Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹44.8 L+₹5.2 L (13.1%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹44.8 L+₹5.2 L (13.1%)Rejected-Finance 20 A 2ND FLOOR BLOCK C RAJEEV NAGAR BEGUMPUR DELHI 110086 | NORTH WEST | DELHI | 110086 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹44.9 L+₹5.3 L (13.3%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹45.2 L+₹5.5 L (13.9%)Rejected-Finance 2788 FOURTH FLOOR GALI RAJPUTANA ARYA PURA SABZI MANDI NEW DELHI KAMLA NAGAR NORTH DELHI DELHI 110007 UDYAM DL 01 0057966 | NORTH DELHI | DELHI | 110007 | L5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹95,100
Closing Date
9 Feb 2024, 6:00 pmClosed
GE NASIRABAD
Garrison Engineer, Military Engineer Services, Nasirabad, Pin - 305601
PROVN OF SENTRY POST AT GATE NO 04, URINAL POINT NEAR GATE NO 06 AND SPECIAL REPAIR TO BLDG NO. P-31 (01 TO 08) OR MD ACCN AT TOWER COLONY OF RKT REGT (PINAKA) IN NASIRABAD MIL STN
2024_MES_638192_1
8404/E8
Open Tender
Civil Works
Item Rate
183 days
GE Nasirabad
MES Contractor enlisted as Class D and above and category a i having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
Yes
GE NASIRABAD
₹95,100
Yes
22 Feb 2024
19 Jan 2024
12 Feb 2024
19 Jan 2024
9 Feb 2024
2 Feb 2024
19 Jan 2024 - 2 Feb 2024
Amount
Surface excavation n.exc 15cm deep and getting out in any type of soil complete all as specified and directed.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation, .manhole, cesspits etc.and getting out in hard/dense soil, complete all as specified & directed.
Returning, fillings in including spreading, levelling, watering and well ramming in layers, n.exc 25cm thick in soil complete all as specified and directed.
Removing of excavated soils, not exc 50mtr and depositing where directed at a level n. exc 1.50mtr above the starting point complete all as specified and directed.
M & L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified & directed.
M & L for brocken stone boulders Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified & directed.
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L for mild steel TMT bars of 6mm to 8mm dia and over, in stirrups , spacers and boinders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L for RCC M-25 (design mix) using 20mm graded aggregates as in roof beams, lintel beams/bands, cantilevers, bressummers, lintels over 1.5m span, chajjas etc complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to sides and soffits of floor or roof beams, soffits of lintel beams/ bands, chajjas, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., flat surfaces of concrete ,surface is required to be fair finished. complete all as specified and as directed by the Engineer-in-Charge
M & L for RCC M-25 (design mix) using 20mm graded aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), flat surfaces of concrete, surface is required to be fair finished. complete all as specified and as directed by the Engineer-in-Charge
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, as roughed finished surface of concrete complete all as specified and as directed.
M&L 15mm thick rendering in cement mortar (1:4) mixed with water proofing compound @ 3 % by weight of cement on other than fair faces of brick / stone masonary surfaces, finished even and smooth without using extra cement, complete all as specified and directed (WPC measured and paid separately) complete all as specified and directed.
M&L for rendering in cement mortar (1:6), 10mm thick on other than fair faces of brick work / stone masonary surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 10 mm thick in cement plaster 1:4 as in ceiling surfaces finished even and smooth (without using exta cement) complete all as specified & directed.
S&F stop/angle valve 15mm bore cast copper alloy, chromium plated, fancy type with long crutch or butterfly handle screwed down high pressure screwed both ends for iron pipe complete all as specified & directed.
Taking down cement or cement lime plaster on stone/brick wall, ceiling incl. Raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M& L for rendering in cement mortar (1:6), 15mm thick on stone masonary surfaces finished fair and even complete all as specified and directed.
M & L for RCC M-20 (nominal mix) using 20mm type B-1, 1:2:4 graded aggregates as in roof beams, lintel beams/bands, cantilevers, bressummers, lintels over 1.5m span, chajjas etc complete all as specified and as directed by the Engineer-in-Charge.
M & L for RCC M-20 (nominal mix) using 20mm type B-1, 1:2:4 gradedaggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
Dubbing out average 10mm thick in CM 1:4 on irregular faces of walls or concrete chajjas etc complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and apply two coats of oil bound distemper over a coat of 1mm thick wall care putty, complete all as specified and directed. Make : JK/Birla
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M&L for preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed
M&L for complete removal of existing treatment of old plastered surface of wall and applying two coat of distemper oil emulsion / oil bound distemper over coat of 1mm thick average thick wall putty incl priming coat complete all as specified and directed.
M & L preparation old decorated surfaces of walls and providing two coat of cement base paint incl alkali-resistant priming coat, complete all as specified and directed.
M&L for rough cast plaster over 10mm thick cement plaster in cement mortar 1:4 on stone / brick masonary wall surfaces complete all as specified and directed.
M&L for newly plastered surfaces two coats of cement base paint over one coat of cement based primer on plastered/concrete surfaces of walls incl preparation of surfaces complete all as specified and directed.
Dismantling loose /disintegrated portion of RCC Chajjas, bend shelves, beams balconies and similar work at any position or any height and dobbing out with PCC 1:1.5:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished required shape including applying anti corrosive paint on exposed surfaces of reinforcement and provision of necessary supporting form work and including 10mm thick plastering in CM 1:4, finished fair and even, complete all as specified and directed.
Demolition of cement concrete (unreinforeced) in floors and paving n.exc 15cm thickness (above or below ground level) complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 20-25mm thick over 15mm thick screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed 10mm thick in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the smooth of the slab incl rubbing & polishing complete all as specified and directed.
M&L cement concrete type D-2, 1:4:8 (40 mm graded aggregate), 75 mm thick, complete all as specified and directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed
M&L for PCC 1:2:4 Type B-1 (using 20mm stone crushed agg.) as in rounded or chamfered on edges in any description complete all as specified
M & L for bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5 Kg per sq m per coat and applying plythene film black, 50 micron laid in floors complete over sunken floor slab and embedded in side wall / covered fillet complete all as specified and directed. Note :- Supply of water proofing compound shall be measured and paid separately.
Supply only water proofing compound ISI Marked complete all as specified and directed.
M & L PCC (1:5:10) type E-2 using 40mm graded crushed stone aggregate as in sunken floors complete all as specified and directed.
M&L 100mm thick cement concrete type D-2 1:4:8 (40mm graded stone aggregate ) as in sub base complete all as specified and directed.
M&L glazed ceramic coloured tiles, size 450 mm X 300 mm, 6-7 mm thick on vertical surfaces of wall such as dados, skirting etc set & jointed in neat slurry and pointed in white or colour cement to match over 10 mm thick screed plaster in CM 1:4 complete all as specified and directed
M & L for Non-skid Ceramic tiles 7 to 8 mm thick ( square /Rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured in white or coloured cement to match with tile laid over and including screed bed or bedding layer of 15 mm thick in CM (1:6) complete all as specified and directed.
M & L for Non-skid Ceramic tiles 7 to 8 mm thick ( square /Rectangular) area of each tile exceeding 0.18 sqm but not exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured in white or coloured cement to match with tile laid over and including screed bed or bedding layer of 15 mm thick in CM (1:6) complete all as specified and directed.
All as per the item No 44.00 above but as in skirting 10 mm screed plaster in CM 1:4 complete all as specified.
Demolition of stone/ brick masonry built in cement or cement lime mortar as in portion ordered and directed.
M&L for Random Rubble stone walling uncourses, built in CM (1:6) complete all as specified and directed.
ditto all as item No-47.00 above but except stone complete all as specified and directed.
M&L for old size brick work with flyash bricks straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for brick work with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, hammer dressing with maximum depression on face from straight edge held against the dressed surface n. exc 20mm as specified and directed
Demolition of Stone slabs & tiles of any description or thickness in floors , aprons etc, complete all as specified and directed.
M&L for granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win- dow-cills, cooking plat-forms and like in cement mortar (1:4) including pointing in white cement (1:2) us-ing marble dust with admix-ture of pigment to match with shade of granited polishing complete all as specified & directed.
M&L for 75 mm thick PCC 1:3:6 type C2 using (20 mm graded crushed stone aggregate) as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3) complete all as specified and directed
Taking down old unserviceable shower rose & S&F brass chromium plated shower rose of 125 mm size with swivel joints, incl . Fixing to steel pipe or union of 15mm bore,Mixing valve including three joints to steel pipes or unions and plugging and screwing to walls complete all as specified and directed.
Taking out old unserviceable water closet (squatt pattern) and S & F Vitreous China, Squatting pan Orissa pattern size 580 x 440mm, white with integral foot rests (excluding flushing cistern and flush pipe ) with Vitreous China ‘P’ or ‘S’ trap, front or back inlet including connection to trap and to flushing pipe, anti syphonage pipe , including PCC (1:2:4) type B-1 for fixing of WC and making good the floor to match the existing complete all as specified and directed.
Taking down old unserviceable flushing cistern S&F PVC valveless syphonic action type low level flushing cistern, 10 Ltrs capacity . White, with inlet ball valve, float, handle with 32mm PVC flush pipe, fixed on walls by driling holes and using PVC rawl plug of suitable size complete all as specified and directed.
Taking down old unserviceable PVC connection and S & F PVC connection, heavy duty 15 mm bore, 45 cm long with two Nos PTMT nuts at both ends of approved quality complete all as specified and directed
S&F in repair Soap dish any type, fixed to plugs with chromium plated brass screws embedded in the wall complete all as specified and directed
Taking out old un serviceable tubular towel rail & S&F tubular towel rail aluminium anodised 20mm dia 'D' type 60cm long between flanges complete all as specified and directed
S&F tubular towel rail aluminium anodised 20mm dia 'D' type 60cm long between flanges complete all as specified and directed.
S&F in repairs Chromium plated concealed stop cock 15 mm dia screwed down light pressure screwed both ends for iron pipe or for union complete all as specified and directed
S&F Chromium plated concealed stop cock 15 mm dia screwed down light pressure screwed both ends for iron pipe or for union complete all as specified and directed
S&F in repairs Chromium plated Angle stop cock 15 mm dia screwed down light pressure screwed both ends for iron pipe or for union complete all as specified and directed
S&F in repairs Chromium plated bib taps, with capstan heads, screwed down for iron pipe or for brass ferrule & fixed for 15 mm bore pipe complete all as specified & directed.
S & F for sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; in-cluding bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connect-ing union to rigid UPVC waste pipe bent to shape & fixed to wall with bracket overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed by the Engineer-in-Charge
Taking down old wooden plate rack and S&F stainless steel plate rack made of 0.50mm thick of over all size 920mm x 785 mm x 255 mm and weight not less than 7.00 Kg each of approved quality complete all as specified and directed.
Taking up or down steel tubing and connection 15 mm bore and removing the same from site/keeping aside for reuse complete all as specified and directed.
All as per srl item No-69.00 above but 20 mm bore
All as per srl item No-69.00 above but 25 mm bore
S & F water tubing 15 mm bore, medium weight, ISI marked galvanized with all fittings and fixed to walls, ceiling or laid in floors complete all as specified and directed.
All as per srl item No- 72.00 above but 20 mm bore
All as per srl item No-72.00 above but 25 mm bore
M & L for fixing only 15mm bore old GI tubing to walls, ceiling or laid on floor including necessary cleanig, cutting, screwing and new fittings such as elbow, Tee, union, socket, reducer etc.
All as per srl item No-75.00 above but 20 mm bore
All as per srl item No-75.00 above but 25 mm bore
S&F PVC (SWR) Nahani/Floor trap 75 mm outlet,with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) as in repairs.complete all as specified and directed
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc 1.50 sqm each and removing from site complete all as spd & directed and making good disturbed surface of walls in cement mortar (1:3) all as specified and directed
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm and n.exc 4.00 Sqm each and removing from site complete and making good disturbed surfaces of wall in CM (1:3) all as specified and directed.
M & L for rolled mild steel work angle iron as in door frame (Chowkhats) & cooler stand including provn of 12mm dia deformed bar welded horizontally to bottom of frame confirming to Fe-410 or Fe-250 including preparing back of chowkhat and applying two coats tar and sanding newly tarred surfaces with clean sharp sand complete all as specified and directed.
S&F for Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour sheet PVC Sheet rinforced with M.S square tube,fixing in opening as per specification & Drawing complete all as specified and directed.
S & F factory made solid pannel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded. sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawings on page 146 of SSR Part - II 2004 complete all as specified and directed.
S & F second class HW Hollock/Bonsum/Sal 35mm thick, factory made, plain framed, paneled shutter (Three panels) with panels of 9mm thick BWP grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive conforming to IS-710. The size of rails & style shall be as per IS-1003 (part-I) kiln seasoned as per IS-1141 & chemically pressure treated as per IS-401 complete all as per specified and directed.
S & F for 2nd class HW 35 mm thick, gauged and skeleton shutters (Three Panels), factory made open rebated and prepare to receive glass, gauge etc (with sash bar), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. Size of members of shutter shall be as specified in SSR 2009 Part-I, section 8 clause Member shall be kiln seasoned as per IS-1141 & chemically pressure treated as per IS-401 complete all as specified and directed.
Blank
S & F Steel window/ventilator factory made, made out of MS hollow section 79mm x 39mmx1.6mm thick frame with double shutter (glazed & wiregauged shutters) made out of Z section using flush butt welding and tennon riveting all as per IS 1038/83, dobby hinges shall be provided to both shutters, Locking arrangements as per sample approval by GE, provided with knob, 10mm MS square bars in grill, Z section handle 100mm size and 150mm long hook & eye welded to frame and shutter, four Nos lugs welded to frame inculding necessary flat iron beading for securing wire gauge etc including holes, cutting holes for hold fast and making good in PCC 1:2:4 type B-1, and plaster with finishes to match the existing surfaces, including 02 coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and directed. Note : Wire mesh and sheet glass shall be measured & paid separately under respective items.
S & F 300mm long aluminium alloy, anodised, sliding door bolts with hasps, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S & F extruded aluminium handle fabricated type, anodised 150mm size conforming to IS complete all as specified and directed.
S&F aluminium, anodised, barrel tower bolt of extruded section, ISI marked, 150 mm long complete all as specified and directed.
S & F 125mm single action spring hinges,mild steel with steel wire spring, stove enamelled black, complete all as specified and directed.
S&F 100mm stainless steel hinges, ISI marked complete all as specified and directed
S&F mild steel butt hinges, medium weight, cold rolled, ISI marked type B-21 of size 100 mm, complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed with wire staples complete all as specified and directed.
M & L for preparation of new wooden surface over 10cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surface over 10cm width or grith & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as specified and directed
S&F 3.00 mm thick sheet glass, ordinary / figured quality & glazing with oil putty not exc 0.50 Sqm each pane complete all as specified and directed
S&F 3mm thick figured glass, ordinary quality, 3mm thick fixed with oil putty size of glass not exc 0.50 sqm in each pane, complete all as specified and directed.
S&F in repair fancy type 20mm dia stainless steel curtain rods powder coated fixed to bracket completed all as spd & directed.
S&F decorative type knobs with bracket of MS powder coated fixing at end of pelmet rod complete al as specified and directed.
Dismantling of existing unserviceable water tank of any description capacity exc 250 Ltr but n.exc 500trs capacity each complete all as specified and directed
Supply and fixing 250 Litre capacity rotational moulded polyethylene water storage tanks ISI Marked (cylindrical vertical with closed top) , hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
Supply and fixing 500 Litre capacity rotational moulded polyethylene water storage tanks ISI Marked (cylindrical vertical with closed top) , hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
S&F ball valves PTMT high pressure with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe, 20mm bore compete (Minimum weight 210 gm) complete all as specified and directed.
S&F in repairs gun metal globe or gate valve, wheel head cast copper alloy screwed down light pressure with crutch or butterfly handle screwed both ends for iron pipe or for union 25 mm dia, ISI marked complete all as specified and directed.
M&L 50 mm thick sand stone slabs; set and jointed over joists etc. in CM 1:4 as in base of water tank and M&L 25 mm thick PCC 1:2:4 type B-0 (using 12.5mm stone crushed agg.) finished concrete surfaces even & smooth complete all as specified and directed
Taking down existing unservicable treatment of any description including cement plaster/conctrete any thickness from roof surface cleaning of roof surfaces and and preparing it for further treatment and removing rubbish from the site up to 50 mtrs complete all as specified and directed.
M&L for screeding 10mm thick in CM 1:4 on fair faces of RCC /stone patti roof surface finished fair & even without using extra cement even complete all as spescified and directed.
M & L for five layered roof treatment with APP modified polymeric water proofing membrane, 2.1 mm thick having centre core not less than 100 micron high molecular high density polythylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 micron HMHDPE film weight not less than 3 Kg/ Sqm applied with bonding material using belown type bitumen conforming to IS-702 Grade 85/25 @ 1.20 Kg/ Sqm over bitumen primer conforming to IS- 3384 @ 0.40 Kg/ Sqm with final coat of bonding bitumen grade 85/25 @ 1.20 Kg/ Sqm over APP membrane with all overlaps complete all as specified and directed.
Material and labour for 40mm thick (average consolidated thickness) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate laid in slope as in padding, finished even and smooth on existing slope including provision of 'V' shaped groove 6mm wide and 10mm deep at 1.20 metre interval or parts thereof, both ways on top of PCC padding and filled with mastic bitumen of (1:1) proportion complete all as specified and directed.
M&L for coved fillet in PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate at junction of roof & parapet wall and other vertical surfaces and surface painted with a hot paving bitumen grade 30/40 conforming to IS-73 @0.70 Kg/Sqm over a coat of bituminous primer conforming to IS-3384 @ 0.30 Ltr Sqm complete all as specified and directed
Blank
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in surface channel and drain etc complete all as specified.
Taking down CI pipe 100/75 mm fixed wall and floor etc including accessories complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 75mm bore PVC(SWR) bends with oval access door of any radius complete all as specified and directed.
S & F110mm bore PVC(SWR) bends with oval access door of any radius complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with oval access door complete all as specified and directed
S & F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with oval access door complete all as specified and directed
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc, including removal to store complete all as specified and directed.
S&F in repairs 110mm dia PVC rain water pipe fixed on wall under walls as spout incl. complete all as specified and directed.
S&F only stack clamp out of 50mm by 5mm flat iron and 16 mm dia round iron stays fixed to pipe of bore 100mm complete all as specified.
Dismantling posts or struts,Chimney (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed by engineer in charge.
S&F vitreous china white wash basins, including waste pipe, brackets, and connecting pipe Table top basin complete all as specified and directed. Make: Jaquar KUS WHT 35901/ Kerovit Mazer KB1086 or equivalent
S&F vitreous china urinal half stall type incl connecting pipe, spreader, flushing valve and flush/waste pipe fixed to wall complete. Make : Parryware C0580 with C8123 or Jaguar URS WHT 132530
Taking down old unserviceable WHB and S&F wash hand basin vitreous china white /colour flat size 550 x 400mm fixed including waste coupling, waste pipe ,complete all as specified and directed. (Make :- Cat Part No - 4653 Prayag & equivalent of Johnson, Cera and Parryeare)
S&F in repairs pillar taps fancy type cast copper allloy capston headed, chromium plated, screwed down, high pressure with long screwed shank and fly nut, screwed for 15mm bore iron pipe complete all as specified and directed by engineer in charge.
Blank
Fabrication & fitting of kitchen with cabinet/shelves & wardrobe/cupboard made out of 18mm thick (one side decorative lamination & other side balancing lamination) PVC sheet with piano hinges including providing cabinet for keeping baskets / cutlery baskket with handles/door shutters complete all as specified and directed. Note :- PVC sheet, fitting & fixture will be measured and paid separately as supply only.
Supply only in repairs 18mm thick (one side decorative lamination & other side baancing lamination) solid PVC board with cement solvent adhesive for shutter/kitchen cabinet / cup board/partition wall/ wall cabinet complete all as specified and directed. Make :- Raj shree or equivalent as approved by GE.
Supply only soft close clip on hinge bright finish complete all as specified & directed.
Supply only 125 mm dia oval shape brass handle fancy type bright finish complete all as specified & directed.
Supply only in repair stainless steel basket (plain) of approved quality of size 520 X 485 X 100mm complete all as spepcified and directed. Make :- Godrej SS 304
Supply only in repair stainless steel plate basket of approved quality of size 520 X 485 X 150mm complete all as spepcified and directed. Make :- Godrej SS 304
Supply only basket / trolly channel 50cm long extruded MS galvanised over roller complete all as spepcified and directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, holders, regulators, sockets etc., removing materials from site and making good disturbed surface of walls, floors etc. complete all as specified and directed
Disconnecting unserviceable sub main wiring/service connection of any size and including conduit of any type and accessories and removing from site and making good the disturbed surfaces complete all as specified and directed
Taking down MCB DB's complete with MCB's/Isolator etc removing materials from site and making good disturbed surface of walls, floors etc. complete all as specified and directed
M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed in and including non metallic rigid PVC concealed conduit 20 mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including one green colour cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Engr-in-Charge of following. Make of wire: KEI/HPL/Havells, Conduit: Anchor/National/Bajaj Plast
All as per item No. 141.00 here-in-before but One light point controlled by one, one way switch.
All as per item No. 141.00 here-in-before but One ceiling fan/exhaust fan point controlled by one, one way switch.
All as per item No. 141.00 here-in-before but One three pin 5 Amp socket on same board with other switches.
All as per item No. 141.00 here-in-before but One 3 pin 5 Amp socket on independent board.
All as per item No. 141.00 here-in-before but One light point controlled by two Nos two way switch.
All as per item No. 141.04 here-in-before but with 2.5 Sqmm, for one 5 pin 5/15 Amp socket on independent board including 2.5 Sqmm stranded copper conductor (FRLS) PVC insulated green in colour as continous earth conductor connected to common earth complete all as specified and directed
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed multistranded (FRLS) copper conductor cable of size 6.00 Sqmm LT, 1100 volts grade, drawn through and including 25 mm dia or higher PVC non metallic concealed conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor complete all as specified and directed
Supply and fixing of switch piano type, flush button single pole, one way 5 Amps, complete all as specified and directed. Make : Panasonic Anchor / Standard / Havells
S&F switch piano 1 way 6/10 amps, complete all specified and directed .
S&F switch piano 1 way 16 amps, complete all specified and directed .
S&F Socket 6 Amp 2/3 pin combined complete all specified and directed. Make : Panasonic Anchor / Standard / Havells Reo
S&F Socket 6/16 Amp 2/3 pin combined complete all specified and directed. Make : Panasonic Anchor / Standard / Havells Reo
S&F switch piano flush type 15 amps, single pole one way 240 volts complete all specified and directed . Make : Panasonic Anchor / Standard / Havells
S&F switch piano flush type 5 amps, single pole two way 240 volts complete all specified and directed . Make : Panasonic Anchor / Standard / Havells
S&F bell push piano flush type 5 Amp complete all specified and directed . Make : Panasonic Anchor / Standard / Havells
S&F Socket outlet 3 Pin 5/6 Amp flush type complete all specified and directed. Make : Panasonic Anchor / Standard / Havells Reo
Supply and fixing of socket out let 2 in 1, multipurpose 3 pin 15/16 Amp flush type complete all, as specified & directed. Make : Panasonic Anchor / Standard / Havells Reo
S&F ceiling fan regulator electronic flush , steped (four step) 230 Volts AC complete all specified and directed .
S&F ceiling rose surface bakelite 3 terminals 63.5 x 17 mm complete all specified and directed .
Supply and fixing of door bell electric, ding dong type, AC 230 volts, single phase , complete all as specified and directed. Make : Panasonic Anchor / Standard / Havells Reo
S&F of lamp holder PVC/polycarbonate type with back plate complete all as specified and directed. Make : Panasonic Anchor / Standard / Havells Reo
S&F box type LED tube light fitting in acrylic linear tube 1x 20 watt, 230V complete with bipin holders, LED power driver, connector block, and LED Tube rod 20 watt complete all as speciied and directed by Engr-in-Charge.
S&F LED tube light fitting in acrylic linear tube (1x 18 watt),230V for single LED tube light including 1 x 18 W LED retrofit bar professional CW 6500 K cover channel, bipin holders,LED power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed. Make:- Bajaj , Havells, Crompton
S&F Wall mounted decorative luminaire fitting suitalble for LED lamp B-22 base 9 watt complete all as specified and directed by Engr-in-Charge.
S&F LED lamp 10 watt suitable for 230 volts, 50 Hz B-22 Base complete all as specified and directed.
S&F LED bulk head luminaire 1x 10 W bulk, IP 65 protection complete with all accessories and including connecting up with three core copper conductor cable complete all as specified and directed.
S&F testing and commissioning energy saving street light luminaire 35 watt LED, pressure die cast housing with epoxy powder coated with colour finish and prismatic poly carbonate coverlic cover complete with individual LED lences and complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp and street light bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed
Supply and fixing street light bracket made of 32 mm GI pipe, 1.2 mtr length fixed with two Nos of clamp, nut and bolts complete all as specified and directed.
Disconnecting and taking down existing electric meter and refixing the same electric meter, connecting, testing and sealing properly and making good disturbed surface of walls etc. complete all as specified and directed
Taking down existing ceiling fan, dismantling blades and refixing after cleaning incl conecting up with three core flexible cable from ceiling rose to fan complete all as specified and directed
S&F of MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door IP-42 DB's , made out of sheet steel enclosure, recessed type, factory made powder coated 8 way, 240 volts suitable for housing MCB's complete all as specified and directed. Make: Legrand/Schneider/Seimens Note: MCB DB and MCB SP/SPN will be of same make.
S&F of MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door IP-43 DB's , made out of sheet steel enclosure, recessed type, factory made powder coated 4 way, 240 volts suitable for housing MCB's complete all as specified and directed. Make: Legrand/Schneider/Seimens Note: MCB DB and MCB SP/SPN will be of same make.
S&F of MCB distribution board TPN 4 way, 415 volts, double door, with 200 Amps rated bus bar, neutral bar with shrouds, earth bar, IP-43 , made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCBs as incomer and outgoing complete all as specified and directed. Make: Legrand/Schneider/Seimens Note: MCB DB and MCB SP/SPN will be of same make.
S & F of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' curve complete all as specified and directed. Make : Legrand (DX-3), Schneider (Acti-09), Siemens ( Betagard)
S & F of MCB SPN, 240 volt, 32 Amp capacity, 10 KA , 'C' curve complete all as specified and directed. Make : Legrand (DX-3), Schneider (Acti-09), Siemens (Betagard)
S&F of MCB TPN, 415 volt, 63 Amp capacity,10 KA, 'C' curve complete all as specified and directed. Make : Legrand (DX-3), Schneider (Acti-09), Siemens (Betagard)
S&F of MCB SPN, 240 volt, 63 Amp capacity,10 KA, 'C' curve complete all as specified and directed. Make : Legrand (DX-3), Schneider (Acti-09), Siemens (Betagard)
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 15mm bore and water pipe 20 mm bore GI med grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2009 incl dismantling of old unsv existing earthing complete all as specified and directed.
Supply and fixing storage type electric Water heater (Geyser) single phase 230 volts, stainless steel tank, vertical type oc capacity 25 Ltr, BEE 5 star rated connecting inlet/outlet/vent pipes, electric/earth connections , mounting bolts, nuts and carrying out testing for proper functioning including wiriting MES No with black enemel paint complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single phase, 230V of size 300 mm sweep with blades and frame and louvers suitable for 230 volts, single phase 50 Hz AC Supply, connecting with three core flexible copper cable including making hole for fixing of fan and making good the distrubed surface of wall complete all as specified and directed.
S&F wall fan of size 300 mm sweep, Speed upto 2100 RPM, Air Delivery 90 CMM, 230/240 volts including connecting with three core flexible copper wire from ceiling rose to connector of fan complete all as specified and directed. Make :- Havells, Bajaj, Usha
Supply and fix ventilation fan, steel body AC single phase, 230V of size 250 mm sweep with blades and frame and louvers shutter suitable for 230 volts, single phase 50 Hz AC Supply, connecting with three core flexible copper cable including making hole for fixing of fan and making good the distrubed surface of wall complete all as specified and directed.
Supply and laying including jointing, testing or fixing or passing through pipe, trench or duct commissioning and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade size 25 sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
Supply and laying including jointing, testing or fixing or passing through pipe, trench or duct commissioning and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade size 10 sqmm, 2 core complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
Supply and fixing tubes light grade GI tubing 40 mm dia with all fitting laid in trenches complete all as specified and directed.
Supply and fixing tubes medium grade GI tubing 20 mm dia with all fitting laid in trenches, fixed on pole/on wall for cable protection complete all as specified and directed.
S&F Stop valve gun-metal, glove or gate valves with iron wheel head, screwed both ends for GI pipes of size 20mm dia complete all as specified and directed.
kirtiman traders
Shree Sai Ram Enterprises
TANISHQ ENTERPRISES
M/s AKASH CONSTRUCTION CO.
MITTAL ENTERPRISES
M/S Nexus Projects
V K LAKWAL CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .