Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L1 | Accepted-AOC AOC | |
| 2 | L2₹16.7 L+₹98,225 (6.24%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹20.3 L+₹4.5 L (28.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
30 Oct 2023, 6:00 pmClosed
GE (AF) Amla
GE (AF) Amla, Amla Depot, Distt- Betul, MP-460553
Repair / replacement/ cleaning of sewage line manholes storm water drain septic tank WC Pan gully traps soak pits etc at AFS Amla
2023_MES_616701_2
8552/E8 OF 2023-2024
Open Tender
Civil Works
Item Rate
335 days
GE (AF) Amla
As per Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹30,000
Yes
9 Dec 2023
5 Oct 2023
1 Nov 2023
5 Oct 2023
30 Oct 2023
12 Oct 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15cm thick (below or above ground level) complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation and mass concrete complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching and finishing the surfaces even and smooth using extra cement complete all as specified.
Demolition of reinforced cement concrete (ie manhole cover) in ground floors exc 15 cm thick (below or above ground leave) reinforcement cut as required to facilitate demolition complete all as specified and as directed.
M&L for provididng precast reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man hloes etc,) chullah noods, chajjas set in cement mortar 1:4 incuding necessary form work compete all as specified.
Demolition of brick work built in cement mortar (manhole soak well & septic tank etc.) including coping all as specified and as directed.
M&L Fly ash brick 75 kg/cmsq compressive strength. Modular size , is straight or curved on pian exc. 6 metre mean radius built in cement mortar 1:6 complete all as specified.
Demolition and Breaking up drain pipes of internal dia 150mm including PCC haunching, benching and bed concrete complete all as per Engr-In-Charge.
Demolition and Breaking up drain pipes of internal dia 200mm including PCC haunching benching and bed concrete complete all as per Engr-In-Charge.
M&L150 mm dia Reinforced cement concrete pipes, Class NP-3, laid in trenched and jointed with collar, complete all as specified.
M&L 200 mm dia Reinforced cement concrete pipes, Class NP-3, laid in trenched and jointed with collar, complete all as specified.
M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate, bed to drain pipes including packing under and haunching against sides of pipes for 150 mm bore after they are laid and tested complete all as directed.
M&L PCC 1:3:6 type C2 using 40mm graded stone aggregate, bed to drain pipes including packing under and haunching against sides of pipes for 200 mm bore after they are laid and tested complete all as directed.
Extra for forming fair finished drain or channels 30cm inner girth cement concrete using extra cement including forms, moulds, mitred / stopped ends etc complete all as specified Note :- inner girth only will be measured and paid.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in coping, hold fast and the like including weathering slightly rounded or chamfered angles and throting as directed with necessary formwork and finishing expsoed faces of concrete complete all as specified.
M&L 10 mm thick rendering in cement mortar 1:4 on fair faces of brick work finished even and smooth without using extra cement
M&L 15mm thick rendering in cement mortar 1:6, on fair faces of brick work finished even and fair complete all as specified
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundations etc, or for shafts, wells, mahnoles etc. not exc. 10 Sqm on plan and n.exc 1.5 metre in depth and getting out in soft/loose soil in foul condition complete all as specified and directed.
All as per item 19 but for depth exceeding 1.5 metre and not exceeding 3 metre and getting out in soft/loose soil in foul condition complete all as directed.
Returnning, filling in, including spreading, levelling, watering and well rammaing in layers not exceeding 25 cms thick in layers in slft/loose soil complete all as specdified and directed.
Removing excavated material exc 50m but not exc 250m deposited/spreaded where as in soil or material complete all as specified and as directed
M&L for mild steel TMT bars, 10mm dia and over, cut to length bent to shape required, including cranking bending spirally or hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specifid.
M&L for Mild Steel handles, rungs, brackets etc. and similar articals made out of mild steel round bars 10mm dia and over bent to shape required all as directed.
Taking down CI/AC/PVC pipes jointed in cement mortar etc and taking from eaves gutters, and rainwater pipes from walls (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) including all type of bends/branch pieces complete all as specified and as directed.
S & F in repairs 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F in repairs 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in wall complete all as specified and as directed.
S & F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in wall complete all as specified and as directed.
S & F in repairs 75mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
S & F in repairs 110mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
S & F in repairs 75mm bore PVC (SWR) bends of any radius, fixed with cement solvent, with oval access door complete all as specified and as directed.
S & F in repairs 110mm bore PVC (SWR) bends of any radius, fixed with cement solvent, with oval access door complete all as specified and as directed.
S & F in repairs 75mm bore PVC (SWR) branch piece, single (double Y) equal or unequal bends of any radius, fixed with cement solvent, with oval access door complete all as specified and as directed.
S & F in repairs 110mm bore PVC (SWR) branch piece, single (double Y) equal or unequal bends of any radius, fixed with cement solvent, with oval access door complete all as specified and as directed.
S & F in repairs 75mm bore PVC (SWR) junction single (single T) equal or unequal bends of any radius, fixed with cement solvent, with oval access door complete all as specified and as directed.
S & F in repairs 110mm bore PVC (SWR) junction single (single T) equal or unequal bends of any radius, fixed with cement solvent, with oval access door complete all as specified and as directed.
S & F in repairs 110mm bore PVC (SWR) vent cowl including taking down old unserviceable vent cowl complete all as specified and as directed.
S & F in repair 75mm dia PVC (SWR) nahani trap, plain with grating including jointing fixed with solvent cement to waste pipe complete all as specified and as directed.
M & L in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe anti syphonape pipe etc complete including making good to floor complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (Pedestal pattern), white (excluding fixing bolt, flushing cistern and flush pipe) but including seat cover of white colour complete all as specified and as directed.
PVC (SWR) 'P' trap bore 110mm/100mm complete all as specified and as directed.
PVC (SWR) 'S' trap bore 110mm/100mm complete all as specified and as directed.
Dismantling floor, hearth or wall tiling in cladding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises.
M&L for glazed ceramic colour tiles 350 x 250 x 7 mm/ 450 x 300 x 7mm thick in skirting/dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10mm thick rendering in CM(1:4) complete all as specified and as directed.
M&L for non skid colour ceramic tiles 300x300x7 mm thick, in floors etc set and jointed in neat cement slurry and pointed with white or coloured cement to match and laid over 15 mm thick screed bed (1:4) etc complete all as specified and as directed.
M & L for cutting out any type of vegetation complete from root grouted inside the wall specially in contact with sanitary pipe and pouring/grounting with hydrochloric acid (HCL) on left out rout if any including making good surfaces to match adjacent surfaces in PCC (1:2:4) type B-0 or 15mm thick plaster in CM (1:4) complete all as specified and as directed.
Tools & Labour for Cleaning of manhole of any size but depth not exc 1.00 mtr including lifting up & removing sludge, accumulated solid/semi solid sludge and any other foreign material with proper equipments and washing down completely with water for smooth functioning of sewage line, removing sludge obtained from cleaning to a distance not exceeding 50 mtr, filling the sludge in newly excavated pit, treating with bleaching powder and refilling top of pit with earth & removing balance earth to a distance n. exc 50 mtr complete all as specified and as directed. Note : Rate quoted shall deemed to be included cost of all excavation & earth work.
All as per Ser item No 48 above but depth exc 1.00 mtr & n.exc 1.50 mtr.
All as per Ser item No 48 above but depth exc 1.50 mtr & n.exc 2.00 mtr.
Tools & Labour for Cleaning of sewage pipe lines of any bore and removing the blockages by rodding using bamboo and gunny bags or by mechanical means, between the manholes, Nahani traps to gully traps, gully traps to manholes including vertical stack pipes (where ordered) , cleaning eye to gully trap and taking out all debris, sludge or any solid/ foreign materials from sewage line and flushing with water and testing after cleaning; including removing the debris outside MoD land in closed container complete all as specified and directed.
Tools & Labour for Cleaning of septic tank manually or mechanically by bailing out sewage and night soil/sludge etc. and removing the silt/sludges to a distance exceeding 50m but not exceeding 100 m from the septic tank and depositing in burying pit; including taking out manhole covers (RCC/CI) and refixing the same in position of any size complete all as specified and directed. Note: Excavation work for burying pit shall be measured and paid separately.
All as per item no 52 above but removing night soil/sludge/silt etc., outside MoD land in a closed container to a distance exceeding 1.5km but not exceeding 5km complete all as specified and directed.
Tools & Labour for cleaning of water closet (IWC/EWC) in foul condition upto 1st manhole from first floor/ground floor as the case may be by rodding and removing the debris including cutting of small vegetation where ever found at site complete as directed.
Tools & Labour for cleaning of Gully trap/ Nahani trap/ Floor trap in foul condition upto 1st manhole from first floor/ground floor as the case may be by rodding and removing the debris including cutting of small vegetation where ever found at site complete as directed. Notes : For Ser No 54 & 55 :- (a) Contractor/Rep of the contractor has to collect the complaints on daily basis from incharge of complaint cell. (b) The blockage of WC/Floor Trap/Gully trap are to be cleared on the same day of the receipt of complaint. (c) In case of non attaedence of complaints of WC blockage/Gully/Floor traps by the contractor on the same day, a penalty of Rs. 500/-per complaints per day will be recovered from the contractor.
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
M/s SHAKTI INFRASTRUCTURE
M/S J J ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .