main wiring and making good the disturbed surface to match with the existing surface etc., complete all as specified and as directed. Note: (i) Three runs of 2.50 sqmm multistranded cable shall be considered as one unit length. (ii) Colour code for submain wiring shall be Red, Yellow and Blue for Phase, Black for neutral and Green for earth.
Material and labour for Sub main wiring with Three runs of 4.00 Sqmm (1 Phase, 1 Neutral and 1 Earth) single core, multistranded, FRLSH PVC insulated unsheathed cable 1100 volts grade with copper conductor conforming to IS:694 with ISI marking, drawn through existing non metallic PVC grey conduit medium grade with conduit fittings and all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of the building as ordered and testing on completion including taking down and removing the existing sub main wiring and making good the disturbed surface to match with the existing surface etc., complete all as specified and as directed. Note: (i) Three runs of 4.0 sqmm multistranded cable shall be considered as one unit length. (ii) Colour code for submain wiring shall be Red, Yellow and Blue for Phase, Black for neutral and Green for earth.
Material and labour for Sub main wiring with Three runs of 6.00 Sqmm (1 Phase, 1 Neutral and 1 Earth) single core, multistranded, FRLSH PVC insulated unsheathed cable 1100 volts grade with copper conductor conforming to IS:694 with ISI marking, drawn through existing non metallic PVC grey conduit medium grade with conduit fittings and all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of the building as ordered and testing on completion including taking down and removing the existing sub main wiring and making good the disturbed surface to match with the existing surface etc., complete all as specified and as directed. Note: (i) Three runs of 6.0sqmm multistranded cable shall be considered as one unit length. (ii) Colour code for submain wiring shall be Red, Yellow and Blue for Phase, Black for neutral and Green for earth.
Notes for items No. 68 to 69 and 70: The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
Supply and Fix in replacement factory made, vertical distribution board ( MCCB DB), IP 43-IK 09, TPN, 4 way, 415 Volts, double door, semi flush type made out of 1.2mm thick CRCA sheet metal, duly powder coated and conforming to IS 8623 fitted with suitable copper bus bar, neutral links, blanking plate etc., all as per Cat No.DHDLVDRWGOFO04 of Havells or DPX3160MCCB DBs 5077 25 of Legrand or techno-commercially equivalent of other specified makes fixed on wall including connecting, testing etc., complete all as specified and as directed. Note:Cost of MCCBs and MCBs shall be measured and paid under relevant item.
Supply and fix MCCB, 4 pole,100 Amp, 415 volt 16 KA breaking capacity (Ics =100% of Icu) with fixed thermal & fixed magnetic setting complete all as specified and as directed by Engineer-in-Charge.
Supply and Fix in replacement factory made, vertical distribution board ( MCCB DB), IP 43-IK 09, TPN, 12 way,240Volts, double door, single pole made out of 1.2mm thick CRCA sheet metal, duly powder coated and conforming to IS 8623 fitted with suitable copper bus bar, neutral links, blanking plate etc., all as per Cat No.DHDNSHCDOW12 of Havells or techno-commercially equivalent of other specified makes fixed on wall including connecting, testing etc., complete all as specified and as directed. Note:Cost of MCCBs and MCBs shall be measured and paid under relevant item.
Supply and fixing MCB SPN 40 Amps single pole 6 to 40 Amps, 240 volts of rupturing capacity 10 KA 'C' curve type for fixing in MCB DB complete all as specified
Supply and fixing MCB SP 6 to 32 Amps single pole 240 volts of rupturing capacity 10 KA 'C' curve type for fixing in MCB DB complete all as specified
Material and Labour for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less' than 1.5meters below normal ground level, earth plate connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR-2009 (part I Specifications) connected to earth test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil and adequate quantity of common salt & charcoal for alternate layer around the earth plate, including PCC (1:2:4) pit and 10mm thick C.I. cover with arrangement of hinge to 40x40x6mm C.I. angle iron frame, including 20mm dia G.I. pipe for watering purpose with the arrangement of funel and wire mess, including GI pipe of 15 dia for earth lead protection complete all as specified and as directed.
Supply and lay GI tube 20mm bore, light grade, ISI marked with all fittings, complete, fixed to walls, pole ceiling or laid in trenches/ floor for cable protection at road crossing / on poles etc., complete all as specified and as directed.
Supply and lay in trenches/drawn through pipes or in road crossings/ paths/drains/ducts/ floors/along poles/ equipments etc., of LT cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts earthed grade confirming to IS-7098 (Part-2) 2011 of cross sectional area 16 Sqmm x 4 core including connecting up using suitable size aluminium lugs testing and commissioning complete all as specified and as directed.
Supply, fabricate and installation of GI pipe bracket made out of light grade GI tubing of 32mm bore, 1.20metre length bent to shape by hot forgoing after filling of sand and fixed on pole (or) wall with 2 Pairs of MS clamps made out 50 x 6mm Flat Iron of required shape including bolts, nuts and washers suitable for steel tubular pole and painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete including taking down unserviceable one all as specified and etc., complete all as specified and as directed.
Supply and fix 60 watts LED security light fittings aesthetically designed roadway luminaire with excellent thermal management complete IP 66 including connecting up with three core flexible copper conductor cable of sustainable size from ceiling rose and all as specifiedand as directed dismatling unserviceable one cat part No ENXT P 54L WH PO PC SD 45WATT Bajaj or techno-commercially equivalent of other makes specified in PS all as directed by GE.
M/S POTHIRAJ AND CO
K. VENKATESH NAIDU
D NAGI REDDY
ASSOCIATED ENGINEERS
Vinayaka Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .