Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹7.9 L+₹808.80 (0.10%)Rejected-Finance NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L2 | Rejected-Finance Other than lowest Bidder | |
| 3 | L3₹8.0 L+₹11,530.80 (1.46%)Rejected-Finance | L3 | Rejected-Finance Other than lowest Bidder | |
| 4 | L4₹9.7 L+₹1.8 L (23.0%)Rejected-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L4 | Rejected-Finance Other than lowest Bidder | |
| 5 | L5₹9.8 L+₹1.9 L (23.9%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L5 | Rejected-Finance Other than lowest Bidder |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
15 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jalandhar Cantt
HQ CWE Nalwa Road Jalandhar Cantt Pin-144005
Please refer tender documents
2021_MES_437194_1
CA NO. CWE/JAL/K-06/2021-22 8321/06/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jalandhar Cantt
Class E Category b(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
Garrison Engineer Kapurthala
₹42,000
Yes
17 Jun 2021
19 Apr 2021
17 May 2021
19 Apr 2021
15 May 2021
10 May 2021
60 days
Amount
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for laying of under ground cable /foundation of poles/stays etc and getting out in soft/loose soil complete all as specified and directed. Note:- Excavation shall be carried out manually, due to constrain site use of JCB is not feasible.
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and depth exceeding 1.5 metre but not exc 3.00 mtr complete all as specified and directed.
Returning, filling in, any type of soil and spreading in layers not exceeding 25 cm thick including watering and well ramming all as specified.
Removal of surplus spoil ( any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
Material and labour for brick protection using old size sub class ‘B’ bricks, laid flat dry but jointed and laid length wise perpendicular to the axis of cable all as specified and directed by the Engineer-in-Charge.
Supplying, filling in trenches, spreading, leveling sand cushioning 8 cm below cable and 15 cm above the cable punned complete all as specified & directed Note : Punned sand will be considered for measurement
Material & Labour for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in mass foundation of pole, for stay and coping etc including necessary form work where required and fair finishing to the exposed surfaces complete all as specified and directed.
All as per description of seiral item No 7 here-in-before but PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations of poles complete all as specified and directed.
S & F LED street light fitting 45 watt having following specification. (a) Street light fittings shall composed to IP65/66. (b) Fixture should have pressure die cast aluminium body and modular lens on LED for better distribution of light. (c) Fixture having voltage band of 110 - 300 V AC & must have phase to phase protection for 8 hrs and auto cut after 300V. (d) Fixture having 5KV internal & 10KV external surge protection. (e) THD less than 10%. (f) Driver current 187 milli ampere. (g) System efficacy must be more than 110 lm/watt. (h) Driver should be equiped of short circuit and over voltage protection. (j) Manufacturer's name must be embossed on the fixture. (k) If any unserviceability of driver reported during 5 years of date of installation, contractor is liable to replace unserviceable driver free of cost to department. Make : Polycab Cat part No. PCGLS T1 45N or equivalent make as mentioned in group 1 of Appx "B"
S & F LED flood light fitting 60 watt having following specification. (a) Street light fittings shall composed to IP65/66. (b) Fixture should have pressure die cast aluminium body and modular lens on LED for better distribution of light. (c) Fixture having voltage band of 1100 - 3000 DC & must have phase to phase protection for 8 hrs and auto cut after 300V. (d) Fixture having 5KV internal & external surge protection. (e) THD less than 10%. (f) Driver current 187 milli ampere. (g) System efficacy must be more than 110 lm/watt. (h) Driver should be equiped of short circuit and over voltage protection. (j) Manufacture's name must be embossed on the fixture. (k) If any unserviceability of driver reported during 5 years of date of installation, contractor is liable to replace unserviceable driver free of cost to department. Make : Polycab Cat part No. PCGLS T1 60N or equivalent make as mentioned in group 1 of Appx "B"
S & F PVC looping box comprising of 04 Nos aluminimum bus bar mounted on insulator and including one No 10 Amps SP MCB including necessary fixing arrangement on pole complete all as specified and directed.
M & L for wiring for circuit from MCB box to street light including supply and fixing (with suitable clamp) of PVC conduit of size 20 mm dia on pole with FRLS PVC insulated single core multistranded unsheathed copper wire 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire in surfaces/recessed as required and complete all as directed.
Supply,install test and comprising of factory made powder coated cubical outdoor LT feeder pillar box of size 900 x 750 x 300 mm conforming to IP-65, CPRI approved complete weather proof and vermin proof and the shell of 3.15 mm thick MS sheet with partitions and switch enclosure doors of 2 mm MS sheet with minimum clearance of 750 mm and canopy made out of 3.15 mm thick MS sheet all as per IS shall be available inside for easy access and working condition fixed on angle iron frame 50 x 50 x 6mm. Mounted on brick masonry pillars with a clearance of atleast 0.45 mtrs above GL on 100mm thick appron of PCC 1:4:8 type D-2, provided 1.0 mtr all around with a slight outward slope to avoid stagnation of water etc all as specified and directed comprising of following :- (a) MCCB 63 Amp,4 pole 25 KA , 415 volt ICU 100% ICS with thermal based release - 01 Nos (b) Timer switch Analog outdoor type factory made powder coated all along internal and external surfaces, weather proof, dust and water proof with IP 55 protection, consisting of 01 No AC contactor 3 pahse 40 Amp capacity 10 KA, one digital Timer switch with 40 Amp cap TPN 10 KA having both auto manual and by pass system - 01 Nos mounted on existing panel with suitbale size clamps complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 10 Sq mm 4 core complete all as specified and directed.
Material & labour for galvanised iron tubes 40mm bore, light grade with & including all fittings fixed to wall/on poles, ceilings and or laid in floors/road crossing etc as in cable protection complete all as specified and directed.
M&L for earthing complete with galvanized iron or steel earth plate electrode of size 60 cm x 60 cm x 6.3 mm thick buried directely in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI Strip of size 32 x 6 mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh GI frame and 10 cm thick suitable reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40 mm graded stone aggregates complete including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in plate No 5 of SSR - 1991 part 1 PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit.
Supply and fixing concrete pole 9 mtr long of size 102 mm x 172 mm at top and 102mmx279 mm at bottom class 10 in truely vertically position including painting of pole up to 1.5 mtr height from PCC coping in black & white strip each of 30mm height with two coats of synthetic enamel paint and including dismantling/taking down of existing pole complete all as specified and directed (Excavation/ earthwork/PCC work shall be measured & paid separatelly)
Supply and fix steel tubular swaged poles type 410SP-31 (9.0 m long) swan neck type complete with CI base plate and finial and single swan neck, including foundation and coping including dismantling/taking down existing poles including painting of poles with two coats of synthetic enamel paint and making black & white strips of 30 cm each upto 1.5 mtr height from PCC coping complete all as specified and directed. Note : Old PCC poles replaced by steel tubular pole at site due to site restriction/requirement.
Supply fabricating and fixing GI bracket made out of galvanised pipe light grade 32 mm dia, 1.6 mtr long bent to shape for fixing of security light and complete all as specified and directed.
M & L for MS support clamps /angle iron fabricated from structural steel section in any shape or size bending hot or cold and drilling holes for bolts back plates nut bolt washers etc including painting with 2 coats of aluminium paint after a coat of primer all as specified by Engr-in-charge.
GULSHAN SINGH GHAI AND SON
AGGARWAL ENGINEERING CO
J.K & Company
UNITED ENGINEERING CORPORATION
COSMO BUILDERS
R D Bansal
CHOUDHARY AND SONS
M/S BALWINDER SINGH
SUNRISE ENGINEERS AND CONTRACTOR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .