| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC H NO 61 KALYANI SAGAR PATH BAGADATPUR KAHILIPARA DIST KAMRUP M | KAMRUP | ASSAM | 781030 | ₹1.5 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹1.5 Cr+₹47,138.60 (0.31%)Rejected-Finance VILL KALYANPUR W NO 5 P O BISWANATH DISTRICT BISWANATH | BISWANATH | ASSAM | 784166 | ₹1.5 Cr+₹47,138.60 (0.31%) | L2 | Rejected-Finance Not Admitted |
| 3 | L2₹1.5 Cr+₹47,138.60 (0.31%)Rejected-Finance | ₹1.5 Cr+₹47,138.60 (0.31%) | L2 | Rejected-Finance Not admitted |
| 4 | Rejected-Technical ASSAM AS | NAGAON | ASSAM | 782136 | - | - | Rejected-Technical Not admitted |
| 5 | Rejected-Technical LUHITPUR KALAMUAGAON DIST DHEMAJI PIN 787059 | DHEMAJI | ASSAM | 787059 | - | - | Rejected-Technical Not admitted |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
18 Oct 2024, 1:00 pmClosed
Chief Engineer Minor Irrigation Assam
O_O the Chief Engineer Irrigation Assam Chandmari Guwahati_03
Installation of 20 Nos. of Solar Tube Well Points from villlageDandua to Barapujia in Morigaon LAC under RIDF-XXX NABARD for the year 2024-25under Morigaon-Laharighat- JagiroadDivision Package_49
2024_ID_39149_49
01_RIDF_XXX_2024_25 Date_21_09_2024
Open Tender
Civil Works
Item Rate
180 days
Morigaon
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,500
₹3.4 L
Yes
O_O the Chief Engineer Irrigation Assam Chandmari
24 Feb 2025
25 Sept 2024
19 Oct 2024
25 Sept 2024
18 Oct 2024
27 Sept 2024
5 Oct 2024
Amount
Supply & Lowering of Pipes & Filters, Shrouding of TW, Developing of TW , MS Clamp Pump Support, etc.
Item 1: Boring of DTW :- Boring of DTW of bore hole up to 450 mm dia and up to a depth of 54 M or up to required depth by RC/DR Drilling Rig including supply and transportation of all required Tools & Plants, materials & Labour to site to perform the job in complete as directed in alluvium areas (means areas where the strata comprises of loose, unconsolidated materials like clays, silts, sands gravels, pebbles, cobbles and boulders) as per IS: 2800 (part-I) of 1991. ( Soil sample must be collected & keep properly at every 3.00 M interval of depth in boring. The job also include movement of Rig by making temporary approach road etc. to the field up to distance of 1000 M.)
Item 2: Supply & Lowering, etc. of Pipes :- Supply, lowering & installation in tube well 150 mm PVC housing pipe / blind pipe of wall thickness of 6.5 mm to 8.5 mm for casing assembly including supply of well cap, sockets, reducer, MS housing clamps etc. as required as per IS : 12818-1997 of length 3.00 M of repute brand like Supreme / Oriplast / Jindal / Prince etc. and as directed. (Litholog Assembly diagram must be approved by Engineer - in - charge of the work prior to installation)
Item 3:Supply & lowering, etc. of Filter :- Supply, lowering & installation in tube well 150 mm PVC Ribbed Screen Filter pipe of wall thickness of 6.5 mm to 8.5 mm for casing assembly including supply of sockets, reducer etc. as required as per IS : 12818-1997 of length 3.00 M/2.00 M of repute brand like Supreme / Oriplast / Jindal / Prince etc. and as directed. (Litholog Assembly diagram must be approved by Engineer - in - charge of the work prior to installation)
Item 4: Shrouding of TW :- Shrouding of the Tube well assembly by packing of river Pea Gravel of size 4mm to 8 mm free from sand, dust and any other foreign materials after staking at site including screening, washing etc as per IS 4097/2008 along with transportation, labour etc. complete as directed and (Packing to done after lowering tube well assembly and also during development as reqd)
Item 5: Developing of TW :- Developing the tube well assembly by Air-Compressor of capacity 8 – 12 kg/cm2 and CFM = 450 M3/Min so as to get sand free discharge of water with supply of all required materials at site complete as directed including furnishing of litho log / draw down data, etc. as per IS:11185 of 1999. The following data should be reflected in the report of development : 1. Static water level 2. available average discharge 3. Drawdown at different discharge (arrangement of Pump for trial pumping is in the scope of the work)
Supply ,Installation and commissioning of Solar Pump along with PV Panels etc
Item no. 1: Supply & Installation of Solar Pumping System: (a) Solar Submersible S tandalone Pump set with 7.5 HP AC Induction motor and Solar Power Controller Unit ( Conform IEC 6168311:1999) with overload, over-under voltage, short circuit protection, suitable for 200 mm bore well and discharge capacity approx. 1400 LPM at 10 M head (Dynamic Head Range 10-20 Mtr and Shut off head 30 M) working at 8000 Wp of solar power along with Cables, Inverter external box, surge suppressor, DC MCB & all necessary accessories like, 2(two) pairs of G.I. Assembly support clamps, 10(ten) nos. of Cable clamp / clip, 1 (one) no. of Delivery bend, 1 (one) no. enlarger/ reducer as required, 20(twenty) mtr. Column pipe of uPVC/ HDPE of working pressure of minimum 8kgf, 1(one) no. of Short pipe of 1.5 Mtr. length of required diameter, 40(forty) mtr.(approx.) Flat flexible cable (motor to controller) as per latest MNRE norms and as per IS. (b) Supply, fitting-fixing and testing & commissioning of Solar PV modules conforming to IEC 61215 specification or equivalent National or International standards consisting of solar panels framed in anodized aluminium frame of 8000 Wp (approx.) considering 7.15 kWh/ M2/ Day of solar insolation under standard test condition on horizontal surface with tolerance (+/-) 15% and hot dipped galvanized (minm 80 micron thickness) mounting mild steel structure of rectangular hollow sections, angles, heavy duty pipes of dia. 150 mm (all materials duly IS marked ) for providing sufficient strength with dual axis manual tracking arrangement which can withstand load of modules and high wind velocities upto 150 Km/hr including RCC foundation designed against all possible loads (Dead, Live and imposed load), Controller conform to IEC 61683–1999 & IEC 60068-1-2, IEC 60068 - 2- (2, 14, 30, 78) ( The series and parallel combination of Solar Modules to be done in such a way that Jalverter/ Controller input voltage requirement is met i.e. System Vmp> 587 V & System Voc< 800 V) and necessary connection cables, pipes to the water trough and other accessories, etc. complete in all respect as directed. (Controller to be installed with suitable arrangement on the body of the pole of mounting structure with rain proof provision. SPV panel should be of reputed make and carry at least 20 years warranty& comprehensive maintenance for 1 year and should installed preferably above HFL) (c) Earthing with 50 mm dia. GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia. x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia. GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. Below the ground level as below: (a) By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipment incl. drilling holes, with bolts, nuts, washers etc. (d) Lightning protection (Arrestor)(pole mounted)(: Lightning protection with 3" X 1.5" G.I pipe of 4 mts. height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia. 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia. 6 mm thick GI base plate at bottom incl. necessary holes etc. including supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the/Roof with GI Saddles 1100 mm apart. NB :- 1. Solar Pump set should be of reputed make and carry 5 years warranty/ guarantee. 2. Flow Range : 90 L per Wp of PV array from TDH of 10 M, 3. Controller DC Input Voltage: (i) System Vmp> 587 V & (ii) System Voc< 800 V, 4. Controller Conforming to : IEC 61683–1999 & IEC 60068-1-2,IEC 60068–2-(2,14,30,78), 5. The system should carry anti-theft mechanism (Rate As per MNRE Circular No. 32/24/2020-SPV Division, dt-26/10/2021 including cost of remote monitoring & USPC) This benchmark cost are for the systems installed as per MNRE specifications inclusive of the total cost of system and its installation, commissioning, transportation, insurance, warranty/guarantee, monitoring & maintenance for five years. Cost of Solar Standalone Pumping System = Rs 4,08,631.00 Add GST @ 18 % = Rs73,553.58 Cost Solar Pumping System = Rs 4,82,184.58
Sign Board
Item no. 1: Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed.
Supply of Canvas Pipe 65 mm Dia
Supply of Canvas Pipe 65 mm Dia
Ashim Hazarika (BID ID -244215)
BIPUL MEDHI (BID ID -241666)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .