Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC 13 11 MOTILAL GUPTA ROAD KOLKATA 700 008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.0 L+₹53,158.60 (4.62%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L2 | Rejected-Finance L2 | |
| 3 | L3₹18.4 L+₹6.9 L (59.7%)Rejected-Finance 1 C NEPAL BHATTACHARJEE STREET KALIGHAT KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹23,000
Closing Date
27 Aug 2025, 12:00 pmClosed
The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. BlockI (1st Floor) Writers Buildings, Kolkata 700 001
Temporary Electrical installation work in respect of Durga Puja Idol Immersion Ceremony 2025 at Red Road Part E Car Parking Lights.
2025_WBPWD_889671_1
WBPWD/EE-KED/eNIQ-25Q/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Maidan
Please refer Tender documents.
5 documents required · 5 mandatory
₹23,000
O/O The Executive Engineer Kolkata Electrical Divi
25 Sept 2025
11 Aug 2025
29 Aug 2025
11 Aug 2025
27 Aug 2025
22 Aug 2025
21 Aug 2025
Amount
Providing and installation on Hire basis 440V TPN MS with rewirable fuse/HRC fuse fixed on angle iron frame incl providing necy inter connection wiring, 2 nos of earthing attachment and dismantling as directed by EIC after the programme (For 03 Days)
Providing and installation on hire basis 440 V , 100Amp 4 Pole MCCB as incomer with 6-32 Amp or 16 Amp per way, 6 Way TPNMCBDB with all arrangement in a outdoor type pillar box incl interconnection wire with proper socketing and dismantling as directed by EIC after the programme (For 03 Days)
Providing and installation on hire basis 440 V , 63 Amp 4 Pole MCB as incomer with 16 Amp per way, 6 Way TPNMCBDB with all arrangement in a outdoor type pillar box incl interconnection with proper socketing and dismantling as directed by EIC after the programme (For 03 Days)
Providing and installation on hire basis 500 V, 200 A on load changeover switch incl interconnection with proper socketing and dismantling as directed by EIC after the programme.(For 03 Days)
Providing on hire basis main wiring with 1.1 KV grade Aluminium Conductor PVC / XLPE armoured cable of following size including laying in trench (at least 230 mm below ground) including socketing and necessary finishing as required and dismantling the same and mending good the damages.(For 03 Days)
4C X 16 Sqmm AL cable
4C X 50 Sqmm AL cable
Supply and drawing of the following sizes pvc insulated and unsheathed multistranded Al/copper wire on hire basis with carrying cost at the sites and dismantling as per direction of EIC including socketing,glanding and necessary finishing as required(For 03 Days)
7/0.064(7/16) Single Core
7/0.029 (7/20) single core
Providing and Fixing on hire basis following LED Flood light fittings complete with bracket & clamp on the pole incl. accessories and dismantling as directed by EIC after the programme(For 03 Days)
Minimum 200 Watt LED Flood fittings.(Crompton/Philips/Bajaj/Nordusk)
Supplying & providing on hire basis 240V A. C. 600 mm / 24" sweep Air Circulater Pedestal Fan with 3 pin plug top and dismantling the same(For 03 Days)
Supply & Errection on hire basis 9 mtrs steel tublar pole average depth of 1.5 mtr below the ground incl. Earthing and dismantling & mending good the damages as directed by E.I.C.(For 03 Days)
Supplying & providing on Hire basis 1 no Seperate 6 amp plug and Switch with 150X100X65mm MS/TW switch Board including necy. wiring in 3 x1.5 sq mm single core PVC insulated, unsheathed, multistrand copper wire (avg. Length 5 mtr) & dismantling the same after completion of the program.(For 03 Days)
Supply & providing on hire basis Earthing with 50 mm dia GI pipe 2.5 to 3 mtrs long and 6/8 SWG GI wire with galvanized nut and boltss washer etc. below the ground level & dismantling the same(For 03 Days)
Providing on hire basis suitable Public Address System with operator for the program days.The amplifier should be of minimum 400Watt for police announcement purpose with horns minimun 2 Numbers, 2 number speaker,microphone 1 number with stand, inclusive all necessary connection as required as per direction of EIC.
Supplying & Providing on hire basis 415V, 3 Phase CPCB approved soundless diesel generator set for prime/standby operation with mobil incl. transportation ,one operator & appropriate size of cable upto 120 Mtrs including necessary interconnection, socketing & dismantling as directed by EIC after the program. If the DGs are not placed at site on time , pro rata rate will be reduced from bill.
25 KVA-8 Sets
40 KVA-1 Sets
25 KVA-8 Sets
40 KVA-1 Sets
Deployment of 3 no. Skilled Electrician, & 3 no. Helper per shift per day (i.e. Total 9 nos Electrician & 9 nos Helper per day for 24 Hrs) for carring out all kind of EI maintenance, DG operations & proper upkeepment and preventing any unwanted incidents like theft, willful damage etc. (no additional charge will be paid for any unwanted incidents)
Transportation charges of above materials from co's godown to site and return back to co. godown.
Cost for constructing a temporary rain shed to protect electrical panels, main switches, distribution boards (DBs), changeover switches, and related equipment from rainwater. The structure will be built using bamboo and covered with either polyethylene tarpaulin or aluminum/tin, with size as required.
18 % GST on the total amount from SL no 1 to 16.
Supply and pouring of HSD for the hired DG set incl. handing cost.(The measurement will be done after considering all technical aspect,orginal invoice & log book).
Special Terms and conditions for Temporary E.I. Work - 1) Earthing should conform to IS specification. Earth Continuity wire should not be broken / Jointed. Single Earth continuity wire should be used from Earth Bus-Bar to the installation. 2) All 3ɸ Electrical Panel Should be earthed by two nos. of separate earthing and 1ɸ panel should be earthed by one no earthing. 3) MCB / Rewirable Fuse type Distrubution Board should be installed with proper Trip Current setting / fuse wires. However, MCB type DBs are preferable. 4) No Part of the Electrical Circuit in the pandal / Structure shall be within 12 inches of any decorative cloth / paper. 5) Ordinary Flexible wires should not be used. Only new PVC insulated & sheathed wires (Bearing ISI mark) or PVC insulated wires of FRLS (Fire Resistant Low Smoke) type (ISI Marked) are allowed. 6) All cable ends should be properly socketed. 7) All joints shall be made with porceline insulated connectors. Twisted & lapped joints shall be avoided. But Joints are strictly not allowed in the dias. 8) Cables / Wires should run along outside the Dias. 9) Ceiling fan (s) / Electrical fittings must not be suspended from the ceiling of Dias. Pedestal fans are not allowed on the Dias. However, Pedestal fans may be installed outside dias, but the body of the fan must be properly earthed.
10) T/L fittings shall be of box type (Indoor commercial type). Any kind of open type fittings must be avoided. 11) Each A.C. Machine should be connected with a separate circuit and earthing should be provided by separate single earth contunuity wire from Earth Bus-bar. 12) P.A. System and Microphone shoud be earthed. 13) Sufficient quantity of Fire Extinguishers and First Aid Box should be provided. 14) If the DGs are not placed at site on time pro rata rate will be reduced from bill. 15) The guarding /security arrangement of all the hired products /installation has to be made by the successful bidder at his/their own cost and responsibility. No additional charge will be paid for any unwanted incidents like theft, damage due to natural calamities or any other reasons whatsoever. 16) During entire hiring period any fault to the hired installation shall be rectified/faulty items replaced, at the cost of agency. Suitable man power for attending and rectification/replacement of damaged items has to be provided by the agency at their own cost. Rectification time is 1 hour for the event day and upto 2hrs for other days. 17) A test certificate cum safety certificate is to be provided by the agency, duly signed by the Supervisor of the agency after completion of installation. 18) A performance guarantee of hired DG sets and AC machines has to be provided by the agency after completion.
GHANASHYAM ELECTRIC STORES (BID ID -6877854)
SHREE GANESH ENTERPRISE (BID ID -6877307)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .