Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹17.0 L+₹1.8 L (11.5%)Rejected-Finance MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L3₹18.5 L+₹3.3 L (21.6%)Rejected-Finance | L3 | Rejected-Finance GREATER THAN L1 | |
| 4 | L4₹20.8 L+₹5.6 L (36.8%)Rejected-Finance | L4 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
3 Jan 2022, 6:00 pmClosed
P Bangar Raju,IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
SPL REPAIR TO ELECTRICAL WIRING AND FITTING OF CERTAIN MARRIED ACCOMMODATIONS AT INS SHIVAJI LONAVLA
2021_MES_494390_1
GE/LONAVLA/8038/E8
Open Tender
Civil Works
Item Rate
120 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹48,000
Yes
8 Feb 2022
13 Dec 2021
5 Jan 2022
13 Dec 2021
3 Jan 2022
21 Dec 2021
13 Dec 2021 - 20 Dec 2021
Amount
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed. (a) One light point or one fan point or bell point controlled by one switch
(b) One 3 pin socket outlet, 5 Amp independent
(c) One 3 pin socket outlet, 5 Amp on the same board with other switches
(d) One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size.
All as per item No.2 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately).
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
S & F socket out let, 2 in 1, 3 pin, 5 Amps, 240 volts complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed.
S & F Ceiling rose, 3 way PVC insulated body complete all as specified and directed by engineer in charge.
S/F switch bell push, flush type 5 Amp.
S&F in repairs bell, electronic type AC, 230 Volts single pole.
Labour only for taking down and fixing repairs to Ceiling Fan with Fan regulator, Exhaust Fan, any Make & any Sweep Oiling, Greasing , removing all dust with painting and Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing for serviceable condition complete all as directed by Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 18W, 220V,AC decorative type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete.Make: Bajaj(BLRB-DB 118,18W LED) or equivlent Philips/Havells
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make: Crompton or equivlent Bajaj/Philips/Havells
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Crompton or equivlent Bajaj/Philips/Havells
M&L lamp holder, PVC/ poly carbonate type with black plate suitable for batten fittings.
Supply and fix new adore LED lamp 9 Watt confirming to Cat No LHLDEUECNL8R009 of Havell's or euivalent in Philips / Bajaj
Taking down of Old MCB DB / control box any type any size including MCBs and separating the serviceable MCB DBs and MCBs for reuse at site
S&F in replacement vertical type DB (8 Way) Double door, (VTPN) suitable for and including MCCB 4 pole, 100 amps, 25KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 8 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and bolt including matching the existing surface all as specified and directed ,
S&F in replacemen MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in replacemen MCB DB SPN 12 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB SPN 32 AMP, 240 Volts 10KA 'C' curve , Complete all as specified and directed.
S&F in repairs MCB SPN 40 to 63 AMP, 240 Volts 10KA 'C' curve , Complete all as specified and directed.
S&F in repairs MCB SP 5 To 32 AMP, single pole 240 Volts 10KA 'C' curve, Complete all as specified and directed.
S&F in repairs MCB SP 32 to 63 ,single pole 240 Volts 10KA 'C' curve, Complete all as specified and directed.
S &F Sheet Metal single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB of capacity 20 A SP. Make : Standard/Havells
Taking down the unserviceable geysers (water heater) of any type and size, disconnecting the pipe line connection inlet and outlet connections, dismantling, cleaning geyser tank body properly and removal of scaling etc, Refixing the geyser after repair and connecting electric supply and testing of geyser for proper working complete all as specified and as directed.
S&F in repairs heating element of any type upto 2 Kw capacity complete all as specified and as directed.
S&F in repairs thermostat suitable for geyser up to 50 ltrs capacity complete all as specified and as directed.
S&F in repairs PVC connecting pipe with brass union fitted at both end suitable for connection to 15mm GI pipe, 450 mm long [15mm dia] for hot water supply complete all as specified and as directed.
Ditto - all as per item No 33 above but for cold water supply.
S&F in repairs rubber gasket for apparatus plate to suit the geyser assembly and water tank assembly complete all as specified and as directed.
S&F in repairs safety valve device to suit 15mm dia. GI pipe with lead seal complete all as specified and as directed.
S&F in repairs non return valve cast copper alloy, CP of 15mm dia complete all as specified and as directed.
S&F in repairs indicating lamp of geyser red & green complete all as specified and as directed.
S&F in replacement stop valve, cast copper alloy, wash down, high pressure with crutch or butterfly handle screwed both end for iron pipe or for union and fixed of 15 mm dia complete all as specified and as directed.
S&F in replacement GI pipe, medium grade of size 15 mm dia including all fittings and fixtures complete all as specified and as directed.
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x1.5 sq. mm + 1x1.5 sq. mm earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:- Two run of 1.5 sqmm wire and One run of 1 sqmm wire and One run of PVC casing caping will be measured as one running meter.
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x2.5 sq. mm + 1x2.5 sq. mm earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:- Two run of 2.5 sqmm wire and One run of 2.5 sqmm wire and One run of PVC casing caping will be measured as one running meter.
M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed.Note:- Two run of 6 sqmm wire and One run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter.
Taking down electric meter of any type and any make single/three phase by dismantling of all electrical connection checked the meter ,and refixed same Nos of meter on wooden board of suitable size in same Nos of qtr after repair works completed
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
ECOBUILD
Om Construction
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .