Closing Date
18 Oct 2023, 1:00 pmClosed
Superitending Engineer
EWC Agra
33 KV Line from 220 KV Sub Station POWER HOUSE in District Mainpuri
2023_DVVNL_838737_2
EWCA/T-05 (2023-24)
Open Tender
Electrical Works
Fixed-rate
90 days
Agra
as per tender specification
2 documents required · 2 mandatory
₹3,000
DVVNL
₹67,000
25 Oct 2023
30 Sept 2023
18 Oct 2023
30 Sept 2023
18 Oct 2023
30 Sept 2023
Amount
Part-A (Supply of Material) As per RESSPO Norms & Drawaing
M+6 G.I. Tower 19.300 Mtr. Long
33 KV Cross arm holding clamp with nuts, bolts & washers
" F " bracket for 33 KV line
" E " bracket for 33 KV line
Armour rod with ferrule for Dog conductor
G.I. Angle 65x65x6 mm, 4300 mm long for bracing with 4 nos clamps
G.I. Top Channel 125x65 mm, 3200 mm long with 2 nos clamps
G.I. Droper Channel 100x50 mm, 3000 mm long with 2 nos clamps
P.G. clamps for Reccoon/Dog
G.I. Nut, bolt with washer off size
G.I. Guarding Angle 65x65x6x2600 mm
G.I. Guarding Angle 65x65x6x3600 mm
Holding clamp for guarding angle with nuts & bolts
G.I. Barbed wire
G.I. Wire No. 16 SWG
G.I. Wire No. 6 SWG
G.I. Wire No. 8 SWG
Stone Pad (300x300x75 mm.)
33 KV Number plate with clamp with nuts, & bolts
33 KV Danger board with clamp with nuts, & bolts
Alluminium binding wire- 6 SWG
Alluminium paint
Red oxide paint
Turn Buckle
Eye bolt 12 x 110 mm
Clamps for fixing of cable and cable box
Supply of HDPE Pipe 160 mm dia PN-6, PE-100 Grade UV Stabilized
Clamps for holding of 160 mm dia H.D.P.E. Pipe
Cable marker
Wooden Bushes
Terminal Gantry
Structure for 33 KV Lightening Arrestor with plinth & foundation
Structure for 33 KV Line Isolator with plinth & foundation
33 KV Post Insulator
Structure for 33 KV Post insulator with plinth & foundation
Stay Rod 20×1800 mm
Stay wire 7/8 SWG
Stay insulator
Stay clamp with bolt, nut & washer
M.S. earthing Rod of 20 x2500 mm and 6 SWG earthing wire etc.
Sub Total of Part-A (Supply of Material)
Part-B (Erection Work) As per RESSPO Norms & Drawaing
Carriage of following material from Center Store to Site (i) 9.0 Mtr. P.C.C. Pole
(ii) 11.0 Mtr. S.T.P. Pole
(iii) 13.0 Mtr. S.T.P. Pole
(iv) 33 KV Lightening Arrestors, 33 KV Line Isolator, 33 KV Cable, Outdoor jointing kit, etc.
(v) ACSR Dog Conductor
(vi) Other line materials
Erection of Single Pole on 9 Mtr. Long PCC Poles
Erection of Single Pole on 11 Mtr. Long SP-55 poles
Erection of Single Pole on 13 Mtr. Long SP-72 poles
Erection of double Pole on 9 Mtr. Long PCC Poles.
Erection of double Pole on 11 Mtr.SP-55 Poles Double Pole support for cable x-ing
Erection of Tri Pole on13 Mtr. Long SP-72 poles
Assembling and installation of M+6 Tower as per drawing and grouting of M+6 Tower complete in all respect.
Errection and grouting of stay rods 1800 x 20 mm. including all works of excavation, fixing, tightening & nozzling of stay with the poles and of required tension as per relevant drawing including back filling of earth and proper ramming.
Earthing of supports with M.S. Earth Rod 2.5 Mtr. in length including excavation of pit and driving M.S. Rod to proper depth and connecting the earth electrode with the help of G.I. Wire 8 SWG, Nuts & bolts and earthing lugs.
Laying, spreading, lifting and final sagging of ACSR Dog Conductor in accordance with profiles and sag chart including binding, jumpering and fixing of all accessories in 3 Nos. conductor in parallel.
Fixing of cross bracing sets from M.S. Angle 65 x 65 x 6 / 50 x 50 x 6mm including cutting, drilling holes and providing M.S. Bolts of required size as per relevant drawing.
Providing and Fixing of danger board at each location as per relevant drawing.
Providing and Fixing of number plate at each location as per relevant drawing.
Providing and Fixing of Barbed wire on each pole as per relevant drawing.
Painting of Pole from top to galvanized portion with one coat of ready mix primer and Two coats of red paint. a) 11 Mtr.SP-55 poles
b) 13 Mtr.SP-72 poles
The Grouting and making of plinth of the support (1/6 of the full length of the supports) will be done as per norms in the CC 1:4:8 with cement, course sand and brick ballast including back filling and proper ramming.fixing of all clamps and other accessories as per relevant drawing. i) 9 Mtr. Long PCC Poles
ii) 11 Mtr. Long SP-55 poles
iii) 13 Mtr. Long SP-72 poles
Guarding between two poles like Single / Double / Tri / Four poles etc. to guard L.T. / 11KV/ Telephone lines, Road / River Crossing etc. with G.I.Wire 6 SWG and G.I. Wire 8 SWG including fixing of guarding channel with clamps and nuts & bolts etc. as per relevant drawing.
Continuous Guarding between two poles like Single / Double / Tri / Four poles etc. to guard L.T. / 11KV/ Telephone lines, Road / River Crossing etc. with G.I.Wire 6 SWG and G.I. Wire 8 SWG including fixing of guarding channel with clamps and nuts & bolts etc. as per relevant drawing.
Making H.T. Connection of the proposed line, on to the existing 33 KV bay/ Line from where line is emanating and another at 33 KV Sub-Station. The work consists of fixing of tension fitting Insulators, Jumpering, Clamping and binding etc. at the end as per site conditions.
Choping of branches of trees such as Eukeyleptus, Neem, Kedar and other kind of trees along the route of the line and disposal of the same at suitable place.
ERECTION & GROUTING OF TERMINAL GANTRY STRUCTURE:- The work incudes fabrication of Terminal gantry 8.23 Mtr. Long as per drawing No. RES.38. Digging of Two Nos. pits of size 2.2 mtr. X 1.4 mtr. X 0.75 mtr. Providing stone pad at the bottom of the trench and grouting of the two legs of the terminal gantry in CC ( Cement,Coarse sand and Stone grit of 20 mm gauge.) in the ratio 1:3:6 including supply of all T & P, shuttering etc. in a block of size 2.2 mtr. x 1.4mtr. x 0.75mtr. The work consists of dragging, shifting up to 40 Mtrs, raising and erecting the two fabricated legs of terminal gantry in proper alignment, level and plumb. Both the plinths of the terminal gantry shall be properly finished with champering of edges.
ERECTION & GROUTING OF ISOLATOR STRUCTURE:- Fabrication of isolator structures 3.5 Mtrs. in height as per drawing No. RES.39. Digging of two No. Pits of size 1.075 x 0.9 x 0.3 Mtr., providing stone pad at the bottom of the pit and grouting of two legs of the isolator structure in CC ( Cement, Coarse sand and stone grit of 20 mm gauge ) of ratio 1:4:8 in block of 1.075 Mtr. x 0.9 mtr. x 0.3 mtr. including supply of all T&P complete in all respect. The work includes dragging, shifting upto 40 meters, raising and erecting the two legs with runner of isolator in proper alignment, level and plumb. Both plinths of the isolator structure shall be properly finished with champering of edges.
ERECTION & GROUTING OF POST INSULATOR STRUCTURE/ LIGHTENING ARRESTOR STRUCTURE:- Fabrication of Post Insulator / lightening Arrestor Structure as per drawing No. RES. 39. Digging of two No. Pits of size 1.075 x 0.3 x 0.3 Mtr., Providing stone pad at the bottom of the pit and grouting of two legs of the above structures in CC (Cement, coarse sand and stone grit of 20mm. gauge) of ratio 1:4:8 in block of 1.075 Mtr. X 0.3 Mtr x 0.3 Mtr. including supply of all T&P complete in all respect. The work includes dragging, shifting up to 40 Mtrs., raising and erecting the two legs with top frame above structure in proper alignment, level and plumb. Both plinths of the structures shall be properly finished with champering of edges etc. This work also includes providing, fabrication and erection of 3 Nos. M.S. Plates of size 300 x 450 mm., 10mm. thick for each set of post insulator / Lightening arrestor.
INSTALLATION OF ISOLATORS:- Assembling and installation of line/ bus isolator on the isolator structure. Adjusting of operating mechanism in proper alignment so as to ensure smooth operation of the same. In case of line isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required.
INSTALATION OF POST INSULATOR/ LIGTHENING ARRESTOR:- Installation of 3 Nos. post insulators / lightening Arrestors on the post insulators structure. The work includes fabrication for proper fixing if required.
Making vertical / Horizontal jumper connection through Panther to Dog/ Dog to Dog P.G. Clamp from 33 KV bus bar to Terminal Gantry through Line Isolator, Post Insulators & Lightening arrestors etc.
PAINTING OF STRUCTURE:- Painting of the following structure with two coats of Aluminium paint of good quality including cost of material, Labour & T&P complete in all respect. (A) Termanal Gantry
(B) Isolator Structure.
(C) Post Insulator Structure / Ligthening Arrestor Structure.
Providing & laying of G.I. earth Strip of size 50 x 6 mm. for connecting the earth mat with the super structures at two points, security fencing posts, including, digging of trench 500 x500 mm., bending, cutting, straightening and welding of the earth strip with the earth mat and various steel structures using high quality arc welding. The work includes proper overlapping of the strip and jointing by welding.
Painting of earth strip of size 50 x 6 mm., with one coat of ready mixed primer followed by two coats of synthetic enamel paint of Bus green colour including supply of all material.
Laying of 33 KV Power cable 3 x 300 Sq.mm XLPE through 160 mm dia H.D.P.E. pipe (ISI Mark) 2.5 Meter below ground level by way of boaring/drilling by HDD Method (Trenchless System) across the Railway Track and providing Cable Marker & Wooden Bushes with complete Job. (109.0 ) x 2 = 218 Mtr.
Laying of 33 KV power XLPE 3 x 300 Sq.mm Cable without pipe in loop out side the Railway boundary by excavation of trench as per Resspo norms below ground level ( as per approved drawing of the Railways) including laying of bricks to cover the cable in the cable trench and back filling of earth, ramming and proper dressing (12.0 + 12.0 ) x 2 = 48 Mtr.
Filling of 33 KV out door type heat shrinkable cable jointing kit at the end of cable by plumbing and tapping of cable. Fixing and clampling of proper size and good quality lugs, after providing 3.00 Mtr. long H.D.P.E. pipe 160-mm dia over the 33 KV Power Cable as above Ground Level complete work including cost of insulation tapes lugs, Pipe etc. other than jointing Kits. ( 3+3 ) x 2 = 12 Mtr.
Lifting, mounting/ Fixing and clamping of 33 KV Cable with cable joining kits on already erected Double Pole Structure and making connections with over head line. The work includes the sealing of H.D.P.E. Pipe top. The lower end of the pipe is to be burried into the earth by about one feet.(8+8) x 2 = 32 Mtr.
Railway crossing documentation and pursuance fee etc. required for optaining permission from Railway department. (Actual fee paid by contractor to Railway department will be reimbursed by D.V.V.N.L.)
Sub Total of Part-B (Erection Work)
Grand Total of (Part-A & Part-B)
Note: GST shall be paid Extra
ALOK ENTERPRISES
M/S AARADHYA AND ADHYATM ASSOCIATES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .