EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B AND R BR JALANDHAR CANTT
CONSTRUCTION OF PHC 24X7 AT DAROLI KALAN IN DISTT. JALANDHAR
2025_CEPW_154580_1
Re-Bid No 19 of 26/11/2025
Open Tender
Civil Works - Buildings
Percentage
180 days
Jalandhar
Please refer Tender documents.
13 documents required · 13 mandatory
₹10,000
₹4.1 L
26 Nov 2025
26 Nov 2025
11 Dec 2025
26 Nov 2025
10 Dec 2025
26 Nov 2025
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority :- EXECUTIVE ENGINEER PROVINCIAL DIVISION PWD B&R JALANDHAR
Name of Work :- DNIT FOR CONSTRUCTION OF PHC 24X7 AT DAROLI KALAN IN DISTRICT JALANDHAR
Contract No: Civil Works
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Work Name Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1 i) CIVIL WORK 2
2 Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. 3 593.03 Cum 35.82 Excess(+) Full Conversion INR
3 Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. 4 499.12 Litre 391.9 Excess(+) Full Conversion INR
4 Cement concrete 1:8:16 With stone aggregates 40mm gauge by mechanical means using concrete mixer volumetric type 5 115.64 Cum 3664.59 Excess(+) Full Conversion INR
5 Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth 6 141.78 Cum 5789.04 Excess(+) Full Conversion INR
6 Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. 7 215.4 Cum 6578.11 Excess(+) Full Conversion INR
7 Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 9 432 Qtl. 7876.91 Excess(+) Full Conversion INR
8 Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering ) 10 185.05 Sqm 221.24 Excess(+) Full Conversion INR
9 Centering and shuttering for columns (Square or ractangular or poly gonal in plain) 11 561.92 Sqm 502.52 Excess(+) Full Conversion INR
10 Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. 12 525.76 Sqm 400.33 Excess(+) Full Conversion INR
11 Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 13 807.38 Sqm 560.46 Excess(+) Full Conversion INR
12 First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth 14 77.26 Cum 6135.24 Excess(+) Full Conversion INR
13 First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level 15 244.93 Cum 6279.57 Excess(+) Full Conversion INR
14 115 mm thick brick wall laid in cement mortor 1:4 without reinforcement in super structure. 16 94.83 Sqm 781.83 Excess(+) Full Conversion INR
15 12.5 mm thick cement plaster 1:5 17 1396.37 Sqm 194.82 Excess(+) Full Conversion INR
16 12.5mm th C plaster in CM 1:4 18 Sqm 203.35 Excess(+) Full Conversion INR
17 20mm thick cement plaster 1:5 in two coat work 19 311.11 Sqm 266.43 Excess(+) Full Conversion INR
18 20mm thick cement plaster 1:4 in two coat work 20 311.11 Sqm 280.13 Excess(+) Full Conversion INR
19 Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing 21 753.47 Sqm 776.27 Excess(+) Full Conversion INR
20 Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified 22 121.95 Rmt 70.47 Excess(+) Full Conversion INR
21 Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 23 18 Each 105.64 Excess(+) Full Conversion INR
22 Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item) 24 82.32 Rmt 244.41 Excess(+) Full Conversion INR
23 Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. 25 36 Each 142.22 Excess(+) Full Conversion INR
24 Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge 26 36 Each 88.49 Excess(+) Full Conversion INR
25 Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 27 18 Each 814.29 Excess(+) Full Conversion INR
26 Earth filling under floors with surplus ordinary soil or soil containing gravel or premises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres 28 431.91 Cum 429.6 Excess(+) Full Conversion INR
27 Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres 29 237.21 Cum 66.37 Excess(+) Full Conversion INR
28 Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material 30 553.13 Sqm 487.48 Excess(+) Full Conversion INR
29 Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 31 613.11 Sqm 1159.83 Excess(+) Full Conversion INR
30 Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : 32 32.89 Sqm 1566.21 Excess(+) Full Conversion INR
31 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Non traffic Areas and streets having width less than 3.05 mt.( Also not to used over footoaths). 33 404.12 Sqm 694.45 Excess(+) Full Conversion INR
32 Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete 34
33 b) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.38 kg per meter. 35 526.22 Rmt 527.52 Excess(+) Full Conversion INR
34 c) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. 36 1182.26 Rmt 603.98 Excess(+) Full Conversion INR
35 Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) 37 1174.05 Kg 145.99 Excess(+) Full Conversion INR
36 Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect 38 286.35 Rmt 59 Excess(+) Full Conversion INR
37 Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position 39 24.29 Qtl. 10798.95 Excess(+) Full Conversion INR
38 Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm thick above 0.40 sqm area. 40 96.95 Sqm 629.99 Excess(+) Full Conversion INR
39 Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects 41 48.48 Sqm 954.47 Excess(+) Full Conversion INR
40 Factory manufactured solid flush door fixed in position iron hinges, etc . (excluding the cost of any fittings other than specified above but including the labour for fxing the same in position a) comercial with elm or gujan facing on both/sides with laminated core and lipped edges. iv) 35mm thick. 42 98.3 Sqm 2430.42 Excess(+) Full Conversion INR
41 Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. 43 221.18 Sqm 45.3 Excess(+) Full Conversion INR
42 qtl 44 98.3 Sqm 116.94 Excess(+) Full Conversion INR
43 Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete 45 45 Each 209.65 Excess(+) Full Conversion INR
44 Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeI.S.I Designation No. II (size of door 701mm to 850mm) 46 12 Each 1210.47 Excess(+) Full Conversion INR
45 Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect \ 47 45 Rft 506.73 Excess(+) Full Conversion INR
46 Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish 48 3414.94 Sqm 84.28 Excess(+) Full Conversion INR
47 Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade 49 2793.73 Sqm 79.01 Excess(+) Full Conversion INR
48 Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) 50 353.66 Sqm 93.76 Excess(+) Full Conversion INR
49 Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm 51 622.21 Sqm 126.42 Excess(+) Full Conversion INR
50 Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade 52 2989.84 Sqm 69.53 Excess(+) Full Conversion INR
51 Providing and fixing polycarbonate sheet sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws with EPDM seal, and the joints shall be provided with aluminium strips at top and bottom as a seal complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Pollycarbonate sheet 2mm thick solid type 53 91.97 Sqm 1672.96 Excess(+) Full Conversion INR
52 Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black itumastic paint conforming to I.S.I complete as per standard design. 54 141.45 Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. 718.49 Excess(+) Full Conversion INR
53 Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm 55 176.53 Sqm 46.35 Excess(+) Full Conversion INR
54 Providing and fixing in position C.P. Acryli shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-incharge ) fixed in with rawl plugs and C.P brass screws complete in all respect. 56 17.75 Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. 305.52 Excess(+) Full Conversion INR
55 Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. uPVC Pipe 10 Kgf/cm2 25mm i/d 57 24.32 Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. 2321.91 Excess(+) Full Conversion INR
56 Development and stabilizing of the Tubewell with Air Compressor and submersible pumping set of required capacity as directed by the Engineer-in-charge including the cost of tools and appliances and consumable to the satisfaction of Engineer-in-charge. 58 176.53 Sqm 60.05 Excess(+) Full Conversion INR
57 Credit of Old Material 59 15 Each 234.93 Excess(+) Full Conversion INR
58 Disposal of malba including loading and unloading 60 17 Each 149.6 Excess(+) Full Conversion INR
59 Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). RCC Man hole cover with Frame 560mm i/d RCC man hole cover with frame as per ISI 61 50.8 Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. 226.12 Excess(+) Full Conversion INR
60 Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm 62
61 Dismantling brick work tile, masonry or tile lining (b) In cement 63 40739 Each 4.21 Excess(+) Full Conversion INR
62 Stripping and stacking slate or tiles of a roof. 64 3919.04 Each 6.32 Excess(+) Full Conversion INR
63 cum 65 56.58 Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. 497.78 Excess(+) Full Conversion INR
64 Removing earth from top of roof 66 1094.28 Kg 30 Excess(+) Full Conversion INR
65 Dismantling of RCC slab 67 15 Each 500 Excess(+) Full Conversion INR
66 Dismantling of CC flooring 68 17 Each 500 Excess(+) Full Conversion INR
67 ii) ELECTRICAL WORKS 69
68 D1- E.I Work 70
69 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 71
70 Wiring fan point (With fan box) 72 47 Each 1210.21 Excess(+) Full Conversion INR
71 Wiring light point 73 149 Each 762.47 Excess(+) Full Conversion INR
72 Wiring call-bell point 74 5 Each 744.03 Excess(+) Full Conversion INR
73 Wiring 6 Amp. wall socket point 75 22 Each 618.93125 Excess(+) Full Conversion INR
74 Wiring 6 Amp. Plug control comprising wall socket point 76 46 Each 371.35875 Excess(+) Full Conversion INR
75 Wiring 16/20 amp. power plug control point 77 30 Each 478.03 Excess(+) Full Conversion INR
76 Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 78
77 Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). 79 14 Each 707.95 Excess(+) Full Conversion INR
78 Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- 80
79 Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. 81 11 Each 826.79 Excess(+) Full Conversion INR
80 RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- 82
81 Wiring Telephone socket point RJ11 (one module) 83 2 Each 355.24 Excess(+) Full Conversion INR
82 Wiring Networking socket point RJ45 (one module) 84 14 Each 461.43 Excess(+) Full Conversion INR
83 PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 85
84 Overall size 1.5sq.mm (Un-sheathed) 86 1500 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 30.34 Excess(+) Full Conversion INR
85 Overall size 2.5sq.mm (Un-sheathed) 87 1250 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 45.51 Excess(+) Full Conversion INR
86 Overall size 4sq.mm (Un-sheathed) 88 660 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 65.74 Excess(+) Full Conversion INR
87 Overall size 6sq.mm (Un-sheathed) 89 550 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 91.02 Excess(+) Full Conversion INR
88 Overall size 10sq.mm (Un-sheathed) 90 550 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 176.15 Excess(+) Full Conversion INR
89 COPPER CONDUCTOR CABLE FOR SPECIAL ELECTRICAL SERVICES: Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulated with star separator, 4 pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 1 91
90 80 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E Standard left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge. 92 550 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 45.3 Excess(+) Full Conversion INR
91 CAT 6 LAN cable 93
92 XLPE INSULATED ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- 94 70 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 210.17 Excess(+) Full Conversion INR
93 Overall size 10sq.mm (2Core) Armoured (On-Surface) 95
94 HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- 96 47 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 131.69 Excess(+) Full Conversion INR
95 Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. 97
96 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- 98 550 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 70.8 Excess(+) Full Conversion INR
97 Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed 99 320 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 97.34 Excess(+) Full Conversion INR
98 Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed 100
99 Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- 101 100 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 17.91 Excess(+) Full Conversion INR
100 PVC flexible pipe 25mm dia. 102 80 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 27.39 Excess(+) Full Conversion INR
101 PVC flexible pipe 32mm dia. 103
102 G.I. EARTHING :- Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). 104 6 Each 3315.89 Excess(+) Full Conversion INR
103 Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) 105
104 SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- 106 14 Each 179.31 Excess(+) Full Conversion INR
105 Modular RJ-45 Modem Jack for Computer (One Module) 107
106 MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- 108 66 Each 211.75 Excess(+) Full Conversion INR
107 MCB Single Pole 6-32amp. (10kA, Curve-C) 109 10 Each 877.04 Excess(+) Full Conversion INR
108 MCB Double Pole 40amp. (10kA, Curve-C) 110 3 Each 1945.29 Excess(+) Full Conversion INR
109 MCB Four Pole 50, 63amp. (10kA, Curve-C) 111 8 Each 1472.79 Excess(+) Full Conversion INR
110 MCB Triple Pole 50, 63amp. (10kA, Curve-C) 112
111 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- 113 3 Each 1797.9 Excess(+) Full Conversion INR
112 SP&N Double Door Distribution Board 12 way each 114 3 Each 2914.92 Excess(+) Full Conversion INR
113 TP&N Horizontal Double Door Distribution Board 4 way each 115
114 COPPER EARTHING: 8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- 116 4 Each 8471.83 Excess(+) Full Conversion INR
115 Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long 117
116 XLPE INSULATED UN-ARMOURED CABLES (LOOSE): 118 100 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 575.21 Excess(+) Full Conversion INR
117 Overall size 70sq.mm (3½ Core) Un-armoured (Loose) 119
118 p) are included in the luminaire ordering part code, complete in all respects as desired by the Engineer in charge of work at site. 120
119 LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): 121
120 The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. 122
121 The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. 123
122 Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. 124
123 Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing 125 1 Each 74076.27 Excess(+) Full Conversion INR
124 of panel with complete specification from the Engineer in charge at site. Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:- 126
125 LT Panel enclosure having space for 1No. Incomer MCCB 200Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 1000 x 300mm) 127
126 MCCB's (FOR PANELS & SHEET ENCLOSURE): 128 1 Each 14980.77 Excess(+) Full Conversion INR
127 Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- 129 5 Each 8297.89 Excess(+) Full Conversion INR
128 MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 130
129 MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting 131
130 ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure): 132 1 Each 8321.39 Excess(+) Full Conversion INR
131 Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- 133
132 On Load Change Over Switch Four Pole 100amp., 415volts 134 1 Each 10403.37 Excess(+) Full Conversion INR
133 Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- 135
134 TP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB 160amp.) 136 100 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 199.11 Excess(+) Full Conversion INR
135 Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- 137 70 Supply & installation of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms, Audible Alarm etc. complete in all respects as desired by the Engineer in charge of work at site. 133.79 Excess(+) Full Conversion INR
136 Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) 138 47 Each 3520 Excess(+) Full Conversion INR
137 Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) 139 11 Each 4846 Excess(+) Full Conversion INR
138 Supply and Erection of 3 Star Rating Ceiling fan Suitable size 48” (1200mm) Full Aluminium Body, 3 Nos. of Blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delevery of 218 CMM. The rated speed of the product must be minimum of 350 revolutions per minute and 5 Nos. of speed. The approximate weight of the product should be 4kg and 180gms (without packing) or higher. The product should have a manufacturer's guarantee/ warranty of minimum 2 years. The product should be complete in all respects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fans having connection with PVC insulated PVC sheathed tow single core copper conductor (FR) cable 0.75 SQ MM. Complete in all respects as desired by the Engineer in charge of work at site. 140 8 Each 2690 Excess(+) Full Conversion INR
139 Supply and Erection of Heavy Duty Exhaust Fan Suitable size 12” (300mm) including Louver shutter, connection & testing complete in all respects as desired by the Engineer in charge of work at site. Trade Name : Exhaust Fan, Blade Sweep : 300 mm (12”), Type of motor : Permanent capacitor induction motor, C75 Rated Voltage : 230 volts, 50 Hz, AC. single Phase, Test voltage : 230 volts, 50 Hz, .AC. I Phase, Frequency : 50 Hz., Capacitor rating : 1.0 F, 400V, 50 Hz, AC., Rated watts at full (load) speed & at 230V. : 27 watts., Current in amps at full speed & at 230 V. : 0.12 Amps., Power factor : 0.9 min., Rated full speed & at 230 V : 1310 rpm., Rated air delivery at 230 V : 800 M3/hr, Rated Service value : 30 m3/hr/watt, No. of blades leaves : Five, Type of blade leaf : Plastic (PP), No of running positions : One position, Class of Insulation : Class “E”, Type of bearings : Oil impregnated self aligned bush bearings. 141 78 Each 785 Excess(+) Full Conversion INR
140 Supply and Erection of 36 Watt 2X2 Surface mounted panel (including constant LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. 142 49 Each 589 Excess(+) Full Conversion INR
141 Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. 143 8 Each 4629 Excess(+) Full Conversion INR
142 Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 144 3 Each 3384 Excess(+) Full Conversion INR
143 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. 145
144 Supply and erection of LED Flood Light 100watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK 07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. 146 1 Each 16736 Excess(+) Full Conversion INR
145 Supply and Erection of Wall fan plastic body 400mm 16" including flexiible wire and petty material etc. for connection and testing complete in all respects as desired by the Engineer in charge of work at site. 147 1 Each 8304 Excess(+) Full Conversion INR
146 D2- Networking System 148 13 Each 247 Excess(+) Full Conversion INR
147 Supply, Installation, Testing & Commissioning of 16-Port Gigabit Unmanaged Switch ,10/100/1000Mbps Gigibit Ethernet ,16 ,76W ,External Input 54V 3.7A(200W) Input 54V 2.4A(130W) Input 54V 1.66A(90W) ,Metal ,Desktop, wall & rack mount ,Power, Link/Activity ,Fanless ,Yes ,4K ,1MB ,32Gbps ,IEEE 802.3az complaint ,2,088,514 hours ,Yes ,Yes ,1:3:5:7:8:10:12:15 Weighted Fair Queue (WFQ) ,Input 54V 1.66A (90W) External ,90W ,0 dBA (Fanless) ,0° to 40°C (32° to 104°F) ,Class A ,11.26 x 4.02 x 1.06 in ,0.88 kg (1.94 lb) ,47 CFR FCC Part 15, SubpartB, Class A ICES-003:2016 Issue 6, Class A ANSI C63.4:2014 ,55032:2012+AC:2013, Class A EN 55024:2010 EN 61000-3-2:2014, Class A EN 61000-3-3:2013 ,AS/NZS CISPR 32:2015, Class A ,VCCI-CISPR 32:2016, Class A ,CNS 13438 ,CB. IEC 60950-1:2005(ed.2) + A1:2009 + A2:2013 ,UL/cUL Listed; UL60950-1, 2nd Ed. 2014; CAN/CSA C22.2 No. 60950-1-07, 2nd Ed. 2014 ,EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 ,AS/NZS 60950.1:2015 ,Lifetime Hardware Warranty ,90 Day's Free remote configuration support ,Replacement with new box product. complete in all respects as desired by the Engineer in charge of work at site. 149 13 Each 292 Excess(+) Full Conversion INR
148 SITC of CAT 6, 24 Port Fully loaded Patch Panel, Rack Mountable for cable termination complete in all respects as desired by the Engineer in charge of work at site. 150 1 Each 15754 Excess(+) Full Conversion INR
149 SITC of CAT 6 ONE Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps complete in all respects as desired by the Engineer in charge of work at site. 151 1 SITC of CAT 6 TWO Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps complete in all respects as desired by the Engineer in charge of work at site. 9471 Excess(+) Full Conversion INR
150 Supply & Erection of POE Powered Indoor Wi-Fi Access Point 1 Gbps Speed having 2.4Ghz and 5Ghz network, omni directional antenna, 01 No. Giga WAN port and, Password Protection, Wide Area Range, Ceiling /Wall Mount Flow Control, App Controlled, IEEE 802.3at PoE, Up to 100 Wi-Fi Users, Security Protocol WPA/WPA2/WPA3™ Personal/ Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control Power Supply Connect 12 V / 2.5 A (optional power adapter not included), IEEE 802.3at PoE, Support Port Forwarding, NAT Etc complete in all respects as desired by the Engineer in charge of work at site. 152 1 Each 8528 Excess(+) Full Conversion INR
151 SITC of Token Calling Display System having screen size 4 inches, Voice calling with Bell System, complete key pad Etc, calling display up to 60 meter cable (15 meter length included), serial communication design, Text Color Red Display Shape Rectangle, Power 5 W, Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital, Cash counter, Tehsil, Courts etc, Warranty 1 Year,220 VAC Operating Voltage character Capacity 3 Character, Power Consumption, Rectangular Metal body complete in all respects as desired by the Engineer in charge of work at site. 153 4 Each 13040 Excess(+) Full Conversion INR
152 each 154 1 Each 9605 Excess(+) Full Conversion INR
153 Supply & installation of 9U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks complete in all respects as desired by the Engineer in charge of work at site. 155 1 Each 87700 Excess(+) Full Conversion INR
154 Supply, Installation, Testing & Commissionning of ExiLED M ST LED LED based exit sign with dimming function, Reading distance, exit sign Two-sided 25m, Voltage 220-240VAC / 50-60Hz, Power consumption 3.3W / 3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection /deep discharge protection, Charging Time 16 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540 / 742 gr , Colour Anodized aluminum / black plastic, Materials Aluminum, Acrylic Plate, Mounting method Ceiling, wall bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40 – dustproof luminaire Reading distance upto 25 meters.High lumen output – 1h = 180lm / 3h = 110lm /8h = 40lm Technical lifetime of LED > 100 000 hours , 4 Pictograms (left, right, down, u 156 4 Each 43599 Excess(+) Full Conversion INR
155 Supply, Erection, Testing and Commissioning of 3 KVA Double Conversion Online UPS System including Batteries 12V 65ah Amp hrs. True Online Pure Sine wave DSP Controlled online UPS with single phase AC input and single phase AC output with inbuilt Isolation Transformer of same OEM make at Input Including installation & 2 years warranty. Along with battery rack, interconnection cables & 5/7-meter DC wire from UPS to battery bank and other standard accessories of UPS & Battery Bank. UPS is with inbuilt Phase sequence correction & protection feature , TVSS & Cold start feature and emergency power off (EPO) feature & dust filters, manual & automatic bypass inbuilt and UPS should be capable for Parallel operation up to 4 same units with additional optional PRS kit. UPS Rating : KVA 3, Load Power Factor: PF 0.8, Efficiency: 0.9, Nominal DC Voltage: VDC 12Vx no of batteries 8, No of Batteries: 8, End Cell Voltage: 1.75x6: 10.5, DC Watts: = (KVA X 1000 X PF) / (Inv Eff X No. of batt) Watts, DC watts: UPS load DC wattage 444, Backup time: in mins 60, AH Offered: AH rating of SMF battery: 65AH, No of cells/Batteries: 1string of 8 no. of 65AH, Min VAH of bank for 60 min: 1 set of 8 no. of 12V-65AH 10080, Battery AH Wattage: 65AH battery gives Backup calculation: Backup Achieved in min = battery AH wattage x 60 Min / UPS load DC watts: 33.14 min, Backup achieved more than 60 min backup achieved: on SMF battery bank with 10080VAH on 0.8LPF for 3KVA UPS. This 3kVA double-conversion on-line 2U rackmount UPS provides pure sine wave power to support critical electronics during power disruptions, with IEC 320 C20 input, 6x IEC 320 C13 and 1x IEC 320 C19 outlets. The On-Line UPS has a intelligent card slot for optional Network Management Card that enables network-based UPS monitoring and management. The UPS can connect to EcoStruxure IT or third-party centralized management platforms. The Built-in automatic and manual bypass provide seamless power to the load even in the event of an internal detected fault or error in UPS. The UPS is compatible with replacement battery cartridge APCRBCV202. The UPS is compatible with rail kit sold separately. The UPS and the built-in lead-acid battery has a 2-year warranty. Ideal for small data centers, manufacturing facilities, computer rooms, network storage devices, telecommunication, and healthcare IT. Complete in all respects as desire by the Engineer in-charge of work at site. 157
156 Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP54/55). Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel wi 158
157 Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design 159
158 Heavy duty 160 153.35 Supplying & Fixing of M.S pipe bail plug suitable for 200 mm dia UPVC casing pipe having thickness of socket as 12 mm ,length 100 mm & base plate of 8 mm thick complete in all respect. 396.16 Excess(+) Full Conversion INR
159 ll be made out of 75 x 40 x 5mm rolled channel. 161 191.21 Supplying & Fixing of M.S pipe bail plug suitable for 200 mm dia UPVC casing pipe having thickness of socket as 12 mm ,length 100 mm & base plate of 8 mm thick complete in all respect. 306.82 Excess(+) Full Conversion INR
161 iii) PUBLIC HEALTH WORKS 163
162 Job 164 44 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 316.12 Excess(+) Full Conversion INR
163 Sub Head-1 Internal Sewerage System 165
164 75mm o/d single socket SWR UPVC pipe lines laid complete 166 28 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 162.57 Excess(+) Full Conversion INR
165 Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. 167 14 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 45.4 Excess(+) Full Conversion INR
166 For 160mm o/d pipes 168 42 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 111.09 Excess(+) Full Conversion INR
167 Elbow 90 degree (all side socket) for Rain pipe 169 33 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 206.15 Excess(+) Full Conversion INR
168 For 110mm o/d pipes 170
169 Elbow 90 Degree (All side socketed) 171 37 Each 309.99 Excess(+) Full Conversion INR
170 Vent Cowls 172
171 Coupler 173 40 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 74.71 Excess(+) Full Conversion INR
172 For 160mm o/d pipes 174 29 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 74.71 Excess(+) Full Conversion INR
173 Single Tee 175
174 P Trap/Floor Trap 110mm x 75mm 176 247 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 101.27 Excess(+) Full Conversion INR
175 With 90mm i/d outlet deep seal at Ground Floor 177 96 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 85.71 Excess(+) Full Conversion INR
176 For 75mm o/d pipes 178
177 Elbow 90 degree (all side socket) 179 110 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 217.18 Excess(+) Full Conversion INR
178 Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in- charge) 180
179 110mm o/d 181 15 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 1930.01 Excess(+) Full Conversion INR
181 90mm o/d 183 10 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 6780.33 Excess(+) Full Conversion INR
182 Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. 184
183 M.S. Holder bats clamps for 100mm i/d as per table-1 185 153.35 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 608.08 Excess(+) Full Conversion INR
184 Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. 186 22 Each 100 Excess(+) Full Conversion INR
185 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm as per table-1 187
186 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal 188
187 Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients,cutting, jointing and testing complete as perspecifications. 189 39.94 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 188.28 Excess(+) Full Conversion INR
188 160mm o/d PVC pipe of 4 Kgf. / sqcm for rain water 190 57.62 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 233.19 Excess(+) Full Conversion INR
189 MS Round Jally 191 175.3 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 301.04 Excess(+) Full Conversion INR
190 Sub Head-2 Internal Water Supply System 192 180.18 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 402.83 Excess(+) Full Conversion INR
192 CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 194 257.01 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 72.69 Excess(+) Full Conversion INR
193 CPVC SDR 11 Pipe & fitting 16mm o/d 195
194 SDR 11 CPVC pipes & fittings 20mm o/d 196 13 For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky 176.42 Excess(+) Full Conversion INR
195 CPVC SDR 11 Pipe & fitting 25mm o/d 197 9 For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky 251.71 Excess(+) Full Conversion INR
196 CPVC SDR 11 Pipe & fitting 32mm o/d 198
197 qty same as GI P 15mm i/d to 25 mm (Table-2) 199 19 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 893.91 Excess(+) Full Conversion INR
198 Construction of Septic Tank size 2.00 Mtr x 1.50 Mtr. Internal size with 2.0 Mtr. Internal depth in RCC, 3 no. Chambers medium duty man hole cover complete as per drawing / specification and to the entire satisfaction of Engineer-in-charge. (Note :- Payment will be made as per CSR Based Rates Plus Minus Quoted rates). 200
199 Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. 201 8000 Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis) 11.38 Excess(+) Full Conversion INR
200 Making soak pit 2.5 m outer Diametre 3.0 metre deep 230mm thick 1:5 brick work honey comb with bricks of Ist Class and S.W. drain pipe 100 mm Diametre, 1.8 m long complete as per standard design. With FPS Bricks 202
201 Through wall 11.43 cm thick Detail as per Table-2 203 4 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 1599.98 Excess(+) Full Conversion INR
202 Through wall 22.86 cm thick Detail as per Table-2 204
203 Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. 205 8 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 258.57 Excess(+) Full Conversion INR
204 32mm i/d Brass Ball valves 206
205 2000 ltr Capacity (4 Nos ×2000 ltrs) 207 4 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 198.82 Excess(+) Full Conversion INR
206 Brass Ball Cock with rod and Plastic Ball 32mm i/d 208 18 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 280.35 Excess(+) Full Conversion INR
207 Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. 209
208 32mm i/d G.I. Union 210 4 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 3750 Excess(+) Full Conversion INR
209 Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. 211
210 No 212 3 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 5607.78 Excess(+) Full Conversion INR
211 G.I. tank nipple 25mm i/d 213 11 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 5035.73 Excess(+) Full Conversion INR
212 G.I. tank nipple32mm i/d 214
213 Construction of Plateform complete as per specification & as desired by Enginer-in-charge 215 11 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 381.37 Excess(+) Full Conversion INR
214 For 2000 ltr Water Tank 216 11 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 87.44 Excess(+) Full Conversion INR
215 Sub Head - 3 Sanitary Installation 217 2 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 6901.48 Excess(+) Full Conversion INR
216 Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. 218 2 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 4900.88 Excess(+) Full Conversion INR
217 Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. 219 1 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 9108.56 Excess(+) Full Conversion INR
218 Providing and fixing jet spray with 2'-6" long PVC pipe.With PTMT nut 220
219 Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in- charge ) complete in all respect. 221 13 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 4624.87 Excess(+) Full Conversion INR
220 Fire Fighting Arrangements 222 33 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 122.21 Excess(+) Full Conversion INR
221 Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. 223 17 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 119.05 Excess(+) Full Conversion INR
222 Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm 224 1 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 1182.03 Excess(+) Full Conversion INR
223 Providing & fixing in position Water Dispenser Top Loading (with refrigration capacity 15 ltr) of approved make (to the approval of Engineerin-charge ) dispensing hot/cold/ambient water including cost of two no. 20 ltrs packaged drinking water bottles and carriage complete in all respect. 225
224 Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. 226
225 size 44cm dia (under counter round) 227 15 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 959.74 Excess(+) Full Conversion INR
227 Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. 229 4 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 1758.29 Excess(+) Full Conversion INR
228 Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-in-charge) complete in all respect. 230 15 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 888.1 Excess(+) Full Conversion INR
229 Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity 231
230 Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. 232 8 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 1214.69 Excess(+) Full Conversion INR
231 C.P. brass towel Rails size 15mm dia 610mm long 233 13 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 966.06 Excess(+) Full Conversion INR
232 C.P brass towel ring 234
233 CP brass Acrylic Shelf size 560mmx130mm 235 36 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 870.19 Excess(+) Full Conversion INR
234 Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. 236 11 Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity 1268.41 Excess(+) Full Conversion INR
235 C.P. brass Bib cock long nose/ long body without flange 237 150 Mtrs 66.37 Excess(+) Full Conversion INR
236 Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B 238 83 Mtrs 112.72 Excess(+) Full Conversion INR
237 C.P Brass bib cock foam flow without flange 239 13 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 1263.15 Excess(+) Full Conversion INR
238 110mm o/d single socket SWR UPVC pipe lines laid complete 240
239 Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. 244 14 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 1174.65 Excess(+) Full Conversion INR
240 C.P.brass 15mm Angle valve without flange 245 2 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 2951.91 Excess(+) Full Conversion INR
241 Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm 246 21 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 386.63 Excess(+) Full Conversion INR
242 C.P.brass 15mm Concealed stop cock with flange 247 2 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 510.84 Excess(+) Full Conversion INR
243 Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. 248
244 Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer 249 4 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 1833.09 Excess(+) Full Conversion INR
245 -in- Charge) (Size 600mm x 450mm) 250 2 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 2809.68 Excess(+) Full Conversion INR
246 C.P. brass toilet roll holder with flap 251 2 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 6652.85 Excess(+) Full Conversion INR
247 C.P. brass towel rack 600mm long with lower hangers 252
248 Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in- charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect. 253 3 Each 4994.64 Excess(+) Full Conversion INR
249 Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect. 254 3 Each 2222.89 Excess(+) Full Conversion INR
250 Credit of Old Bricks 255
251 35mm dia 900mm (36”) long 256 2 Each 9324.06 Excess(+) Full Conversion INR
252 35mm dia 1200mm (48”) long 257
253 Foldable U Type 762mm long 258 64.07 ltrs 424.56 Excess(+) Full Conversion INR
254 Providing and fixing in position vitreous Chinaware white laboratory sinks of approved make (to the approval of Engineerin- charge) consisting of a pair of brackets, C.P. brass waste 40mm complete in all respect. 259 63.14 ltrs 889.15 Excess(+) Full Conversion INR
255 Size 450 mm x 300 mm x 150 mm 260 236.37 ltrs 898.64 Excess(+) Full Conversion INR
256 Providing and fixing in position C.P elbow action pillar tap of approved make (to the approval of Engineer-in-charge) complete in all respect. 261 7.23 ltrs 3453.37 Excess(+) Full Conversion INR
257 25 litre capacity water heater 262 8.71 No. 187.52 Excess(+) Full Conversion INR
258 Sub Head-4 Flooring and Wall Tile 263
259 Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material 264
260 Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete . 265 3 For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky 46849.15 Excess(+) Full Conversion INR
261 Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks 266 3 SITC of CAT 6 TWO Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps complete in all respects as desired by the Engineer in charge of work at site. 5008.44 Excess(+) Full Conversion INR
262 Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 267 8 SITC of CAT 6 TWO Meter long Patch Cord Having RJ-45 Male Connectors on both ends DCC up-to 10/100/1000 mbps complete in all respects as desired by the Engineer in charge of work at site. 7151.79 Excess(+) Full Conversion INR
263 Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. 268 3 Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity 13369.97 Excess(+) Full Conversion INR
264 Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) 269 2 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 52285 Excess(+) Full Conversion INR
265 Sub Head -5 Water Coller & AC 270 3 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 74588 Excess(+) Full Conversion INR
266 Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. 271 3 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 45949 Excess(+) Full Conversion INR
267 Water Cooler Full Steel Body 150/150 ltr without Stablizer 272 64 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 1676 Excess(+) Full Conversion INR
268 Job 273 64 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 194.32 Excess(+) Full Conversion INR
269 Sub Head-3.2 Septic Tank size 2.00 Mtr x 1.50 Mtr & soak pit 274
270 CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 275 64 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 72.69 Excess(+) Full Conversion INR
271 CPVC SDR 11 Pipe & fitting 16mm o/d 276
272 SDR 11 CPVC pipes & fittings 20mm o/d 277 9 For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky 176.42 Excess(+) Full Conversion INR
273 CPVC SDR 11 Pipe & fitting 25mm o/d 278 9 For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky 251.71 Excess(+) Full Conversion INR
274 Automatic Voltage Stablizer 4 KVA ( For AC's) 279
275 Credit of Old Brick tiles 280
276 Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball 281 120 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 954.52 Excess(+) Full Conversion INR
277 Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. 282
278 Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 5 Star Inverter Type ( having ISEER Rating 5 and Cooling Capacity 5200 W Minimum) witht MCB arrangement for installing OD units on terrace/Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects 283 110 nos 1066.75 Excess(+) Full Conversion INR
279 Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 5 Star Inverter Type( having ISEER Rating 5 and Cooling Capacity 6000 W Minimum) with MCB arrangement for installing OD units on terrace/ Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects 284
280 Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 5 Star Inverter Type ( having ISEER Rating 5 and Cooling Capacity 5200 W Minimum) witht MCB arrangement for installing OD units on terrace/Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects 285 10 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 1416.58 Excess(+) Full Conversion INR
281 Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut 286 1 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 1115.14 Excess(+) Full Conversion INR
282 Providing & Installing & Erection split type wall mounted air conditioner capacity 1 tonne 5 Star ( having ISEER Rating 5 and Cooling Capacity 3500 W Minimum) with MCB arrangement for installing OD units on terrace/ Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects 287 1 Each 417.73 Excess(+) Full Conversion INR
283 Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. 288 3 Each 295.38 Excess(+) Full Conversion INR
284 Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long 289 1 Each 608.53 Excess(+) Full Conversion INR
285 Providing laying hard soft copper concealing of copper pipes of various dia as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects. 290
286 Providing and installation of tube well, & Developmentof Head works 291 8 mtr 3509.52 Excess(+) Full Conversion INR
287 Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories: 292 3 For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky 5981.44 Excess(+) Full Conversion INR
288 cum 293 6 mtr 1907.99 Excess(+) Full Conversion INR
289 Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer – incharge. 294 1 nos 2000 Excess(+) Full Conversion INR
290 150 mm nominal size dia. 295 1 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 32240 Excess(+) Full Conversion INR
291 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 296 1 INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. 12000 Excess(+) Full Conversion INR
292 Supplying and fixing well cap having threads to fix on housing pipe complete in all respect 150mm id. 297
293 Development and stabilizing of the Tubewell with Air Compressor required capacity as directed by the Engineer- in-charge including the cost of tools and appliances and consumable to the satisfaction of Engineer-in-charge. 298 46 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 721.9 Excess(+) Full Conversion INR
294 Capacity of Air compressor 300 cfm at 250 PSI 299
295 Providing sterlization of tubwell as per IS 2800-1991 300 125 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 144.12 Excess(+) Full Conversion INR
296 Providing and Installing Testing & Commiissioning of 1 Nos Electrically driven submersible Pump set of capable of delivering 20 LPM against a head of 47 mtr. 301 1 Supply, Installation, Testing & Commissionning of AgoraLED NM LED IP65 230V 2X6W 1h/3h/8h. The luminiare comes in plastic housing. Mounting bracket is not required for this luminaire, IP65/NA 0 Non -Maintained Self Testing 12V / 7Ah Pb, LED based for anti-panic area, surface assembly Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch High lumen output – 1h = 360lm / 3h = 170lm / 8h = 70lm Simple and quick assembly and maintenance Technical lifetime of LED > 100 000 hours • IP65 – dust and waterproof luminaire, Voltage 220-240VAC / 50-60Hz Power consumption 11.4W / 11.8VA Battery 12V / 7Ah Pb Battery protection Over charge protection /deep discharge protection Charging Time 23 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source LED 2x6, Technical lifetime (light source) >100 000 hours, Lumen output, emergency (1h / 3h / 8h) 3200 / 1600 / 800 lm, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IP rating IP65, Dimensions 302 x 94 x 210 mm, Weight 4200 / 4420 gr, Materials PC/ABS, PC, Aluminium, Mounting method Wall mounting. The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab. Complete in all respects as desired by the Engineer in charge of work at site. 56765 Excess(+) Full Conversion INR
297 Providing and Installing Electric Control panel board consisting of electrical appliances such as automatic star Delta Push Button or oil immersed starter, Main switch, VM, Ampere Meter, ELCB, shut capacitor. Single phase, preventer, indicating laps, Kit-Kat etc. complete ina all respets. 302
298 Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. 303 1 Supplying at site wooden box of suitable size with lid and locking arrangement for preserving strata sample received from the bore 17000 Excess(+) Full Conversion INR
300 Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- 305
301 Overall size 2.5sq.mm (84/0.3mm), 3Core 306 155.1 Nos 104.4 Excess(+) Full Conversion INR
302 Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs 307
303 Construction of Mini Pump Chamer Cabinet Type with door including steel door complete in all respect as per drawing attached with entire satisfaction of engineer-in-charge. 308 235 Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. 577.1 Excess(+) Full Conversion INR
304 CPVC SDR 11 Pipe & fitting 32mm o/d 309
305 Disinfection Un 310 2 Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity 1796.25 Excess(+) Full Conversion INR
307 Providing, installing, testing and commissioning one no. electrically actuated diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 ltr. o f bleaching powder solution/ sodium hypo solution per hour under maximum delivery pressure up to 7kg cm2, and suction lift not less than 1.5m, as per DWSS standard specification ( Make: Milton Roy or equivalent Make) 312 2 Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity 5589.83 Excess(+) Full Conversion INR
308 Estate Water Supply 313
309 Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. 314
310 Earth work upto 1.5 m. Depth All classes of soil except rocky 315 60 each 599.23 Excess(+) Full Conversion INR
311 SDR 11 CPVC pipes & fittings 50mm o/d 316 196.1 each 1253.39 Excess(+) Full Conversion INR
312 50mm i/d Sluice Valves flanged 317
313 Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. 318 165.66 Nos 104.3 Excess(+) Full Conversion INR
314 Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet b 319 73.67 Nos 687.83 Excess(+) Full Conversion INR
315 50mm i/d Sluice Valves flanged 320
316 ox of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- Automatic Voltage Stablizer 2 KVA 321 40.3 Nos 104.3 Excess(+) Full Conversion INR
317 Size 0.6 m. x 0.6 m. 322 5.42 Nos 3812.62 Excess(+) Full Conversion INR
318 Sub Head-1 Estate Sewerage 323 13.88 Nos 5382.33 Excess(+) Full Conversion INR
319 Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. 324 2.74 Nos 4919.85 Excess(+) Full Conversion INR
320 110 mm o/d pipes 325 9.9 ltrs 30.55 Excess(+) Full Conversion INR
321 160 mm o/d pipes 326 48.83 ltrs 209.65 Excess(+) Full Conversion INR
322 Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects. 327 48.83 ltrs 62.16 Excess(+) Full Conversion INR
323 For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky 328 3.88 Nos 5428.69 Excess(+) Full Conversion INR
324 Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type 329 3.1 sqm 7920.58 Excess(+) Full Conversion INR
325 First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth 330 44 For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky 220.18 Excess(+) Full Conversion INR
327 Cement Concrete 1:2:4 with stone ballast or shingle.using concrete mixing volumetric type 332 11 For depth not exceeding 3.0 m B.G.L. For all classes of soil except rocky 2045.9 Excess(+) Full Conversion INR
328 Floating coat of 1:5mm thick neat cement laid in one operation to the topping 333
329 12.5 mm thick cement plaster 1:3 334 1 Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide, Urainium etc.) 161695 Excess(+) Full Conversion INR
330 Cement rendering on plaster 1mm thick 335 1 Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide, Urainium etc.) 23525.71 Excess(+) Full Conversion INR
331 Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. 336
332 Boring with 200mm id Housing Pipe Upto 150 m depth BGL. 337 8 Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity 7150.19 Excess(+) Full Conversion INR
333 Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete 338 8 Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity 2940.3 Excess(+) Full Conversion INR
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.98 MB
BOQ_313237.xls
BOQ • 0.75 MB
DRAWING.pdf
Tender Documents • 2.98 MB
SBD.pdf
Tender Documents • 16.31 MB
Technical_Conditions.pdf
Tender Documents • 1.44 MB
Additional_Conditions.pdf
Tender Documents • 7.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .