Executive Engineer
PWD Electrical Division Medical College Jaipur
MGPS work in ICU (Room-202,203) at Trauma Centre SMS Hospital,Jaipur
2026_CEPWD_526345_4
EE_PWD_Medical_NIT_46_2025_26
Open Tender
Electrical Works
60 days
Trauma Centre SMS Hospital
Please refer tender documents
2 documents required · 2 mandatory
₹500
Through Egras Challan in Office ID 28560
₹23,460
Yes
In the Chamber of Executive Engineer
22 Jan 2026
9 Jan 2026
21 Jan 2026
9 Jan 2026
20 Jan 2026
9 Jan 2026
15 Jan 2026
SITC of MGPS of medically grade as per BSEN-13348 with third party certification from Lloyds/TUV degreased (ie free from oil, grease and partivulate matters) seamless copper pipe confirming to ASTM B88 and all copper joining done by brazing with AWSA5.8, classification BCuP-5 or BS 1845 following procedure in accordance with ASTM B828 after purging with nitrogen. All pipe cutting shall be carried out with a radial pipecutter and copper pipe fitting's shal comply with B4 alloy designation. Adequate support shall be provided while laying pipeline testing shall be done at 17 bar and after testing pipe shall be painted with two coat of enamel paint as per colour codification as per ISO 7396-Part-1 2016.Third party Test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with P.W.D. Electrical B.S.R. 2022.
SITC of non lubricated ball type Nickel Coated Isolation Valve with adapter & PTFE Seat having quarter turn / Butterfly handle opening of following sizes suitable for flow capacity of required LPM as per the size of valve at 4.7 bar with maximum allowable pressure of 30 bar and suitable for working temperature ranging - 20°C to 130°C. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with P.W.D. Electrical B.S.R. 2022.
For 12 MM OD pipe
For 15 MM OD pipe
For 22 MM OD pipe
For 28 MM OD pipe
SITC of Gas outlet points Oxy, N2O, (AR-4), (AR-7) and Vaccum (8.7 psig) for dispensing medical gases (oxygen/air/Vaccum) at point of use confirming to BSEN ISO 9170-1:2008. The gas outlet are quick connect type It should have color coding for different gas source and should accept only respective adapters as required. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. The Product should be CE Certified / CE Marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with P.W.D. Electrical B.S.R. 2022.
SITC of BPC (back pressure compensated) flow meter with humidifer made of nickel plated body , double jacketed with flow gradations CE Marked on it . Desired flow will be setteled through rotary knob . Flow range should be between 0 to 15 lpm & work should be executed as per direction of engineer in charge .Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. The Product should be CE Certified / CE Marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with P.W.D. Electrical B.S.R. 2022.
SITC of Ward suction unit (Suction Controller and Collection Jar - 600 ml capacity) with posibility to configure required capacity collection Jar and should meets the requirements as per BSEN ISO 10079-3:2009. The unit must designed to operate with the vaccum line of MGPS. The collection Jar must accumpained with Vaccum regulator suitable for 0-14.7 psig with flow rate 0-55 Lmp (min) for operating temperature - 18°C to 50°C with ON/OFF facility. The collection Jar should be transparent, made of high quality polycarbonate that can be autoclaved at 121°C for 20 minutes for reuse and provided with auto stop to avoid over spill and contamination of the suction source when the jar collection reached optimized level. The complete unit supplied with filter to protect the source and pipe line from bacterial contamination. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. The Product should be CE Certified / CE Marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with P.W.D. Electrical B.S.R. 2022.
SITC of Valve box made of CRCA sheet duly powder coated with transparent window which is installed in the MGPS for oxygen and vaccum line and should comply with BSEN ISO5211:2001 complete with ball type valves and gauges as required for oxygen compressed air and vaccum line. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. The Product should be CE Certified / CE Marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with P.W.D. Electrical B.S.R. 2022.
Three Gas Service
SITC of microprocessor based auto alarm system (digital type) suitable for medical gas service provided with audible and visual alarm for MGPS Zoning it should monitors the current status of oxygen/ compressed air pressure in distrubuton pipeline of central medical supply system and trigger the alarm to alert. The system should comply BSEN ISO:7396-1:2007 Appropriate Test Certificate/report with reliable warranty of product/accessories from OEM shall be submitted. the product should be CE Certified/ CE Marked. All as per pre approved by Engineer in charge. for additional technical parameters of products/work, refer Annexture"A" attached with P.W.D. Electrical B.S.R. 2022.
For Three Gas Services
SITC of Bed Head Panel of 1200 MM long made out from high strength extruded aluminium with powder coating with at least 4 nos 6/16 Amp switch socket and provision for required number of gas outlet points as suggested by the client. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. The Product should be CE Certified / CE Marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with P.W.D. Electrical B.S.R. 2022.
P&F of Bed Panel accessories like Monitor Tray, Utility Basket, Vacuum Slider, Infusion Pump Pole with IV hooks, with proper nut bolts and screw and with proper finishing. Appropriate Test Certificate/ report of product/accessories from OEM shall be submitted. The Product should be CE Certified / CE Marked. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with P.W.D. Electrical B.S.R. 2022.
Monitor Tray
Utility Basket
Vacuum Slider
Infusion Pump Pole
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
Tendernotice_2.pdf
PDF • 1.90 MB
BOQ_939047.xls
BOQ • 0.35 MB
Cover4.pdf
Tender Documents • 0.30 MB
Download all tender documents and submit your bid