Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC NEAR GAYRTI TEMPLE PURANI GINANI BIKANER | BIKANER | BIKANER | RAJASTHAN | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.3 L+₹1.4 L (3.59%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | L3₹41.3 L+₹1.4 L (3.59%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted other then L1 | |
| 4 | L4₹43.6 L+₹3.7 L (9.40%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L4 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹80,332
Closing Date
7 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
SPL REPAIR TO BLDGS AND RW AND LBW WORK UNDER GE SGNR AT MILITARY STATION SRI GANGANAGAR
2021_MES_463514_5
GE SGNR/ TOK-27 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE Sri Ganganagar
D Class a(i) and b(i) for un-enlisted, refer NIT para 8
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹80,332
Yes
28 Jan 2022
17 Dec 2021
10 Jan 2022
17 Dec 2021
7 Jan 2022
24 Dec 2021
60 days
Amount
Surface excavation n.exc 30 cm deep and averaging 15cm deep, surface preparation as per required gradient and camber including well ramming and getting out in soft/loose soil including cutting of grass roots, bushes if any and filling of lower portion with soil obtained from cutting or dressing complete all as specified and directed by Engineer - in - Charge
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and directed by Engineer - in - Charge
Returning filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cms thick in soft/ loose soil complete all as specified and directed by Engineer - in - Charge.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer - in - Charge.
Removing excavated material n. exc. 50 m & depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer - in - Charge.
M&L for hard core of gauge n. exc 63 mm, deposited spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed by Engineer - in - Charge.
M&L for PCC (1:4:8) type D-2, (40 mm graded stone aggregate) as in foundation filling in mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for PCC 1:2:4 type B2(20 mm graded aggregate) as in roof padding/mass concrete complete all as specified and directed by Engineer in chgarge.
M&L cement concrete 1:5:10 Type E-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L Cement concrete 1:2:4 type B–0(12.5 mm graded stone aggregate) filling of pressed steel frame and hold fast blocks etc complete all as specified and directed by Engineer - in - Charge.
M&L for PCC 1: 2:4 Type B-1 (20mm graded stone aggregate) as in block masonry with solid blocks, exc. 10 cm in width and setting as in curb stone set in CM 1:4 complete all as specified and directed by Engineer - in - Charge
M&L for RCC 1: 2:4 Type B-1 (20mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (Design mix M-30 ) (20mm graded stone aggregate) as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses complete all as specified and directed by Engineer - in - Charge
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (Design mix M-30 ) (20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer - in - Charge
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (20mm graded stone aggregate) as in Columns complete all as specified and directed by Engineer - in - Charge
M&L for RCC nominal mix 1:1 1.5: 3 (using 20mm graded aggregate ) as in slabs suppotred on walls, beams and columns complete all as specified and directed by Engineer - in - Charge.
Supply only Integral water proofing compound ISI marked confirming to IS 2645 - 2003 complete all as specified and directed by Engineer - in - Charge.
M&L brick work with fly Ash old size Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
M & L brick work with old size fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed by Engineer - in - Charge
Use and waste of form work torough finished surfaces to soffits to suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick complete all as specified and directed by Engineer - in - Charge.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed by Engineer - in - Charge
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work n exc 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer - in - Charge
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engineer - in - Charge
M&L for formwork to to sides of pillars, posts, struts, piers, columns and stanchions including for edges rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge
M&L for form work for fair finished surfaces to edges of concrete flats, roofs and sides of RCC, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and directed by Engineer - in - Charge.
S & F for 35mm thick factory made gauged skelton shutters open rebated and prepared to receive gauze etc edges of framing plain, chamfered or rounded fitted with cut and mitred beady for receiving gauze etc of 35mm thick and door for Iind class hard wood rail and style as specified in SSR Part-I Section 8, cluase 8.24(a) and all as specified and directed by Engr-in-Charge.
S&F 2nd class hard wood factory made Plain, framed, pannelled shutters 35 mm thick (two panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I) Kiln seasoned and chemically pressure treated complete all as specified and directecd by Engr-in-charge.
Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters (W/out taking off shutters from the frames) complete all as specified and directecd by Engr-in-charge.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each as doors, windows & ventilators etc. and removal from site complete all as specified and directecd by Engr-in-charge.
S&F for 10mm thick PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium / G.I. / M.S. as per specification and drawing complete all as specified and directed by Engineer - in - Charge
S&F Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
S&F for factory made solid panel FRP door shutter shall be 30mm thick (style) glass fibre reinforced plastic panel door shutter of required colour with fire retardent grade and saturated polyster resin moulded to 3 mm thick FRP liminated for forming hollow rails and style with wodden frame and suitable block of seasoned wood inside at reqd places for fixing of fittings cast monolithically with 5 mm thick FRP panel and conforming to IS 14856:2000. suppling and fixing in the frame at site as per specification shown on drawings. complete all as specified and directecd by Engr-in-charge.
S&F in repairs 125 mm long mild steel barrel tower bolts, ISI market stove enamelled block with bright bolt and fixed complete all as specified and directecd by Engr-in-charge.
S&F in repairs mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed 125 mm size complete all as specifdied and directed by Engineer in charge.
S&F in repairs 125mm long oval type mild steel pressed handles, ISI marked stove enamelled black complete all as specified and directecd by Engr-in-charge.
S&F Aluminium anodised barrel tower bolts, 100 mm long of extruded section complete all as specified and directed Engineer - in - Charge.
S & F alluminium anodised fabricated barrel tower bolts 150mm long extruded section complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 300 mm long mild steel sliding bolt plate type stove enamelled black with bright bolt not less than 12 mm dia with and including a minium of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified and directecd by Engr-in-charge.
S&F mild steel butt hinges “medium weight” 100mm long cold rolled mild steel complete all as specified and directed by Engineer - in - Charge.
S&F 75 mm Butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type C-21 complete all as specified and directecd by Engr-in-charge.
S&F stainless steel butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type C-22 of size 100 mm fixing properly with screws etc complete all as specified and directed by Engineer - in - Charge..
S & F aluminium handles cast type anodised, 100mm long complete all as specified and directed by Engineer - in - Charge.
S & F 150 mm long extruded aluminium alloy handles, fabricated D- type, anodised complete all as specified and directed by Engineer - in - Charge
S&F mortice lock with two lever (vertical type) with brass body 100 mm long complete all as specified and directed by Engineer-in-charge.
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges including brackets complete all as specified and directed by Engineer-in-Charge.
S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor and overall length of cover plate 140 mm complete all as specified and directed by Engineer in charge.
S&F door closer hydraulically regulated, designation No. 3, universal type, suitabel for door shutters (aluminium body) of any size complete all as specified and directed by Engineer-in-charge.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and avarage width of aparture 1.40mm and fixed etc., complete all as specified and directed by Engineer - in - Charge.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engr-in-charge.
S&F Aluminium frame for doors, window, ventilators with one or more rebates including joining cleat for fixing etc complete with powder coating on Aluminium minimum thickness of powder coating 50 micron as per the specification the top and bottom horizontal members and vertical members adjacent walls shall be fixed with floor, ceiling walls and cills where required and fixing with the help of rawal plug and screw or with fixing clip or with expansion hold plate fasteners . Aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required all complete as per the direction of Engineer-in-charge
S&F Aluminium door shutters, aluminum section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, powder coated aluminium snap beading screws, powder coated aluminium fitting such as hinges type B-21 100 mm size, suitable handle, tower bolt, sliding door bolt etc of any colour (thickness of powder coating not less than 50micron) etc complete all as specified and directed.
S&F Aluminium window and ventilator shutter (glazed and gauzed both),side hung type without sash bars, aluminum section weighing 0.55 Kg/m including necessary joining cleats, glazing, clips, rubber packing, anodised aluminium snap beading screws,aluminium fitting such as peg stays 150mm long (01 nos), hinges type B-21 100mm long (02 Nos) suitable handle (01 No) with powder coating of any colour (thickness of powder coating not less than 50micron) etc complete all as specified and directed by Engineer - in - Charge. Note: Only Glass and wiremesh will be measured and paid seperately.
M&L bands straps supports or stays for rainwater ventilating pipes including bolts confirming to Fe 410 Gde E-165 or Fe 290 Gde E-165 all as specified and directed by Engr-in-charge.
M&L for TMT bars 6 TO 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer - in - Charge.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer - in - Charge.
S&F Pressed steel frames of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, (thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM 1:6 complete all as specified and directecd by Engr-in-charge.
S&F Aluminium sliding door/window/ventilators with one or more rebates including all fittings and joining cleat for fixing, etc complete as per the specification the top and bottom horizontal members and vertical members adjacent walls shall be fixed with floor, ceiling walls and cills where required and fixing with the help of rawl plug and screw or with fixing clip or with expansion hold plate fasteners . Aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required all complete as per the direction of Engineer-in-charge
M&L for Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed by Engineer - in - Charge. Note :- Minimum thickness of powder coating shall not be less than 50 micron.
S&F aluminium windows and ventilator shutters, side hung type without sash bars, aluminium saction weighing 0.55 kg/M including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fitting such as aluminium peg stay 150mm long (1No), powder coated aluminium hinges type B-21 100 mm long (2No), suitable powder coated aluminium handle -(1No), and powder coated aluminium self closing tower bolt 75mm long (1No) complete all as specified and directed by Engineer - in - Charge. Note; Sheet Glass shall be paid separately.
S&F for Anodised Aluminium Frame work (snap grid size 605X605mm) for false ceiling complete all as specified and directed by Engineer - in - Charge.
S&F for Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed by Engineer - in - Charge
M&L for 40 mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar ( 1:3) mixed with 5 % of cruide oil by weight of cement complete all as specified and directed.
Taking down rain water pipe and eaves gutters (any size and pattern) including all fittings heads shoes bends swan necks etc including cleaning or refixing or removal to store(measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engineer - in - Charge.
M&L for 12 mm thick both side prelaminated (One side decorative and one side plain) particle board exterior grade fixed with screws to timber frame work complete all as specified and directecd by Engr-in-charge.
M&L for 75mm thick cement concrete (1:4:8) type D-2, (40 mm graded stone aggregate) as in sub base, foundation filling and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for 25 mm thick cement concrete 1:2:4, Type B-0 (12.5mm graded aggregate) as in floor finished even and fair complete all as specified and directed by Engineer - in - Charge.
M&L non skid Ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in CM 1:4 and set and jointed in cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M&L for precast coloured rubber moulded concrete machine pressed concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60 mm thickness, M 35 grade set, jointed and pointed in neat cement slurry in floors/paving/path etc wirh grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
M&L for granite (of any type) tiles 20 mm thick machine cut, bedded & jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over 15 mm thick screed bed in CM 1:4 etc complete all as specified and directed by Engineer - in - Charge
M&L for granite (of any type) 20 mm thick work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. over and including 15 mm thick screed bed in CM 1:3 complete all as specified and directed by Engineer-in-charge.
M&L for 75mm thick Cement concrete type C-2 , 1:3:6 (20 mm graded aggregate) as in plinth protection complete all as specified and directed by Engineer - in - Charge.
M&L for 75mm thick Cement concrete type C-2 , 1:3:6 (40 mm graded aggregate) as in plinth protection laid in bay n.exc 2.5m length with joint to be filled with bituminous Grade 'B' omplete all as specified and directed by Engineer - in - Charge. Note:- Rate of Grade 'B' included in this item. No extra shall be paid.
S&F glazed ceramic coloured tiles 7mm thick 450 x 300mm or 600x300 mm size in verticle surface like skirting/dado etc,. laid over and including 10 mm thick rendering in CM 1:4, set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade. etc complete all as specified and directed by Engineer - in - Charge.
M&L for virified light shed tiles 10mm thick (square / rectangular) area of each tile exc. 0.36 sqm but n. exc 0.42 Sqm in floors etc. laid over and including 15 mm thick screed bed in CM 1:4, set and jointed in cement slurry mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing and removing rubbish off the premises complete all as specified and directed by Engineer - in - Charge.
Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc complete all as specified and directecd by Engr-in-charge.
M&L 5mm thick, rendering in cement mortar 1:3 to ceiling surfaces on patches finished even and smooth without using extra cement in patches complete all as specified and directed by Engr-in-Charge.
M&L for 15mm thick rendering in patches in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and directecd by Engr-in-charge.
M&L 15mm thick, rendering in cement mortar CM 1:4 to brick/concrete wall surfaces in two layers first layer 10mm thick and second layer 5mm thick with WPC 3% by wt of cement finished even & smooth without using extra cement complete all as specified and directed by Engr-in-Charge.. (Note : WPC shall be measured and paid for separately)
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper, over a coat of chalk whiting complete all as specified and directed by Engineer-in-Charge.
M&L two coats of cement base paint over a coat of white washing to new plastered surface on wall including preparation complete all as specified and directed by Engineer - in - Charge.
M&L three coats of white wash on new plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
M&L three coats of white wash to undecorated ceiling surfaces including preparation of new surfaces complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of old surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and making surface even and smooth andcomplete and then appplying two coats of white wash on old decorated plastered or un-plastered surfaces of walls etc all as specified & directed by Engineer-in-Charge.
M&L for preparation of old surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and removing all dirt and dust by watering making surface even and smooth and then applying one coats of cement base paint over well prepared old decorated plastered surface etc all as specified and directed by Engineer - in - Charge.
M&L preparing new wood or wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying one coat of red oxide zinc chrome primer and two coats of synthetic enamel paint (for steel surfaces) including preparation of surface complete all as specified and directed by Engineer - in - Charge.
S&F steel water tubing galvanised 15mm bore, “medium grade” with all fittings fixed to wall and ceiling or in floor complete all as specified and directed by Engineer - in - Charge.
S&F steel water tubing galvanised 20mm bore, “medium grade” with all fittings fixed to wall and ceiling or in floor complete all as specified and directed by Engineer - in - Charge.
Taking up or down for 15mm bore steel water tubing galvanised with connection including cleaning for refixing complete all as specified and directed by Engineer - in - Charge.
Taking up or down for 20mm bore steel water tubing galvanised with connection including cleaning for refixing complete all as specified and directed by Engineer - in - Charge.
S&F low density polyethylene pipes (LDPE) 32 mm dia and 800 mm long of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed by Engineer in charge.
S&F in repairs low density polyethylene pipes (LDPE) 32 mm dia and 1000 mm long of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed by Engineer in charge.
Dismantling water tanks of any description n.exc 1000 ltrs capacityand removal from site complete all as specified and directed by Engineer - in - Charge.
S&F 1000 ltrs capacity Rotational moulded polyethylene in white coloured three layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer - in - Charge.
S & F for Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed for15mm bore dia complete all as specified and directed by Engineer - in - Charge
S&F in repairs, stop valves, chromium plated cast screwed down, high pressure copper alloy, with crutch or butterfly handles, screwed both ends for but fancy type 15mm bore iron pipe or complete all as specified and directed by Engineer - in - Charge.
S & F in repairs 15 mm dia bore fancy type chromium plated (concealed type) stop valves of cast copper alloy with long shank & cup etc. complete all as specified and directed by Engineer - in - Charge.
S&F 20 mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer - in - Charge.
S&F Waste coupling of stainless steel (half or full threaded) of 40 mm complete all as specified and directed by Engineer - in - Charge
S&F grating doom 100 mm dia of PTMT (min weight 25 grms)with and without hole complete all as specified and directed by Engineer vin charge.
S&F in repairs grating doom 100 mm dia of PTMT with and without hole complete all as specified and directed by Engineer vin charge.
S&F in repairs Urinal spreader of PTMT any colour for fixing 15 mm dia pipe complete all as specified and directed by Engineer in charge.
S & F in repair PVC connection 15 mm size with PTMT nuts of length 450 mm of approved quality complete all as specified and directed by Engineer - in - Charge.
S & F PVC connection 15 mm size with PTMT nuts of length 450 mm of approved quality complete all as specified and directed by Engineer - in - Charge.
S&F 75mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints but laid in trenches / floors complete all as specified and directecd by Engr-in-charge.
S&F 100mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints but fixed to walls & fixing with clamps complete all as specified and directecd by Engr-in-charge.
S&F 100mm bore cast iron Bends (any radius),with duck's foot or heel rest diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore cast iron Bends (any radius),with duck's foot or heel rest diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S & F 110 mm bore of pipe PVC (SWR) pipes single socket in any length with rubber ring joint fixed to walls with MS clamps complete all as specified and directed by Engineer - in - Charge.
S & F 110 mm bore of pipe PVC (SWR) bends of any radius / shoe fixed to PVC pipes complete all as specified and directed by Engineer - in - Charge.
M&L for 100 mm extra over cast iron pipes and fittings if lead joint is provided in lieu of cement joint complete all as specified and directed by Engr-in-charge
M&L for 75 mm extra over cast iron pipes and fittings if lead joint is provided in lieu of cement joint complete all as specified and directed by Engr-in-charge
M&L for CI floor trap 100 mm with anti cockroaches grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified and directed by Engr-in-charge.
M&L for CI floor trap 75 mm with anti cockroaches grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directecd by Engr-in-charge.
M&L for reinfocement concrete pipes, class NP2, 150 mm dia grade -A laid on concrete bed to required slope and jointed and tested complete with collars complete all as specified and directed by Engineer - in - Charge. Note; concrete Glass shall be paid separately.
S&F in repairs,fency types bib taps,15 mm cast copper alloy, with crutch or butterfly handles, screwed down, screwed for iron pipe or brass ferrule for 15mm bore complete all as specified and directed by Engineer - in - Charge.
S&F in repair 15 mm dia bore fancy type chromium plated Pillar taps,cast copper alloy,with capstan heads, chromium plated,screwed down high pressure,with or wothout lettered Hot or cold with long screwed shanks anf fly-nuts screwed for iron pipe, complete all as specified and as directed.
S&F 100 bore, CI bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door as in repairs complete all as specified and directecd by Engr-in-charge.
S&F in repairs vitreous china urinals, bowl type flat back size of 465x355x265 mm complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe grating and union for discharge pipe including waste pipe and trap complete all as specified and directed by Engg in charge.
S&F, in repair vitreous china wash hand basin, white flat back of size 550mmx400mm including brackets, 32mm bore brass chromimum plated waste coupling & 32mm bore low density ployethylene (LDPE) flush pipe of pressure rating 6Kgf/Sq cm (1.00 M long) complete, including 15mm bore 450 mm length PVC connection with PTMT nuts complete all as specified and directed by Engineer - in - Charge.
Fixing only vitreous china wash down water closet pan (Pedstal pattern), complete all as specified and directed by Engineer - in - Charge.
S&F in repair vitreous china wash down water closet pan (Pedstal pattern), white excluding fixing bolts, flushing cistern and flush pipe, including plastic water coset seat, black cosed pattern with flat bottom, and cover and mild steel chromimum plated hinging device & trap. complete all as specified and directed by Engineer - in - Charge.
S&F in repairs, PVC low level flushing cistern 10 lirs capacity, valve-less, syphonic action type, white, with inlet, ball valve, float, and handle including brackets, PVC connections 15 mm size with PTMT nuts of length 450 mm ,including 32mm bore flush pipe of polyethylene of low or high density of PVC complete all as specified and directed by Engineer - in - Charge.
S&F in repair brass chromium plated shower rose 125 mm of size with arm and with or without swivel joints to steel pipe or union complete all as specified and directed by Engineer - in - Charge.
S&F in repairs Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed by Engineer in charge.
S&F in repairs soap dish of any size fixed with screws complete all as specified and directed by Engineer in charge.
Dismantling stone slabs of any description or thickness in floors, apron etc laid bedded and pointed in any mortar complete all as specified and directed by Engineer - in - Charge.
Demolition of cement Concrete(un-renforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer - in - Charge.
Demolition of cement concrete of any description and in any position for sunken portion and floor all as specified and directed by Engr-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer - in - Charge.
Dismantling of brick tiles or terracing tiles single layer on roof complete all as specified and directed by Engineer - in - Charge.
Demolition of old mud phuska, removing rubbish of the premises cleaning surface and preparing to receive new mud plaster complete all as specified and directed by Engineer-in-Charge.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, where directed complete all as specified and directed by Engineer - in - Charge.
Dismantling and disconnecting existing CI soil waste/vent pipe 100 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and directed by Engineer-in-Charge.
Demolition Cement concrete (reinforced) roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engineer - in - Charge.
S&F vitreous china urinal, bowl type (back or corner wall type), complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinals to plug with and including 60mm long brass screws and brackets, 32mm bore LDPE flush pipe of pressure rating 6 Kg/ Cm2 and grating and union for discharge pipe, waste coupling of PTMT minimum weight 45 gm, including urinal spreader of PTMT any colour for fixing with 15 mm dia pipe complete all as specified and directed by Engineer - in - Charge.
Supply solo single piece WC with UF soft close seat cover, hinges, fixing accessories, accessories set and cistern fittings size 360x725x735 mm, s trap 300 mm complete all as specified and directed by Engr-in-charge. Make:-Jaquar SLS-WHT-6851S300PP
S&F aluminium grills any pattern fixed with aluminium frame including all necessary fixing arrangments complete all as specified and as directed by Engineer - in - Charge. Note:- Design shall be approved by Engineer - in - Charge. Note; aluminium frame shall be paid separately.
M&L for heat resistant aluminium painting on roof water proffed surface complete all as specified and directed by Engineer - in - Charge.
S&F three tier Shelf of 5mm thick Glass fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engineer - in - Charge.
S&F towel ring brass glossy finish with screws complete all as specified and directed by Engineer - in - Charge.
S&F soap dish brass glossy finish fixed with screws complete all as specified and directed by Engineer - in - Charge.
S&F thin rim table top basin, shape triangle of size 600x410x100 mm complete all as specified and directed by Engineer - in - Charge
S&F door stopper and silencer rubber 50-70 mm dia fixed in door complete all as specified and directed by Engineer-in-chrage.
S&F stainless toilet paper holder, vitreous China, box type complete all as specified and directed by Engineer - in - Charge. Make : Parryware cat part No T-6514A1, Prayag cat part No -BA-88
S&F health faucet 2 in 1 with 1.5 m tube and hook of same make complete all as specified and directed by Engineer - in - Charge. Make : Hindware cat part No - 505223, Jaquar cat part No -ALD CHR-583
S & F stop/angle valves 15mm dia, cast copper alloy fancy type chromium plated with long shank and cup (concealed type) serewed down, high pressure , with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge. Make : Parryware cat part No T-4621A1, Prayag cat part No - 6418, Jaquar cat part No -CON-CHR-1080KN
Providing and applying two component cementitious and acrylic flexible protective coating with water proofing compound, two coats with Dr fixit LW+ on reinforced cement concrete slab and wall surfaces complete all as specified and directed by Engineer - in - Charge
S&F in repair vitreous china wash hand basin, white bowl type for chemical washing purpose of size 600mmx400mm including brackets, 32mm bore brass chromimum plated waste coupling & 32mm bore low density ployethylene (LDPE) flush pipe of pressure rating 6Kgf/Sq cm (1.00 M long) complete, including 15mm bore 450 mm length PVC connection with PTMT nuts. complete all as specified and directed by Engineer - in - Charge.
S&F 100mm bore cast iron 'Y' tee sand cast fitted with oval access door complete all as specified and directed by Engineer - in - Charge.
S & F in repair stainless steel tubular towel rail 20mm dia “D” type 60 cm long between flanges including brackets complete all as specified and directed by Engineer - in - Charge.
S & F 15mm bib tap with wall flange cast copper alloy,fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed by Engineer-in-Charge. Make: Prayag cat part no-8306 Parryware cat part no- T3504A1, Cera cat part no- HTF3001151 or equivalent cat part as approved by GE
M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below complete all as specified and directed by Engineer-in-Charge:- (a) applying 15 mm plaster in CM 1:3 with WPC on raised verticle surface (b) Cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc. (c) Creating fillet coving of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface (e) Provision of glass fiber mesh of 2 x 2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) Cement concrete 1:4:8 thickness 50mm over the coating as per requirment (h) Joining the saintary pipes with the water proofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout complete all as specified and directed by Engineer-in-Charge.ke:- Note: (i) PCC filling in sunken portion will be measured seperately. Make:- Sika/Fixit/Fosroc/STP
S&F brass CP mixer for mixing hot and cold water screwed down for iron pipe complete all as specified and directed by Engineer - in - Charge.
S&F stainless steel curtain rod 25 mm dia (minimum weight 0.36 Kg per RM) with brackets, fancy knobs and rings (20 cm c/c) etc complete all as specified and directed by Engr-in-charge.
Providing and applying waterproofing work with polyester reinforced APP membrane sheet of thickness 3mm by Mechanically clean the RCC slab and wall with wire brush / coir brush to freee from all loose materials like dust, dirt etc make wattah / coving of 50x50 mm at all horizontal and vertical joints to avoid right angle turning with polymer based mortar. Apply one coat of solvent based bitumen primer on cleaned & leveled surface @ 3-5 Sqmtr / ltr per coat. Unroll the Dr. FIxit Torchshield roll after application of primer. Align the Dr. FIxit Torchshield roll correctlv & re-roll it in alignment before torching. Use gas burner to heat substrate and underside to softening points. When the embossing disappers, roll forward and press fimly against substrate to bond from the lower end towards the higher end. Keep overlap margin for minimum 100mm. Heat both the overlaps and use round tipped trowel to seal overlap. Excess compound shoud be smoothened and pressed into seam using hot trowel.complete all as specified and directed by Engineer-In-Charge.
Supplying, laying, jointing, testing and commissioning 16 Sqmmx2 core XLPE insulated, heavy duty electric cable with aluminium conductor 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/ laid under roads/paths/ drain/ culverts or passing through pipes complete all as specified and directed by engineer in charge.
Taking down copper/aluminium point wiring (light,fan,socket or power)complete including fixture and fittings such as switches& sockets and removing materials for taking credit complete all as specified and directed by Engineer-in-charge.
M&L for concealed conduit point wiring complete for light /fan on indepandent/ combine board with cable 1.5 sqmm(Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC conduit pipe medium grade 20mm bore,pipe hooks,elbows,junction covers and junction boxes, after cutting in wall chasing for conduits and sinking's for sunken cast iron /pressed steel terminal boxes of suitable length and thickness for mounting switches, sockets, fan regulator with 3mm thick plastic laminated seat cover fixed with brass screws and cup washers, duly grouting and painted with red oxide metal primer and making good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth contuity conductor along with point wiring of 1.5 sqmm copper FRLS PVC insulated cable for one light/fan point controlled by one way switch and connected to common earth dolly, complete all as specified and directed by Engr-in-charge.
All as described in Srl item No -165 here in before but for one switch socket combination 5/6 Amps on independent board complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No -165 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No -165 here in before but for one three pin socket outlet 15 Amp on independent board with 2.5 Sqmm (Nominal Area) FRLS PVC insulated multistranded unsheathed copper conductor and continuous earth contuity conductor along with point wiring of 2.5 sqmm copper FRLS PVC insulated cable copper cable complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No -165 here in before but for one switch socket combination 6 pin 5/15 Amps on independent board with 2.5 Sqmm (Nominal Area) FRLS PVC insulated multistranded unsheathed copper conductor and continuous earth contuity conductor along with point wiring of 2.5 sqmm copper FRLS PVC insulated cable copper cable complete all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type 5/6 Amp single pole one way complete all as specified and directed by Engineer - in - Charge
S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.
S & F switch socket combination 5 pin, 5/6 Amps flush type complete all as specified and directed by Engineer - in - Charge
S&F Switch socket combination 2 in 1, 6 pin , 15/16 Amp flush universal type all as spd and directed by Engr in charge.
S & F Socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F ceiling rose, surface bakelite 65x50 mm three terminals complete all as specified and directed by Engineer - in - Charge.
S & F stepped type,single socket fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge
S & F in replacement industrial socket metel clad plug and socket with MCBs single pole 20 Amp complete all as specified and directed by Engineer - in - Charge
S & F in replacement sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn in existing PVC conduit dia 20 mm medium quality including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after cutting in wall chasing and making good disturbed surfaces of wall with white wash or existing colour, necessary junction boxes and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
S & F in replacment sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F LED lamp 9 W for angle holder complete all as specified and directed by Engineer - in - Charge.
S & F extruded aluminium LED batten channel 20 watt having input voltage AC90-300V, 50Hz,6500K, with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS20WLED865SPCSS, Bajaj cat part No. BCLSBAL 20W CW, Crompton cat part No. CCS-100-20-65-HL2-DP-NWH
S & F in replacement extruded aluminium LED batten channel 20 watt having input voltage AC90-300V, 50Hz,6500K, with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS20WLED865SPCSS, Bajaj cat part No. BCLSBAL 20W CW, Crompton cat part No. CCS-100-20-65-HL2-DP-NWH
S&F in replacement security light fitting LED TYPE 25 watt with all necessary accessories, Clear transparent acrylic cover, prewired suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. ENDURAPEARLSL25WLED757SASYTOPCMP, Bajaj cat part No. BRLEP 25 W, Crompton cat part No. LSTS-25-CDL-M
S & F water tight bulk head fitting, comprision of connector galvanised cast iron back plate, weather proof enamelled gallery, glass well and including 10 watt LED lamp complete all as specified and directed by Engineer-in-Charge. Make :-Havells cat part No. HEXAFT10WLED857SSYMBOPC, Bajaj cat part No. BIBWP 10W LED, Crompton cat part No. LBHP-10-CDL
S & F in repairs water tight bulk head fitting, comprision of connector galvanised cast iron back plate, weather proof enamelled gallery, glass well and including 10 watt LED lamp complete all as specified and directed by Engineer-in-Charge. Make :-Havells cat part No. HEXAFT10WLED857SSYMBOPC, Bajaj cat part No. BIBWP 10W LED, Crompton cat part No. LBHP-10-CDL
S&F split Air conditioner (Hot & cold) electric driven, single phase of capacity of 1.5 TR, 5 star rated compilance of 5410 watt of cooling and 5275 watt of heating or nearby, 36 db cooling or heating noise level, alarm function, digilick rotary type, inbuild inveter compressor complete all as specified and directed by the Engineer in charge. . Make:- Hitachi (Ace reiden) model No RAU518HTH or equvilent
S&F in replacement recess mounting 2x2 feet 36 watt LED luminaire with powder coated CRCA housing with LEDs, seamless front frame with high transmission acrylic cover and fixed electronic driver (surge protector ) complete all as specified and directed by Engineer - in - Charge . Make :-crompton cat part No. LCTLRNE-36-FO-CDL or equivalent make in Bajaj , havells
S&F compact decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1x10 watt fitting 2 ft version including LED lamp 10 watt complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS10WLED865SPCSS, Bajaj cat part No. BCLSB 10WH, Crompton cat part No. LDL-10-CDL
S&F in replacement compact decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1x10 watt fitting 2 ft version including LED lamp 10 watt complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS10WLED865SPCSS, Bajaj cat part No. BCLSB 10WH, Crompton cat part No. LDL-10-CDL
S&F Exhaust fan with high speed noiseless motor of size 300 mm sweep,5 star rating heavy duty by grouting both ends in wall upto required length and making hole of suitable size in wall, making good the existing surface and connecting with ceiling roses with and including flexible cable 3 core copper conductor of size 24/.2 mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan of suitable length with frame. louvers, nuts, bolts etc. including making good disturbed wall in CM(1:4) complete all asspecified and directed by Engineer - in - Charge. Make- Crompton/Bajaj/Havell's/Orient
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 4 mm dia GI earth wire, by means of bolts, nuts check nuts and washers of galvanised iron and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point including taking our unserviceable earthing with all acessories all as specified or indicated including testing on completionall as specified and directed by Engineer - in - Charge.
Excavation in trenches in n.exc. 1.5 m wide & n. exc. 1.5m in depth in soft/ loose soil for laying of cable complete all as specified and directed by Engineer - in - Charge
Supply & filling/ laying a layer of dry coarse sand 8 cm thick before laying ofcable and 15 cm thick after laying of cable complete all as specified and directed by Engineer - in - Charge. Note:- After punning drain 18 cm will be measured for payment.
M&L for brick protection layer with one brick wide using sub class ‘B’ bricks laid flat across the cable complete all as specified and directed by the Engineer in charge.
Note : Notes : (i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .