Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹44.8 L+₹4.4 L (10.9%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹47.1 L+₹6.7 L (16.5%)Rejected-Finance 67 RAMPURA GANDHI NAGAR JAMMU 180 004 J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹52.6 L+₹12.2 L (30.2%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹57.7 L+₹17.3 L (42.7%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹48.8 L
EMD Value
₹97,000
Closing Date
7 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jammu
Headquarters, CWE (AF) Jammu Near Gurdwara Sahib and Mandir Airforce Station Satwari, Jammu Pin - 180 003
PROVISION OF WORK OF COMMERCIAL POWER SUPPLY AND ASSOCIATED WORKS AT SHASHITAR UNDER GE AF JAMMU
2023_MES_585077_2
CWEAFJ-22/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Jammu
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Jammu
₹97,000
Yes
31 Jul 2023
10 May 2023
9 Jun 2023
10 May 2023
7 Jun 2023
24 May 2023
Amount
Excavating in trenches in hard / dense soil not exc. 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for laying of pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exc. 1.5 m in depth and getting out complete all as specified and as directed.
Excavating in trenches in hard / dense soil not exceeding 1.5 metre wide and depth exceeding 1.5 metre but not exceeding 3.0 metre for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exceeding 10 Sqm on plan and depth exceeding 1.5 m but not exceeding 3 m and getting out complete all as specified and directed.
Returning, filling in soil including spreading, levelling, watering & well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing surplus excavated soil to a distance not exc. 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in coping for poles benching including weathering slightly rounded or chamfered angles as directed including necessary form work and finishing the exposed surfaces complete all as specified and as directed.
Plain cement concrete 1:3:6 , type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed.
Steel tubular swaged pole complete with MS base plate 6 mm thick of size 300 mm x 300 mm, finial taper plug, bolts, nuts and washers and screws, type 410 - SP 55 (11 metre long) including drilling of holes of required size and nuts for fixing of cross arms, painting with a coat of red oxide zinc chrome primer and two coats of aluminium paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting five black / white bands at lower portion of pole each of 300 mm height at 300 mm spacing, complete all as specified and as directed.
Cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or as indicated and directed inclusive of two coats of aluminium paint over a coat of red oxide primer after preparation of surfaces, complete all as specified and as directed.
Switch Air Break Gang Operated Triple Pole mechanically operated from ground level mounted on 15 Nos polymer insulators and steel frame out door type switch for vertical installation single break provided with locking arrangement consisting of MS channel HT pole type with drop out fuses (expulsion fuse) of 25 Amps - 03 Nos operating rod of 25 mm dia GI pipe medium grade complete conforming to IS - 1318 rated voltage 11000 Volts and current rating 200 Amps complete all as specified and as directed.
Lightening arrestor expulsion type complete with all fittings transmission class, discharge capacity 65 KA and suitable for working voltage 11 KV confirming to IS-3070 complete all as specified and directed.
Supplying, installation, connecting electrically, commissioning and testing Servo Controlled Voltage Stabilizer for automatic operation three phase, copper wound, naturally oil cooled outdoor type and designed for input variation between 300 volts to 480 volts with output voltage stabilized at 415 volts with accuracy of +/- 1 % and speed of correction 8 volts per second and of capacity of 400 KVA complete with and including following accessories, protection and specifications :- (a) Suitable for input voltage range 300V-480V (b) Output Voltage stabilized at 415 Plus / Minus 1% (c) Rated frequency 50 Hz (d) Conforming to BIS 9815 Part-1 1994 (reaffirmed 2014)
(e) Wavelength distortion - NIL (f) No Load Losses less than 1.5% (g) On load losses 2.5% (h) Suitable for unbalanced voltage and unbalanced load (j) Outdoor type IP 55 protection (k) Auto/manual control for output voltage setting(by potential meter in auto mode and wish rise / lower button in manual mode) (l) Inbuilt under voltage/over voltage protection (m) Overload and short circuit protection (o) Single phase prevention system (p) Phase sequence and phase reversal protection
(q) By pass arrangement (r) Input/output voltage indicators for each phase (s) Output current and frequency indicator for each phase (t) MCCB of adequate capacity (u) First filling of transformer oil to the appropriate level and testing complete.
Supply, installation, testing and commissioning of Indoor type, Oil Cooled Isolation Transformer 400 KVA, IS-1180, Three Phase, metallic body, unbalanced type copper wound with standard fittings and accessories, input voltage of 415 volt +/- 5% Output Voltage 415 volt+/- 5%, IP-42, Vector group Dyn-11, of frequency 50Hz and with following description including first filling of transformer oil confirming to IS- 335 :-
(a) Method of cooling - Oil cooled. (b) Ratio - 1:1 (c) Insulation class - Class E (d) Winding Temperature - Less than 55º C (e) Full load losses - Less than 5% (f) No load losses - Less than 0.5% (g) Mounting - On wheel detachable type (h) Potential difference between Earth to Neutral voltage - Less than 01 Volts. Notes :- 1. In addition to the above all standard fittings to be provided as per ISI norms. 2. PCC foundation concrete and coping shall be as per OEM recommendation.
Supply, installation, Testing, Commissioning of Oil Cooled, copper wound, Step down' BIS marked & BEE star labelled' Transformer of capacity 315 KVA, plinth mounted, outdoor type with latest features complete with standard fitted HT 11 KV 3 phase, LT 433 Volts, Three Phase, 4 wire, 50 C/S oil immersed, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at + 2.5 % to + 5 % & + 7.5 % on HV side and to be changed by means of hand operated off load tap changing gear including first filling of new transformer oil of dielectric strength not less than 55 KV with all fittings and accessories such as LT box with cable gland, HT box with cable gland, Silica gel, breather, Oil level indicator gauge, drain out valve (oil tank), exhaust vent,
air release valve, temp gauge, cast iron wheel etc comply with EEL 2 IS-1180 2014 with amendment 1, 2, 3 & 4 having total losses @ 50% load 955 W & total losses @ 100% load 2750 Watts complete all as specified and directed. The Manufacturer must possess valid BIS license, BEE License, ISO Certificates and NABL approved Laboratory to ascertain genuineness of the product quality. The Transformer shall be supplied with the following items / accessories. The rates of these items / accessories shall be deemed to be included in the Quoted Rate and nothing extra from the government shall be admissible on this account what-so-ever :- (a) Three Nos porcelain bushing HT 11 KV with brass bushing rods, nuts, bolts & washers etc inside cable end box.
(b) One cable box LV side consisting of 4 Nos porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT UG cable. (d) Dehydrating breather with first fill of dehydrating agent. (e) Explosion vents. (f) Thermometer pocket on tank cover. (g) One No 100mm dia, dial type thermometer vapour pressure type having range 0 to 120 degree centigrade (h) Rang plate and terminal marking plate. (j) Earthing arrangement. (k) Oil level gauge. (l) Oil drain filter valve. (m) Oil drain valve. (n) Lifting hook. (o) Oil conservator with filling hole and cap. (p) Air relief valve plug.
(q) Four plate solid cast steel detachable rollers. (r) Earth bushing for neutral outside the cable box for providing independent earthing for neutral. (s) Necessary channel on foundation for fixing the transformer with joint and stopper.
Supply, installation, testing and commissioning of LT Panel outdoor type, CPRI approved, suitable for LT 440 volts, 50 Hz, 3 Phase 4 wire supply system, double door type factory fabricated having independent cabin including locking arrangement for each MCCB, weather and vermin proof (Protection class IP-55), made out of 3.15 mm thick MS CRCA sheet with front and rear opening doors duly hinged upto full door height with special steel hinges, rubber lining, bake lite sheet, locking arrangements, on both side of the doors, powder coated internally and externally, CRCA sheet for panel shall be mounted on 50 mm x 50 mm x 5 mm angle iron frame and shall have channel base of appropriate size and mounted on PCC foundation built in PCC 1:3:6 type C-2 be using 40 mm graded crushed stone aggregate including earthwork complete,
as recommended by manufacturer but height not less than 30 cm above ground level, suitable for and comprising the following, complete all as specified and directed.
INCOMER (a) 630 Amps, 433 Volts, Four Pole, 50 Hz, 36 KA fixed manual type MCCB with 100% microprocessor based release for overcurrent, Surge protection relay, short circuit and earth fault. OUTGOING (a) 320 Amps, Four Pole, 25 KA MCCB with thermal magnetic release - 01 No. (b) 100 Amps, Four Pole, 25 KA MCCB with thermal magnetic release - 02 No. (c) 63 Amps, Four Pole, 25 KA MCCB with thermal magnetic release - 03 No. (d) Street Light Timer 63 Amps Single Phase - 02 Nos
(e) Multifunctional Digital Panel meter with LCD display flush mounting type of size 96 x 96 mm, accuracy Class-1, suitable for CTs with secondary current 05 Amps having provision of display parameters such as Voltage, Amps, Frequency, Power Factor, KW, KV etc. Qty - 01 No (f) Current Transformer of ratio 400 / 5 Amps, current rating primary upto 400 Amps and secondary 5 Amps accuracy Class 01, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice - 01 Set of Three
(g) LED Phase Indicator Lamp Qty - 01 Set of Three. (h) Digital Voltmeter 0 to 440 Volt
Supply, installation, testing and commissioning of LT Panel, Outdoor type, CPRI approved, suitable for LT 440 volts, 50 Hz, 3 Phase 4 wire supply system, double door type factory fabricated having independent cabin including locking arrangement for each MCCB, weather and vermin proof (Protection class IP-55), made out of 3.15 mm thick MS CRCA sheet with front and rear opening doors duly hinged upto full door height with special steel hinges, rubber lining, bakelite sheet, locking arrangements, on both side of the doors, powder coated internally and externally, CRCA sheet for panel shall be mounted on 50 mm x 50 mm x 5 mm angle iron frame and shall have channel base of appropriate size and mounted on PCC foundation built in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) including earthwork complete, as recommended by manufacturer :-
but height not less than 30cm above ground level, suitable for and comprising the following, complete all as specified and directed.
INCOMING : (a) Bus bar chamber comprising 4 Nos copper strip bus bars PVC insulated made of copper strip of size (50 x 5) mm, PVC sheathed with colour coding. (b) MCCB having current rating 250 - 320 Amps with rupturing cap 36 KA, AC 415 Volts four pole, Ics = 100% of Icu with adjustable thermal and Magnetic Release complete with spreader links. (Qty -01 No) (c) Onload Change over of rating 315 Amp Four Pole, 415 volts - 01 Nos
(d) Multifunctional Digital Panel meter with LCD display flush mounting type of size 96mm x 96mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Frequency, Power factor, KW, KV etc. (Qty - 01 No) (e) Current Transformer of ratio 400 / 5 amps, current rating primary upto 400 Amps and secondary 5 Amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice (f) LED Phase Indicator Lamp (Qty - 01 Set of Three).
OUTGOING (a) MCCB having current carrying rating 80 - 100 Amp with rupturing capacity 25 KA, AC 415 Volts Four Pole, Ics = 100% of Icu with adjustable thermal magnetic release complete with spreader links. (Qty- 02 Nos.) (b) MCCB having current carrying rating 25 - 32 Amp with rupturing capacity 25 KA, AC 415 Volts Four Pole, Ics = 100% of Icu with adjustable thermal magnetic release complete with spreader links. (Qty- 10 Nos.)
Notes for Serial Item No '14' & '15' : 1. The Panel shall be procurred from CPRI Approved authorised Channel Partner of ABB / CROMPTON / SCNEIDER / L&T / SEIMENS. 2. The Switchgears and all other accessories shall be of Make ABB / CROMPTON / SCHNEIDER / L&T / SEIMENS
Supplying, laying, jointing and testing in trenches/ ducts or fixing to pole / wall or passing through pipes XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor 11000 volts (Earthed) grade of size 120 Sqmm 3 core complete all as specified and directed.
Supplying, laying, jointing and testing in trenches/ ducts or fixing to pole / wall or passing through pipe XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor 1100 volts grade of size 630 Sqmm 1 core complete all as specified and directed.
Supplying, laying, jointing and testing in trenches/ ducts or fixing to pole / wall or passing through pipe XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor 1100 volts grade of size 300 Sqmm 3.5 core complete all as specified and directed.
Supplying, laying, jointing and testing in trenches/ ducts or fixing to pole / wall or passing through pipes XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor 1100 volts grade of size 150 Sqmm 3.5 core complete all as specified and directed.
Supplying, laying, jointing and testing in trenches/ ducts or fixing to pole / wall or passing through pipes XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor 1100 volts grade of size 70 Sqmm 3.5 core complete all as specified and directed.
Supplying, laying, jointing and testing in trenches/ ducts or fixing to pole / wall or passing through pipes XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor 1100 volts grade of size 25 Sqmm 4 core complete all as specified and directed.
Supplying, laying, jointing and testing in trenches/ ducts or fixing to pole / wall or passing through pipes XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor 1100 volts grade of size 16 Sqmm 2 core complete all as specified and directed. Note for Item No 16 to 22 : All cables shall be provided with stainless steel gland of adequate size for in/out connections in all panels, DBs, junction boxes as required at site and should be properly earthed complete all as directed. Cost of same shall deemed to be included in quoted rates of cables.
Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and as directed.
Cable jointing kit for 1.1 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 Sqmm to 300 Sqmm complete all as specified and as directed.
Cable jointing kit for 1.1 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 150 Sqmm complete all as specified and as directed.
DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 120 mm and inner dia 103 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, 'O' Ring etc., for protection of cable complete all as specified and as directed.
Sand cushioning to under ground cable, provided with 8 cm thick layer before laying the cable and 15 cm thick layer after laying and stretching the cable complete all as specified and directed. Note : Sand cushioning to be punned as per SSR Part-I and punned thickness only to be measured and paid.
Bricks Sub Class 'B' old size well brunt clay bricks of size 230 x 115 x 75 mm as a mechanical protection to the electric cable laid dry flat in the trenches across the length of the cable complete all as specified and directed.
GI Tubing light grade 80 mm bore fixed to wall /poles etc. or laid in floors/ or in trenches for road crossing with and including all fittings as required complete all as specified and as directed.
GI Tubing light grade 50 mm bore fixed to wall /poles etc. or laid in floors/ or in trenches for road crossing with and including all fittings as required complete all as specified and as directed.
GI Tubing light grade 40 mm bore fixed to wall /poles etc. or laid in floors/ or in trenches for road crossing with and including all fittings as required complete all as specified and as directed. Note for Serial Item No '30' to '32' : Excavation and earthwork shall be measured and paid for separately.
Earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically (earth plate not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to and including earth lead of GI Strip 32 x 6mm size by means of steel bolts, nuts, check nuts and washers test points made of GI strip 40 x 8 mm , 10 cm long, PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate), in pit, angle iron 25 x 25 x 3 mm frame work with precast RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) cover reinforced with 8 mm dia TMT bars @ 150 mm C/C both ways and 12 mm dia MS fabricated handle, light grade GI watering pipe 20 mm bore with funnel, wire mesh and light grade GI protection pipe 40 mm bore upto 7.5 m length for drawing in earth lead, salt, charcoal etc. including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50 m complete all as shown in electrical plate No. 3 of MES schedule 2009 Part-I Including connecting and testing on completion all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically (earth plate not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to and including earth lead of GI earth lead wire 4.00 mm dia by means of G.I. thimbles, bolts, nuts, check nuts and washers, PCC 1:2:4 type B - 1 (using 20 mm graded crushed stone aggregate), in pit, angle iron 25 x 25 x 3 mm frame work with precast RCC 1:2:4 type B -1 (using 20 mm graded crushed stone aggregate) cover reinforced with 8 mm dia TMT bars @ 150 mm C/C both ways and 12 mm dia MS fabricated handle, light grade GI watering pipe 20 mm bore with funnel, wire mesh and light grade GI protection pipe 15 mm bore upto 7.5 m length for drawing in earth lead, salt, charcoal etc. including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50 m complete all as shown in electrical plate No. 3 of MES schedule 2009 Part-I Including connecting and testing on completion all as specified and as directed.
Danger Notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. Clamps, bolts and nuts of approved size, for HT, 25cm x 20cm size including dismantling existing unserviceable one and depositing in MES store yard complete all as specified and directed.
Construction of Brick Masonry Platform in cement mortar 1:4 of size 3000 x 2500 x1200 mm for voltage stabilizer having sides finished with brick work with plaster complete with PCC foundation of 1:5:10 & PCC platform at top with 30 cm thick of PCC 1:5:10 and 10 cm thick of PCC 1:2:4 and having brick steps at one side, complete with XPM Jalli duly welded with angle iron of size 50 mm x 50 mm x 6 mm all around upto 1.5 metre, including excavation and earth work in any type soil, returning filling in and removal of surplus soil upto 50 metre complete all as shown on drawing or as directed.
Rough excavation not exceeding 1.5 metre deep and getting out in any type of soil complete all as specified and as directed.
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and as directed.
Walling of random rubble stone masonry uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6, complete all as specified and as directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints of random rubble stone masonry walling, uncoursed or brought upto courses hammer dressing with max. depression on face from straight edge held against the dressed surface not exceeding 20 mm for lime or sand stone complete all as specified and directed.
Rendering 20 mm thick in CM (1:4) on stone masonry surfaces finished even and fair without using extra cement complete all as specified and as directed.
150mm thick, plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
75mm thick, PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in flooring finished even and smooth without using extra cement complete, all as specified and as directed.
Cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregate as in columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and as directed.
Rolled sections as in main and cross beams, hip and jack rafters : purlins where connected to common rafters and running rails and guides for sliding doors : fixed with angle cleats or other connecting plates of grade Fe - 410-W (Gde-E-250) quality-'A' complete all as specified and as directed.
Plates (plain or chequered) channels, square cut or notched ordinary and counter sunk) forming holes, without any attachment of Grade Fe - 410 - W (Gde - E -250) quality - 'A' complete all as specified and as directed.
Hand rails, half round or other steel section or core for wooden hand rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc., wind tiles for roof including securing bolts ; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe - 290 Gde E - 165 complete all as specified and as directed.
Galvanised, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with 'L' or 'J' type or cranked hook bolts in roofs, walls etc. with grade of zinc coating 275 complete all as specified and as directed.
Cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection 50 mm thick, complete all as specified and as directed.
Hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Two coats of synthetic enamel paint (camouflage pattern) over a coat of red oxide primer on steel surfaces including preparation of new steel surfaces over 10 cm width or girth complete, all as specified and as directed.
Two coats of cement base paint over a coat of primer including preparation of newly plastered surfaces complete, all as specified and as directed.
Spreading, levelling, watering and ramming of soil in layers not exceeding 25 cm thick in floors complete all as specified and as directed.
NATIONAL TRADING COMPANY
Electromechanics Engineers & Contractors
RAVI KUMAR
Continental Enterprises
Bidder Name
ANIKET TRADERS
RAVI KUMAR
Continental Enterprises
Electromechanics Engineers & Contractors
NATIONAL TRADING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .