Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹13.9 L+₹76,795 (5.83%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L2 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
2 Jan 2024, 6:00 pmClosed
Shri Sahil Ratusaria, IDSE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REPAIR/REPLACEMENT OF ELECTRIC FITTINGS AND FIXTURES INCLUDING REWIRING TO CERTAIN OTM ACCN AT 1 (I) R O FLIGHT LPH AREA UNDER GE RANCHI
2023_MES_630880_1
8400/1206/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class E Cat b (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹44,000
Yes
2 Feb 2024
2 Dec 2023
4 Jan 2024
3 Dec 2023
2 Jan 2024
15 Dec 2023
Amount
Taking down carefully exising unserviceable aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed.
Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed.
M&L Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :- (Note- Modular cover plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before.
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common earth dolly.
M&L Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- (Note- Modular cover plate of any module with all fittings are included in point wiring.)
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
Description all as per item No 6 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
M&L Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick, 60 mm deep with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
Description all as per item No 8 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
S&F Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
S&F Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
S&F Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S&F Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
S & F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified.
S & F ceiling fan regulator switch type, step type, flush type heavy duty, 120 watts suitable to work on 230 volts Ac supply including removal of old unserviceable one complete all as specified.
S&F Bell push modular 6 Amps single module complete all as specified.
Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
S&F Lamp holder, PVC body suitable for batten fitting completes all as specified.
S&F Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified
S&F Switch piano flush type, single pole, one way, and 6 Amp complete all as specified.
S & F Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified.
S&F in replacement of switch socket combinations flush 5 Amp 5 pin competeI ,ISI marked
S&F switch socket combination 2 in 1, 3 pin, 15 amp multipurpose, flush type, all as specified and as directed
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall etc including one run of PVC insulated 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable,one run of 2.5 sqmm cable and one run of PVC casing caping will be measured as one unit
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit
S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 63 Amps with extended terminals complete all as specified.
S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 100 Amps with extended terminals complete all as specified.
Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S & F for Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and including provision of LED bulb 10/12 watts complete all as specified and as directed.
S & F for LED 10 watts batten aluminium extruded (mirror light) with decorative end caps complete all as specified and as directed. Make- Bajaj, Havells, Philips.
S & F Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed. Make :- Bajaj , Philips, Havells.
S & F for Highly efficient LED Bulbs, 10 W, of make Bajaj, Havells, HPL complete all as specified and directed
S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed.
S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 40-63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed.
Supply and replacing 1100 volts grade heavy duty PVC insulated aluminium conductor, served with inner sheathing of PVC in service connections suspended by insulating hangers not more than 1 mtr apart including 4 mm dia GI suspension wire, one twin core cable of size 10 Sqmm multi -strand complete all as specified and directed.
All as per item No 43 above but size 6 sqmm twin core cable.
All as per item No 43 above but size 4 sqmm twin core cable.
S&F Fan condenser, 2.5 Mfd, 240 volts for fan including PVC clamp at different locations as per site given by Engineer-in-Charge
S & F for recess mounted 2' x 2' square LED panel 36 watts, 596 x 596 x 9 mm size, sleek design aluminium housing, polycarbibate diffuser white powder coated finish operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and as directed.
S & F for LED post top lantern (gate light) 20 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia including removal of old unserviceable one complete all as specified and directed.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 4 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
S&F in replacement of flexible wire twin core copper conductor of size 23/0.0076 for fans and tube lights/ pendant fittings connection all as specified and directed
S&F casing and capping size 20 mm including removal of old unserviceable one complete all as specified and as directed
S & F metal body exhaust fan, AC single phase, 240 V of size 225 mm sweep 1380 rpm with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and M&L for making hole and proper finishing the surface as existing before and taking down of old unserviceable fan complete all as specified and as directed
S & F wall mounted fan, AC single phase, 240 V of size 400 mm sweep 1350 rpm with minimum cmm air delivery rate including necessary connection and taking down of old unserviceable fan and deposit it to LPH yard complete all as specified and as directed
M & L earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
Raj Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .