| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹27.5 L+₹4.9 L (21.4%)Rejected-AOC WZ 1043 C IIND FLOOR NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-AOC other than lowest | |
| 3 | L3₹27.8 L+₹5.2 L (22.8%)Rejected-AOC | L3 | Rejected-AOC other than lowest | |
| 4 | L4₹27.9 L+₹5.3 L (23.2%)Rejected-AOC FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L4 | Rejected-AOC other than lowest | |
| 5 | L5₹29.8 L+₹7.2 L (31.6%)Rejected-AOC | L5 | Rejected-AOC other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Aug 2020, 6:00 pmClosed
GE (N) Delhi Cantt-10
GE (N) Delhi Cantt-10
REPAIRS TO TOILET LEEKAGE SEEPAGE PLUMBING AND OTHER MISC B R ITEMS INCL INT ELECT TO OFFRS MD ACCN AND OTM ACCN IN THE AOR OF AGE B R I UNDER GE NORTH DELHI CANTT
2020_MES_362395_1
GE/NORTH-30/2020-21
Open Tender
Civil Works
Works
180 days
GE (N) Delhi Cantt-10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) Delhi Cantt-10
₹90,000
Yes
8 Sept 2020
20 Jul 2020
18 Aug 2020
20 Jul 2020
17 Aug 2020
3 Aug 2020
Amount
Demolition of cement concrete (unreinforced) above GL in roof etc. n.exc 15 cm thickness complete all as specified.
Demolition of reinforced cement concrete in roof floor (other than ground floors) beams staircase, landing chajja and similar work complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for Reinforced cement concrete 1:2:4 type B-1 ( using 20 mm graded cdrushed stone aggregate) as in chajjas and the like, all as specified and directed by Engr-in-Charge.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping, fair finished surface of concrete, all as specified .
M&L for TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
M&L for TMT bars 6mm to 8mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
M&L plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in levelling /sloping course finished even and fair complete all as specified.
Taking down cement plaster of any description from brick stone walls or concrete surface including racking out joints, hacking for keys scrubbing down with water etc.M&L rendering 10 mm thick in cement mortar 1 : 6 mixed with PD proof 101 LW (or+) of fixit or equalant integral WP admixer @ 200 ml/bag of cement over two coats of super latex 302 of Dr fixit or equ.in the ratio 1:4:7 (one part super latex 302, 4 part water and 7 part cement ) @ 1.50 kg of homogenous mixture per sqm in two coats and finished the surface even and fair without using extra cement complete all as specified and directed.Note : - PD proof 101 LW (+) and super latex 302 shell be measured and paid seperatly.
Taking down cement plaster of any description from brick stone walls or concrete surface including racking out joints, hacking for keys scrubbing down with water etc.M&L rendering 15 mm thick in cement mortar 1 : 4 in layer (10 mm + 5 mm ) mixed with PD proof 101 LW (or+) of fixit or equalant integral WP admixer @ 200 ml/bag of cement over two coats of super latex 302 of Dr fixit or equ.in the ratio 1:4:7 (one part super latex 302, 4 part water and 7 part cement ) @ 1.50 kg of homogenious mixture per sqm in two coats and finished the surface even and fair without using extra cement complete all as specified and directed.Note : - PD proof 101 LW (+) and super latex 302 shell be measured and paid seperatly.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified.
M&L for Rendering 10+5 mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified. (Water proofing compound to be measured and paid for separately).
M&L for Rendering 10mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement all as specified.
M&L for Rendering 10mm thick on other than fair faces of brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement all as specified.
M&L for Rendering 10mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement all as specified.
Supply only liquid water proofing compound complete all as specified.
Supply only PD proof 101 LW (+) of Dr Fixit or eqe.
Supply only super latex 302 of Dr Fixit or eqe.
Demolition of brick/stone masonry built in CM. all as specified.
M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 all as specified.
M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 but except bricks all as specified.
M&L half brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:4 all as specified and directed.
M&LProviding cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0.
M&L Roughening surfaces of old concrete surfaces by picking sweeping, cleaning and washing down with water to remove dust etc complete all as specified.
M & L for Water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below and as directed by Engineer-in-Charge. (a) M&L for 15mm thick plaster screed bed layer in CM 1:3 on concrete surfaces. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.20 Kg/Sqm of area complete all as specified. (c) Laying APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 Kg/Sqm with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified & as directed by Engr in Charge
M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand blasting, scrubbing down conrete sufrace with wire brushes cleaning with water allowed to dry and applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited all as specified and applying two layess of guniting over steel welded mesh 2mm dia of wire and aperture 75mm,total thickness of gunite n.exc 25mm thick (average thickness) in cement mortar 1: 2 using OPC 53 grade cement mixed with polycrete admixture @ 2% by weight of cement or as per manufacturers instructions and finally applying cement plaster over gunited surface of required thickness to give even, uniform and smooth finish conforming to proper gerometrics in cement mortar ( 1 : 3) to match with the existing surface as in sides and soffits etc of slabs, chajjas, fins, facias, parapets , columns and beams etc complete including necessary scaffolding, shuttering, necessary chases to brick work or RCC members at any height upto 4 storey bldgs all as specified. (Note : Steel welded mesh is to be tightend / welded with the existing re-inforcement. The cost of welded mesh is deemed to be included in the unit rate quoted by the contractor).
M&L for preparing newly plastered surfaces of ceilling and applying two coats of white wash complete all as specified.
M&L for preparation of old decorated plastered or unplastered surfaces wall by brooming down scrapping down smoke and efflorescent salts etc and applying two coat of white wash on walls complete all as specified and directed.
M&L preparation of newly plastered surface on walls and applying 2 coat of OBD over a coat of chalk whiting complete all as specified.
M&L two coats of cement cement base paint on walls including preparation on new/ old surfaces complete all as specified and directed. .
Dismantling water tank exceeding 250 ltr but not exceeding 500 ltr capacity complete all as directed and specified.
Dismantling water tank exceeding 500 ltr but not exceeding 1000 ltr capacity complete all as directed and specified.
S&F rotational moulded polythene water storage tanks, multi-layered, 500 Ltr capacity, cylindrical, vertical with closed top, hoisted and fixed in position complete all as specified and directed.
S&F rotational moulded polythene water storage tanks, multi-layered, 1000 Ltr capacity, cylindrical, vertical with closed top, hoisted and fixed in position complete all as specified and directed.
S & F ISI Marked 20mm bore PTMT high pressure rate float valve with aluminium rod and ball screwed for iron pipe complete all as specified and directed.
Disconnecting existing overhead tanks,setting aside or lowered if required for repairing ,cleaning etc and hoisting if reqd reconnecting and refixing in position but capacity exceeding 250 litres and not exc 500 litres complete all as specified & directed.
Disconnecting existing overhead tanks,setting aside or lowered if required for repairing ,cleaning etc and hoisting if reqd reconnecting and refixing in position but capacity exceeding 500 litres and not exc 1000 litres complete all as specified & directed.
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc capacity exceeding 250 litres and not exc 500 litres complete all as specified & directed.
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc capacity exceeding 500 litres and not exc 1000 litres complete all as specified & directed.
S&F in repair ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (min wt 142 gm each) for 20 mm bore of pipe.
S & F in repair 15 mm bore dia Gun metal gate valve with iron wheel head screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S & F in repair 20mm bore dia Gun metal gate valve with iron wheel head screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Taking up or down steel water tubing and connections 20mm bore pipe complete all as specified and directed.
M&L 20mm bore GI tubing medium grade with all fittings and fixed complete to walls, ceiling or laid in floor complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position ( wall/floor/ceilings etc ) of size 20 mm bore
Taking up or down steel water tubing and connections 15mm bore pipe complete all as specified and directed.
M&L 15mm bore GI tubing medium grade with all fittings and fixed complete to walls, ceiling or laid in floor complete all as specified and directed.
Refixing of old steel tubing and connections in new or old position ( wall/floor/ceilings etc ) of size 15 mm bore
Taking down of eaves gutters and rainwater pipes (any size or any pattern),including all fittings etc. all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length including mild steel stack clamps fixed in cement concrete 1:2:4 blocks with rubber ring joints fixed to walls complete all as specified and directed.
Supply only 110mm bore PVC (SWR) bends with rubber ring joints fixed to walls complete all as specified and directed.
M&L non skid ceramic tiles colored tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,in floor etc set and jointed in neat cement slurry and pointed in colour cement laid over and including 15mm thick cement mortar screed bed in CM (1:6) complete all as specified and directed.
M&L for Vitrified Ceramic coloured dark shade tiles 10 mm thick (square/rectengular) polished, area of each tile n. exc 0.36 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface insluding 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for glazed coloured ceramic tiles in dado/vertical surface (350mm x250mm x 7 mm/450x350x7mm) thick set and jointed in neat cement slurry and pointed in coloured cement to match the surface including 10 mm thick in cement mortar 1:4 even and fair for receving tiles on vertical surface complete all as specified and directed by Engr-in-Charge.
All as per item No 53 but on vertical surface as in skirting ,including 10 mm thick rendering in CM 1:3 even on fair faces of brick work complete all as specified and directed by Engr-in-Charge.
S&F in rep stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 20 mm bore complete all as specified.
S&F in repair water closet squatting pan ``Orissa pattern`` 580 mmx440 mm, white with integral foot rests including fixing charges of flushing cistern, connection to trap, anti syphonage pipe and provn of lime concrete etc complete all as specified.
S&F in repairs vitreous China wash basin, white, flat back, size 550x400mm including tap, chain, plug brackets, waste fitting 32mm dia ,brass chromimium plated for glazed ware sink, basin,with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed complete all as specified.
Supply only PVC low level flushing cistern 10 ltrs capacity incl PVC float valves, PVC connection and out let pipes complete all as specified and directed.
S&F in repair Bib cock with long thread, chromium plated , with long body, wall flange screwed for iron pipe or for brass ferrule and fixed to 15mm bore pipe complete all as specified.
S&F in reapir angular stop valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm dia pipe, all as specified. ISI marked.
S&F in rep Bib tap cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe of size 15mm bore chromium plated. all as specified
S&F in repairs Chromium plate tubular towel rail, 20mm dia, D type, 60cm long between flanges . all as specified.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm.
M&L Indian type WC/EWC including demolittion of cement concrete (unreinforced) in sunken portion of WC, area n.exc 1.50 sqm including removing of unserviceable materials incl rendering 10 mm thick plaster in cement mortar ( 1:4 ) with WPC and laying lean concrete in bottom portion of WC and then applying 3mm thick APP membrane over bitumen primer surface of walls and bottom portion of WC with torch method , provide 32 mm dia GI tubing as spout of sunken portion 0.60 m long of approved quality , By filling Khanger / cinder and lean concrete, supply and fix vitreous china Squatting pan "Orissa pattern" size 580x440mm white, with integral foot rest & ' P' traps & jointing new 100 mm dia CI pipe with lead joints to WC ( excluding flushing cistern & flush pipe ) . Testing of sunken portion will be carried out by filling water for 24 Hrs in sunken area complete in all respect as specified and directed .
S&F in repair for Gypsum ceiling board for ceiling prepainted, perforated finish, 600 x 600 x 9 to 9.5mm thick in size, of approved brand/make, laid over and including grid work of size 600 x 600mm, made out of 0.5mm thick G.I. tee 32 x 24 mm for main, 25x24mm for cross tee and 20 x 20mm angle fixed on wall, powder coated finish on exposed faces of tee and angle. hung from ceiling using 2 mm thick G.I. Suspension wires spaced at 1200 mm on main runners including making niches for fans/light at as specified and directed.
S&Fin repairsCP mixer pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, mixing 'Hot' or 'Cold' water with long screwed shanks and fly nuts, screwed for iron pipe and fixed of bore dia 15mm.
S&F in repair elegent mirror PVC cabinet with towel rail of size 450x600x150 mm all as specified (Make : prayag Cat No. 551 or equivalent of ZIM/ JAQUAR )
S & F Glass Shelf Corner trangular type shelf 250 mm radius with guard bars with CP brackets fancy type 5mm thick glass Make : prayag/Zim
S&F in repair Vitreous china wash down water closet pan (pedestal pattern), white including fixing bolts, flushing cistern and flush pipe connection to trap and to flushing pipe including provn of cement concrete beading complete all as specified and directed.
Supply only EWC Seat cover black colour of PVC complete all as specified and directed.
S&F in repairs shower rose fancy type bass chromium plated 125 mm heavy duty pattern with swivel joints type screwed for 15mm bore including jointing to pipe or unions complete all as specifed and directed.
S&F in repair CP hand spray (health facucet with 1.0 M long easy flex tube in chrome finish and wall hook) complete all as specified and directed. Make : PRAYAG/CERA
S&F in repair 2 in 1 Angle Valve 15 mm CP fancy pattern type cast copper alloy screwed for iron pipe or forbrass ferrule and fixed all as specified and as directed Make ZIM/SIKKO/PRAYAG.
S&F in rep chromium plated jet for WC with 1.00 M long PVC pipe including necessary fittings complete all as specified and directed.
M&L for removal of plant growth by injection with chemical glyphosphate solution (4% concentration) @ 20ml or till refuse by cutting or injection in stem of plants or roots at 30mm. The area shall then be sprayed with solution 25ml glyphosphate (4% concentration) diluted with 1ltr of water.The size of block considred as whole bldg. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base paint or acrylic paint all as specified and directed.
Dismantling cast iron pipe pipes, jointed in cement mortar of any dia upto 100mm. all as specified.
S&F cast iron soil, waste and vent pipes (sand cast) 100mm bore in any length with or without ears with cement joints fixed to walls duly apply a coat of bitumenous black paint complete all as specified and directed.
S&F cast iron soil, waste and vent pipes (sand cast) 75mm bore in any length with or without ears with cement joints fixed to walls duly apply a coat of bitumenous black paint complete all as specified and directed.
S&F in rep Cast iron bend (any radius) diminishing pieces or tapers 100mm bore fitted with oval access door. all as specified.
S&Fin rep Cast iron bend (any radius) diminishing pieces or tapers 75mm bore fitted with oval access door.
S&F in repairs 32/40mm dia PVC waste pipe for WHB & sink with union complete all as specified.
E/M Portion Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point controlled by one, one way switch 06 Amps.
All as per srl item No 85 here-in-before but one fan point controlled by one, one way switch 06 Amps
All as per srl item No 85 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch
All as per srl item No 85 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch
All as per Serial Item No 85 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F modular switch, 06 Amps, single pole, one way, 250 volts, one module and IP 20 protection complete (Make : Anchor/Havells/Legrand)
S&F modular bell push with indicator, 06 Amps, single pole, one way, 250 volts complete (Make : Anchor/Havells/Legrand)
S&F modular switch, with indicator, 16 Amps, single pole, one way, 250 volts, one module complete (Make : Anchor/Havells/Legrand)
S&F modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete (Make : Anchor/Havells/Legrand)
S&F modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete (Make : Anchor/Havells/Legrand)
S&F ding dong bell, AC, 230 volts, single pole complete (Make : SSK/Havells/Anchor)
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts complete (Make: - Anchor/Havells/Legrand)
S&F ceiling rose, 6 Amps, 250 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete (Make : SSK/Havells/Anchor)
S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 7W LED bulb complete (Make of Bulb : Wipro/Havells/Philips) (Make of fitting: SSK/Havells/Anchor)
S&F in repair decorative wall mounting, S.S finish fixture with opal PC diffuser suitable for 10/12 watt LED Lamp, lamp holder, including 12 Watts LED bulb of 6500 K of B22 base cap (Make of Bulb : Havells/Philips/ Wipro), and all accessories pre-wired including connecting up complete (Make Havells/ Philips)
S&F in repair surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete (Make : Havells / Philips/ Wipro)
S&F in repair on surface and wall mounted LED batten with polycarbonate housing and initigarated electronic drive 18/20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete (Make : Havells/Philips/Wipro)
S&F in repair energy saving security light fitting of 45 watts LED Versatile pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete (Make : Havells / Philips/Wipro)
S&F Ventilating fan wall mounted type of 250 mm sweep, 240 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete (Make : Havells/Usha / Crompton Greaves)
M&L for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing including taking down old sub main wiring complete
M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete
S&F in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete (Make: - Legrand/Havells/Hager/Schneider)
S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete (Make :- Legrand/Havells/Hager/Schneider)
S&F in repair MCB, SP, AC, 240 volts of 06 to 32 Amps capacity "C" curve, 10 KA and making connections by using suitable copper lugs complete (Make :- Legrand/Havells/Hager/Schneider)
S&F in repair MCB, DP, AC, 240 volts of 32 Amps capacity "C" curve, 10 KA and making connections by using suitable copper lugs complete (Make :- Legrand/Havells/Hager/Schneider)
S&F in repair MCB, DP, AC, 240 volts of 63 Amps capacity "C" curve, 10 KA and making connections by using suitable copper lugs complete (Make :- Legrand/Havells/Hager/Schneider)
S&F in repair MCCB, 100 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity and connection complete all as specified & directed (Make :- Legrand/Havells/Hager/Schneider)
S&F in repair MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity and connection complete (Make :- Legrand/Havells/Hager/Schneider)
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - Rs.67098.00
M/S AADI ENTERPRISES
M/S SURINDERAS CONSTRUCTION CO.
The new hut furnitures
AAYUSHI ENTERPRISES
Adhunik Builders
ASHISH GARG AND COMPANY
imran construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .