Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.0 LAccepted-AOC | L-1 | Accepted-AOC Work Awarded | |
| 2 | L-2₹3.0 L+₹1,099 (0.37%)Rejected-Finance A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | L-2 | Rejected-Finance L2 rejected |
| Sl No | Description | Qty | Unit | M/S. A.K. Electricals L2 | The Electrician L1 |
|---|---|---|---|---|---|
| 1.00 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required | 2 | Set | 4,000 ₹8,000 Lowest | 6,855 ₹13,710 |
| 2.00 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | 4 | Meter | 2 ₹8 | 1 ₹4 Lowest |
| 3.00 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 136 | Meter | 2 ₹272 | 1 ₹136 Lowest |
| 4.00 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 250 | Meter | 20 ₹5,000 | 10 ₹2,500 Lowest |
| 5.00 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | 45 | Each | 160 ₹7,200 Lowest | 261 ₹11,745 |
| 6.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm | 130 | Meter | 2 ₹260 | 1 ₹130 Lowest |
| 7.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm | 320 | Meter | 2 ₹640 | 1 ₹320 Lowest |
| 8.00 | Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) | 130 | Meter | 150 ₹19,500 | 50 ₹6,500 Lowest |
| 9.00 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm | 300 | Meter | 60 ₹18,000 Lowest | 72 ₹21,600 |
| 10.00 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm | 150 | Meter | 70 ₹10,500 | 10 ₹1,500 Lowest |
Tender Value
Refer Docs
EMD Value
₹7,675
Closing Date
11 Jul 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ex. Engineer (Elect)-I
OFFICE OF THE Ex. ENGINEER (ELECT)-I, SHAHDARA (N) ZONE, Keshav Chowk, Delhi-110053
Repair of Fancy Lights ward Bhajanpura-Repair and Maintenance of Existing Fancy Lights in Chaudhary Hansraj Park and at other various location in Bhajanpura Ward-230
2023_MCD_159841_1
EE(E)-I/Sh.N/MCD/23-24/TC-13/2
Open Tender
Electrical Works
Item Rate
60 days
As per NIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
₹7,675
7 Feb 2026
4 Jul 2023
12 Jul 2023
4 Jul 2023
11 Jul 2023
4 Jul 2023
Amount
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
SITC of 25 watt LED IP65 post top fitting made of die cast aluminium spigot spun aluminium powder coated top cover and clear acrylic diffuser with high voltage protection low power LED's connected in series and parallel combination with better heat sink arrangement input voltage 160-260 volts AC, 50 Hz AC Supply power factor >0.95, luminious efficacy >100 lumens/watt, CCT 5700°K ±300°K, Surge protection not less than 10KV complete etc as requred.
M/S. A.K. Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .