Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC PANDABESWAR PASCHIM BURDWAN 713346 | PANDABESWAR | PASCHIM BURDWAN | WEST BENGAL | 713346 | L1 | Accepted-AOC AS PER TCR | |
| 2 | L2₹19.6 L+₹15,968.44 (0.82%)Rejected-Finance BARDHAMAN BARDHAMAN 713378 WEST BENGAL INDIA | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713378 | L2 | Rejected-Finance REJECTED AS PER TCR | |
| 3 | L3₹19.7 L+₹30,959.87 (1.59%)Rejected-Finance LAUDOHA LAUDOHA P S FARIDPUR BARDHAMAN BARDHAMAN WEST BENGAL 713385 | BARDHAMAN | BARDHAMAN | WEST BENGAL | 713385 | L3 | Rejected-Finance REJECTED AS PER TCR |
Tender Value
₹19.4 L
EMD Value
₹24,300
Closing Date
14 Jan 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GENERAL MANAGER, JHANJRA AREA
OFFICE OF THE GENERAL MANAGER, JHANJRA AREA, PO-LAUDOHA, BO, DIST. - PASCHIM BARDHAMAN, PIN-713385
Trans, install, fabri, commi trial run extension of one no. 1000mm width, 1x90kW, 550V, single drive belt conveyor along 79L from -11D to 2D for development of trunk panel-F1 in R-VIIA seam at 3n4 Incline, J.P.C
2022_ECL_266391_1
ECL/GM/JNR/EnM/e-Tender/ 22-23/A2/64,Dt.30.12.2022
Open Tender
Miscellaneous Works
Item Rate
60 days
JHANJRA UNDERGROUND
PLEASE REFER TENDER DOCUMENT
4 documents required · 4 mandatory
₹24,300
9 Mar 2023
3 Jan 2023
16 Jan 2023
3 Jan 2023
14 Jan 2023
4 Jan 2023
3 Jan 2023 - 9 Jan 2023
Amount
Transportation, installation, necessary fabrication, commissioning & trial run including extension of one no. 1000mm width, 1x90kW, 550V, single drive belt conveyor along 79L from -11D to 2D for development of trunk panel-F1 in R-VIIA seam at 3&4 Incline, J.P.Colly
Transportation of the 1000mm width, 1x90kW, 550V Drive Head complete including gear box, motor(90kW/550V), base frame, couplings, bearing blocks, fencing etc from surface and installation at 79L/-10D (R-VIIA) with necessary fabrication job.
Transportation of Discharge Unit complete with girders, strike plate, chute plates, scrappers etc from surface and installation at 79L/-11D (R-VIIA) with necessary fabrication job.
Transportation of Loop Take Up Unit complete with motorized winch from surface and installation at 79L/[(-10D)-(-9D)] (R-VIIA) with necessary fabrication job.
Transportation of Tail end unit complete with fencing from surface and installation at 79L/-8D (R-VIIA) with necessary fabrication job.
Transportation of 110mtr. 1000mm belt conveyor structure complete with stringer, foot stool, top bracket, top & bottom roller etc. from surface to 79L belt installation site and installation from 79L/-11D to 79L/-8D in R-VIIA seam.
Loading, transportation and unloading of one breaker(550V/200A), starter(550V/90kW), LS unit from surface to 79L/-10D(R-VIIA) with help of haulages & 150mtr manually. (Distance- approx. 2600mtr.)
Transportation of 250mtr 3.3kV grade 70 sq.mm. PVCDWA cable from surface to 72L/-11D(R-VIIA) with help of haulages. (Distance- approx. 2600mtr.)
Laying-hanging this 250mtr 3.3kV grade 70 sq.mm. PVCDWA cable from 72L/- 11D ACB to 79L/-10D ACB manually.
Transportation of 250mtr. 1000mm width PVC belting from surface to 79L belt installation site with help of haulages & 150mtr manually. (Distance- approx. 2600 mtr.)
Laying, lapping, jointing & tensioning of this 250mtr. 1000mm width PVC belting in proposed 79L belt.
Transportation of 150 mtr belt sequence cable from surface to 76L/-11D(R-VIIA); then laying-placing them from 76L/-11D starter to 79L/-10D starter in R-VIIA seam.
Transportation of pull cords with its cable, communication devices with its cable, signaling system (8-SWG GI wire, bobbin insulators & 3/8" X 3" MS Bolt-nut) from surface to 79L belt installation site with help of haulages for 110mtr. belt and laying-placing them from 79L/-11D to 79L/-8D in R-VIIA seam.
Testing, trial run, alignment & commissioning of this belt conveyor from 79L/-11D to 79L/-8D in R-VIIA seam.
Twelve times extension of the proposed 79L belt conveyor from 79L/-8D to 79L/2D for a length of 345 mtr. in R- VIIA seam of 3&4 Incline Unit, JPC.
Ten times dismantling of tail end unit complete for Ten times belt extension of proposed 79L belt.
Ten times transportation and installation of tail end unit complete for ten times belt extension of proposed 79L belt from 79L/-7D (R-VIIA) to 79L/2D (R-VIIA).
Transportation of 1000mm belt structures (i.e. foot stools, channels, brackets, top and bottom rollers etc.) for a length of 345mtr. from surface to belt extension site by haulages and installation them from 79L/-8D to 79L/2D in R-VIIA seam during ten times belt extension. *Each time belt extension will be for a length of 34.5 mtr.
Transportation of 690mtr. 1000mm PVC belting from surface through haulages & 200mtr. manually to 79L(R-VIIA) belt extension site.
Laying, Lapping, Jointing & Tensioning of this 690mtr. 1000mm belting from 79L/-8D to 79L/2D in R-VIIA seam during ten times belt extension and trial run.
Transportation of pull cords with its cable, communication devices with its cable, signalling system (8-SWG GI wire, bobbin insulators & 3/8" X 3" MS Bolt-nut) for 345 mtr. belt from surface to 79L belt extension site and laying & fitting them during ten times belt extension.
Civil foundation works for installation of 1X90kW, 550V, 1000mm wide belt conveyer drive head, discharge unit, loop take-up unit and platform for ACB, Starter for 79L belt conveyor of 3&4 incline, JPC.
Recess cutting in stone
Cleaning of debris/muck
Sand filling
Brickwork with fly ash bricks in foundation & plinth in cement mortar 1:6
Providing and lying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement :2 coarse sand (zone- III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources.
12mm cement plaster of mix 1:6
Loading material into tub and unloading at site.
Roof heightening by drilling blasting in stone, cleaning, roof bolting including cost of drill rod, drill bit for the installation of proposed 79L belt conveyor in R-VIIA seam of 3&4 incline JPC
Roof heightening by drilling, blasting in stone including dressing, cleaning with cost of drill rod and drill bit. ( Excluding cost of explosive & detonator).
Roof bolting including carrying of materials from surface to u/g side, drilling, grouting & cost of drill rod and drill bit.
Supply of Materials
Supply of DA cylinder
Supply of oxygen cylinder
Supply of MS NUT BOLT 5/8”X2”
Supply of HT NUT BOLT of M20X75mm
Supply of HT NUT BOLT of M20X65mm
Total impact of GST for the purpose of CTC
BABLU SINHA
RINA ENTERPRISE
stage.html
html • 0.04 MB
techsummary_275565.pdf
PDF • 3.00 MB
finsummary_275565.pdf
PDF • 3.00 MB
WO64.pdf
PDF • 4.52 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .