| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | L1 | Accepted-AOC being lowest | |
| 2 | L2₹27.2 L+₹1.2 L (4.74%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹29.8 L+₹3.8 L (14.7%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
18 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Vijay Kumar Sharma
Garrison Engineer West 62 Station Road Agra Cantt
REPAIR TO STAIR CASE OF OFFICERS JCOS AND ORS MD ACCN AT UNDER AGE B R I OF GE WEST AGRA
2022_MES_512422_2
8012/871/E8
Open Tender
Civil Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹62,000
6 Jul 2022
10 May 2022
20 May 2022
10 May 2022
18 May 2022
10 May 2022
Amount
Demolition of brick work or stone/boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking down cement plaster of any description on brick, concrete, ceiling surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L Brick work with sub class 'B' old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L Brick work with sub class 'B' old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6 but except brick complete all as specified and directed.
M&L for rendering 15 mm thick plastering on concrete surfaces or brick walls in CM 1:6, finished the surface even & fair complete all as specified and directed.
M&L for rendering 10 mm thick plastering on concrete surfaces of ceiling in CM 1:3, finished the surface even & fair complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 mixed with water proofing compound as per manufecturer's instructions on other than fare faces of brick surfaces of walls & finishing the surface even & fair complete all as specified and directed. Note: WPC will be measured and paid separatly under respective item here-in-after
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of old decorated plastered or un-plastered surface of wall and applying one coat of white wash complete all as specified and as directed
M&L for preparation of old decorated plastered or un-plastered surface of ceiling and applying one coat of white wash complete all as specified and as directed
M&L for preparation of old plastered or unplastered surfaces of wall and applying one coat of cement base paint (snowcem) white or tinted complete all as specified and directed.
M&L for removing of trees of girth not exc 30 cm each from brick/concrete wall/ceiling, digging out roots, filling holes, leveling and finished the surface matching with adjoining surfaces complete all as specified and directed.
S&F mild steel joist channel angle or tee sections fixed independently without connected plates etc of grade fe-410-0 or fe 310-0.complete all as specified and directed.
M&L RCC 1:2:4 type B1 (using 20 mm graded stone aggregate), (Nominal Mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
S&F welded steel wire fabric of weight as approved by Engineer-in-charge (preferably not exc 4 Kg per Sqm) as in reinforcement to RCC members including all cutting, bending and binding complete all as specified and directed
S&F 5.0 cm thick sand stone slab in sunshades, chhajas, shelves, roof slabs etc n exc 2m in length, punched, dressed on face & along exposed edges, self faced on other side & set & pointed in CM 1:6 complete all as specified and directed.
M&L for cutting holes into or through brick wall built in cement mortar, superfacial area not exc 150Sqcm, making good in cement mortar 1:3 of cement concrete 1:2:4 type B1 as required complete all as specified and directed.
Taking down and refixing in same shutter after easing area exc 1Sqm and n 'exc 2 Sqm each shutter complete all as spd and directed.
M&L for roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing/ applying neat cement slurry @ 3.0 kg/ sqm, complete all as specified and directed.
M&L for machine cut kota stone slab 20-25 mm thick as in steps/stairs, laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone over 15mm thick screed bed in CM ( 1:6) including grinding and mirror polishing complete all as specified and directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking plateform and other similar situations including grinding and polishing complete all as specified and directed.
Taking down chowkhats or frames not exc 1.5 Sqm each with sutters(without taking off shutters from the frames) complete all as specified and directed.
S & F steel ventilators with top hung shutters including box type hinges, steel peg stay complete all as specified and directed
M&L for mild steel framed work as in doors or gates of angle or other section with guest plates rails, braces rail etc, confirming to Gde Fe-410-0 or Fe-310-0 (exculsive of steel sheeting or other covering), hanging, fastening and fixing complete including shop coat of red oxide complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter shunk) forming holes confirming to Fe-410-W(Gde-E-250) quality-B, without any attachment complete all as specified and directed.
S&F framed work such as grill, grating, guard bars etc with ends of bars shouldered or riveted or forged into spikes frame guard bars etc complete all as specified and directed.
M&L for 3mm thick ordinary quality sheet glass as n glass pane and glazing with oil putty , area not exc 0.5 Sqm in each pane complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of weather proof paint (APPEX Paint) as in band/strips in narrow width n.exc 15cm of approved shade, complete all as specified and directed.
M & L for preparation of old wooden surface of any discription not otherwise discribed over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for providing precast cement concrete louvers and jallies 1:2:4, type B0 (12.5mm graded aggregate) set in cement mortar 1:4, 25mm thick (measured solid), incluing all mouldings but excluding frame , complete all as specified and directed
M&L for preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old steel surfaces exceeding 10 cms width or girth and applying one coats of synthetic enamel paint, complete all as specified and directed.
M&L 75 mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in sub base, finished even and fair complete all as specified and directed.
M&L for chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick, with grey cement and pigments, set & jointed in neat cement slurry and pointed with grey cement & pigment in floors laid over and including 20 mm thick screed bed in CM 1:6 or bedding layer complete all as specified and directed.
Taking out / dismantling of mud or existing roof treatment of, any thickness, including plastering and leaping and tiling/ peding of any description including disposal of removed/demolished soil/material exc 1.5 km but n.exc 5 km, depositing out side the MD land or where directed, complete all as specified and directedspecified and directed.
M&L 40mm thick cement concrete type B1, 1:2:4 (using 20mm graded stone aggregate) as in padding of roof complate all as specified and directed
M & L for water proofing treatment of roof slab all as followes: - (a) Preparation of roof surfaces by brushing, cleaning and applying 15mm thick plaster in CM 1:4 mixed with water proofing compound as per manufacturer's instruction. (b) Applying one priming coat with bitumen primer @ 0.5 ltr/Sqm (c) Applying a hot blown bitumen grade 85/25 @ 1.2 Kg/sqm (d) Laying APP modified water proofing membrane weight not less than 3 Kg/Sqm applied bitumen coat. (e) Applying a tack coat of hot bitumen grade 85/25 @ 1.2 Kg/Sqm and spreading sand (confirming to Zone II) in dry condition over the bitumen @1.00 Kg/Sqm Note : WPC shall be measured and paid separately under respective item
M&L 18-20mm thick polymer modified mortar (CEMSCRED 'R') over polimer modified primer (CEMSCRED primer) on concrete as in ceiling, beams, chajjas & facia surface etc incl preparation of surface and incl chiseling extg surface as per manufactures instructions all as specified and directed.
M&L for brick tiles 40 mm thick laid over 15 mm thick screed bed in CM 1:3 and jointed in CM 1:3 with linced oil @ 5% by weight of cement, complete all as specified and directed. Note : After laying the brick tiles the work shall be cured with water by ponding for min 72 hours.
Supply only integral water proofing compound complete all as specified and directed.
M/S APOORVA CONSTRUCTION
CREATIVE CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .