Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-Finance | ₹8.4 L | L1 | Accepted-Finance lowest bidder |
| 2 | L2₹8.7 LRejected-Finance | ₹8.7 L | L2 | Rejected-Finance bidder is not L1 |
| 3 | L3₹9.2 LRejected-Finance | ₹9.2 L | L3 | Rejected-Finance bidder is not L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Requested documents not submitted |
Tender Value
Refer Docs
EMD Value
₹20,952
Closing Date
10 Dec 2025, 11:00 amClosed
EE-l CKHED PWD
Central Kolkata Health Electrical Division P-12, C.I.T Road(1st floor) Kolkata
Re-wiring the E.I. Work in existing position, dismantling, and refixing of 3 Nos 7.5TR Concealed Split AC units , fire detection and alarm system, audio-video and public address (PA) systems, along with other electrical accessories at ELT CNMCH
2025_WBPWD_949517_1
WBPWD/EE-I/CKHED/eNIT62/25-26
Open Tender
ELECTRICAL WORKS ORG
30 days
NMCH
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,952
Central Kolkata Health Electrical Division
3 Feb 2026
14 Nov 2025
12 Dec 2025
14 Nov 2025
10 Dec 2025
26 Nov 2025
19 Nov 2025
Distn wiring with 3x1.5 mm² PVC insulated unsheathed Cu wire (Finolex/Polycab /Bonton) in 20mm dia PVC rigid conduit pipe (Precision-MMS) to L. & F. point complete with 6A Piano Key Switch on 16 SWG CRC sheet metal M.S. Box with 3mm thick Bkt top cover & 3 nos. copper connecting Bars fixed on Bkt chair inside, with earthing attachment on wall & mending good damages as per direction of the E.I.C. Av. Run 8 Mtrs.
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) singlecore str-anded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/R R Kabel/Havells) in 20mm size PVC rigid conduit 'FRLS'(Precision MMS) with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm)single core stranded 'FRLS' PVC insulated & unsheathed copperwire as ECC, to 5A 3 pin flush type plug socket & Piano Keytype switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/ Pers-pex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish. a) on board.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/63 protection, with DP isolators as incomer and SPMCB ('C' Curve 10KA) as outgoing,fixing at flat iron frame on wall &mending good the damages to original finish; inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. i) (2+10) Way,with S&F 240V 40/63 Amps DP MCB isolator as incomer and 240V 6-32A SPMCB of Breaking capacity 10KA & C characteristics 10 nos as outgoing, 2+10 Way (Legrand/Schneider/Siemens)
Supply and Fixing of 4 feet Industrial box type twin LED tube fitting incl. Supply & Delivery of 2 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 105 Lm/ Watt or better & 50,000 LED burning hours or more,as directed by EIC. [Mal{e- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply and Fixing of 4 feet Industrial box type single LED tube fitting incl. Supply & Delivery of 1 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Fixing only single/twin LED light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed by 2 nos steel bullet fastner nut-bolt and other side connected with the suitable size of bolts and nuts incl. S&F EI conduit “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated Cu flexible wire , ceiling plate, ceiling rose where it is required and mending good damages to original finish and painting etc.
Supply 415V Timer DB (equivalent to 12 way SPN DB in size) with steel sheet enclosure ,3 ph power contactor,not less than 63 A for 63 A incomer,indication lamp for ON/OFF,analog astronomical switch,15 min TPNMCB-415V ,63A-01 no,concealed / surface mounted on flat iron legs in/on wall incl. necessary iterconnection with copper wire and mending good the damages to original finish as per direction of E.I.C.(Siemens/ABB/L&T),
Supp ly & Delivery of 240V recess mounted 1' x 1' LED down light having 15watt in white powder coated pressure diecast aluminiu m housing, wi th glare free uni form ill umination, suitable for 1' x 1' grid ceiling with CCT (57 00 K- 6500K ) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NAB L accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply & Fixing of 230V, 50Hz, 450 mm sweep heavy duty full metal body bracket fan having wattage 90 Watt, RPM,1350, Air Displacement(In CMM) -100 complete with a ll accessories. (Make - Orient/Crompton/ EPC) [BEE star rated]
S/D following sizes PVC insulated Cu wire (Finolex/Polycab/RR Kable) in 20mm dia PVC rigid conduit pipe (Precision) to power points as follows incl. making connections as to G.S.:-
3 x 1.5 mm² in 20mm dia PVC rigid conduit pipe
2 x 2.5 & 1x 1.5 mm² in 20mm dia PVC rigid conduit pipe
2x6 & 1x4 mm² in 20mm dia for SPNDBs
4 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) For AC
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 x 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 2 x 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl.S&F switch board and cover plate and making necy connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 3 nos. 6 A + 1 No. 16A 3/5 pin Modular type plug socket with 3 nos. 6 A + 1 No. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board, blank Plate and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & fixing 4 pole MCB enclosure with 1no. 415V 40 Amp 4-pole MCB(Legrand) to be fixed concealed in wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment as per direction of E.I.C (Non schedule)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Dismantling the existing LED 2'×2' recessed light fittings (36 Nos), single/double T8 lamps with mounting rails (24 Nos), round recessed fittings (32 Nos), footlight fittings (22 Nos), and 16" wall bracket fans (16 Nos), along with the associated wiring (wires, conduits, switch sockets, etc.), carefully using the contractor’s own tools and tackles from their existing positions, and transporting the same to the section office for future use, as directed by the EIC
Dismantling of 09 Nos. main IDU units, each of 2.5 TR capacity, from the 3 × 7.5 TR concealed split (HAT) air-conditioning system, along with hanging tie rods and grouted angle iron frames, including refrig-erant pipelines and electrical cable connections, after disconnecting from both IDU and ODU, carefully using the contractor’s own tools and tackles from their existing positions, and transporting the same to the section office for future use. The work also includes filling any unwan-ted wall openings with sand and cement mortar, as directed by the EIC.
Cost for thorough cleaning by carefully scrubbing with brushes of diffe-rent grades by skilled labour, including cleaning of condenser and cool-ing coils of split units using water jet pressure and appropriate chemic-als cleaning of heat exchangers, axial and centrifugal fans; and reas-sembling the units after complete removal of dust and chemicals. The cleaned machines are to be kept in the sectional store.
Installation, Testing & Commissioning of 7.5 TR HAT type AC Indoor & Outdoor unit of the following capacity concealed type Split Air Conditioners after making hole in wall & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant as per the manufacturer specifications, S&F of necessary fixing arrangement for indoor duly painted etc as per direction of the EIC.
Copper Refrigeration pipe line with 0.6 mm(min) & 0.7 mm (min) thick for liquid and suction line with fittings, elbows, bends, supports & brackets with pipe insulation. (Make-Ryoku/Totaline/Jobu/Nippon)
Liquid Line (3/8" OD or as per manufacturer specification)
Suction Line (5/8" OD withor as per manufacturer specification)
Supply and laying 4 core 2.5 sq mm control copper cable (PVC insulated & unshethed,un-armoured) from Condensing Unit to IDU control panel (Make: Gloster/Havells/RR Kable /Finolex/ Polycab)
Supply and laying of Drain Water piping work out of UPVC hard pipes of following sizes incl. nitrile insulation with fiting accessories bends, elbows, tees flanges, tapings, wall sleeves hangers, supports, anchors etc. as required.(Make : Supreme / Astral/ EIC approved). 25 mm dia.
Supply & charging Refrigerant-R410
Supply and fixing of AI powder coated continuous Grill (Make- Premier, Dynacraft/ EIC approved.)
Charges for drop ceiling to cover the indoor units made of gypsum.
Charges for trap door made of aluminium channel & ply wood for IDU maintenance.
Dismantling of the existing Public Address System, Conference System, and associated audio, video, and communication equipment such as projector, 12' × 9' motorised screen, 4 Nos. of 55" TV units, 8 Nos. of sound boxes, sound mixer, microphone stands, console, etc., along with the associated wiring (wires, conduits, etc.), carefully using the contractor’s own tools and tackles from their existing positions, and transporting the same to the section office for future use, as directed by the EIC.
Only installation charges of existing wireless LCD Projector for Eastern Lecture Theatre (Make: Panasonic PT-Ez 590)
Only installation charges of existing projector motorized screen (9' x12') for two Lecture Theatre [ Make : Liberty]
Supply & installation of Mixer Table( make: Customized)
Supply & installation of 3 KVA online UPS (Make- Emerson/Numeric) with of 12 Volt 26 AH SMF VRLA Batteries (Approx 30 Minutes Backup Time) and Battery Rack & inter connection as required.
Supply & installation of 15U Rack with Accessories(make :D-Link)
Supply & installation of 139 cm (55 inches) 4K Ultra HD Smart OLED Google TV having 4HDMI Ports & 2USB Ports, 20 Watts Speaker & Full function Remort, Power cord etc. ( Make - SONY, K55S30/ equivalent to Sumsung.)
Labour Charges for entire Testing & Commissioning work to ensure the functionality of the AV System as directed by EIC
Dismantling of existing multi-sensor smoke detectors, response indicators, along with the associated wiring (wires, conduits, etc.), after carefully disconnecting them from the existing fire panel using the contractor’s own tools and tackles, and transporting the same to the section office for future use, as directed by the EIC.
Supply, installation, testing & commissioning of EN Standard, VDS approved Addressable Dual Optical Smoke cum Heat type Multi-Sensor Detector with inbuilt / equal number of additional Isolator for each detector and integral LED status indicator with 360 degree viewing angle. Detector shall communicate for differentiated alarm activation and high tolerance to dust,dirt, temperature fluctuations and air currents. Detector should have unquie address for communication and assigned through panel with Mounting Base as required. (Approval standards:VdS, EN54; Approved Make: Esser by Honeywell/)
Supply, installation, testing & commissioning of EN Standard, VDS approved Inteliigent addressable manual call point with inbui
lt / equal number of additional Isolator for each manual call point suitable for flush or surface mounting, call point shall include test key feature without removing the glass. (Approval standards:VdS, EN54; Approved Make: Esser by Honeywell)
Supply & Drawing of 2 Core 1.5 sq.mm FRLS copper Cable. (Make. Finolex / Technoflex /Polycab) with 20 mm FRLS PVC rigid conduit pipe on the surface of the wall. (Make: Precisson Medium).
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.20 MB
BOQ_2263982.xls
BOQ • 0.26 MB
2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid