Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹2.9 LAccepted-AOC 0 0 0 KHIRKITA DUBEY PAKARI GORAKHPUR UTTAR PRADESH 273412 | GORAKHPUR | UTTAR PRADESH | 273412 | I | Accepted-AOC Being lowest | |
| 2 | II₹2.9 LRejected-Finance 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | II | Rejected-Finance Refer itemwise comparative statement | |
| 3 | III₹2.9 LRejected-Finance GALI NO 2 H NO 45 2ND FLOOR NANAK VIHAR COLONY LAL KUAN GHAZIABAD UTTAR PRADESH 201009 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201009 | III | Rejected-Finance Refer itemwise comparative statement | |
| 4 | IV₹3 LRejected-Finance | IV | Rejected-Finance Refer itemwise comparative statement | |
| 5 | IV₹3 LRejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | IV | Rejected-Finance Refer itemwise comparative statement |
Tender Value
Refer Docs
Closing Date
20 Mar 2021, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST AGRA
GE WEST AGRA
JOB WORK REPAIR/REPLACEMENT OF FEEDER SUPPLY SYSTEM OF GE(WEST) OFFICE COMPLEX AND CWE RESIDENCE UNDER GE (WEST) AGRA
2021_MES_430373_1
3340/Q/70/E3/2020-21
Limited
Miscellaneous Works
Works
30 days
GE WEST AGRA
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
23 Mar 2021
13 Mar 2021
22 Mar 2021
15 Mar 2021
20 Mar 2021
15 Mar 2021
45 days
Amount
Description of work are as under:- (a) Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core complete all as specified and directed. Qty- 105 RM (b) Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed. Qty- 85 RM (c) Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed. Qty- 25 RM (d) Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed. Qty-60 RM (e) Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed. Qty- 85 RM (f) Excavation in trenches not exc 1.5m width and n. exc 1.5m in depth and getting out for laying of pipes etc in any type of soil. Qty- 82.62 Cum M & L for Sand filling /cushioning dry fine in trenches for cable cushioning 8 cm below and 15 cm abobe the cable & cableunder / punned down to 18 cm over all complete all as specified and directed.Qty- 23.25Cum (h) M&L for bricks sub class B layed in trenches for cable protection such a manner width is equal to length complete all as specified and direccted. Qty- 2039 Each. (j) Returning filling in incl spreading levelling watering and well ramming in layers n.exc 25cm in any type of soil. Qty- 48.05 Cum (k) Removing excavated material n.exc 50m and depositing where directed at a level n. exc 1.5m above starting point. Qty- 34.57 Cum (l) Supply,fixing,connecting & testing factory made epoxy powdercoated, distribution board (sheet metal encloser), triple pole and neutral, 4 ways (verticle DBs), with metal door and fixed flush wall and suitable for universal mounting with having copper bus bar of capacity 200 Amp rating, of suitable size, for double door and suitable for using MCCB, 4 pole as incommer and SP MCBs as out going confirming to IS 13032 complete all as specified and directed. (Note :- Switch gears shall be measured and paid separately under appropriate item of Sch 'A'. Qty-01 Each (m) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA. Qty- 01 Each (n) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA. Qty- 1 Each (o) MCCB 3 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA. Qty- 12 each (p) MCCB 3 Pole, 415 V, fixed type, 63 Amps with breaking capacity 16 KA. Qty- 1 Each (q) M&L for cubical, self supporting duct and vermin proof feeder piller box suitable for housing 1 No incoming MCCB of Cap 200 Amp, 3 Ph, 4 wire, 50 hz AC supply but incl aluminum bus bar of cap 300 amp rating mounted on insulators including grauting in PCC foundation with PCC (1:3:6) with 20 mm graded stone aggregate duly factory febricated with framing angle iron 40/40 x 5 mm and covering with 2 mm CRCA sheeet duly painted with two coat powder coated over coat of redoxide primer. Qty 01 Each. (r) S & F in replacement MCB single pole 32-40 Amps SP, C series haviing short circuit rating 10 Kilo Amp 240 Volt all as specified and directed. Qty-12 Each.
M/S OM Enterprises
M/s A K Engineering Co
Shiva Enterprises
M/s Tirupati Enterprises
Gupta Automobiles
Sumesh Funiture
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_480512.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .