Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-Finance | ₹23.6 L | L1 | Accepted-Finance BID PART-1 QUALIFIED |
| 2 | L2₹29.9 L+₹6.2 L (26.3%)Accepted-Finance VILL KULCHOURA BUDAUN UTTAR PRADESH | SOUTH | DELHI | 110025 | ₹29.9 L+₹6.2 L (26.3%) | L2 | Accepted-Finance BID PART-1 QUALIFIED |
| 3 | L3₹36.7 L+₹13.0 L (55.1%)Accepted-Finance 00 RL QR NO 388 B KALIBARI COLONY ALIPURDUAR JN JALPAIGURI WEST BENGAL 736123 | ALIPURDUAR | WEST BENGAL | 736123 | ₹36.7 L+₹13.0 L (55.1%) | L3 | Accepted-Finance BID PART-1 QUALIFIED |
| Sl No | Description | Qty | Unit | M/S M.G ENTERPRISES L2 | M/S TIWARI TRADING COMPANY L1 | SHIV TRADERS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Cage fencing of 250/400/630 KVA T/F Plinth mounted transformer in Town/Rural areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation. | 10 | Nos. | 22,485 ₹2,24,850 Lowest | 25,000 ₹2,50,000 | 25,985 ₹2,59,850 |
| 2.00 | Pipe Earthing (Netural & Body) of power/distribution Transformers (By boring of 4 inch diameter upto water lavel, 40 mm diameter A Class GI pipe is inserted to a depth of upto water lavel and a holed pipe of 1.5m length is inserted at the bottom, Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work contractor will provide all material, manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE). | 142 | Job | 19,450 ₹27,61,900 | 14,888 ₹21,14,096 Lowest | 23,985 ₹34,05,870 |
| 3.00Note:-All Item Rate filling with GST by the firm | ||||||
Tender Value
₹31.2 L
EMD Value
₹32,000
Closing Date
15 Jun 2026, 3:00 pmClosed
SE, EDC, BDN
BUDAUN
11/EDCB/2026-27
2026_MVVNL_1154940_1
11/EDCB/2026-27
Open Tender
Electrical Works
Item Rate
30 days
BUDAUN
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹3,540
A/c No. 1243002100806171, IFSC Code - PUNB0124300
₹32,000
29 Jun 2026
30 May 2026
16 Jun 2026
30 May 2026
15 Jun 2026
30 May 2026
30 May 2026 - 15 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Cage fencing of 250/400/630 KVA T/F Plinth mounted transformer in Town/Rural areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation. | 10 | Nos. | - | - |
| 2 | Pipe Earthing (Netural & Body) of power/distribution Transformers (By boring of 4 inch diameter upto water lavel, 40 mm diameter A Class GI pipe is inserted to a depth of upto water lavel and a holed pipe of 1.5m length is inserted at the bottom, Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work contractor will provide all material, manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE). | 142 | Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.08 MB
Tender_form11.pdf
Tender Documents • 0.91 MB
BOQ_2163388.xls
BOQ • 0.26 MB
date1011extension1.pdf
PDF • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .