| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹33.9 L+₹2.6 L (8.23%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹34.4 L+₹3.1 L (9.89%)Rejected-Finance 3 3430 NICHOLSON ROAD KASHMERE GATE DELHI DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹34.4 L+₹3.1 L (10.0%)Rejected-Finance 21 GREEN ENCLAVE SULLAR PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹34.7 L+₹3.4 L (10.8%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
3 Sept 2024, 6:00 pmClosed
LT COL SANDEEP KUMAR
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIR/MAINT TO E/M INSTALLATION AND REPAIR TO APPROACH PATH, COMPOUND WALLS DRAIN ETC IN OFFRS ACCN UNDER AGE B/R-II AT PATIALA MIL STN
2024_MES_664060_1
GE (N)/TOKEN-33/2024-2025
Open Tender
Civil Works
Item Rate
70000 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NORTH PATIALA
₹70,000
Yes
15 Oct 2024
4 Jul 2024
5 Sept 2024
4 Jul 2024
3 Sept 2024
20 Jul 2024
Amount
Taking down cement plaster on brick walls built in cement mortar including raking out joints and concrete surfaces as in wall or ceiling etc. including hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L for Cement plastering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement including WPC as per manufacturer instructions complete all as specified and directed. Note : WPC shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed.
M & L for 10mm thick cement plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
M & L for 5 mm thick cement plastering in cement mortar 1:3 on fair faces of concrete ceiling surfaces finished even & smooth without using extra cement complete all as specified and directed.
M&L for preparing new surfaces of wall and applyting three coat of white wash complete all as specified and directed.
M&L for preparing new surfaces of ceiling and applying three coat of white wash on ceiling surfaces complete all as specified and directed.
M&L for preparing old surfaces of wall and applyting two coat of white wash complete all as specified and directed.
M&L for preparing old surfaces of ceiling and applying two coat of white wash on ceiling surfaces complete all as specified and directed.
Complete removal of existing treatment of any type/description such as distempering work, internal emulsion etc from internal surfaces of walls & ceiling with mechanical means/grinder complete all as specified and directed.
M & L for Applying 02 coats of interior emulsion paint (light shade) by using roller to wall surfaces over & including a coat of interior wall primer as recommended for under coat by manufacturer of interior emulsion over a coat of including acrylic 1.5 to 2.5mm thick wall care putty complete all as specified and directed.
M & L for Applying 02 coats of interior emulsion paint (white shade) to ceiling surfaces over & including a coat of interior wall primer as recommended for under coat by manufacturer of interior emulsion over a coat of including acrylic 1.5 to 2.5mm thick wall care putty complete all as specified and directed.
M & L for Applying 02 coats of exterior emulsion paint (light shade) by using roller/brush to external walls/RCC surfaces/soffits of chajjas/roofprojections/ cantilevers/ balcony etc surfaces over & including a coat of exterior wall primer as recommended for under coat by manufacturer of exterior emulsion over a coat of including acrylic1.5 to 2.5mm thick wall care putty complete all as specified and directed.
Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed.
M&L for Brick work with sub class 'B', old size bricks, designation 100, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description, in ground floor not exceeding 150mm thick above or below ground level compete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate as in sub base flooring compete all as specified and as directed.
M&L for rubber moulded coloured chequered tiles 30cm x 30cm x 22mm thick with grey cement and pigment, set jointed and pointed in neat cement slurry as in floor including 20 mm thick screed bed in 1:4 complete all as specified and directed.
M&L machine pressed rubber moulded ISI marked precast cement concrete interlocking paver block any shape and size and of coloured tiles confirming to IS-15658-2006 of 60mm thickness M-35 grade complete all as specified and directed.
M & L filling of interstices with fine sand laid over and including 25 mm thick (compacted) fine sieved sand cushioning of size and shape as decided by GE complete all as specified and as directed.
M&L for 20mm thick granite (of any type) (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L cement concrete type B1 1:2:4 (20 mm graded stone aggregate) in roof kerbs, paddings or mud stops rounded or chamfered complete all as specified and directed.
Dismantling of post or struts (wood or RCC) any section incl taking embeded portion and making good distrubed ground embeded in concrete complete all as specifieid and as directed.
Dismantling of barbed wire fencing in any size and poisition complete all as specified and directed.
Excavating in post holes in soft/ loose soil (or similar holes) each n exc. 0.5 cum , getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts ; angle posts and struts in fencing including cutting tops to shape as directed, driliing holes, notching for wire, etc: flat iron fillets (for securing wire mesh etc). including all necessary drilling, bolting or riveting, etc. and similar work complete all as specified and directed.
S&F chain link fencing comprising plain GI wire mesh 3.15mm dia and average size of mesh 100 x 100mm , including link wire nails, straining bolts etc and provision of binding wire as specified after taking out old unserviceable mesh wire of any description complete all as specified and as directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square not, exc 5cm but n exc 10 cm of dia 10mm complete all as specified and directed.
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coat synthetic enamel paint over a coat of red oxide primer complete, all as speciifed and directed.
M&L for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed by Engr-In-Charge.
M&L for mild steel frame work as in gate, doors including cast iron ornament and designs etc complete, all as specified and directed. Note : Gate will be hanged on support of pintle hinges complete all as specified and directed.
Dismantling of structural steel work as in door chowkhats , shutters guard bars and similar items but excluding framed truss complete all as specified and directed.
S&F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes complete all as specified and directed.
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick as in covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick as in covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for providing and Laying Premium (1st) quality straight edge, ceramic tiles WA value between 3% to 6% , flexural strength greater than 22N/mm², scratch resistance on mohs scale greater than 4 and crazing resistance of 2 cycles in area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floor, 8 to 10 mm thick in floors etc. in any shade and design/pattern of light & dark tiles etc as approved matching with wall tiles, set & jointed in neat cement slurry & pointed in matching colored polymer cement based grout to match over complete all as specified and directed by Engr-in-Charge.
M&L for Brick work (Except bricks) with sub class 'B', old size bricks, designation 100, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. Note: Bricks retrieved from item no 14 shall be reused after proper cleaning.
M&L for Preparation of plastered surfaces of walls etc. and applying two coat of cement base paint complete all as specified and directed by Engr-in-Charge.
Material and labour for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed in cement mortar 1:3 including making joints with or without grooves (thickness ofjoint except at sharp curves shall not be more than 5mm) including making drainage opening where ever required complete all as directed by Engr-in-charge.
AR CONSTRUCTIONS (BID ID -3079617)
ANIL KUMAR AND CO (BID ID -3078406)
Buttar Construction Co. (BID ID -3077908)
rkkataria and sons (BID ID -3078777)
DELTA CONSTRUCTION CO (BID ID -3078696)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .