Loading…
Loading…
Tender Value
₹87.1 L
EMD Value
₹1.7 L
Closing Date
18 Jun 2026, 6:00 pm
SE PHED Circle Banswara
SE PHED Circle Banswara
PROPOSAL FOR WATER SUPPLY SCHEME OF EKLAVAY MODAL RESIDENTIAL SCHOOL AT VILLAGE PADOLA BLOCK ANANDPURI WITH ONE YEAR DEFECT LIABILITY PERIOD
2026_PHCJA_564773_1
NIT 02 2026 -27
Open Tender
Civil Works - Water Works
SE PHED Circle Banswara
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
EE PHED
₹1.7 L
Yes
4 Jun 2026
4 Jun 2026
19 Jun 2026
4 Jun 2026
18 Jun 2026
4 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.
b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.
c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.
d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.
e) Conducting successfully hydro test and water tightness test as per I.S. code.
f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.
g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container.
i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.
j) Providing and fixing water level indicator (float type). | - | - | - | - |
| 2 | OHSR Near EMRS Campus 100KL & 18 m staging | - | PER LTR | 27.53 | - |
| 3 | Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. | - | - | - | - |
| 4 | 100 mm Dia | - | Per mtr | 2,259 | - |
| 5 | STAR DELTA STARTER 11.0 KW (15.0 HP) - : For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G- MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 25A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (9-13A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) | - | - | - | - |
| 6 | above 10 HP and Up to 15 HP | - | each | 66,938 | - |
| 7 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. | - | - | - | - |
| 8 | 3 core 6.0 Sq.mm | - | RMT | 283 | - |
| 9 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. | - | - | - | - |
| 10 | 16.0 Sq.mm, 4 core | - | RMT | 234 | - |