Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹3.6 L+₹50,750.56 (16.5%)Accepted-Finance | L2 | Accepted-Finance ok | |
| 3 | L3₹3.7 L+₹60,093.60 (19.5%)Accepted-Finance 4314 FIRST FLOOR KIKAR BAZAR BATHINDA 151 001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Accepted-Finance ok | |
| 4 | L4₹3.9 L+₹82,840.80 (26.9%)Accepted-Finance | L4 | Accepted-Finance ok | |
| 5 | L5₹4.1 L+₹97,730.08 (31.7%)Accepted-Finance | L5 | Accepted-Finance ok |
Tender Value
Refer Docs
Closing Date
12 Mar 2021, 11:15 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (EnM) WnS (WEST)
C-2A Block Janakpuri BPS New Delhi-110058.
Augmentation of suction and delivery line of sewage pumps-sets with other allied works at Khayala road SPS in AC-27 (Re-Invited).
2021_DJB_201041_1
e-NIT No.26 / EnM (WEST)/ 2020-21
Open Tender
Miscellaneous Works
Works
30 days
C-2A Block Janakpuri BPS New Delhi
Please refer Tender Documents.
3 documents required · 3 mandatory
₹500
Yes
DJB Account No. 50448339804
Exempted
20 Mar 2021
5 Mar 2021
12 Mar 2021
5 Mar 2021
12 Mar 2021
5 Mar 2021
120 days
Augmentation of suction and delivery line sewage pumps-sets with other allied works at Khayala road SPS by carrying out of following works. Disconnection of electric supply from panel of sewage submersible pump-sets/motors and Dismantling of existing old Pump-sets from the M.S base frame and valves, Bends, pipes etc. of both side (suction & delivery side) from pump-sets/Sewage submersible Pump-set with all accessories by doing all such work as per site requirement& taking out all the equipment from the base frame/foundation. The job also includes Removing of rusted base frame from the RCC foundation by cutting with gas cutter etc., breaking of foundation of horizontal p/sets by taking all precautions as per site requirement.
Taking out the sewage submersible pump-sets from sump well at ground level with the help of crane and dismantling the submersible pump/motor pump from pipes etc. after cutting/removing of all the rusted M.S. nut bolts by gas cutter, electric welding set, manual labour as per site requirement.
Cleaning of silt/garbage from sewage pump-sets as well as pumps & sump well in proper manner with the help of sewage gang beldar as per site requirement. The job also includes Cleaning of garbage and Breaking of existing damaged floor and removing the dust, soil etc. Providing and fixing at or suction line level precast Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, Plastering of floor as per site requirement and direction of Engineer-in-charge.
Making of working platform of sewage pump-set at the bottom site in the wet sump and providing/fixing of MS jalli of sump-well with provision to open the gate during maintenance work and delivery line system as per site requirement.
Supply of neoprene rubber packing sheet.
S/O Nut Bolt & Washers of suitable size of good quality as per site requirement.
S/O MS Pipe Confirming to IS:1239 Part-I, Medium class 100 mm diameter. Make: Jindal/ Tata.
S/O MS Pipe Confirming to IS:1239 Part-I, Medium class 125 mm diameter. Make: Jindal/ Tata.
S/O MS Pipe for main sewage delivery line Confirming to IS:1239 Part-I, Medium class 200 mm diameter. Make: Jindal/ Tata.
S/O of 100 mm dia. PN 1.0 Sluice Valve Make : KBL/IVC
S/O of 125 mm dia. PN 1.0 Sluice Valve for sewage submersible Pump-set. Make : KBL/IVC
S/O of 200 mm dia. PN 1.0 Sluice Valve Make: KBL/IVC
S/O of 125 mm dia. PN 1.0 Non-Return Valve. Make: KBL/IVC
Supply of MS Bend heavy duty of size 100 mm dia. 90*with double flange.
Supply of MS Bend heavy duty of size 125 mm dia. 90*with double flange.
S/O of 100 mm dia M.S. Flange.
S/O of 125 mm dia M.S. Flange
S/O of 200 mm dia M.S. Flange
Re-casting/strengthening of RCC foundation, plastering and making wet layer of cement of the foundation i/c. Shuttering etc. as required. Making / fabrication and supply of MS base frame/angle suitable for mono-block pump set. Grouting the foundation nut-bolts, Drilling/ machining and painting as per site requirement or direction of engineer-in-charge (as per sample)
Loading, Unloading, Cartage and Transportation charges for taking all dismantled equipment from site to store and new equipment at site including charges of heavy labour etc. as per requirement.
Installation/Fitting, testing and coming of Pump-sets on the Base-Frame/Foundation. The job also includes installation & fixing of Valves, pipes, Bends, Reducers, Flanges etc. of both side (suction & delivery side) of all pump-sets including primer & paint on complete equipment as per the site requirement and lowering of sewage submersible pump-set with the help of crane & proper-alignment of pump-sets after taking all safety precaution arrangements, all Tools & Tackles etc including painting of all E&M equipments. The work shall be completed on turn-key basis and job also includes testing of Pump-sets on full load condition as per direction of engineer-in-charge.
M/S BRIJ BHUSHAN SHARMA
SANJAY SALES CORPORATION
Raj Engineering Co.
J.S Industrial work
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .