Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹17.9 L+₹62,340 (3.60%)Rejected-Finance 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L2 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 3 | L3₹19.1 L+₹1.8 L (10.4%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L3 | Rejected-Finance NOT BEING LOWEST BIDDER |
Tender Value
₹18.9 L
EMD Value
₹38,000
Closing Date
5 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT LUCKNOW
GE (AF) BKT LUCKNOW
PROVN OF ANTI RADIATION WORKS SERVICES FOR I AND D LEVEL AT AF STN BKT
2024_MES_682896_1
8798/BKT/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BKT LUCKNOW
7 documents required · 7 mandatory
₹500
GE (AF) BKT
₹38,000
15 May 2025
7 Nov 2024
7 Dec 2024
7 Nov 2024
5 Dec 2024
21 Nov 2024
Amount
M&L for High build ESD coating-ARC 283 silicon epoxy conductive coating on lab floors applied two coats with optimum thickness with copper strip for attaining a conductive rating alongwith water & abrasion resistant complete all as specified and directed (Note – Two pack catalyst cured, combination slicon Epoxy conductive base ARC-283, give approx 350 to 450 micron layer thickness per coat, grey shade, with more than 75% soild contents, materials in accordance with building regulations (paint shall be done only to outside of the concrete & structure).
M&L for RFID/EMI/EMF blocking/shielding coating-ARC 273, coating on lab wall/ceiling applied two coat with optimal thickness for attaining desired shielding/attenuation of unwanted flow of RFID/EMI/EMF Radiation/frequency and electrical leakage rating along water & abrasion resistant complete all as specified and directed. (Note- one pack solvent based ARC-283, give approx 50 to 60 micron layer thickness per coat, grey shade, with more than 65% soild contents, materials in accordance with building regulations. (paint shall be done only to outside of the concrete & structure).
M&L for rendering 15 mm thick on fair faces of brick or concrete surface walls, in cement mortar (1:6), finished even and smooth with mechanical mechenism without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over one coat of wall care putty having average thickness 1mm with Mechanical Means and one coat of primer complete all as specified and as directed. Note: Primer and Distemper to be carried out through air less spray machine (Mechanical Means).
M&L for preparation of old plastered surfaces of walls by washing rubbing down and stopping of old distempered surface of wall including cornices etc & applying two coats of oil bound distemper over one coat of wall care putty having average thickness 1mm with Mechanical Means and one coat of primer complete all as specified and directed. (Note: Primer and Distemper to be carried out through air less spray machine (Mechanical Means).)
M & L for point wiring with two single core PVC insulated & PVC unsheathed FRLS-H multistranded copper conductor cable of size 1.5 sqmm 1100 volt grade in non metallic rigid PVC concelled conduit medium grade 25 mm dia with all accessories mounting all the surface of wall/ceiling/roof/etc with suitable size of module metal flush boxes and including modular front cover plate & back plate for mounting modular type switches /socket/fan/ regulator etc including provision of one single core PVC insulated and unsheathed multi stranded FRLS-H copper cable of size 1.5 sqmm 1100 volt grade as earth continuty conductor connected to common earth dolly switch board complete for following- -Make- Polycab/Finolex/RR kabels/Plaza/ Havells. One light point controlled by one switch SP 5 Amps ,240 V
S&F switch modular type 1 module single pole, one way 5 Amps.Complete all as specified and dirceted. Make- Goldmedal/Crabtree(Havells)/L&T/Legrand.
M&L for ceiling rose,PVC/polycarbonate, isolated body. Complete all as specified and dirceted.
S&F Submain wiring with two single core PVC insulated FRLS-H multistrand copper conductor cable of size 2.5 Sq mm drawn into and including non metallic medium duty rigid concealed PVC condute not less than 25 mm size ISI marked with all fittings / accessories and 2.5 Sq mm FRLS-H multistrand copper conductor cable as continuous earth wire complete.Make- Polycab/Finolex/RR kabels/Plaza/ Havells. (Note :- for submain wiring: Two run of single core cable and one run of earth wire will be measured as one length and conduit with its accessories is deemed to be included in the unit rate quoted for this items.)
S&F Submain wiring with two single core PVC insulated FRLS-H multistrand copper conductor cable of size 10Sq mm drawn into and including non metallic heavy duty rigid concealed PVC condute not less than 25 mm size ISI marked with all fittings / accessories and 10Sq mm FRLS-H multistrand copper conductor cable as continuous earth wire complete.Make- Polycab/Finolex/RR kabels/Plaza /Havells. (Note :- For submain wiring: Two run of single core cable and one run of earth wire will be measured as one length and conduit with its accessories is deemed to be included in the unit rate quoted for this items.)
S&F Sheet metal enclosure 12 way double door distribution board when MCB to be used SPN 240 volt sheet complete all as specified and directed. Make- Indoasian/Legrand/L&T /Havells.
S&F MCB SPN 32 to 40 Amps 240 volt,50 hz,10 KA breaking capacity :C" curved type complete all as specified and directed. Make- Indoasian/Legrand/L&T /Havells
S&F MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified and directed. Make- Indoasian/Legrand/L&T /Havells.
S&F in repair flood light fitting with new generation energy saving enivornment friendly long life exclusive innoative die cast alluminium IP 66 LED flood light with hight power individual LED s as light source of capacity 100 watt complete and making conection with using 2.5 sqmm PVC insulated multistranded copper conductor two single core cable complete all as specified and directed. Make- Bajaj cat-169834 force/Havells cat part-JETA IRISFLS make in philips/Havells/CG as approved by GE in writting.
M&L for earthing complete with galvanised steel earth plate electrode 600cm x 600cmx6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part-I connected to earthing point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) precast PCC pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate with RCC (1:2:4) type B-1 using 20mm graded stone aggregate 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete.
Industrial Traders (BID ID -3176123)
GIAN ENGINEERS (BID ID -3181869)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .