Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.3 L+₹2.1 L (20.2%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹12.4 L+₹2.1 L (20.9%)Rejected-Finance NEAR SURAJ ICE FACTORY TALAB TILLO JAMMU | L3 | Rejected-Finance Being L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹10.3 L
EMD Value
₹20,600
Closing Date
8 Jan 2018, 2:00 pmClosed
Executive Engineer
Executive Engineer University Works department University of Jammu
Lighting and installation of exhaust fans in gumnasium hall at new University Campus
2017_UDJK_49254_1
enit280 dated 27-12-17
Open Tender
Electrical Works
Item Rate
30 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
Executive Engineer University Works department Uni
₹20,600
Yes
30 Sept 2021
29 Dec 2017
10 Jan 2018
29 Dec 2017
8 Jan 2018
29 Dec 2017
Amount
Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm PVC insulated, copper conductor cable in surface/recessed PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sqmm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Make conduit & wire ISI Marked Havells/ Helicab / Anchor/Grandley/ L&T/HPL/ KEI and ISI Marked: Finlox /Pelican/ National Gold/ Shalimar /Ravindra) Group ‘C’
Wiring for circuit/submain wiring along with earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. (Make conduit & wire ISI Marked Havells/Helicab /Anchor/ Grandley/L&T /HPL/ KEI and ISI Marked: Finlox/Pelican/National Gold/Shalimar/ Ravindra) 2 x 6 sqmm + 1 x 6 sqmm
------------------------do------------------------- 2 x 10 sqmm + 1 x 6 sqmm
Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit if required. ISI Marked: Finlox/Pelican/ National Gold/Shalimar/ Ravindra) 20 mm
Supplying and fixing 5 amp to 32 amps rating, 240/415 volts,10 KA ‘C’ curve MCB suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required ( Indokapp/ Havells /Anchor /I.A /Legrand) Single pole
Supplying and fixing following types of Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Indokapp, Havells, anchor) 100 Amp
Supplying and fixing following ways and poles, plain/horizontal sheet steel MCB Distribution Board on surface/in recess complete with tinned copper bus bar, din bar neutral link, earth bar, detectable gland plate, interconnections including painting earthing etc. as required. (Indokapp, Havells/anchor /I.A /Legrand/HPL) 4 way (4+12),Double Door
Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/insulated conductors/strips etc. The panel shall be fabricated out of CRCA not less than 2.00 mm thick for the load bearing members and 1.6mm for doors of L.T Panels. The frame work may be Angle Iron/Channel/Bolted type construction should be arrangement for I/C/O/G. Cable termination with 2 Each. 20x5mm cu. Strip fixed all around the panel connected to 2 Each. earth bars cu-strips connected to incoming earth conductor. (Make Electric Field/ Bharti Engineers /Gupta & Friends/ Semon/ Jai maa /U.S. Electrical works) MAIN OUTDOOR /BUILDING CONTROL PANEL A. INCOMING 1. Space for 1No. 100 Amp Isolator for power load/light load of existing building 2. Space for 6 No. 32 Amp MCB’s for existing outgoing circuits. B. INDICATING PANEL The indicating panel of the incomer shall be provided with the following: i. Ammeter of required range with ASS, CT's. ii.Voltmeter of required range with VSS. Dimension of the panel = 3’ x 2’ x 1’-6”
Supply, installation, testing, commissioning of heavy duty 600 mm Sweep Exhaust fan along with shutter or additional shutter. (Make Havells, Usha, Orient, Bajaj, Anchor, crompton)
Providing/fixing following rating mirror optics high efficiency, high lumens output and uniformity, lower power consumption, low maintenance cost instant light from a cold start, high P.F, polycarbonate diffuser, milky white/transparent. Al. Housing extrusion 5800 to 6000 K, with drivers Indoor Led sports batten light luminaries similar to Lokozo CAT NO :- CAS-Z-100. (Make:- Lokozo /Philips /Havells /Wipro /Bajaj/ Surya /Crompton/Wipro) 4’ long 230 volts 100 watt
Northern Power Infra LLP
HARJEET SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .