| 1 | L1₹1.3 CrAccepted-AOC NO 167 1 MUTHUGOUNDENPALAYAM RING ROAD KUMARAPALAYAM ERODE 638 104 | ERODE | TAMIL NADU | 638104 | ₹1.3 Cr | L1 | Accepted-AOC Your tender accepted by the Chief Engineer (City)/TNHB |
| 2 | L2₹1.4 CrRejected-Finance | ₹1.4 Cr | L2 | Rejected-Finance The tenderer quoted higher rate |
| 3 | Rejected-Technical | - | - | Rejected-Technical Pre qualification evaluation committee has rejected vide Boards Memo.No.ES/E3/7455/2020SF_3, Dt.24.02.2026 |
| 4 | Rejected-Technical 16 5 KUMARASAMY STREET KALAIMAGAL SCHOOL ROAD ERODE | - | - | Rejected-Technical Pre qualification evaluation committee has rejected vide Boards Memo.No.ES/E3/7455/2020SF_3, Dt.24.02.2026 |
| Sl No | Description | Qty | Unit | Sabari Designs L2 | BLUELEAF PROJECTS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00Supply of Variable Refrigerant Flow (VRF) Out Door Unit Air conditioning System Inverter Scroll Compressor Modular VRF Out Door Unit, The proposed Variable Refrigerant Volume (VRV) / Variable Refrigerant Flow (VRF) system should be with necessary Indoor & Outdoor Units. The system needs to be selected for working at longer pipe length to place all the Outdoor Units at the terrace and run copper pipes inside each floor by entering through one shaft. Supply of VRV / VRF Condensing Units of following capacities for city and capable of working at Peak Temperature of Chennai City. The refrigerant used shall be Eco-Friendly R 410A only. The system shall have necessary Single Phase Preventer and designed to run even at phase reversal conditions. The Compressor may be single or multiple but it should be of 100% Inverter Only (Make: Blustar/Daikin/Hitachi/Equivalent) | |||||
| 1.013rd Floor, 5th Floor & 6th Floor | |||||
| 1.02 | 20 HP | 2 | Nos | 5,20,000 ₹10.4 L | 4,65,000 ₹9.3 L |
| 1.03 | 18 HP | 3 | Nos | 4,48,000 ₹13.4 L | 4,00,000 ₹12 L |
| 1.044th Floor, 5th Floor & 6th Floor | |||||
| 1.05 | 14 HP | 2 | Nos | 3,85,000 ₹7.7 L | 3,35,000 ₹6.7 L |
| 1.06 | 16 HP | 2 | Nos | 4,00,000 ₹8 L | 3,50,000 ₹7 L |
| 2.00Installation Charge of Variable Refrigerant Flow (VRF) Out Door Unit from 3rd Floor to 6th Floor | |||||
| 2.013rd Floor, 5th Floor & 6th Floor | |||||
| 2.02 | 20 HP | 2 | Nos | 48,000 ₹96,000 | 60,000 ₹1.2 L |
Tender Value
₹1.4 Cr
EMD Value
₹81,000
Closing Date
19 Jan 2026, 11:00 amClosed
The Superintending Engineer, Project Circle (City)
The Superintending Engineer, Project Circle (City), Tamil Nadu Housing Board, C-48, 2nd Avenue Anna Nagar, Chennai-40.
Providing Centralized Air Conditioning Arrangement from 3rd floor to 6th floor (A-Wing Staff Sections) in TNHB Head Office in Pocket 6 (2 B.F plus G.F plus 7 Floors) at CIT Nagar 1st Main Road, Mambalam Village and Taluk, Chennai
2026_TNHB_638928_1
TNHB/PC(CITY)/12/2025-26
Open Tender
Civil Works - Others
60 days
CIT Nagar
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹81,000
9 Mar 2026
5 Jan 2026
19 Jan 2026
5 Jan 2026
19 Jan 2026
5 Jan 2026
3rd Floor, 5th Floor & 6th Floor
4th Floor, 5th Floor & 6th Floor
Installation Charge of Variable Refrigerant Flow (VRF) Out Door Unit from 3rd Floor to 6th Floor
3rd Floor, 5th Floor & 6th Floor
4th Floor, 5th Floor & 6th Floor
Supply and installation of Twinning Kits for Variable Refrigerant Flow (VRF) Out Door Unit from 3rd Floor to 6th Floor, Installation Cost inclusive of lifting, leading positioning and alignment along with necessary anti vibration rubber pads required fasteners etc.,
Supply of Indoor Cassette Units with necessary 4 way grill /micro-controller, drain pump , provision for fresh air Connection etc. of following configuration
1.5 TR Capacity (Four Way Cassette Unit)
2.0 TR Capacity (Four Way Cassette Unit)
3.0 TR Capacity (Four Way Cassette Unit)
4.0 TR Capacity (Four Way Cassette Unit)
Supply and Installation of Refnuts for the Indoor Cassette Units with necessary 4 way grill /micro-controller, drain pump , provision for fresh air Connection etc. of following configuration
Supply of 19 G Copper Refrigerant Piping with 19mm thick Closed Cell rubber nitrile insulation for gas line and 13mm for liquid line of following sizes- Inclusive of necessary Supports with Ladder type cable tray as per standard practices. For Pipes Exposed to Atmosphere - Treatment of Piping with Woven Glass Cloth , ~ 100 gsm, finished in U/V Treated, pigmented Epoxy for Outdoor Piping, as per code. necessary pipe sizing to be done by successful bidder.
3rd Floor to 6th Floor
Installation, Testing and Commissioning of 19 G Copper Refrigerant Piping with 19mm thick Closed Cell rubber nitrile insulation for gas line and 13mm for liquid line of following sizes- Inclusive of necessary Supports with Ladder type cable tray as per standard practices. For Pipes Exposed to Atmosphere - Treatment of Piping with Woven Glass Cloth , ~ 100 gsm, finished in U/V Treated, pigmented Epoxy for Outdoor Piping, as per code. necessary pipe sizing to be done by successful bidder.
3rd Floor to 6th Floor
Supply, Installation, Testing & Commissioning of Interconnecting copper shielded control cabling between IDU's & ODU's. The cabling shall be well supported / tied up with the ref line. In PVC conduits of Black colour with Junction boxes required as per the indoor unit locations.
3rd Floor to 6th Floor
Supply Installation Testing and Commissioning of UPVC Pipes
32mm dia UPVC Pipe
25mm dia UPVC Pipe
Supply and Installation of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height
Supplying and Filling REFRIGERANT GAS - R410A
Nitrogen Pressure testing in 3 stages for the above copper piping,VRV indoor and outdoor units System
Making Core Cutting in slabs / beams / retaining walls and any other R.C members to any dia & depth by using diamond drilling machine with tolerance for any type of inserts, anchor fasteners etc. Rate shall include for sealing the gaps between RC surface with GP 2 grout and inserts with fire retardant grouting material as per manufactures specification. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, scaffolding, stagging, tools and plants, fuel, curing, cleaning, testing, consumables, fasteners, screws, adhesives, and fixing materials etc., and complying with relevant standard specification, as directed by the Engineer-in-charge.
Supply of TNEB LTCT 110KW EB Metering Panel ( Copper Bus Bar & MRT CT Coill & 250A TPN Enclouser Box)
Supply of 200A ATS Panel : 200A 4P ATS - 1 Nos. Contractor 200A - 2 Nos. - Make - Socotech & L&T - Make , EB R,Y,B & DG - R,Y,B, EB - On, DG - On, Load - On - Lamp - L&T - Make
Supplying laying and installation of 240 Sq.mm Alu. Armoured UG cable from Pillar Box to LTCT Panel
Supplying laying and installation of 70 Sq.mm Alu. Armoured UG cable from Pillar Box to LTCT Panel
Hydraulic Door Closer of various sizes of approved quality using Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer with Double Speed Adjustment (with ISI Monogram)
UPVC Windows : UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Supply and Fixing of Vertical TPN Distribution Boards (with MCCB Incomer); Double Door; IP43, as per IS 8623 III; Impact resistance IK09; Frame MCCB Incomer & Single Phase/Three Phase MCBs as Outgoing (for power loads exceeding 100A) HIGHER END
Supply and Installation of L.T. 1100V PVC Copper Armoured cable with ISI mark
4 core 16sq.mm PVC copper cable
4 core 25sq.mm PVC copper cable
Run off main with 2 wire of 4 sqmm copper PVC insulated unsheathed single core cable in fully concealled conduit pipe
Providing and laying in position, Standardised Concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456- 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
Providing Form Work : Rate for small quantities like RCC Square or Rectangular column top and bottom slab of boxing, sill slab, sunshade with necessary facia etc. complete
Supply and Installation of RCCB / ELCB (Four Pole) 100A/125A FP RCBO 30 mA
Supply and Installation of MCBs 100A Four Pole MCB
Supply and Installation of MCBs Single Pole 6A to 32A, 10KA
Providing Earthing Station as per IS 3043
Run off 8 SWG, GI wire for Earth Connection
Supplying, fixing, Connecting and commissioning of 25 AMPS Metal clad socket (Superior variety) combined with 25AMPS SP MCB in Manufactures mount box fixed flush with the wall including cost of material, necessary interconnections, etc., on suitable angle
Supply of UG armoured UG Cable 3 1/2 core 50mm and laying
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.13 MB
TenderdocumentforcentralizedAC.pdf
Tender Documents • 1.13 MB
BOQ_764686.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid