Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.9 L+₹4.4 L (30.3%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹20.5 L
EMD Value
₹38,300
Closing Date
21 May 2020, 5:00 pmClosed
Executive Engineer Electrical Division No-1 HPPWD
Executive Engineer Electrical Division No-1 HPPWD Shimla-9
1. CO Indoor Auditorium for Cultural programmes at Solan Distt Solan Prov. Addressable Fire Alarm system and PA system therein.
2020_PWD_36724_1
Electrical Div No.I 06.11 Dated 21.04.2020
Open Tender
Electrical Works
Item Rate
365 days
SHIMLA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
E.E.Electrical Division No-I Shimla
₹38,300
3 Jun 2021
29 Apr 2020
22 May 2020
29 Apr 2020
21 May 2020
29 Apr 2020
Amount
Supply, installation, testing & commissioning of 2 Loop Fire Alarm control panel with base with specifications as follow.Network as 16 loops, fault tolerant redundantring network for high reliability; 40 or 80 zone alarm LED; Easy 4key press set-up; large LCD display; Supports the USB PC upload/download lead; Mobil phone style keypad and navigation keys;option to upload a company logo; Display 6x40 character (240x64 pixels)liquid crystal display with backlight illumination; control keys Evacuate, silience/Resound, Mute buzzer,Extend Delay, systemReset, show Alarm zones, Pc configuration software; 80 fire zones;7 day timers Event logging; On board diagnostics; Class change function;Coincidence and verification detection for false alarm management;Sensitivity adjustment e.g between day and night;input/output logic;2 indeprndent sounder circuits ;500mA universal Loop Driver;2xon board mounitored input;otput Relayds; Fire relay single pole changeover;Rs232 third party protocol interface; IP 30 EN6059. Make:- Edwards/Siemens/Notifire.
Supply, Installation, Testing & Commissioning of Analog Addressable type Photo Electric Smoke detector with standard mounting base, LED, Address Switch, complete with MS Powder coated Junction Box for mouting on Surface / on False Ceiling / Below False Floor, Cable lugs at Ends, cable compression glands, cable tags and Ferruling.. Make:- Notifire/Bosch /Siemens
supply,Installation. Testing & commissioning of Heat detector with base for store room &siting area with specificationsas follow:58&78 fixed temperature and rate of rise heat detectors; threshold of each detector to the specific risks found in the application; available with or without singlepole short circuit isolation with status control; tri colour LED offering red,green and amber colour to compliment modran building; 100% mechanical and electrical backwards compatibility; oprating volage Range 215 t0 32 Vdc; Maximum standby current 200uA at 240 VDC; islation current 15mA at 24VDc ; Maximum cintinuous current 1A (switch closed) ; 58 degree centigradeand rate of rise HTEI class BS- 68 degree centigrade fixed temperature. Make:- Notifire/Bosch /Siemens .
supply,Installation,Testing & commissioning of Manul Call Point-Pull Station with base for in side Auditorium and entry/exist point with specifications as follow; Unique Plug & play installation concept; Total Flex ability in the choice of opreating elemen; Anti-Tamper facility; Enhanced aesthetics and compact design; Fully approved to the latest standards; backward compatibility; CPD Approved; Cable termination0.5-2.5mm^2.Make:- Notifire/ Edwards/Siemens
Supply ,Installation ,Testing & commissioning of Control Module with Address Swich and all mounting accessories,complete with MS Power Coated Junction Box foe mounting on Surface,Cable lugs at Ends,cable compression glands,cable tags and Ferruling.Make:- Notifire/Edwards/Siemen.
supply, Installation,Testing & commissioning of Fault Isolater Module, ,complete with MS Powered coated junction Box for mounting on surface/on False Celling/Below False Floor,cable luges at Ends, Cable compression glands,cable tags and Ferruling.Make:- Edwards/ Notifire /SIEMENS .
Supply,Installation,Testing & commissioning of Ceiling Speakers with specifications as follow: 6W Box Speaker with Freq. Response of(120-16000Hz), sensitivity-96db, Speakers with inbuilt 100V line Matching Transformer and spring clamp mechanism for easy speaker mounting Power Tapes @100V 6w.3W,1.5W 70.75W Make:- Notifire/Bosch/Siemen.
Supply, Installation,Testing & commissioning of VAS call station with specifications as follow; works with (paging controller) for emergency notification and remout paging applications; Features include capability of extension of up to 16 MIC and 300 paging zones working with 10- zone paging controller, Mute function and built in chime, LED display with 1 MIC and volume control ,single zone ten zones grouping of zone, 1Line output, 1Line input.Make:- Bosch/ Notifire /Dynamic.
Supply ,Installation, testing & commissioning of 120 watt professional mixing amplifier with specification as follow; Freq. response of 60 Hz to 18 kHz distortion < 5% at rated output power, treble/bass of +/-8db;master line output of 1v loudspeaker direct output of 100V,8/4 ohm,input voltage 230VAC +/- 10-% at 50/60Hz or 24VDC; Inrush Current of 16A at 230 VAc,12A at 24VDC.Make:- Notifire/ Bosch/Siemens.
Supply, Installation, Testing & commissioning of Freestanding Gooseneck Microphone with Specfication as follow; multi Pattern condenser Mike, Mike on/off switch, Mike status LED, 5 inch Gooesneck. Make:- Shure/Ahuia/Dynamic/Bosch
SITC of Plena VAS Controller with built-in 240 W amplifier,12 business and emergency control inputs and supporting 6 zones ,extendable upto 60 zones, with single or dual channel operation, with loudspeaker line supervision. With Following Features: 1.Voltage 230VAC, 50/60 Hz 2.Max power consumption 600 VA 3.Battery power supply Voltage 24 VDC, +15% / -15% 4.Output power (rms/maximum) 240 W / 360 W 5.Frequency response 60 Hz to 18 kHz 6.Distortion <1% at rated output power, 1 kHz 7.Programmable Trigger Inputs 12 8.Speech filter -3 dB at 315 Hz, high-pass,6 dB/oct 9.Messages Data format WAV-file, 16-bit PCM, mono 10.Memory capacity 16 MB Flash ROM
Supply & Installation of Equipment Rack, 15U Made of MS for housing of all above equipment , front lockable glass door, Fan tray for cooling, Caster wheel base , Main Panel with Spike Buster, Individual FUSE power supply unit, including all internal wiring/ interconnection as required.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.4x1.5 Sq. mm.
Supply and drawing following size of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as requried 25mm.dia.
TARUN FIRE SYSTEM
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .