| 1 | L1₹18.7 LAccepted-AOC | ₹18.7 L Quoted ₹19.0 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹19.7 L+₹74,231.53 (3.91%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | ₹19.7 L+₹74,231.53 (3.91%) | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹19.9 L+₹89,530.03 (4.72%)Rejected-Finance | ₹19.9 L+₹89,530.03 (4.72%) | L3 | Rejected-Finance Being not lowest |
| 4 | L4₹20.0 L+₹1.0 L (5.29%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹20.0 L+₹1.0 L (5.29%) | L4 | Rejected-Finance Being not lowest |
| 5 | L5₹20.4 L+₹1.5 L (7.65%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹20.4 L+₹1.5 L (7.65%) | L5 | Rejected-Finance Being not lowest |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
12 Aug 2020, 6:00 pmClosed
CWE (AF) Gurgaon
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-110010
REPAIR REPLACEMENT OF HT LT U G CABLE LT PANELS ELECTRICAL APPLIANCES AT SUB STN TRANSFORMER UPTO 2 MVA CONTROL SWITCH GEAR LIGHTENING CONDUCTOR EARTHING SECURITY LIGHT AND CONNECTED ITEMS AT AF STN INDUAR UNDER AGE E M RAJOKRI UNDER GE AF GURGAON
2020_MES_360526_2
CA NO CWE/GGN/G-13/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Rajokri
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Gurgaon
₹57,000
Yes
3 Sept 2020
29 Jul 2020
14 Aug 2020
29 Jul 2020
12 Aug 2020
31 Jul 2020
Amount
M&L for Dehydration including filtration and cleaning of Transformer oil by dehydrating machine incl testing of sample before and after dehydration and filtration and replacement of silica gel complete all as specified and directed. NOTE:- Contractor has to arrange the dehydration machine and testing kit without any extra cost to the dept. Test report to be submitted after completion of job.
Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and directed. NOTE:- Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site
M&L for defect rectification of HT 11 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pules, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 11 KV / 1.1 KV complete all as specified and directed
Supply, jointing and testing Straight through cable joint heat shrinkable including all material and accessories suitable for 3.5 core X 25-95 Sqmm XLPE cable of 1100 volts (E)grade complete all as specified and directed. Note : Cost of Prepration of existing end deemed to be included in unit rate.
Same as item No 4.00 but size 3.5 core X120sqmm- 185 sqmm
Same as item No 4.00 but size Above 3.5 core X185sqmm
Supply, jointing and testing indoor type Heat shrinkable end termination cable joint including all material and accessories suitable for 3 core X 120-185 Sqmm XLPE cable of 11000 volts (E)grade complete all as specified and directed. Note : Cost of cutting of existing end termination joint deemed to be included in unit rate.
Supply, jointing and testing Outdoor type Heat shrinkable end termination cable joint including all material and accessories suitable for 3 core X 120-185 Sqmm XLPE cable of 11KV/33KV (E)grade complete all as specified and directed. Note : Cost of cutting of existing end termination joint deemed to be included in unit rate.
Supply, jointing and testing Straight through cable joint Heat shrinkable including all material and accessories suitable for 3 core X 120-185 Sqmm XLPE cable of 11000 volts (E)grade complete all as specified and directed. Note : Cost of Prepration of existing end deemed to be included in unit rate.
Supplying and laying in repair XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electrical power cable ( heavy duty ) with aluminum conductor, 11000 volts grade cross sectional area 185 Sqmm x 3 core complete all as specified and directed
Supply Only Rubbre hand Gloves suitable for 33 KV system complete all as specified and directed.
M&L for taking out VCB trolley from HT control panel 33 KV 3 phase 1250 Amp , 31.5kA (Make :- Siemens) and cleaning the trolley with CRC removing all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders complete all as specified and directed.
Material and labour for calibration of IDMT numerical relay as per existing load for earth fault , over current and short circuit ,including setting the relay on required electric load and testing on earth fault and short circuit and over load with the help of relay testing kit for 33 KV system complete in all respect complete all as specified and directed.
S&F in replacement VCB spring Charging motor Voltage 201-500 V 400mA complete all as specified and directed. Make Schneider or Equvalant in ABB
Supply and fixing in replecement of Multi function meter for 33 KV/11KV VCB panel complete all as specified and directed.
M&L For taking out VCB trolley from HT control panel 11 KV 3 phase 630 Amp , 21 kA (Make :- Siemens) and cleaning the trolley with CRC removing all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders complete all as specified and directed.
Material and labour for calibration of IDMT numerical relay as per existing load for earth fault , over current and short circuit ,including setting the relay on required electric load and testing on earth fault and short circuit and over load with the help of relay testing kit for 11 KV system complete in all respect complete all as specified and directed.
M&L for comprehensive maintainance of 11 KV HT RMU Panel 1 VCB & 2 Load Break switch Rated current 630 amp, 12 KV outdoor/ indoor type by isolating ,disconnecting of input/output ,supply cable, detecting of fault, u/s component etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts etc, if required complete all as specified and directed.
M&L For taking out ACB trolley from LT control panel 415 V 3 phase 800 Amp , 50 kA, 4 Pole (Make :- schneider) and cleaning the ACB with CRC removing all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders complete all as specified and directed.
M&L For taking out ACB trolley from LT control panel 415 V 3 phase 400 Amp , 50 kA, 4 Pole (Make :- schneider) and cleaning the ACB with CRC removing all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders complete all as specified and directed.
Supply and fixing in replecement of transformer protection realy (oil temp/ winding temp/ buchholz ) Mountefd on 33 KV/11KV VCB panel complete all as specified and directed.
Supply and fixing in replecement of Closing spring for 33 KV/11KV VCB panel complete all as specified and directed.
Supply and fixing in replecement of Closing/ triping coil for 33 KV/11KV VCB panel complete all as specified and directed.
Supply and fixing in replecement of Spring charging Gear for 33 KV/11KV VCB panel complete all as specified and directed.
Supply and fixing in replecement of thermostat for 33 KV/11KV VCB panel complete all as specified and directed.
Material and labour for calibration of ACB relay as per existing load for over current and short circuit ,including setting the relay on required electric load and testing on earth fault and short circuit and over load with the help of relay testing kit for LT system complete in all respect complete all as specified and directed.
Supply & Fixing in replacement of ACB rated current 800 Amp at 40⁰ C , Rated insulation Voltage 1000 V AC 50 Hz, Rated operational Voltage 690 V 50 Hz, CT Rating 800 Amp, 4 Pole,Bracking Capacity 50 KA , Utilaization Category 'B' ,Short Circuit Capacity 105 kA , Short Time with stand Current 50 kA- 1 Sec,42kA- 1Sec , 25 kA -3 Sec, 50 Hz, Conforming to IEC60947-2, complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 300Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
Same as item No 28.00 but size 3.5 core X 185 sqmm
Same as item No 28.00 but size 3.5 core X 95 sqmm
Same as item No 28.00 but size 3.5 core X 50 sqmm
Same as item No 28.00 but size 3.5 core X 35 sqmm
Same as item No 28.00 but size 4 core X 25 sqmm
Same as item No 28.00 but size 4 core X 16 sqmm
Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out complete all as specified and directed.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
M&L for boring/auguring suitable hole & insertion of 65 mm dia GI pipe including pipe not less than 600 mm below existing PCC/road/hard standing complete all as specified and directed. Notes :- (a) Cost of equipment, tools & plants & material required for boring shall be deemed to be included in the rates quoted.
Supply and laying sand cushioning for cable protection in trenches complete all as specified and directed.
Supply and laying un-reinforced precast concrete LV cable cover class Type I with 250 X 150 X 40 mm, complete all as specified and directed.
Taking down the existing cables from trenches of any size complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode size 600 x 600 x 6mm thick burried directly in ground vertically not less than 2.25m below normal ground level with the top edge of the earth plate not less than 1.5 m below the normal ground level surrounded from all sides by mixure of charcoal and common salt and electrode connected to and including galvanised iron earth strip25x4mm means of galvanised iron bolts, nuts, check nuts and washers and earth strip protected by galvanised iron pipe 40mm dia bore light grade with all fittings from top edge of earth plate to body of equipments fixed with and including mild steel clamp made out of FI 32x6mm and also including provision of GI pipe 20mm dia bore medium grade for watering including test point 75x75x25mm all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, funnel including 40mm thick RCC slab cover and testing on completion complete all as specified and directed. NOTES: (i) Value of earthing should be less than 1 Ώ (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) PCC pits extra cost of addtional length of watering pipe, bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length GI earth strip 25x4 mm.
Comprehensive maintainance of transformer of 2 MVA, 33 KV/ 11KV by isolating ,disconnecting of input/output ,supply cable,opening of top of transformer,detecting of fault ,u/s component etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts if required etc from authorised rep or service engineer from the manufacturer complete all as specified and directed. Make : Kirloskar. Note : contractor should submit MOU of OEM with authorised service engineer.
Comprehensive maintainance of transformer of following capacity 11 KV/ 415 V by isolating ,disconnecting of input/output ,supply cable,opening of top of transformer,detecting of fault ,u/s component etc,cleaning of serviceable parts/ component ,including replacement of worn out spare parts if required etc from authorised rep or service engineer from the manufacturer all as specified and directed. Make : Kirloskar. Note : contractor should submit MOU of OEM with authorised service engineer.
Transformer 1200 KVA
Transformer 500 KVA
Transformer 450 KVA
Transformer 250 KVA
Material and labour for replacement of existing unserviceable disc type insulator porcelain vitreous 145 mm height and 255 mm dia ball and socket type white brown or green with tension clamp for conductor working pressure 11000 volts complete all as specified and directed.
M&L for maintain earthing pit complete with tacking out galvanized steel earth plate electrode & refix in ground burried directly in ground vertically not less than 2.25m below normal ground level with the top edge of the earth plate not less than 1.5 m below the normal ground level by filling surrounding all sides by fresh mixure of charcoal and common salt and earth enhancing material to obtain efective result without replacing earth electrod & conect with earth strip means of galvanised iron bolts, nuts, check nuts and washers and earth strip protected by galvanised iron pipe 40mm dia bore light grade with all fittings from top edge of earth plate to body of equipments fixed with and including mild steel clamp made out of FI 32x6mm and also including provision of GI pipe 20mm dia bore medium grade for watering all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, funnel including 40mm thick RCC slab cover and testing to get required result on completion of maintenace complete all as specified and directed. NOTES: (i) After maintenace of Earth pit Value of earthing should be less than 1 Ώ (ii)PCC pits extra cost of addtional length of watering pipe, bends elbows etc.shall be deemed to be included in the quioted rate.
Taking down and dismantling HPSV street light fitting for 70/150/250 watt capacity of any make/type from pole/GI pipe unserviceable items to be kept in safe custody and taken as credit complete all as specified and directed.
Taking down of worn out PVC insulated copper cable 1.5 sqmm from street light fitting to junction box including conduit pipe complete all as specified and as directed.
M&L for wiring PVC insulated, stranded sheathed copper cable conductor size 1.5 Sqmm 3 core and drawing through Pole or S&F steel rigid conduit not less than 20mm dia and fixed on pole includingincluding connecting to Bus Bar & earth dolly complete all as specified and as directed.
Supply and Fixing LED street light luminaire IP-66 grade of proterction with 24 High power LED of 45 watt rating and extendable upto 48 watt rating with unique peanut lens to ensure uniform distribution complete all as specified and as directed .
Supply and Fixing LED street light luminaire IP-66 grade of proterction with 24 High power LED of 70 watt rating with unique peanut lens to ensure uniform distribution complete all as specified and as directed .
M&L for bracket for street light fitting suitable for Octagonal Pole made of 40mm bore Medium grade GI tube bent to shape as required, fixed with and including bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete including taking down the existing bracket and refixing and connecting up the light fitting etc complete all as specified and directed.
Supply and fixing in repacement of Octagonal pole cable Connector isolation strip with 4 terminals & 6 Amp MCB including fixing with street light poles using necessary nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Make : Hensel/Sintex/Universal Switch Gear control Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection.
Supply and fix in replacement of automatic timer switch panel mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as specified and as directed. Make : Kakatiya/Healer/Bajaj. Note: (i) Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr deemed to be included in the unit rate. (ii) Provn of glands and lugs shall be deemed to be included in the quoted rate.
M&L for rewinding of fans with same gauge of super enameled copper wire complete varnishing ,baking ,connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nots /bolts/washer /split pin and blade screws etc testing ,complete all as specified and directed :-
(a) Ceiling fan 1200 /1400 mm sweep make:nbc
(b) Exhaust fan 300 mm sweep
(b) Exhaust fan 450 mm sweep
Supply and fix in repair new metal bush bearing made out of gun metal/brass of same size suitable for ceiling fans,wall mounted fan and exhaust fans complete all as specified and directed.
Supply and fix in repair ball bearing suitable for the following fans : make NBC/SKF/Tata
(a) Ceiling fan 1200 /1400 mm sweep make:nbc
(b) Exhaust fan 300 mm sweep
(c) Exhaust fan 450 mm sweep
Supply and fix in repair capacitor 2.5 mfd,400 volt ,50 hz all as specified and as directed.Make : Tibcon or equivalent.
Supply and fix in repair capacitor 4 mfd,400 volt ,50 hz all as specified and as directed Make : Tibcon
MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA
MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA
MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
MCCB 3 Pole, 415 V, Adjustable type, 320 Amps with breaking capacity 36 KA
supply & fix Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered Complete all as specified & directed
supply & fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size Complete all as specified & directed
Comprehensive maintenance of Main LT panel with inbuilt Capacitor bank & DG control panel by isolating ,disconnecting of input/output ,supply cable, detecting of fault ,u/s component in panel ,cleaning of serviceable parts/ component ,including replacement of worn out switches LED indicator, spare parts, Welding of Panel door & replacement of Door lock, replacement of old wiring with 2.5 sqmm to 6 sqmm etc, if required complete all as specified and directed. Replacement of Capacitor of verious size will be measured & paid separately
M & L for Earthing complete with Copper earth plate electrode 60cmx60cmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using Copper strip 20×3mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel, wire mesh and 40 mm dia GI protection pipe light grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified. NOTES: (i) Value of earthing should be less than 1 Ώ (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip. (iii) PCC pits extra cost of addtional length of watering pipe, bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length copper earth strip 20x3 mm.
Supply and fixing Air termination, single pointed, copper rod 24mm dia and 300mm long complete all as specified and directed.
Supply & fixing Lightening arrestor pole 3 mtr long, 80 mm GI pipe medium grade including Concrete work for fixing GI pole verticaly on roof complete all as specified and directed.
Supply and fixing Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Supply and fixing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled, screwed including 3 nos. 8mm dia 25mm long hex. head screw & brezing all joints complet all as specified & directed
Taking down Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed.
Taking down GI strip/ Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Taking down test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
S&F in repair of Warrior HD Plus Super heavy duty plus cylendrical capacitor with clamp 440 Volt , 50 Hz, Capacitor 5 KVAR complete all as specified and directed.
S&F in repair of Warrior HD Plus Super heavy duty plus cylendrical capacitor with clamp 440 Volt , 50 Hz, Capacitor 10 KVAR complete all as specified and directed.
S&F in repair of Warrior HD Plus Super heavy duty plus cylendrical capacitor with clamp 440 Volt , 50 Hz, Capacitor 15 KVAR complete all as specified and directed.
S&F in repair of Warrior HD Plus Super heavy duty plus cylendrical capacitor with clamp 440 Volt , 50 Hz, Capacitor 20 KVAR complete all as specified and directed.
S&F in repair of Warrior HD Plus Super heavy duty plus cylendrical capacitor with clamp 440 Volt , 50 Hz, Capacitor 25 KVAR complete all as specified and directed.
S&F in repair of Warrior HD Plus Super heavy duty plus cylendrical capacitor with clamp 440 Volt , 50 Hz, Capacitor 50 KVAR complete all as specified and directed.
S& F HT insulating SYNTHETIC rubber matting 2 m x 1m x12 mm thick complete all as specified and directed.
S&F Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom,class 9 including Neccesory PCC foundation and re-connecting HT 33 KV over head cable as it is complete all as specified and directed.
Material & Labour for dismantling of the exiting PCC pole/struts of any size complete all as specified and directed.
Compression/crimping type sleeve joints for jointing conductors/ jumper connections including treatment with conducting jelly for 33 KV HT conductor complete all as specified and directed.
Material and labour for cutting/trimming tree branches along the over head HT lines 33 KV up to 3.0 mtr from electric line on both sides of the span and disposing of the cut tree/branches at places from JVNL sub stn to Main Reciving Sub Station (23 KM) After shut down of supply & restore after Trimming complete all as specified and directed. Note :- (a) Cost of equipment, tools , plants, manpower & material required shall be deemed to be included in the rates quoted.
M&L For replacing Porcelain aerial fuses suitable for 33 KV up to 100 amp , with brass contact bolts and nuts complete all as specified and directed.
S&F in repair wall mounted TPN busbar chamber ,current rating 200 Amp,415,4 way complete all as specified and as directed.
S&F in transformer breathers sillica gel (orange) for effective beratheing & to protect transformer oil from moiture complete all as specified and directed.
Supply and fixing in replecement of Lead acid maintenance free Battry 12 Volts 7 AH of existing type & size suitable for VCB microtec power backup inverter complete all as specified and directed. Make : EXIDE/AMCO or equivalent including initial charging.
S&F LED indicator lamp for LT/HT panel (Red / Green/Blue/Yellow) complete all as specified and directed
Supply and fixing in replecement of 32 to 160 Amp, 415 Volts, 50 Hz Power contactor of coil voltage 240 Volts, complete all as specified and directed. Make: L&T/Schineider/Havells or equivalent.
Supply and Fixing in replecement circular LED Flood with innovative finless designand excellent indirect light IP-66 grade of proterction with LED 120 Watt with resistance to impact and corrosion. Glare free and better uniformity.Milky version .complete all as specified and as directed . Cat Part No. LFLN-90 cdl make of CG or its equivalent in Wipro/Phillips Note : Any reducer to suit the manufacturer mounting dia for fixing of fitting to existing bracket shall be deemed to be included in the rates quoted by the Contractor.
Material and labour for servicing of two pole, structure complete including replacement of unserviceable jumper, sleeve vice type connector GI Clamps 'T' connector run connector run through clamps, bolts nuts washer connecting lugs/thimbles knife, contacts applying petroleum jelly to the moving as well as fixed contacts, tightening all the connection for its smooth functioning and preparing old painted surface of the structure such as poles, cross arms, bracing and supports clamps back plate complete painting of one coats of anti corrosive aluminium paint complete all as specified and directed. Marking the pole No/feeder name with black colour synthetic enamel paint complete all as specified and directed. Note: No Extra payment will be made for the spares required to keep the two pole structure in satisfactory functioning state throughout contract period other then given in schedules.
Material and labour for servicing of four pole, structure complete including replacement of unserviceable jumper, sleeve vice type connector GI Clamps 'T' connector run connector run through clamps, bolts nuts washer connecting lugs/thimbles knife, contacts applying petroleum jelly to the moving as well fixed contacts, tightening all the connection for its smooth functioning and preparing old painted surface of the structure such as poles, cross arms, bracing and supports clamps back plate complete painting of one coats of anti corrosive aluminium paint complete all as specified and directed. Marking the pole No/feeder name with black colour synthetic enamel paint complete all as specified and directed. Note: No Extra payment will be made for the spares required to keep the four pole structure in satisfactory functioning state throughout contract period other then given in schedules
Material and labour for cutting, removing the vegetation growth and surface dressing all around the installation yard/transformer/LT panel Board areas external only to keep always installation clean and tidy. Note: All the installation yards/area shall be kept clean through out contract period repeatedly by removing the grass/shrubs as many time required depending on the growth of grass measurement will be measured and paid only once throughout contract period.
Supply and fixing female contact spring loaded having brass contacts suitable for GOD up to 1250 Amp for working pressure 33000 volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation complete all as specified and directed.
Supply and fixing male contact with arching horn having brass contacts suitable for GOD up to 1250 Amp for working pressure 33000 volts, galvanised iron bolts, nuts and washers for fixing with post insulator or any other indicated situation complete all as specified and directed.
Material and labour for replacement of HT metallic rod stud and nuts of existing size duly threaded made out of brass/gun metal up to 2 MVA capacity transformer 33/11 KV complete all as specified and directed.
Material and labour for replacement of LT/HT metallic rod stud and nuts of existing size duly threaded made out of brass/gun metal up to 1200 KVA capacity transformer 11/0.433 KV complete all as specified and directed.
Material and labour for stone graded course aggregate of 40 mm grade nominal size without any vegetation or chemical including leveling/spreading surrounding HT/LT 2/4 pole structure, LT/HT panel complete all as specified directed .
Net Contract Sum will be after deducting Sch of Credit of Rs 23838.00
Ridhi engineers and builders
TUSHAR ASSOCIATES
Commercial Traders
Shiv Enterprises
shiv shanker enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .