Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-Finance INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹13.5 L+₹1.2 L (9.61%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹14.0 L+₹1.6 L (13.3%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹14.0 L+₹1.7 L (13.4%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹15.9 L+₹3.5 L (28.8%)Rejected-Finance RZF 498 MG MARG RAJ NAGAR II PALAM DELHI CANTT 110077 | NEW DELHI | DELHI | 110077 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹25.4 L
EMD Value
₹50,700
Closing Date
22 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR REPLACEMENT AND MAINTENANCE OF LT ELECTRIC SUPPLY FOR HQ CWE JCO MESS AND VARIOUS UNITS UNDER GE (U) PM DELHI CANTT 10
2023_MES_591002_1
GE(U)/PM/D-14/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
DELHI CANTT-10
MES contractor enlisted under class D category b(i) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and cate
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹50,700
Yes
17 Jun 2023
24 Apr 2023
24 May 2023
24 Apr 2023
22 May 2023
8 May 2023
Amount
Isolate/de-energize the supply to the LT Panel Board of capacity ranging from 100 Amps to 400 Amps and voltage 415 Volts/230 Volts, opening the doors/covers of the cubicle enclosure for carrying out the servicing/maintenance/repairs of the Panel Board, switch gear,MCCB, metering etc and re-fixing the same/New in place after repairs including testing and commissioning of the panel board comprising of the following:- a) Cleaning the inside switch gear chambers for removing dust, carbon and rusted surfaces including cleaning with blower . b) Check the condition of the DMC/SMC support insulators including cleaning applying Dr beck red for better IR values and replacement of insulators if required. c) Tightening up of all bus bar connections, cable connections, replace bolt, nuts wherever required. Note :- Spares will be measured and paid under relevant items of schedule..
Supply only 3 phase digital multi function meter with suitable accessories and fixing arrangements. Make :- L&T/ABB/Legrand/C&S
Supply only Voltmeter of range 0 to 500 Volts as per existing model/ capacity. Make :- L&T/Schneider/Siemens/AE/C&S
Supply only Ammeter of range 0 to 500 Volts as per existing model/ capacity Make :- L&T/Schneider/Siemens/AE/C&S
Supply only Indicator lamp neon/ LED type, RBY as per existing model/ capacity .
Supply only CT coil ratio 200/5 as per existing model/ capacity . Make :- L&T/Schneider/Siemens/AE/C&S
Supply only in repairs of aluminium busbar (40x5mm)350 Amps capacity with colour code sleeve complete all as specified and as directed.
Supply only in repair of 1.50 sqmm size FRLS, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable in proper colour coding drawn complete all as specified and as directed. (Make:- Polycab/Havells/Finolex/Gloster/Grandlay)
Supply and fixing in repair and replacement of mild steel hinges suitable for LT panel board shutters including welding, riveting complete all as specified and as directed.
Material and Labour for preparation of surface by scrapping existing painted inside and out side surfaces of LT Panel board /Feeder piller of size not more than 1.5m x 0.75m x 1.2m and applying one coat of synthetic enamel paint (1st grade quality) and one coat of heat resistant paint of approved quality and colour complete all as specified and as directed. Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Soft / loose soil including forming bottom surface etc complete all as specified and as directed.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50M and depositing where directed including spreading and levelling not exceeding 1.5 M above the starting point complete all as specified and as directed.
Supply and laying of sub Class 'B', old size bricks designation 75, for cable protection in trenches completed all as specified and directed.
Material and labour for dry river sand free from clay for cushioning of cable laid in trenches, spread , levelled and compacted completed all as specified and as directred. NOTE :- Punned thickness only be measured for payment purpose
Material and labour for Galvanised iron pipe light grade with all fitting laid in trenches / floor/ road crossing for protection of UG cables for the following sizes :- (Make:- Jindal / Tata / Prakash / Surya)
32 mm bore
50 mm bore
Taking out unserviceable/faulty/cable/service connection cable of any of any grade/type/class of any size, laying only underground cable any size and capacity including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole,making hole in wall as per requirement at site complete all as specified and as directed:- NOTE:- i) Earth work and pipes shall be measured and paid seperately under relevent items.
Supply, laying, fixing, passing through pipe or laid in trench and testing underground xlpe insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 35 Sqmm, 3.5 core complete all as specified and as directed. (Make:- Polycab/Havells/Finolex/Gloster/Grandlay/RR Kabel)
Supply, laying fixing, passing through pipe or laid in trench and testing underground xlpe insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 50 Sqmm, 3.5 core complete all as specified and as directed. (Make:- Polycab/Havells/Finolex/Gloster/Grandlay/RR Kabel)
Supply, laying fixing, passing through pipe or laid in trench and testing underground xlpe insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 70 Sqmm, 4 core complete all as specified and as directed. (Make:- Polycab/Havells/Finolex/Gloster/Grandlay/RR Kabel)
Supply, laying fixing, passing through pipe or laid in trench and testing underground xlpe insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 95 Sqmm, 4 core complete all as specified and as directed. (Make:- Polycab/Havells/Finolex/Gloster/Grandlay/RR Kabel)
Supply and fixing MCCB 4 Pole, 415 V, 63 Amps with breaking capacity 15 KA, Adjustable type complete all as specified and as directed. (Make:- Legrand / L&T / ABB / Schneider /Seimens)
Supply and fixing MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 25 KA, Adjustable type complete all as specified and as directed. (Make:- Legrand / L&T / ABB / Schneider /Seimens)
Supply and fixing MCCB 4 Pole, 415 V, 125 Amps with breaking capacity 25 KA, Adjustable type complete all as specified and directed by Engr-in-Charge (Make:- Legrand / L&T / ABB / Schneider /Seimens)
Supply and fixing MCCB 4 Pole, 415 V, 250 Amps with breaking capacity 25 KA, Adjustable type complete all as specified and as directed. (Make:- Legrand / L&T / ABB / Schneider /Seimens)
Supply and fixing MCCB 4 Pole, 415 V, 400 Amps with breaking capacity 25 KA, Adjustable type complete all as specified and as directed. (Make:- Legrand / L&T / ABB / Schneider /Seimens)
Supply and fixing Reflector adhishive tape 25 mm suitable for fixing in street light pole, colour of paint as decided by Engr in charge.
Supply and fixing Street Lights/Security light box with astronomical type timer 230 Volt AC-01 Nos, contractor TP 415 volt 25 Amps -01 Nos, MCB SPN 20A - 03 Nos, On indicator -01 Nos, Auto mannual switch - 01 Nos, and control MCB SP 3 Amps -01 No, fixed in CPRI approved sheet metal enclosure 2mm thick off size 40 x 40 x 250 cm, outdoor type, duly duly painted with power coated finish with RAL 7032 SIMEns gray structure after tank phosphating treatment and fixing arrangement by means of 25 mm x 33 MS flat clamps, nuts bolts and washers complete all as specified and as directed. Make:- Legrand/L&T/Schneider/ABB/Havells/Indoasian/Shalabh.
Supply and fixing in replacement of new generation energy saving 150W LED Flood light power coasted PDC aluminum body with toughened galss visior lumen efficency >105Lm/w. Surge protection up to 10 KV PF>.95 temp 5700K to 6500K, IP 66 including taking out old U/S flood light fitting of any type/size complete all as specified and as directed. Make :- Havells/ CG/ Bajaj/ Syska.
Taking out the old unserviceable feeder pillar box and Supply install, testing and commissioning LT Distribution Panel (CPRI approved) Cubicle type,IP-64,outdoor type confirming to IS 8623 Part I 1993 factory fabricated made out of 2 mm thick CRCA sheet & suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50x50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoint MCCBs shall have extension links of current carrying cap not less than 1.5 times teh rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links/interconnection shall colour coded sleeves. The cubicle shall have a bottom channel of size 75 x 40 mm, grouted in PCC 1:3:6 upto 40 CM height and as directed by Eng-in-charge. A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands,The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates for 4000Ampps with Breaking capacity not less then 65KA. Panel Builder should submit all Certificates before executing the job.) Make:- Universal, Switchgear, DVEPL, PSC, GM & G, ITE Gurgaon, Neptune, Hensel, Indo Asian, Standard, Havells, C&S Electric, Bhandari, Shalabh, Adhunik Switchgear, HPL, Seepl, ABB, L&T, Siemens
(a) 125 Amp FP Thermal magnetic release adjustable MCCB with a breaking capacity of 25kA with Ics=Icu 100%,along with suitable spreader links - As incomer = 01 No. Make:- L&T /Legrand/ABB/SIEMENS / SCHNEIDER
(b) Busbar TPN, Aluminum, 200 Amps - 01 Set
(c) Digital Type multi function meter to measure V, A,F,PF with suitable CTs - 01 Set (Make :- L&T/Legrand/AE/Simens
(d) LED type phase indicator lamp (RYB) = 03 Nos
(b) 63 Amp FP Thermal magnetic release adjustable MCCB with a breaking capacity of 25kA with Ics=Icu100%,alongwithsuitable spreader links - As Outgoing = 4 Nos Make :- L&T/Legrand/ABB/SIEMENS / SCHNEIDER
Material and Labour in replacement of Earthing complete with galvanised steel earth plate electrode 60cmx60cmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less' than 1.5 metres below normal ground level, connected to galvanised strip 32 x 6mm by means of bolts,nuts, check nuts and washers of copper/galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and as directed. Note : i) Earth work , GI tube for watering, funnel with wire mesh,PCC pit with RCC cover and earth test point all inclusive.ii) Earth lead beyond 7.5 m from electrode to earth terminal point/main switch board lead shall be measuredseparately. iii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
Material and Labour in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc using 32x6mm galvanised iron strip complete all as specified & as directed.
Taking down the unserviceable garden light fitting of any type and supply and fixing of integral LED bollard light 18 watt luminaries comprising of pressure dia cast aluminium housing with heat resistant glass & IP 66 protection complete all as specified & as directed. (Make:- Havells /CG/Bajaj/Surya)
Shiv Enterprises
M/s Adhikari construction co.
Surjit and Sons
MRITUNJYA ASSOCIATES
sheetal engineering
GILL ENGINEERS
BUSINESS TEK INDIA
Haryana EngineerService
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .