| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC 28 A KG MARG CENTRAL DELHI DELHI 110001 | NEW DELHI | DELHI | 110001 | L1 | Accepted-AOC TERMS AND CONDITIONS ACCEPTED | |
| 2 | L2₹17.2 L+₹63,542 (3.84%)Rejected-Finance NO 23 SECOND MAIN ROAD RAJAMMAL NAGAR MADAMBAKKAM CHENNAI 600 126 | CHENNAI | CHENGALPATTU | TAMIL NADU | 600126 | L2 | Rejected-Finance Rejected being not the lowest | |
| 3 | L3₹25.8 L+₹9.3 L (56.2%)Rejected-Finance NO 94 OLD NO 100 19TH MAIN ROAD 1ST N BLOCK RAJAJI NAGAR BANGALORE 560 010 | BANGALORE | BANGALORE | KARNATAKA | 560010 | L3 | Rejected-Finance Rejected being not the lowest |
Tender Value
₹16.4 L
EMD Value
₹32,800
Closing Date
27 May 2021, 6:00 pmClosed
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I)(CG) Military Engineer services Second Floor CG DHQ No 5(TN) No 4 and 4 A Clive Battery complex Rajaji Salai Chennai 600001
Comprehensive maintenance Repairs renewal replacement of defective part lifts of ECE make at CGRA Thalakancherry Phase I under GE (I) (CG) Chennai
2021_MES_435427_3
8861/GE(I)CG
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹32,800
Yes
18 Jun 2021
12 May 2021
29 May 2021
12 May 2021
27 May 2021
15 May 2021
Amount
SCHEDULE 'A' - PART I (MAINTENANCE)
Comprehensive Maintenance and repairs of electrically operated lifts of ECE Make 07 Nos at CGRA Thalkancherry including renewal/replacement of defective parts of Automatic Rescue device and over load warning device with a capacity of 10 passengers lift , 680 kg each-07 Nos for 6 stops/6 landings ,1.0 metre/Sec ,single speed single push button control system with micro processor control system by employing 01 No of lift mechanic and 01 No of trained and qualified electrician for mainenance of Lifts with collective control scheduled in Appx A by carrying out periodical checks , repairs and testing as per Proforma no :01 to 05 as recommended by the manufacturer to ensure smooth functioning and efficient operation including fixing only for the items mentioned below in schedule A part II ..
Comprehensive Maintenance and repairs of electrically operated lifts of ECE Make 2000 KG capacity Goods Lift ,07 Nos at CGRA Thalkancherry including renewal/replacement of defective parts of Automatic Rescue device and over load warning device with 2000 kg each-07 Nos for 6 stops/6 landings ,0.50 metre/Sec ,single speed single push button control system with micro processor control system by employing 01 No of lift mechanic and 01 No of trained and qualified electrician for mainenance of Lifts with collective control scheduled in Appx A by carrying out periodical checks , repairs and testing as per Proforma no :01 to 05 as recommended by the manufacturer to ensure smooth functioning and efficient operation including fixing only for the items mentioned below in schedule A part II ..
Note for item No 2 &3 mentioned above : (i) The contractor shall enter into a MOU with the OEM for Maintenance and repairs of the above work at site. (ii) The spares/electrical items as listed in Schedule A Part-II will be used whenever required only and measured and paid seperately under respective items. (iii) The rate quoted by the contractor above is inclusive of all items required at site except those items given in Sch A Part II to keep the lift operational round the clock including cleaning and greasing all moving parts on monthly basis (iv) If spare parts of original make is not available in the market ,necessary equivalent suitable spare to existing lift part as approved by the department shall be used in the work for smooth running of lifts. (v) Cost of renewal of lift license from Lift Inspector ,Govt of Tamil Nadu is deemed to be included in the rate quoted by the tenderer for item no :2 & 3 mentioned above.
SCHEDULE 'A' - PART II ( SPARE PARTS)
Supply only mother board APCLD R 4 Make ECE
Supply only Doordrive PKS 16 Make ECE
Supply only Maindrive for 10 passanger lift make Yashkawa
Supply only Door motor make ECE
Supply only Door lock contact make ECE
Supply only Landing / Car door shoe make ECE
Supply only Door bearing make ECE
Supply only Break arm make ECE
Supply only Break pad make ECE
Supply only Break drum make ECE
Supply only Limit switch make ECE
Supply only Jc switch make ECE
Supply only Reed switch make ECE
Supply only Gear oil EP 460 make servo
Supply only VFVR Relay card , DC 24/110V make ECE
Supply only Transformer for controller T-500 input 230V AC output 90/20 V ac make ECE
Supply only OEN Relay DC 24V make Sallzer
Supply only Contactor assembly 4 pole DC 110V 32 Amps with Auxiliari contact Make :Siemen / ABB
Supply only SMPS Input 230V AC output 54V DC
Supply only VMVFCard DC 24V make ECE
Supply only Micro card for automatic rescue device Make Jeltron
Supply only Charger Card for automatic rescue device Make jeltron
Supply only Converter Card for automatic rescue device Make Jeltron
Supply only Transformer for automatic rescue device input 230V Output 12/110V DCand 230V AC
Supply only Six Relay Card DC 24V Make : ECE
Supply only Twelve Relay Card DC 110V Make : jeltron
Supply only MCB DP 20 Amps Make : Schneider
Supply only Full length sensor (Make Meco) Suitable for 10 passanger lift Make ECE
Supply only Floor Position Indicator Card Make ECE
Supply only illuminated Bush Button Working on DC 24V Make ECE
Supply only SS indicator Plate 1.5mm thick suitable for Full Collective lift Electronic Car Position Indicator make ECE
Supply only Auxillary Contact Coil 32 Amps With 4Nos NC AC 230V Make : Siemen / ABB
SCHEDULE 'A' - PART III
Taking down Main motor 3 phase 380 Volts, up to 09 KW, 1300/325 RPM and Material and labour for rewinding the same using suitable gauge of copper winding wire and all insulation item including varnishing drying and refixing of AME at site testing and incluing replacement of any minor parts if necessary including fixing of new nuts and bolts for foundation etc complete all as specified and as directed.
Taking down Main motor 3 pohase 380 Volts, up to 15 KW, 1300/325 RPMand Material and labour for rewinding the same using suitable gauge of copper winding wire and all insulation item including varnishing drying and refixing of AME at site testing and incluing replacement of any minor parts if necessary including fixing of new nuts and bolts for foundation etc complete all as specified and as directed.
Taking down cabin fan single phase, 230Volts and Material and labour for rewindingthe same using suitable gauge of copper winding wire and all insulation item including varnishing, drying and refixing of fan in lift cabin and testingcomplete all as specified and as directed.
Rewinding of break coil including opening and cutting old brunt out winding and Material and labour for rewindingthe same using suitable gauge of copper winding wire and all insulation item including varnishing, drying and refixing in same position and testingcomplete all as specified and as directed.
Supply and fix LED light fitting 4 feet white, 20W, integrated LED driver etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and as directed. Make:- Philps Cat Part No. BN021C LED20S PSU CDL GR or M/S Wipro Cat Part No D 532065 20W-6500K
Supply and fix light fitting 2 feet white, 10W, integrated LED driver etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and as directed. Make:- Philps Cat Part No. BN 021 LED10S- 6500 PSU GR S1or M/S Wipro Cat Part No D 531065 10W-6500K
PREMIER ENGINEERING SYSTEMS
Man Elevators Company Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .