| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L1 | Accepted-AOC Accepted | |
| 2 | L2₹7.8 L+₹55,255 (7.63%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹9.5 L+₹2.3 L (31.1%)Rejected-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L3 | Rejected-AOC Rejected | |
| 4 | Rejected-Technical VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | - | Rejected-Technical Mismatch in the DD No mentioned in application and the DD No of Scanned DD |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
31 Oct 2020, 6:00 pmClosed
AGE (I) TALBEHAT
AGE (I) TALBEHAT LAKE VIEW CAMP TALBEHAT PIN-284125
REWIRING TO CERTAIN BLDGS OF ZONE 11 AND ZONE 06 AT MIL STN TALBEHAT
2020_MES_383636_1
AGE(I)/TBT/TOK-27/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) TALBEHAT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE (I) TALBEHAT
₹20,000
Yes
4 Dec 2020
5 Oct 2020
5 Nov 2020
5 Oct 2020
31 Oct 2020
19 Oct 2020
Amount
Taking down carefully copper/Aluminium point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc complete all as specified and as directed by Engineer-in-Charge
Taking down Distribution Boards along with MCB's including removing the same from site and making good to the disturbed surface complete all as specified and as directed by Engineer-in-Charge. Note: All taken down MCBs should be deposited to MES store by the contractor without any extra charge.
Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe etc complete all as specified and as directed by Engineer-in-Charge.
M/L for point wiring concealed type with 1.5sq mm FRLS PVC insulated unsheathed single core multi-threaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing capping and its accessories.
One light/fan point controlled by one No. piano type switch 5 Amp single pole one way
One bell/buzzer point controlled by one push button on the same board with other switches or independent.
One light point controlled by 2-way piano type switches 5 Amp two way for stair case.
One socket outlet 5/3 pin 6 Amp controlled by one switch on the same board.
One socket outlet 5/3 pin 6 Amp controlled by one switch on independent board.
All as per item NO 4.00 above but 3 pin socket out let 15/16 Amp on the independent Board all as specified with single core unsheathed PVC insulated cable multi-stranded copper conductor of size 2.5 sq mm for phase & neutral & 2.5 sq mm for earth continuity conductor.
S&F Switch Piano Flush button single pole one way 5/6 Amp. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Switch Piano Flush button single pole two way 5/6 Amp. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Switch Piano Flush button single pole one way 15/16 Amp. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F socket outlet 2 in 1, 3 pin & 2 pin, 5/6 Amp, 240 volt. (Non ISI Marked) MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F socket outlet 2 in 1, 3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt. (Non ISI Marked) MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F ceiling rose three phase PVC/Polycarbonate. (ISI Marked) MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F step type electronic fan regulator flush type on the existing phenolic laminated sheet. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Lamp hoder/Batten holder PVC/Polycarbonate insulated body with metal ring and back plate for batten fitting. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Bell Ding Dong type, AC 230 Volts, Single pole.(Non ISI Marked) MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Bell Push, flush type, 5 Amp, AC-230 Volts, single pole. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
M&L for sub main wiring with two single core PVC insulated of size 6 sqmm FRLS unsheathed copper conductor 1100 volt grade multi-standard and incl drawn through and including non- metallic rigid PVC, FRLS conduit and conduit accessories of 25 mm external dia and conduit FRLS accessories of ISI marks medium grade including 6.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- (i)One run of conduit three run of 6 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/casing capping and its accessories
M&L for sub main wiring with two single core PVC insulated of size 4.0 sqmm FRLS unsheathed copper conductor 1100 volt grade multi-standard and incl drawn through and including non- metallic rigid PVC conduit and conduit accessories of 20 mm external dia and conduit FRLS accessories of ISI marks medium grade including 4.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- (i)One run of conduit three run of 4 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/casing capping and its accessories.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug & socket complete with one single pole MCB of upto 20 Amp 240 volt complete all as specified and as directed by Engineer-in-Charge. Make:- Havells/Hager/Schneider.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way 240 volts double door (Metallic) type. Make:- Hager/IndoAsian/Siemens.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 4 way 240 volts double door (Metallic) type. Make:- Hager/IndoAsian/Siemens.
S&F sheet metal enclosure double door for MCB D B Triple pole and neutral 4 way, (4+12) 440 volts earth dolly IP-43, IK09, double door (Metallic) type. Make:- Hager/IndoAsian/Siemens. Note:-For Item No. 42 to 44 MCB are measured and paid separately under respective items.
S&F MCB SP 5 to 30 Amp 240 volts 'B' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB SP 5 to 30 Amp 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB SPN 20 to 40 Amp 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB TPN 40 to 63 Amp, 440 volt 'C' series, 16 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC. Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed by Engineer-in-Charge. Note :- Rate of excavation and returning fillig, GI wire 4 mm dia upto test point is to be considered in quoted rate by the contractor.
S&F in replacement of tube light fitting LED 20 Watt, 6000K, 230 Volt, LED batten complete with high brightness LED tube rod in opal finish and connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge. Make : Surya/Orient/Luker.
M/s Hansraj Shivhare
HARNAM SINGH ANIL SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .