| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹43.8 L+₹8.5 L (24.1%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹44.3 L+₹9.0 L (25.4%)Rejected-Finance | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹49.2 L+₹13.9 L (39.2%)Rejected-Finance NOT AVAILABLE | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹54.2 L+₹18.9 L (53.6%)Rejected-Finance T 16 1 SHETTY HOTEL OLD NAVY NAGAR COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Other than being lowest |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
18 Sept 2024, 6:50 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
MANNING AND OPERATION ROUTINE MAINT/ LT DISTRIBUTION SYSTEM OF ELECTRIC SUPPLY AT INS ANGRE, INS KUNJALI, INS TRATA WORLI, RAFIYA MANZIL, INS VAJRABAHU, NMRL CELL ETC INSTALLATION AT VARIOUS LOCATION UNDER GE (NW) KUNJALI, COLABA, MUMBAI
2024_MES_667373_1
8351/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) Kunjali
Class C
Category b (i) d (v)
7 documents required · 7 mandatory
₹1,000
GE (NW) Kunjali
₹1.3 L
23 Dec 2024
22 Jul 2024
21 Sept 2024
22 Jul 2024
18 Sept 2024
12 Aug 2024
22 Jul 2024 - 10 Aug 2024
Amount
Manning and operation of electrical receiving substation 11KV/ 440 Volts at INS ANGRE power house by employing Skilled Electrician-01 No Per shift, in three shifts per day including Sundays and Holidays: Note: Shift Timing are as under:- (a) First shift : 0600hrs. To 1400hrs. (b) Second Shift :1400 Hrs to 22 00 Hrs (c) Third Shift : 2200 Hrs to 0600 Hrs (1 person x 3 shifts x 11 months)
Manning and operation of electrical receiving substation 11KV/ 440 Volts at INS Kunjali power house by employing Skilled Electrician-01 No Per shift, in two shifts per day including Sundays and Holidays : Note: Shift Timing are as under:- (a) First shift : 0600hrs. To 1400hrs. (b) Second Shift :1400 Hrs to 22 00 Hrs (1 person x 2 shifts x 11 months)
Manning and operation of electrical receiving substation 11KV/ 440 Volts NMRL power house by employing Skilled Electrician-01 No Per shift from 0900hrs to 1700hrs including Sundays and Holidays. (1 person x 1 shift x 11 months)
Manning and operation of electrical receiving substation 11KV/ 440 Volts at FMU Bldg by employing Skilled Electrician-01 No Per shift from 0900hrs to 1500hrs including Sundays and Holidays. (1 person x 1 shift x 11 months)
Manning and operation electrical receiving substation 11KV/ 440 Volts at RAFIYA MANZIL AND PCDA NAVY power house by employing Skilled Electrician-01 No Per shift from 0900hrs to 1500hrs including Sunday / Holidays. (1 person x 1 shift x 11 months)
Manning and operation electrical receiving substation 11KV/ 440 Volts at MT CELL, KUNJALI by employing Skilled Electrician-01 No Per shift from 0900hrs to 1500hrs including Sundays and Holidays. (1 person x 1 shift x 11 months)
Notes for item no 1.00 to 6.00- i) The cost of employment of supervisior and any assitance required to operate and maintain the installations by operating staff shall deemed to be included in above quoted rates. ii) Each shift shall be of continuous 8 hours durations. As per industrial act one person should not be continued on duty for more than 06 days and he should be given weekly off day for his personal maintenance and one reliver should be employed for off duty by contractor without any extra cost to the Govt.The quoted rate shall deemed to be inclusive for provision of reliever on duty and leave periods on all days including Sundays/Gazetted Holidays. iii) The cost for maintenance of documents installations charts and daily records as mentioned in clauses of relevant particulars specifications shall deemed to be included in the rates quoted for above items. iv) The location of AC plants to be outsourced are lying inside restricted area and therefore the contractor/operating staff shall comply to all security measures/ restrictions imposed by the unit from time to time. v) The contractor has to arrange the dry/wet bulb thermometer for recording hourly room temperature.
(vi) The operator on duty shall wear proper uniform of light blue colour shirt and dark blue trouser duly printed name as MES and contractor with all protective arrangement during the duties like shoes, gloves etc and required tools for operation and maintenance of installation.The quoted rate shall deemed to be inclusive of minor services like greasing of bearings, replacment of glands/ rubber coupling, belts etc.Periodical cleaning of cooling tower and AHU filters is contractors responsibility. (vii) The installation shall be handed over in operating state on the commencement of contract though work order. (viii) Antecedents of the Personnel engaged by the contractor to carry out the work shall be verified from police authorities and accordingly security passes shall be issued. (ix) The contractor shall be solely responsible for all personnel deployed for carrying out the above jobs and all transport required for conveyance. The quoted rate shall deemed to be inclusive of EPF, ESIC etc all as per latest norms of labour Commissioner.
x). The labourers shall be provided with protective devices and shall wear them while working. In case any accident/ injury/ fatal or partial disability happened, the contractor shall be solely responsible for settling all claims/ compensation. Department will have a right to recover any sum indicated/ claimed by Labour Commissioner/ Court directive. (xi) Contractor has to render a certificate/ confirmation every month that minimum wages act is not violated and every employee engaged have been paid their wages through aadhar linked bank account only and laborers in full and receipts there on obtained. (xii) In case the absence of operator, the Accepting Officer and the Engineer-in-Charge (GE and AGE E/M) shall impose penalty of Rs 500/- per hour.The bidders are advised not to quote rate less than minimum fair wages as circulated by competent authority .
(xiii) The bidders are advised not to quote rate less than minimum fair wages as circulated by competent authority.If the quoted amount is less than the estimated cost given in SCH A Note on Page No 14 the lowest bidder will have to depost FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid (cover No 2). (xiv) The deposited amount shall be the difference between estimated cost given at SCH A Note on Page No 14 and amount quoted by lowest bidder for respective item. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to with hold the said amount which will beverified by GE. The decision of Accepting Officer regarding amont to be withheld shall be final and binding. The withheld amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected. The contractor shall submit 03 Nos of BGNs/FDRs of equal amount as mentioned above. The BGBs/FDRs validity shall be 04 months, 08 month & 12 months respectively for the purpose of encashment release as the case may be. (iv) The rates quoted shall be inclusive of suitable reliver wherever sundays & holidays are mentioned for working.
Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core. laid in trenches/ duct / along pole/wall etc including making connection complete all as specified and directed by the Engr-in- charge Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply, installation, testing and commissioning of ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1250 Amps with fabrication work in panel complete all as specified and directed by the Engr-in- charge
Taking down security/street light fitting for repair & checking internal wiring, cleaning complete & refixing the same in position after rectification of defects/repair of items complete all as specified and directed by the Engr-in- charge
Material & Labour for preparation of surfaces by scraping old paint with wire brush from steel tubular poles upto 9.0 mtr length above ground level including street light arms and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer and writing pole number complete all as specified and directed by Engr-in- charge
Supply & Fixing in repair decorative LED post tops with transparent diffuser 40W, IP 65 protection with all acessories and fixing arrangement, lumen efficacy of minimum 100 lumens per watt, built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 10%, CW available CCT of 6500K, power factor of minimum 0.95, integral high pressure die-cast aluminium housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours complete with all accessories.and all as specified and directed by Engr-in-charge
Supply & Fixing in repair LED garden light 9W cylindrical shaped integral decorative LED bollard with opal acrylic diffuser and IP 65 with all accessories including PCC foundation tapper plug, bolts, nuts, screws etc with all acessories and fixing arrangement, lumen efficacy of minimum 100 lumens per watt, built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 10%, CW available CCT of 6500K, power factor of minimum 0.95, integral high pressure die-cast aluminium housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours complete with all accessories. as specified and directed by Engr-in-charge.
Supply & Fixing in repair of LED street light 120 W energy saving and environment friendly light fitting with housed in pressure dia cast aluminium housing with sealed toughened glass cover, SMD LED with secondery lens luminaires with IP 66 protection including with all acessories and fixing arrangement, lumen efficacy of minimum 100 lumens per watt, built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 10%, CW available CCT of 6500K, power factor of minimum 0.95, integral high pressure die-cast aluminium housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours complete with all accessories. all as specified and directed by Engr-in-Charge.
Supply & Fixing in repair of LED street light 90 W energy saving and environment friendly light fitting with housed in pressure dia cast aluminium housing with sealed toughened glass cover, SMD LED with secondery lens luminaires with IP 66 protection including with all acessories and fixing arrangement, lumen efficacy of minimum 100 lumens per watt, built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 10%, CW available CCT of 6500K, power factor of minimum 0.95, integral high pressure die-cast aluminium housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours complete with all accessories. all as specified and directed by Engr-in-Charge.
Supply and fixing in repair of LED flood lights 200 W energy saving and enviromental friendly light fitting IP 66 high power LED floodlight with pressure die cast aluminium housing with all acessories and fixing arrangement, lumen efficacy of minimum 100 lumens per watt, built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 10%, CW available CCT of 6500K, power factor of minimum 0.95, integral high pressure die-cast aluminium housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours complete with all accessories.
Supply & Fixing in repair of LED highbay light 150 W energy saving and envirment friendly light fitting, pressure dia cast aluminium housing with aim & adjustable bracket, matt finished reflector for gglare elimination, SMD LED with secondary lens with IP 66 protection including with all acessories and fixing arrangement, lumen efficacy of minimum 100 lumens per watt, built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 10%, CW available CCT of 6500K, power factor of minimum 0.95, integral high pressure die-cast aluminium housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours complete with all accessories.all as specified and directed by Engr-in-Charge.
Chakshu Enterprise (BID ID -3092708)
shubham construction (BID ID -3088789)
SHREE JAGDISH FURNITURE CO. (BID ID -3076636)
Shetty Construction Co (BID ID -3093009)
M/s S.D Construction Co (BID ID -3093132)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .