Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.1 LAdmitted-Finance | ₹49.1 L | L1 | Admitted-Finance |
| 2 | L2₹49.4 L+₹24,111 (0.49%)Admitted-Finance | ₹49.4 L+₹24,111 (0.49%) | L2 | Admitted-Finance |
| 3 | L3₹51.0 L+₹1.9 L (3.89%)Admitted-Finance | ₹51.0 L+₹1.9 L (3.89%) | L3 | Admitted-Finance |
| 4 | L4₹52.1 L+₹2.9 L (5.98%)Admitted-Finance | ₹52.1 L+₹2.9 L (5.98%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S FAMOUS ENGINEERS L3 | M/S WATT ELECTRICAL CONTRACTS L1 | SSF Construction And Supply Enterprises L4 | M/S ALJAN ENGINEERS AND CO L2 |
|---|---|---|---|---|---|---|---|
| 1.00A) SUB‐STATION MAIN EQUIPMENT:- | |||||||
| 2.00 | Supply, Installation, Testing & Commissioning of 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) | 3 | No. | 54,166 ₹1,62,498 | 35,000 ₹1,05,000 Lowest | 45,000 ₹1,35,000 | 85,500 ₹2,56,500 |
| 3.00 | Supply, Installation, Testing & Commissioning of 33kV Isolator without Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA) | 1 | set | 55,000 ₹55,000 Lowest | 70,000 ₹70,000 | 65,000 ₹65,000 | 98,600 ₹98,600 |
| 4.00 | Supply, Installation, Testing & Commissioning of 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224mm | 3 | No | 1,400 ₹4,200 Lowest | 1,500 ₹4,500 | 3,000 ₹9,000 | 4,500 ₹13,500 |
| 5.00 | Supply, Installation, Testing & Commissioning of 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 1 No per phase | 3 | set | 20,000 ₹60,000 | 8,500 ₹25,500 Lowest | 17,000 ₹51,000 | 28,600 ₹85,800 |
| 6.00 | Supply, Installation, Testing & Commissioning of 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port | 1 | No | 3,94,500 ₹3,94,500 | 5,21,212 ₹5,21,212 | 2,80,000 ₹2,80,000 Lowest | 3,97,000 ₹3,97,000 |
| 7.00 | Supply, Installation, Testing & Commissioning of 33KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) | 1 | No | 4,38,000 ₹4,38,000 | 4,87,867 ₹4,87,867 | 3,10,000 ₹3,10,000 Lowest | 3,98,000 ₹3,98,000 |
| 8.00 | Supply and errection of 11 Mtr. Long ST Poles ( ST-410 SP 56) with welded steel base plate and top cap including excavation of pit and back filling by boulders as per REC construction Standard (with latest amendments if any). | 4 | No | 33,000 ₹1,32,000 | 35,786 ₹1,43,144 | 30,000 ₹1,20,000 | 28,000 ₹1,12,000 Lowest |
| 9.00 | Providing and laying of Cement bottoming 1:2:4 mix using 20mm crushed stone aggregate including shuttering, form work etc as per REC standards 0.66cum
/pole | 4 | No | 1,000 ₹4,000 Lowest | 3,521 ₹14,084 | 7,000 ₹28,000 | 4,500 ₹18,000 |
| 10.00 | Providing and fixing of Earthing of poles/isolator, Complete by GI Pipe 40 mm/GI Rod 20mm, 3 mtr long through GI Strip (25x3)mm | 7 | No | 3,400 ₹23,800 | 1,212 ₹8,484 Lowest | 3,500 ₹24,500 | 1,500 ₹10,500 |
Tender Value
₹56.2 L
EMD Value
₹1.1 L
Closing Date
20 May 2026, 4:30 pmClosed
Executive Engineer, STD-II, Rajbagh,Srinagar
Office of the Executive Engineer, STD-II, Rajbagh
Providing Power supply to transit accommodation of Kakanmaran, District Budgam by way of augmentation of 33 11KV 1X10 MVA Receiving station Waterwani
2026_PDD_309857_1
eNIT No STD-II / 70 of 2025-26 Dated 11-03-2026-
Open Tender
Electrical Works
Turn-key
Budgam
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Executive Engineer, STD-II, Rajbagh,Srinagar
₹1.1 L
25 May 2026
13 May 2026
21 May 2026
13 May 2026
20 May 2026
13 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | A) SUB‐STATION MAIN EQUIPMENT:- | - | - | - | - |
| 2 | Supply, Installation, Testing & Commissioning of 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) | 3 | No. | - | - |
| 3 | Supply, Installation, Testing & Commissioning of 33kV Isolator without Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA) | 1 | set | - | - |
| 4 | Supply, Installation, Testing & Commissioning of 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224mm | 3 | No | - | - |
| 5 | Supply, Installation, Testing & Commissioning of 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 1 No per phase | 3 | set | - | - |
| 6 | Supply, Installation, Testing & Commissioning of 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port | 1 | No | - | - |
| 7 | Supply, Installation, Testing & Commissioning of 33KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) | 1 | No | - | - |
| 8 | Supply and errection of 11 Mtr. Long ST Poles ( ST-410 SP 56) with welded steel base plate and top cap including excavation of pit and back filling by boulders as per REC construction Standard (with latest amendments if any). | 4 | No | - | - |
| 9 | Providing and laying of Cement bottoming 1:2:4 mix using 20mm crushed stone aggregate including shuttering, form work etc as per REC standards 0.66cum
/pole | 4 | No | - | - |
| 10 | Providing and fixing of Earthing of poles/isolator, Complete by GI Pipe 40 mm/GI Rod 20mm, 3 mtr long through GI Strip (25x3)mm | 7 | No | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tendernotice_2.pdf
PDF • 1.59 MB
BOQ_1002809.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .