Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.0 LAccepted-AOC | 1 | Accepted-AOC L-1 Amount | |
| 2 | 2₹5.5 L+₹47,780 (9.56%)Rejected-Finance C 3 LAKHAN SONA NEAR RPS MORE BAILEY ROAD PATNA BIHAR PIN 801503 | PATNA | BIHAR | 801503 | 2 | Rejected-Finance L-2 | |
| 3 | Rejected-Technical VILLAGE DALGAONKHUTI POST P S DALGAON DIST DARRANG ASSAM PIN 784116 | DALGAON | DARRANG | ASSAM | 784116 | - | Rejected-Technical Not fulfill all criteria as per NIT |
| Sl No | Description | Qty | Unit | SHIV VIJAY ENGICON PRIVATE LIMITED L2 | HABRICK COMPANY L1 |
|---|---|---|---|---|---|
| 1.00Replacement of existing 11KV CT/PT set and maintenance GOBA switch, Drop out fuse set and 11KV AB cable at inside the campus | |||||
| 1.10 | 11 KV Combined CTPT set 75/5 A | 1 | No | 75,000 ₹75,000 | 70,000 ₹70,000 Lowest |
| 1.20 | Tension Insulator 11 KV -1-C 120 Sq.mm Covered conductor | 4 | No | 8,000 ₹8,000 | 6,800 ₹6,800 Lowest |
| 1.30 | Tension Hardware 11 KV -1-C 120 Sq. mm Covered Conductor | 4 | No | 10,800 ₹10,800 | 10,000 ₹10,000 Lowest |
| 1.40 | Cable Tie 11 KV -1-C 120 Sq.mm Covered Conductor | 4 | No | 4,920 ₹4,920 | 4,400 ₹4,400 Lowest |
| 1.50 | 11 KV Wedge Connectors | 12 | No | 24,000 ₹24,000 | 20,400 ₹20,400 Lowest |
| 1.60 | Aluminum Lugs (Assorted) | 6 | No | 480 ₹480 | 420 ₹420 Lowest |
| 2.00Servicing of 11kv Indoor VCB | |||||
| 2.10 | Servicing cum Overhauling of 11kV Indoor VCB including meggering, inspection of operation of make break, both electronically and mechanically checking. Rectifying the damages including replacement of spares as required. | 4 | JOB | 1,60,000 ₹1,60,000 | 1,34,000 ₹1,34,000 Lowest |
| 2.20 | Supplying of 11kV Indoor cast resin type indoor Current Transformer of Ratio 100-50/5-5A, 5P10, 15VA. | 1 | SET | 75,000 ₹75,000 Lowest | 75,000 ₹75,000 Lowest |
Tender Value
₹5.4 L
EMD Value
₹10,890
Closing Date
26 Jun 2025, 12:00 pmClosed
Commandant-210 CoBRA
210 CoBRA HQr,CRPF,Dalgaon,Darrang,Assam,784116
Replacement of existing 11KV CT/PT Set and maintenance of GOBA switch, Drop out fuse set and 11KV AB cable at inside the campus and servicing of 11KV indoor VCB at 210 Cobra, Dalgaon, Assam
2025_CRPF_865208_1
01/210 CoBRA HQr/2024-25
Open Tender
Electrical Works
Works
45 days
210 CoBRA HQr, CRPF, Dalgaon, 784116
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹10,890
Yes
4 Oct 2025
19 Jun 2025
27 Jun 2025
19 Jun 2025
26 Jun 2025
19 Jun 2025
Replacement of existing 11KV CT/PT set and maintenance GOBA switch, Drop out fuse set and 11KV AB cable at inside the campus
11 KV Combined CTPT set 75/5 A
Tension Insulator 11 KV -1-C 120 Sq.mm Covered conductor
Tension Hardware 11 KV -1-C 120 Sq. mm Covered Conductor
Cable Tie 11 KV -1-C 120 Sq.mm Covered Conductor
11 KV Wedge Connectors
Aluminum Lugs (Assorted)
Servicing of 11kv Indoor VCB
Servicing cum Overhauling of 11kV Indoor VCB including meggering, inspection of operation of make break, both electronically and mechanically checking. Rectifying the damages including replacement of spares as required.
Supplying of 11kV Indoor cast resin type indoor Current Transformer of Ratio 100-50/5-5A, 5P10, 15VA.
Supplying of Closing/Tripping Coil 110/24V DC
Supplying of 11kV Indoor Cast Resin type Potential Transformer of ratio11000/V3/110v/V3
Supplying of Spring Charging Motor 230v AC
Supplying of Three phase Ampere Meter
Supplying of Three phase Volt meter
Supplying of Spout assembly body for indoor Breaker
SHIV VIJAY ENGICON PRIVATE LIMITED (BID ID -3236720)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .