| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC 186 B DIAMOND HARBOUR ROAD KOLKATA 700 060 | KOLKATA | WEST BENGAL | 700060 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹45.3 L+₹85,972.78 (1.94%)Rejected-Finance VILL JETHIA NATUN PARA PO JETHIA HALISAHAR PIN 743135 | 24 PARAGANAS NORTH | WEST BENGAL | 743135 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹45.9 L+₹1.5 L (3.42%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.0 L+₹1.6 L (3.54%)Rejected-Finance 7 11 1 BROJONATH LAHIRI BISHNUPUR SOUTH 24 PGS WEST BENGAL 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹46.8 L+₹2.4 L (5.40%)Rejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
28 Mar 2024, 6:00 pmClosed
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/ MAINT OF CERTAIN B/R AND E/M WORKS AT INSTALLATIONS OF MES IB, AREA DRAINAGE, OFFICERS MESS, AOI AND HORSE RIDING UNDER GE(FW) KOLKATA
2024_MES_645693_1
8232/E8
Open Tender
Civil Works
Item Rate
180 days
GE (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹78,000
31 Mar 2024
8 Mar 2024
30 Mar 2024
8 Mar 2024
28 Mar 2024
21 Mar 2024
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, all as specified and as directed .
M&L for hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
M&L for 100mm thick cement concrete type B-1, 1:2:4 using 20mm graded aggregate in floors finishing cement concrete surface even and smooth using extra cement complete all as specified and directed.
Material & Labour complete removal of old surface of walls applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over all as specified and directed.
M&L Preparing old decorated Plaster Surfaces of Wall and applying two Coat of oil bound distemper complete all as specified and as directed.
Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water all as directed..
M&L 10 mm thick rendering in cement mortar (1:6) to brick or concrete wall surfaces, finished even and smooth without using extra cement all as specified and as directed .
M&L 15mm thick cement plaster on wall /concrete surfaces without using extra cement finishing fair and even in CM 1:4 including necessary scaffolding complete all as directed.
M&L Preparing new plastering Surfaces of Wall and applying two Coats of oil bound distemper complete all as specified and as directed.
M&L Preparing new plastering Surfaces of Wall applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) n. exc 1.5 sqm each complete all as specified and as directed ..
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed.
S&F powder coated anodised aluminium doors frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified.
S&F powder coated anodised aluminium window and ventilator shutters, side hung type with sash bars, aluminium section weighing 0.55 Kg/metre including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, anodised aluminum fittings such as suitable peg stays, hinges and handles-02Nos etc with 4mm thick tinted/frosted glass ordinary quality as per manufactures instruction complete all as specified.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and as directed.
S&F 4mm thick ordinary quality sheet glass/frosted glass and glazing with oil putty in square n.exc. 0.5 Sqm in each pane complete all as directed.
Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed..
Supply only integral water proofing compound (ISI grade only)
Dismantling posts or struts (wood, steel or RCC) any section ,including taking out embedded portion and making good disturbed ground post embedded in concrete, complete all as specified and as directed.
Dismantling of fencing, wire mesh any type complete all directed.
Excavating in post hole (or similar hole) each nexc0.5 cum getting out, returing, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 M and making good surface in soft and loose soil complete all as specified and as directed..
Material and labour for providing Plain Cement Concrete (1:4:8) type D2 using 40 mm graded aggregate as in foundation, filling and mass concrete all as specified and directed.
S & F MS angle, flats etc independently fixed without connecting plates etc but ordinary length conforming to FE-410-W(Gde-E-250)quality A as in fencing posts including drilling holes for nuts and bolts and similar work complete all as specified and as directed.
M&L Mild Steel Screw Bolts (machine made) 5mm to 10mm diameter of neck and length of bolt exc 5 Cm and not exc. 10 Cm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and as directed.
S & F MS 10 mm dia round bar and fixed independently to angle iron for chain link fencing cut to length, bend to shape required, complete all as specified and as directed
S&F 4mm dia PVC coated galvanised mild steel chain link fencing of mesh size 50x50mm fixed with straining bolts including line wire any mesh size and type to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified and as directed.
M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed.
M&L for Fe 410 -W (Gde E- 250) quality A Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for. complete all as directed.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris complete all as specified and as directed.
M&L for 40 mm thick cement concrete type B-0, 1:2:4 using 12.5mm graded aggregate in sub bases of floors complete all as specified and directed.
M & L for screed bed 15 mm thick (average) plaster on concrete surfaces in CM (1:3) on roof, mixed with water proofing compound and finishing the surface even and smooth without using extra cement all as specified and directed (Water proofing compound shall be measured and paid separately).
M&L Water Proofing Treatment on existing cleaned RCC Roof with the following Specifications and Manufacturer's instructions, complete all as specified and as directed :- (a) Rendering 10mm thick in Cement Mortar 1:4, finished even and smooth and cured for 07 days by Ponding of water over Roof. (b) Preparing fully dried plastered surface as per IS:3067-1966, for further treatment. (c) Applying Bitumen Primer conforming to IS-3384-1986 over the Cleaned Plastered Surface @ 0.3 Litre per Sqm. (d) Applying a layer of APP based Polymeric Membrance; 3.0mm thick (minimum) weighing 3.50 Kilogram per Square Metre (reinforced) with Polyster Non Woven Fabric weighing not less than 160 Grams per Square Metre by Torch application. The overlaps shall be minimum 100mm on the Transverse direction and 75mm on Longitudinal direction. (e) Applying one coat of Aluminium Paint @ 0.10 Litre per Sqm over APP based Polymeric Membrane.
S&F in repair Steel rolling shutters (Thickness of laths 1.25mm), with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type etc complete all as spd and as directed.
Repair to Steel rolling shutters any thickness size and shape with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in same position as indicated, complete: push pull or manual type etc., complete all and as directed.
Dismantling AC corrugated roof sheets as in roof coverings including AC ridge complete.
M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
M&L Preparing old Steel Surfaces of any description not otherwise described over 10 Cm width or girth and applying two Coat of Synthetic Enamel Paint, complete all as specified and as directed.
Dismantling of boarding, any description, fixed in any position with screws etc all as directed.
M&L for providing and fixing Gypsum Board 600x600x12mm thick in ceiling fixed with screw in anodised aluminium snap grid frame work for false ceiling as per manufacturers instructions with Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L 25 mm thick pre polished coloured chequred tiles of size 400X400 jointed and pointed in neat cement slurry with white or coloured to match including over 20 mm thick screed bed CM 1:6 completed all as directed.
Dismantling of floor hearth, wall tiling incl cement mortar bedding( but not backing) removing of serviceable tiles to store and rubbish off the premises complete all as specified.
M&L joint free coloured tiles 7-8mm thick area of each tiles exc 0.11 sqm but n.exc0.18sqm (400X400X7-8mm),as in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bedding in CM 1:6.complete all as specified and directed.
S&F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and over laid backing coat 10mm thick plaster CM 1:4 complete all as specified and directed.
SCHEDULE A PARTII(E/M PORTION) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants , regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc complete all as specified and directed.
M & L for point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC casing & caping / PVC conduit terminated in PVC block 50 mm deep (sunken) for fixing of switches, sockets, fan regulators etc (PVC box of required size will be measured and paid under relevant item) for the following: -
One light point or one fan point or bell point controlled by one switch or bell push
One 3/5 pin socket outlet, 5 Amp independent
One 3/5 pin socket outlet, 5 Amp on the same board with other switches
M & L for point wiring with FRLSH grade PVC insulated unsheathed multistranded copper conductor cables of 2.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 2.5 sqmm size through and including PVC casing & caping terminated in and including PVC block 50 mm deep (sunken) for fixing of switches/ sockets for one 3 pin socket outlet, 15 Amps, independent.
M & L for concealed point wiring with FRLSH grade PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC conduit terminated in modular switch boards for fixing of switches, sockets, fan regulators etc for the following [Note: - Modular switch boards shall be measured and paid separately]: -
One light point or one fan point controlled by one switch
One 3/5 pin socket outlet, 5 Amp independent
One 3/5 pin socket outlet, 5 Amp on the same board with other switches
S & F Modular Switch 1 way 6 A, 1 module complete all as specified and directed.
S & F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular Fan step regulator, 120 watt, 2 module complete all as specified and directed.
S & F Modular Bell push 6A, 1 module complete all as specified and directed.
S & F Modular Blank plate, 1 module complete all as specified and directed.
S & F Modular type White cover plate with frame 1 module complete all as specified and directed.
S & F Modular type White cover plate with frame 2 module complete all as specified and directed.
S & F Modular type White cover plate with frame 3 module complete all as specified and directed.
S & F Modular type White cover plate with frame 4 module complete all as specified and directed.
S & F Modular type White cover plate with frame 6 module complete all as specified and directed.
S & F Modular type White cover plate with frame 8 module complete all as specified and directed.
S & F Modular type White cover plate with frame 12 module complete all as specified and directed.
S & F Modular type Metal Flush box 1/2 module complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module complete all as specified and directed.
S & F Modular type Metal Flush box 6 module complete all as specified and directed.
S & F Modular type Metal Flush box 8 module complete all as specified and directed.
S & F Modular type Metal Flush box 12 module complete all as specified and directed.
S & F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 5 Amp complete all as specified and directed.
S & F Switch socket combination 2 in 1, 5 Amp flush type complete all as specified and directed.
S & F Bell push, flush type, 5 amp complete all as specified and directed.
S & F Switch socket combination 5A/ 16A, 5 in 1flush type complete all as specified and directed.
S & F Switch piano, flush type single pole, one way 15 Amp complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and directed.
S & F Bell , AC, 230 Volts, single pole complete all as specified and directed.
S & F Musical Call Bell complete all as specified and directed.
S & F stepped type electronic fan regulator flush type complete all as specified and directed.
S & F Ceiling rose, 3 terminal PVC insulated body complete all as specified and directed.
S & F in repair Modular Switch 1 way 6 A, 1 module complete all as specified and directed.
S & F in repair Modular Switch 1 way 16 A, 1 module complete all as specified and directed.
S & F in repair Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F in repair Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F in repair Fan step regulator, 120 watt, 2 module complete all as specified and directed.
Taking down carefully unserviceable sub main wiring of any type and size alongwith conduit/batten with complete accessories, etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M & L for sub main wiring with 4 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type all as directed.
All as per Srl. Item No. 94 above but with 2 run of 6.0 Sqmm cable and 6.0 Sqmm as earth continuity conductor.
All as per Srl. Item No. 94 above but with 2 run of 4.0 Sqmm cable and 4.0 Sqmm as earth continuity conductor.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site complete all as specified and directed.
S&F SPN DB, IP 43 protection, double door (Premium Quality), 240 volts, 4 way, with 200 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN004DD / LEGRAND, Cat No: 507610 / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04 / HAGER, Cat No: VYS04D)
S&F TPN & Neutral DB, IP 43 protection, double door (Premium Quality), 240 volts, 4 way, with 200 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN004DD / LEGRAND, Cat No: 507610 / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04 / HAGER, Cat No: VYS04D)
apply and Fix, Double Door, Sheet Metal Enclosure for DBs (Premium Quality), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN008DD / LEGRAND, Cat No: 507611 /ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08 / HAGER, Cat No: VYS08D)
Supply and fixing in repair PVC casing/caping of size 25 mm with all accessories all as directed by Engr-in- charge .
Supply and fixing in repair PVC casing/caping of size 20 mm with all accessories all as directed by Engr-in- charge .
S&F GI in repair tubing medium grade of size 15 mm dia incl painting and making hole for extension of fan hook in high roof ceiling complete all as specified.
S & F in repair clamp with buckle for hanging ceiling fan including nut and bolts complete set all as specified and directed.
S & F in repair MCB Four pole, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. Make :Cat No 408702 of Legrand or equivalent make of Havells / L & T
S & F in repair MCB 'C' series single pole and Neural 32 Amps, breaking capacity 10KA, complete all as specified and directed. Cat No 408587-95 of Legrand or equivalent make of Havells / L & T
S & F in repair MCB 'C' series single pole 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed Cat No 408587-95,of Legrand or equivalent make of Havells / L & T.
S&F in repair Exhaust fan heavy duty AC single Phase 230 V / 240V 50 Hz of size 230 mm sweep, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. Make Bajaj/Usha/Crompton or equivalent as specified and directed.
S&F Exhaust fan in repair heavy duty AC single Phase 230 V / 240V 50 Hz of size 250 mm sweep, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. Make Bajaj/Usha/Crompton or equivalent as specified and directed
S&F Exhaust fan in repair heavy duty AC single Phase 230 V / 240V 50 Hz of size 300 mm sweep, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. Make Bajaj/Usha/Crompton or equivalent as specified and directed
Supply and fixing Cable tray of size 100 x 100 mm with all accessories complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987 and dismantling/taking out of existing unsv earthing, complete all as specified and directed.
BASU AND CO
M A ENTERPRISES
SK CONSTRUCTION SYNDICATE & ENGG CO
ARATI TRADING CO
JAY MA TARA TRADERS
SANTOSH INTERNATIONAL
M/S L.R.ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .