Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27,840Accepted-AOC 357 A NEW CHOUKSEY NAGAR LAMBAKEDA BHOPAL M P | BHOPAL | MADHYA PRADESH | L1 | Accepted-AOC Work Order Issued | |
| 2 | L2₹13.1 L+₹1.1 L (9.22%)Rejected-Finance | L2 | Rejected-Finance 2ND POSSITION | |
| 3 | L3₹13.2 L+₹1.2 L (9.98%)Rejected-Finance | L3 | Rejected-Finance 3RD POSSITION | |
| 4 | L4₹13.8 L+₹1.8 L (15.3%)Rejected-Finance | L4 | Rejected-Finance 4TH POSSITION | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹13.9 L
EMD Value
₹27,840
Closing Date
26 Dec 2019, 5:00 pmClosed
Project Engineer, Indore Division 1, Indore
G-13, First Floor, M.I.G. Colony, Behind Christian Eminent School, Indore
External electrification work for construction of 12 NGO 48 Constable Qtrs., Police Training College, Indore
2019_MPPHC_69004_1
02/2019-20
Open Tender
Electrical Works
Item Rate
30 days
Indore
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Project Engineer, MPPHIDC, Indore Division 1
₹27,840
10 Sept 2020
11 Dec 2019
27 Dec 2019
11 Dec 2019
26 Dec 2019
11 Dec 2019
Amount
Supplying and erection of HT/LT over head line single length supports complete with aligning and keeping it in truly vertical position, including digging pit of required size in all type of soil/rocks filling with 1:3:6 cement concrete of 0.60 mtr. dia. around the pole up to ground level including muffing of 0.45 mtr. dia. from ground level to 0.45 mtr. high as per specifications with 20 cm. thick base foundation in 1:4:8 cement concrete as required refilling the pit with boulder and soil as required, including painting of pole with bitumen paint below GL and two coats of red oxide and two coats of aluminium paint or synthetic enamel paint above GL as directed complete as per specification. The depth of burying of pole shall be 1/6th of the length of pole. a) H Beam 13 Mtr Long 152x152 or 150x150 mm 37.1 Kg/Mtr. weight
b) H Beam 11 Mtr Long 152x152 or 150x150 mm 37.1 Kg/Mtr. weight
Supplying and fixing of angle / channel / flat iron / RS Joist fittings for over head lines as cross arms / brackets / clamps etc. including nut bolts, required holes, welding, cutting, fabricating with necessary materials including two coats of red oxide and two coats of aluminium or synthetic enamel paint etc. as required.
Supplying and erection of GI/MS stay set complete with stay rod, anchor plate of size 300x300x5mm, thimble, stay clamp, turn buckle, bow tightener etc. with stay wire, strain insulator, nut bolts as per specifications including excavation in all type of soil/ rocks and foundation in cement concrete 1:3:6 of required size and other necessary materials complete as required as per specifications. a) GI Stay Rod 16 mm dia 1.8 m long with 7/3.15mm stay wire for LT line
b) GI Stay Rod 20 mm dia 1.8 m long with 7/3.15mm stay wire for LT line
Supplying and fixing polymer 11KV/33KV HT Disc (strain) insulator of approved make on existing pole or bracket with GI hardware and other necessary materials complete as required. a) 11 KV Strain insulator set (Hardware suitable upto Racoon conductor)
Supplying and fixing polymer 11KV / 33KV pin insulator with GI pin, of approved make on existing pole or bracket with other necessary materials complete as required. a) 11 KV Pin Insulator
Supplying and drawing ACSR/AAAC conductor of approved make with stringing making off complete with binding at existing insulator, jointing, jumpering, teeing off connecting etc. as required and clearing of obstacles (if any). a) AAAC 7/4.72 mm dia.(0.075) 80 sqmm.(RACCOON)
Supplying installing, connecting, testing and commissioning of 3 Phase, 50 Hz, 11/0.433 KV or 33/0.433 KV, Delta/Star connected, Aluminium/Copper wound, oil filled, Indoor/outdoor type, Distribution/Station transformer of accepted standard specification, 5 star catagory class, with accessories such as drain & filter valve, earthing terminals, lifting arrangements of suitable size, dehydrating breather with silica gel of suitable size, Conservator tank, air release devise, Rating & diagram plate including CI rollers, Radiators with shut off valve, Cable end boxes on HT & LT side bushings, Explosion vent with diaphragm, Off load tap changing switch, Buchholz relay, thermometer pocket with 6” dial type thermometer & OTI, wherever required complete with first filling of oil with installation on existing DP structure or foundation etc. complete as per specification. The no load and full load losses should not be more than as mentioned below. a) 200 KVA 11/.433 KV BIS CERTIFIED, ENERGY EFFICANCY (EE) LEVEL-III
b) 100 KVA 11/.433 KV BIS CERTIFIED, ENERGY EFFICANCY (EE) LEVEL-II
Providing and fixing outdoor type pole mounting weather, dust and vermin proof LT distribution box made of 14 gauge MS sheet with clamping arrangements, lockable hinged door duly painted on all sides with red oxide after antirust and corrosion treatment, two coats of synthetic enamel paints of approved make and shade, consisting of following fittings: For 100 KVA Transformer a) 200 Amps 35 KA breaking capacity TP MCCB with neutral link for incoming - 1No. b) 4 strip aluminium bus bar 225Amps supported on epoxy insulators - 1 Set c) 160/200 Amps, 415Volts DMC cutout with base for outgoing feeder with 160/200 amp HRC - 9 Nos. d) GI earth terminals- 2 Nos. e) 6 Lever Godrej Padlock with 3 keys - 1 No. f) Light point with switch and lamp holder with lamp - 1 No. Distribution box complete as above (a to F) as per MPKVVCL norms & specifications complete.
For 200 KVA Transformer a) 315 Amps 35 KA breaking capacity TP MCCB with neutral link for incoming - 1No. b) 4 strip aluminium bus bar 400Amps supported on epoxy insulators - 1 Set c) 160/200 Amps, 415Volts DMC cutout with base for outgoing feeder with 160/200 amp HRC - 9 Nos. d) GI earth terminals- 2 Nos. e) 6 Lever Godrej Padlock with 3 keys - 1 No. f) Light point with switch and lamp holder with lamp - 1 No. Distribution box complete as above (a to F) as per MPKVVCL norms & specifications complete.
Providing and fixing earthing arrangement for HT/LT poles with 8SWG GI lead of 115 turns of 50 mm dia. connection with pole / cross arm / control junction box on pole with 4 mm dia. GI lead through 20 mm dia A class GI protection pipe of 2.5 m length duly bend, packing of charcoal powder and salt as per specification including excavation of pit in all type of soil / rock, refilling of pit by black cotton soil etc. complete.
Supplying, laying, testing and commissioning of XLPE insulated and PVC sheathed heavy duty power cable confirming to IS 7098/Part-I/88 with latest amendments, 1100 volts grade armoured cable of approved make with aluminium solid / stranded conductor. The cable shall be laid in air/in existing pipe/in existing cable trench/on existing cable tray with clamp as required as per specifications including providing of metal/PVC cable identification tags at both ends and every 10 Mtr. length of cable with inscriptions there on. Un armoured cable 1 core 150 Sq.mm
Un armoured cable 1 core 300 Sq.mm
Un armoured cable 1 core 70 Sq.mm
Supplying and fixing 2 ply 12 gauge barbed wire around the existing HT/LT electric pole for safety measures as per IE rules including all stapples and all other necessary materials complete as required as per specifications.
Providing and fixing enamelled danger caution plate/board on existing electric poles or wherever required of size 250x200 mm, made of 1.6mm thick mild steel sheet and vitreous enamelled white, with latest, figures and the conventional skull and cross-bones in signal red colour (as per IS-5-1978 with latest amendment) on the front side. The rear side of the plate shall also be enamelled. The corner of the plate shall be rounded off with required material such as screws, wires clamps, nut bolts etc. complete. a) 11 KV
Commissioning of D P structure over existing support with panting in an approved manner consisting of following :- (A) D. C. cross arm with clamp, nuts & bolts (100 x 50 mm only ) - 1 set (B) 11 KV D. O. fuse unit, lightings arrangement and AB swich mounting channel with nuts and bolts (75 x 40 mm channel) of require - 1 set (C) 11 KV Polymer AB swich single phase 600amp. as required - 1 set (D) Transformer mounting cross arms / channels with clamps nuts and bolts (100 x 50 mm channel ) - 1 set (E) 11KV Polymer Do fuse unit ( set of 3 no.) - 1 set (F) Transformer clamping set (50x50x6 mm angle ) with nuts and bolts etc. complete - 1 set (G) Transformer belting set (50x50x6 mm angle) with nuts and bolts etc. complete - 1 set (H) 11 kv polymer lightning arrestor ( 9 kv gapless type ( 5 kA ) for DTR ) ( set of 3 No.) - 1 set (I) supplying , fixing, testing and connecting of complete earting set of 7 No. as per MPMKVVC.Ltd. circular No DS CO M/EZ/ WS/1516/DT 17-03-2008 and approved dwring for transformer sub - station including all materials GI Strips, GI wires, Charcoal power salt excavation of pits in all types of soils/rocks etc. as required complete .( 1 set of 7 Nos.) -1 set (J) Distribution panel mounting channel and clamp with nuts & bolts etc. (75 x 40 mm channel ) 1 – set (K) Supplying , fixing, testing and Commissioning of DTR Meter LT. 3 phase 4 wire 3X240 volts I 3 A. LTCT operated 3 phase 4 wire 3x63, 5 volts , LB = 5 amps lmax 10 amp trivector meter glass of accuracy 0.5s DLMS complaint category a meter along with GSM ( GPRS compactable ) modems with box i/c all accessories and formalities as per MPMKVVCL as required. or 3P 4w - 5A LTCT class 5s DLMS compliant type c. rs - 232. Port box MRI LTCT 100/5A i/c meter box with TTB etc as required.(High precision thread through coposite meter upto 100 KVA) (L) SF & T and HT tape for covering LT bushing i/c windings and blower hitting complete minimum 30 meter or as required. D.P. Structure Complete as above (A to L)
Supplying and drawing AAA conductor Rabbit for jumpering /guard wire/earth wire/bearer wire 18.62 mm sq (4.87mm dia/6 swg)conductor of approved make with stringing making of complete with binding at existing insulator, jointing, jumpering, teeing off connecting etc. as required and clearing of obstacles.
Providing and fixing chain link/Wire Mess fencing sourriding existing DTR S/S finicing (total 37 running meter maximum) of 6’ height with chain link/Wire Mess fencing on MS Angle (50X50X6) mm support 7 nos. 7’ height with following feature. (A) Upper & lower frame of fencing will be of MS angle (25X25X4) mm size. (B) MS strip of (25X5) mm flat shall be used fro cross bracing of fencing (C) Double Gate (2nos. 2.5’X5’) of MS angle (50X50X6)mm. bracing of 25X5 mm flat with mesh & locking arrangement.Complete as above ( A to C) – one job.
B L JAIN
Om Shiv Associates
Pankaj Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .