PROVN OF 6 X PASSENGER CAPACITY LIFT AT CC - 156 BLDG AT AWC (SPL WK) UNDER GE AWC MHOW
2023_MES_632432_2
CWE/MHOW/06 (T) of 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HQ CWE Mhow
As per tender documents
8 documents required · 8 mandatory
₹500
GE AWC Mhow
₹77,000
28 Mar 2024
24 Jan 2024
19 Feb 2024
24 Jan 2024
17 Feb 2024
29 Jan 2024
Amount
Design supply, install, testing and commissioning of 06 passengers Machine Room Less (MRL) COPD Lift, speed 1.0 metre/sec, lift with Permanent Magnet Synchronous Machine of 415 volts, 3 phase, 50 Hz AC supply conforming to IS-14665, suitable to serve G + 2 floors, with only 2 stops and 2 landings with AC Variable Voltage & Variable Frequency drive (VVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening sliding steel door with hairline finish of not less than 1.5 mm thick with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescuer device (ARD) system with batteries, 3D infra red sensor in full height of door & built in announcing system without hand set, complete all as specified and directed.
(a) TECHNICAL SPECIFICATIONS (i) Type & Capacity : Passenger elevator for 06 persons (408 Kg) with rear side glass. (ii) Type of drive: Variable voltage and variable frequency drive with microprocessor based controller + 5 mm landing accuracy with speed encoder. (iii) Speed: 1.0 meter per second with single speed motor. (iv) Travel: Suitable for passenger travel of Approx 09 meters, (opening on same sides). (v) Power supply: 03 Phase, 415 V, 50Hz (should withstand variation of + 5%). (vi) Well size to be constructed: 1810 mm x 1600 mm deep (over plaster) (approx) without any projected beam/column. (vii) Head Room height : 4200 mm (viii) Inner size: 1100mm x 1000mm deep x 2300 mm high. (ix) Type of machine: Gearless (x) Landing door: Automatic center opening with VVVF door drive, opening not less than 800 mm wide x 2100 mm internal height, sliding type, fabricated by stainless steel not less than 1.5 mm thick having hairline finish. (xi) Car enclosure: Side walls and front wall- Stainless steel panel body of not less than 1.5 mm thick with hairline finish. Rear wall - Plain Glass Panel Handrail - Glass wall handrail tube D38 (HR81) Mirror Polished SS Handrail at Rear Wall Ceiling & Lighting- Tubo spot light straight Silver Bear Blast StSt Tubo spot LED light
(xi) Flooring: 20 mm recess for Stone flooring / as per OEM design. Car skirting material - Stainless steel Hairline. (xii) Electric light: LED Light fitting (Min 04 Nos). (xiii) Fan: Concealed arial / cross flow fan with auto cut-off system and stainless steel grill / wire mesh for protection. (xiv) Car entrance: Automatic, centre opening, sliding doors. (xvi) Operation door: Automatic operation with stainless steel frame front opening landing door of Stainless steel hairline finish not less than 1.5 mm thick. (xvii) Control: Simplex full collective with and without attendant. (xviii) Indicators: Hall position indicators for car & landing direction and position indicator with stainless steel fixtures at all floors. (xix) Main drive and control shall be latest, high efficient and low power consumption. (b) STANDARD FEATURES (i) Anti nuisance car call protection. (ii) Automatic car return device (home landing). (iii) Independent service (for duplex only). (iv) Overloading device with tripping system including warning indicator both audio and visual types . (v) Nudging buzzer if door is held open for more than 30 sec..
(vi) Emergency fireman’s service. (vii) Audible car call button. (viii) Emergency car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time protection. (xi) Emergency alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation. (xv) Suitable phase reverse relay shall be provided to the controller to protect lift against phase reversal, phase failure and low voltage. (xvi) Set of three limit switches at the bottom and top most position of lift hoist ways as specified in IS. (xvii) Indoor communication to be connected with nearest security post. (xviii) Terminal Buffers: Metal special spring/PU/Oil buffers as per OEM. The buffering stroke should not be less than 200 mm. (xix) Car & Counter weight guide: Guide rails of MS 'T' section as per OEM design; counter weight shall be as per recommendation of OEM.
(c) ADDITIONAL FEATURES (i) Automatic rescue device: During power failure and manual operation suitable provision shall be provided to run the lift with full load to the nearest floor (ii) Floor announcement system: Each floor shall be provided with announcement system.
(d) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16-segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) . (iii) Door open/Door closed on car operating panel. (iv) 2-way intercommunication system. (v) Monochrome LED digital position indicator display. (vi) Battery operated alarm bell & emergency light (rechargable) along with suitable maintenance free batteries. (This system should be separate from ARD batteries) (vii) Fireman’s switch at main lobby. (viii) Manual rescue operation. (ix) Call direction indicator in car and landings. (x) Attendant operation system in car panel.
NOTES FOR ITEM No 1 : (a) The lift well shall be constructed as per OEM requirement. (b) The rates quoted shall be deemed to be inclusive of the following:- (i) 25A, 40A , 63A/300 mA ELCB (4 pole) rating for 3 phase - 1 nos (ii) MCB 16 A (2 pole) - 1 nos (iii) 2 core 2.5 Sqmm Armored Copper cable for single phase supply. (iv) Bulkhead fittings with 3 pin power socket (16 Amps) with ON OFF switch at 1 mtr from pit and rest at 2.5 mtr height upto headroom & metallic glands and lugs for cable entry in mains for 2 phase and 1 phase Power supply. (v) Plaster finish and whitewash in Lift well (c) Contractor should keep the lift functional by repairing/replacing the components only by OEM during the defects liability period.
Supplying, laying, fixing, jointing and testing of LT XLPE insulated, galvanized steel strip or wire armored heavy duty electric cable with aluminum conductor, 1100 volt grade, cross sectional area 10 sqmm x 4 core IS 7098 marked with electric connection, lugs/in GI pipes incl connection to LT panels with gland all as specified and as directed.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes etc. and getting out all excavated material in any type of soil incl breaking PCC paved tiles , complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Material and labour for approved river sand cushioning for under ground cable in trenches 8 cm before laying and 15 cm after laying of cable and punned thickness of sand shall be measured and paid for 18 cm only after punned/consolidated thickness complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LVV, Type-1, flat, size 250mm x 150mm x 40mm, ISI marked, laid flat across the cable length all as per specification and all as directed.
S&F GI tubing, light grade, ISI marked 40 mm bore pipe laid in trenches/duct or in road crossing or fixed to wall/poles for protection of cable complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation , filling and mass concerete complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 using 20 mm graded stone aggregate for coping of pole , pedestrial for LT panel complete all as specified and as directed.
Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm dong complete including nut bolt and washers as specified and directed.
Supply & fix aluminium strip 25mm x 3.15 mm complete with saddles and fixing screws for fitting the strip as specified and directed.
M&L for Earth test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth strip of size 32mm x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 5, connected to earthing test point complete including testing on completion all as specified.
M&L for Earthing complete with Copper earth plate electrode 300 x 300 x 3.15 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to copper earth strip of size 25mm x4mm mm by means of bolts, nuts, check nuts and washers of copper strip up to 15 .0 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 5, connected to earthing test point complete including testing on completion all as specified.
Excavation over area, not exceeding 1.5 M depth for foundations and additional 1.5m or part thereof in depth beyond the first 1.5m depth etc., and getting out in hard/dense soil. complete all as specified and directed.
Use and waste of form work to sides of concrete foundation, footings, bases column, raft and raft beams, plinth beams etc. rough finished surface of concrete.r complete all as pecified and directed.
Use and waste of form work to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attaches pillasters, buttresses, etc vertical or to batter including supports as specified and directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exceeding 200mm thick ( horizontal or sloping) including supports as specified and directed.
M & L for RCC design mix (M-30) as in walls , retaining walls any thickness above top of footings including attached pilasters and buttresses complete as specified and directed.
M & L for RCC design mix (M-30) as in foundation, footing, plinth beam etc complete as specified and directed.
M & L for RCC design mix (M-30) as in colums, posts and strut complete as specified and directed.
M & L for RCC design mix (M-30) as in slabs supported on walls etc complete as specified and directed.
M&L for mild steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as pecified and directed.
Ditto, all as per item No 23 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers,distribution and binders.
M&L in repairs for heritage regular flakes finish which is made from china clay, pigments homo polymer emulsion and bonding agent Acrylic emulsion Top coat (glossy/matt finished) based on solvent based polymer 0.8mm to 1.2mm thick single coat as per approved shade, as per manufacturers instructions and applying on vertical surfaces of walls, columns, pipes soffits of beams and chajja etc complete all as specified and directed. Make:-BAKELITE HYLUM LTD brandHeritage/DOLPHIN/LUXTURE as approved by GE
M & L rendering 10 mm thick on brick wall/cement block wall or concrete surfaces in cement mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L Granite 20 mm thick(of any type) work (table rubbed and polished) in for wall lining ( veenering to wall i.e. vertical surfaces ) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and as directed.
M & L fully body vitrified coloured tiles 9-10 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm , in floors etc.set jointed in neat cement sluury and pointed in white or coloured cement to match over & incl 15 mm thick screed bed built in CM 1:6, complete all as specified and directed
M&L Water proofing treatment on "Non approachable / non accessible roof" surface (Horizontal & Vertical surfaces) in following sequence through authorized applicator of the manufacturer all as specified and directed . (i) Surface prepration like opening the cracks/removal of loose concerete. (ii) Pressure washing the entire roof to remove dirt , dust alage fungi or other contaminants from joints and entire surface. (iii) Saturation of surface nano technology based deep penetrating sealer application to block pores , capillaries and micro cracks. (iv) Filling the crack with flexible polymer based caulk and further sealing with reinforcement fabric elastomeric coating. (v) Sealing joints and coving area with flexi reinforcement fabric and elastomeric coating. (vi) Priming coat of dr fixit URP (vii) First and Second coat of elastomeric dr fixit Roof Seal . The authorized applicators are under :- (i) P Tech Solutions 92 Anurag Nagar Ring Road Indore (II) MR clean Ventures E-4/402 Arera Colony Bhopal 462016 (iii) Property care, 244 D scheme No 71 Near Shriji Vatika indore 452002 Note : A warranty of 10 years be provided by the contractor for the service rendered.
M&L for Moorum / Red Bajari filling in floor or pavings, laid in layers n. exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M&L for providing and fixing 12mm thick frameless toughened glass from saint gobin/ guardian ltd ( colour as approved by engineer in charge ) including providing and fixing top , bottom and end sides with requisite stainless studs / brackets all complete as per direction of enginner in charge. NOTE :- (a) all silicon filling to ensure water proofing is included in this item. (b) work has to be carried out upto 15m.
M/s Dhapola Elevator and Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .