Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-Finance | L1 | Accepted-Finance Qualified | |
| 2 | L2₹11.4 L+₹81,464 (7.70%)Accepted-Finance | L2 | Accepted-Finance Qualified | |
| 3 | L3₹15.6 L+₹5.0 L (47.5%)Accepted-Finance | L3 | Accepted-Finance Qualified |
| Sl No | Description | Qty | Unit | JAI AMBA CONSTRUCTION L2 | Vivek Electricals L1 | C B S ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00Carriage of fallowings from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 Kms. | ||||||
| 2.00 | S.T Pole 11 Mtr. Long | 10 | Nos. | 500 ₹5,000 | 400 ₹4,000 Lowest | 5,000 ₹50,000 |
| 3.00 | PCC Pole 11 Mtr. Long | 39 | Nos. | 1,100 ₹42,900 | 1,000 ₹39,000 Lowest | 1,500 ₹58,500 |
| 4.00 | PCC Pole 09 Mtr. Long | 71 | Nos. | 600 ₹42,600 | 500 ₹35,500 Lowest | 800 ₹56,800 |
| 5.00 | Carriage of All line Material from store center BSR to j.e store Sub station as ACSR Weasel conductor, ABC conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator & 33kv XLPE cable etc. | 20 | Qtl. | 2,100 ₹42,000 | 2,000 ₹40,000 Lowest | 2,500 ₹50,000 |
| 6.00 | Erection of Single pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. | 84 | Nos. | 3,100 ₹2,60,400 | 3,000 ₹2,52,000 Lowest | 3,500 ₹2,94,000 |
| 7.00 | Erection of Double pole/Section Pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. | 6 | Nos. | 5,000 ₹30,000 | 4,500 ₹27,000 Lowest | 7,000 ₹42,000 |
| 8.00 | Erection of Try pole/Section Pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. | 8 | Nos. | 8,200 ₹65,600 | 8,000 ₹64,000 Lowest | 10,000 ₹80,000 |
| 9.00 | Grouting of Single support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. | 84 | Nos. | 700 ₹58,800 | 600 ₹50,400 Lowest | 1,000 ₹84,000 |
| 10.00 | Grouting of Double pole support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. | 6 | Nos. | 1,300 ₹7,800 | 1,200 ₹7,200 Lowest | 2,000 ₹12,000 |
Tender Value
Refer Docs
EMD Value
₹11,000
Closing Date
10 Oct 2025, 11:00 amClosed
SE, EDC-III BULANDSHAHR
SE, EDC-III BULANDSHAHR
Work of shifting 33 KV line under full deposit scheme in the jurisdiction of Electricity Distribution Division-Jahangirabad.
2025_PVVNL_1079662_1
48/EDC-III/B/2025-2026
Open Tender
Electrical Works
Lump-sum
30 days
SE, EDC-III BULANDSHAHR
Work of shifting 33 KV line under full deposit scheme in the jurisdiction of Electricity Distribution Division-Jahangirabad.
2 documents required · 2 mandatory
₹3,540
SE, EDC-III BULANDSHAHR
₹11,000
16 Oct 2025
3 Oct 2025
10 Oct 2025
3 Oct 2025
10 Oct 2025
3 Oct 2025
Amount
Carriage of fallowings from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 Kms.
S.T Pole 11 Mtr. Long
PCC Pole 11 Mtr. Long
PCC Pole 09 Mtr. Long
Carriage of All line Material from store center BSR to j.e store Sub station as ACSR Weasel conductor, ABC conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator & 33kv XLPE cable etc.
Erection of Single pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of Double pole/Section Pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of Try pole/Section Pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Single support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Double pole support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Try pole support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Cutting /drilling /Welding of MS Angle iron for making guarding angle size 65x65x6/50x50x6 mm including the work of fixing the bracket on PCC/ST pole for construction of the line.
Fixing of 33kv/11 Kv Stay rod with Stay wire in proper way with Nozelling
Grouting of 33kv/11 Kv Stay rods
Laying, sagging. Stringing and binding and jumpering of ACSR Weisal , rabbit, dog newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work.
ACSR Dog conductor
Fixing of Earthing rod
Providing & Fixing of Danger Board
Fixing of 33 KV DISC
Providing & Fixing of 33 KV F Braket
Providing & Fixing of 33 KV F Clamp
Fixing of 33 KV PIN INSULATER
Fixing of 33 KV X-ARM V Type
Fixing of 33 KV V Type X-ARM 100*50*6
Fixing of Top Channel
Fixing of MS Channel
Providing & Fixing of MS Clamp
Providing & Fixing of X ARM V HOLDING CLAMP
Providing & Fixing of CLAMP OF 33 KV V TYPE CROSS ARM
Providing & Fixing of NUMBER PLATE WITH CLAMP & NUT BOLT
Providing & Fixing of Nut & Bolt off size
Providing & Fixing of EARTH WIRE CLAMP WITH BOLT & NUT
Fixing of ston pad
Providing & Fixing of Barbid wire of poles
Providing & Fixing of Aluminum binding wire
Fixing of MS Brassing set
Fixing of GI wire 6/10
Fixing of MS ANGLE
Recive back material.
OLD & Used Damaged ST Pole Scrap
MS scrab
ACSR condctor wire scrab
Above work shall be done as per UPPCL/RESPO Rules.
JAI AMBA CONSTRUCTION (BID ID -5592015)
C B S ENTERPRISES (BID ID -5595351)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .