Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC 158 ARATH BAZAR KASAULI 173204 HP | KASAULI | SOLAN | HIMACHAL PRADESH | 173204 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹30.6 L+₹3.2 L (11.6%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹40.7 L+₹13.3 L (48.3%)Rejected-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹45.0 L+₹17.6 L (64.0%)Rejected-AOC 3838 2ND FLOOR SECTOR 46 C CHANDIGARH UT 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | L4 | Rejected-AOC Other than lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Sept 2024, 6:00 pmClosed
Sh. Rahul Meena, IDSE, EE, Garrison Engineer, CEA
GARRISON ENGINEER KASAULI, DISTT SOLAN (HP) PIN 173204 PH 01792273107
REPAIR/ MAINT OF LT CABLES, LT PANELS, POLES, EARTHINGS AND REPAIR/ MAINT OF DISTRIBUTION PIPE LINES, PUMP SET, MOTORS, LT PANELS, STATERS, WATER METERS AND CONNECTED WORKS AT MES INSTALLATON SOLAN UNDER GE KASAULI
2024_MES_668786_1
GEK-66/2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
SOLAN
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE KASAULI
₹80,000
Yes
28 Jan 2025
31 Aug 2024
26 Sept 2024
31 Aug 2024
24 Sept 2024
16 Sept 2024
5 Sept 2024 - 12 Sept 2024
Amount
Schedule 'A' Section - I
Dismantling of old UNSV ACSR or AAC conductors, any type and size from the poles complete, all as specified and directed by Engr-in-Charge.
Supply and fixing new ACSR conductor including stringing on LT poles complete including aluminium binding wires, jumpering, bindings at insulators etc, complete, all as specified and directed by Engr-in-Charge.
Dismantling stay assembly complete.(demolition of concrete, etc. and excavation measured separately)
S&F Stay assembly complete with accessories as shown in electrical plate No-1 (loop type insulator, stay clamps, excavation and concrete measured separately) with stay rod 16mm dia, MS plate 6mm thick size 230x230mm, complete, all as specified and directed by Engr-in-Charge.
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified and directed.
Supplying & fixing in replacement of Cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated & directed and including one primer coat, one under coat and one finishing coat of paint, fixed in replacement including taking down existing one, complete, all as specified and directed.
Dismantling insulators any type, any size complete.
Supplying & fixing in replacement of pin insulator porcelain vitreous, white, brown & green incl. One galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height 65mm dia for 1100 volts grade, complete, all as specified and directed.
Supplying & fixing in replacement of shackle type porcelain, vitreous , white, brown or green insulator including galvanised mild steel straps washers insulator bolts, washer and nuts of size 100 mm height, 115mm dia for working pressure 1100 volts, complete, all as specified and directed.
S&F Loop type insulator, vitreous porcelain white , brown, green small size with overall dimensions 65mm x 90mm clearance of hole 16mm, complete, all as specified and directed.
S&F in replacement of Galvanized stay strand, size 7/2.24 mm, incl taking down the old unserviceable stay wire, complete, all as specified and directed.
Taking down street/security/Gate light/ Solar light fittings LED light fittings of any capacity or type from pole/wall after disconnection and connecting wires, carrying out to store yard for necessary repair/replacement of spares and fittings etc.,complete all as specified and directed.
Supply and fixing in replacement of LED post top lantern LED type 20 watt 230 watt volts AC outdoor type waterproof with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
Supply and fixing inreplacement of LED flood light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
Supplying & fixing in replacement of street light fitting GI bracket made out of 40mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall complete, all as specified and directed.
Supplying & fixing in replacement of clamps made out of 40x6 mm bending to shape, drilling holes for bolts suitable for fixing GI pipe bracket to steel pole, made in two halves, including nuts, bolts, washers and painting with two coats of aluminium paint over a coat of red oxide primer, complete, all as specified and directed.
S&F Steel water tubing, light grade, galvanised (ISI marked), 50 mm bore with all fittings, laid in trenches/ under roads or fixed to poles for passing cables for protection of cables, complete, all as specified and directed.
S&F Steel water tubing, light grade, galvanised (ISI marked), 40 mm bore with all fittings, laid in trenches/ under roads or fixed to poles for passing cables for protection of cables, complete, all as specified and directed.
S&F Steel water tubing, light grade, galvanised (ISI marked), 25 mm bore with all fittings, laid in trenches/ under roads or fixed to poles for passing cables for protection of cables, complete, all as specified and directed.
S&F Steel water tubing, light grade, galvanised (ISI marked), 20 mm bore with all fittings, laid in trenches/ under roads or fixed to poles for passing cables for protection of cables, complete, all as specified and directed.
Taking down carefully under ground cable of any size and making good to disturbed surface as per existing complete all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 25 Sqmm 3.5 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 25 Sqmm 4 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 16 Sqmm 4 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 10 Sqmm 2 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 50 Sqmm 3.5 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 70 Sqmm 3.5core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 120 Sqmm 3.5core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 630 Sqmm 3.5core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 185 Sqmm 3.5core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 300 Sqmm 3.5core, complete, all as specified and directed.
Streching of loose ACSR conductor including jumpering, binding,etc all as required in LT OH line, complete, all as directed. Note:- Disconnecting the existing security light or cable connection before stringing and reconnecting after stringing is included in the rates quoted.
Dismantling earth wire or copper conductor, service feeder or distributor span complete.
Supplying & fixing in replacement of GI wire as earth wire of size 4mm dia as required at site complete all specified and directed.
Supplying & fixing in replacement of connection/Junction box made out of 1.6mm thick MS sheet front openable, weather & vermin proof including painting two coats of synthetic enamel paint over a coat of red primer. Connection box shall be suitable for housing & including aluminium bus bar 25 Amps cap - 2 Nos, MCB SP 6 Amps- 01 No and having provision of cable hole in bottom for two to three cables of size 16 Sqmm 4 core armoured cable connection box shall be fitted on street light pole and fixing arrangements i.e. MS clamps etc deemed to be provided by the contractor, size of box - 200 x 150 x 100mm, complete, all as directed.
Supplying & fixing in replacement of double walled corrugated HDPE duct pipe of 63 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittinggs for cable protection complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable 4 sqmm 2 core PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable flat or circular complete all as specified and directed by Engr - in - Charge.
Dismantling steel poles/struts, any size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Steel tubular swaged poles complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified type 410 SP-31 9.0 mtr long duly painted with two coats of aluminium pait over a coat of red oxide primer complete, all as specified and directed.. Note- Excavation, earth work and PCC shall be measured and paid separately.
M&L for Painting of steel tubular pole 9.0 metre long, by applying two coat of aluminium paint after scraping / brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enameled paint (30 Cms each). Pole Nos will be written on pole by black paint in yellow circle of 150mm dia, complete, all as specified and directed. Note:- Only one coat will be applied at one time and payment at 50% of coated rate to be applied at the first time of first coat. Second coat is to be done more than 15 days after first coat.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
Earthing with Galvanised iron earth plate electrode 600mmx600mmx6mm thick burried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below GL, connected to GI earth lead wire 4 mm dia connected to earth plate electrode by means of GI nuts, bolts & washers earth wire protected with 15 mm bore light grade ISI marked GI pipe not less than 7.5 metre long all as shown in electrical plate No 3 of MES Schedule Part I, with & including; PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1 reinforced with welded steel wire fabric not less than 4 Kg per Sq M, watering arrangements with 20 mm bore GI medium grade pipe ISI marked , GI funnel with GI mesh, filling with mixture of common salt & charcoal, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete all as specified.
Supply and fix in replacement of Sheet metal enclosure bus bar including fiiting on wall/pole including and making the connection with MCCB 4 Pole 100 Amps 16 KA, 415 volts , 50 Hz ,thimble/lugs, aslo including all nuts bolts required for fixing all as specified and directed by Engineer - in - Charge.
Supply and fix in replacement of adjustable thermal & adjustable magnetic type MCCB 4 pole 400 Amps 36 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of adjustable thermal & adjustable magnetic type MCCB 4 pole 250 Amps 36 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of adjustable thermal & adjustable magnetic type MCCB 4 pole 500 Amps 36 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of adjustable thermal & adjustable magnetic type MCCB 4 pole 160 Amps 36 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of adjustable thermal & adjustable magnetic type MCCB 4 pole 100 Amps 16 KA capacity AC 415 v complete all as specified and directed.
M&L L.T. lightning arresters for outdoor use, non-liner resistor type, horn gap and choking coil, maximum working pressure 1100 volts including dismantling and taking down old arrestors complete all as directed
M&L PVC spacer suitable for 5 wire LTOH line including taking down of old one. .
M&L PVC spacer suitable for 6 wire LTOH line including taking down of old one. .
Pruning of tree branches and making clear LT line to the minimum distace of 1.8 mtrs all arround
For 3/4 conductors
For 5/6 conductors
Supply and fix in replacement of digital time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure. complete all as specified.
Taking out existing earthings and M&L for replacement of 'Earthing complete with and including galvanised steel earth plate electrode 60 cmx 60cm x 6 mm thick surrounded by mixture of charcoal and salt in alternate layers , buried directly in ground vertically in a pit of depth not less than 2.25 meter deep below ground level with top as of the plate at a depth of not less than 1.5 mtrs below normal ground level connected to equipment by using GI strips of size 32x6 mm as earthing lead by means of bolts ,nuts, check nuts and washers of galvanised iron or steel earth wire protected by galvanised steel pipe 40 mm bore (light grade) and 20mm bore "Light' grade GI watering pipe connected to main switch or main control board or GOD or lightening arrester all as shown in electrical plate No. 3 of SSR - 2009(Pt I) & including necessary excavation and earth work. The rate also include charcoal and salt in alternate layers, 20 mm bore GI pipe (Light grade ) for watering , protection pipe funnel, wire mesh , PCC 1:2:4 type B1 chamber in cement concrete ,50 mm thick precast RCC M-25 ( Design mix) cover duly reinforced with XPM (weight not less than 3 kg /sqm ) and CI frame etc , and including provision of test point , connecting to test point and testing on completion etc, complete all as specified. NOTE : The unit rate include earthing lead and protection pipe upto 7.5 metre from top of earth plate
Supply & fixing Glavanised iron strip 32x6mm buried in ground.
Taking down old unsv solar light and Supply and fix in replacement LED Solar Street Light 15 watt is made with High Efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & is specially progrmmed to automatically control the dimming and brightness of light, which increases the backup time complete all as specified and directed by Engr- in charge.
Dismantling old unsv and Supply and fixing of shock treatment chart as per E-in-C's pattern size 2 feet x 4 feet aluminium board with alluminium frame & glass with houging aggrements all as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat/cold Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size185 to 240 sqmm,Indoor/Outdoor type including taking down of old one.
Supply and laying Sub Class 'B' common burnt bricks, old size, designated 75, laid dry, flat with width equal to length of brick & with gaps between the adjucent bricks not exceeding 10mm as cover laid over the cable to give mechanical protection to under ground cable, complete, all as specified and directed.
Supply and lay Dry sand cushioning to under ground electric cable on layer of 8cm thick before laying the cable and second layer of 15cm thick after laying the cable, complete, all as specified in clause 19.75 of M.E.S Schedule Part-I (2009) and directed.
M & Laying cement concrete for foundation fillings and mass conctere type D2 1:4:8 ( 40 mm graded aggregate ) complete all as specified and directed.
M&L for PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of pole, stay incl frame work where reqd all as specefied and directed.
M & Laying cement concrete for copying of poles type B1, 1:2:4 (20 mm graded crused stone aggregate) ,smooth finishing without using extra cement complete all as specified and directed.
Disconnecting the electrical connections of motor, water supply to the Pump and taking out pump after disconnecting both motor and pump mechanically 10 to 15 HP capacity capacity - 45 Cum at 35 metres head installed at Water Pump House and Back Solan and transporting the same to an authorized workshop for following repairs :-
S&F Shaft with keys made out of steel 410 grade for Srl Item No 69.00
S&F Shaft sleeve with nuts made out of stainless steel 410 grade for Srl Item No 69.00
S&F Set of pins and Gaskets made out of Mild Steel for Srl Item No 69.00
S&F Coupling set made out of Cast Iron including bolts, nuts, washers & rubber bushes for Srl Item No 69.00
S&F Gland box made out of Cast Iron including gland box studs with nuts and washers for Srl Item No 69.00
S&F Gland packing made out of Gr. Cotton for Srl Item No 69.00
S&F Impeller made out of cast Iron duly balanced by means of precision lathe machine for Srl Item No 69.00
S&F Driving End bearing for Srl Item No 69.00
S&F Non Driving End bearing for Srl Item No 69.00
M/L for applying two coats painting of PUMP with super enamelled paint on steel with black colour applying two coats by spray method complete all as specified and directed.
Disconnecting the electrical and mechanical connections of motor, and taking out motor,15 HP capacity at Solan Pump House. Transporting the same to an authorized workshop for following repairs:-(a) Dismantling burnt AC 3 Phase, 50 Hz, motor, 15 HP taking out all coils and re-winding the motor complete with same gauge of wire and same nos of turns. Heating, Baking and varnishing the winding complete. Re-assembling the motor and fixing back in position all as directed by Engr-in-Charge and recommended by the manufacturer.
All as per item No 70.00 here-in-before but for, 10 HP capacity .
M/L for applying two coats painting of Motor with super enamelled paint on steel with grey colour applying two coats by spray method complete all as specified and directed.
Supply / laid PVC insulated unsheathed multistranded HRFR 3 x single core ( R,Y,B) copper conductor 1100 volts grade of size 16 sqmm passing through existing PVC/ERW conduit from starter upto pump fixed with required size of copper lugs complete all as specified and directed by Engr-in-Charge.( Note- 3 single core wire of 16 sqmm ( colour coding RYB) will be measured as one length of 1 RM)
S&F in replacement of Water meter 100 mm nominal bore conforming to IS:2373-1981 having CI casing bronze body and SS/Alloy/Bronze gear having dial duly marked with litres or kilolitres in boldface, thread/flanged end type with provision of strainer out side the meter complete all as specified and as directed and as directed and directed by Engr-in-Charge.
S&F in replacement of Foot Valve conforming to IS-4038 flanged ISI marked completed with nut, bolts, washers etc including taking out old existing u/s foot valve of 100 mm dia and directed by Engr-in-Charge.
S&F Push Button 22.5 mm with push knob flush type having 1 NO & 1 NC illuminated type for putting on / off the starter suitable as per site requirement and directed by Engr-in-Charge.
S&F LED indicating light surge and low voltage protected 220 / 240 Volts AC, Colour R/Y/G/A suitable as per site requirement and directed by Engr-in-Charge.
S&F electronic star delta Timer ( 1 to100 sec) DQR 415/240V, 110V : AC complete suitable as per site requirement and directed by Engr-in-Charge.
S&F in replacement Star delta starter for 10-15 HP motor pump 415 AC complete suitable as per site requirement and directed by Engr-in-Charge.
Supply & fixing in repairs die cast resin CT, copper wound Class 1, for digital Amp Meters. Ratio of CT- all as directed by Engineer- in-Charge. As per existing Make & Model.
Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter 15 HP 3 pole, 32 Amps for AC 3 rating 415 volts, 15 kW 50 Hz supply including control coil, 1NO+1NC, contact springs, spring retainers and arc runners complete.
Taking out old & unserviceable power contactor and Supply & fix power contactor for S/D starter 10 HP ,3 pole,12 Amps for AC 3 rating 415 volts, 5.5 KW , 50 Hz supply including control coil, 1NO+1NC, contact springs, spring retainers and arc runners complete.
Supply & fixing in repairs fixed thermal & fixed magnetic type MCCB 4 Pole 63 amps16 KA capacity 415 volts AC. As per existing Make & Model.
Supply & fixing in repairs fixed thermal & fixed magnetic type MCCB 3 Pole 32 amps 16 KA capacity 415 volts AC. As per existing Make & Model.
Taking out existing earthings and M&L for replacement of chemical earthing (Pipe in pipe technology) Two B class IS mild steel pipe, one inside the other, hot dip galvanised with 100 micron coating outside and about 300 micron coating inside filled with high conductive and corrosion Resistant Crystalline Mixture inside and Backfill compound around the outer electrode) outer electrode dia 72 to 80mm and inner electrode dia 35 to 40 mm both 10' long, incldg making earth pit of size 4' x 4' and 11' deep fill the entire pit with black cotton soil or normal soil, pour enough water so that pit is full with water, leave it for three days so that soil soaks up the water, the soil level has goes down, again top up the pit with soil & fill the water. After two or three days when the pit is sturdy and ready for earthing purpose, install the earthing electrode as per installation method as below:- (a) Mix backfill compound evenly with soil. (b) Remove plastic sleeve carefully from electrode. (c) Place naked electrode at centre of pit. (d) Start refilling empty space around electrode with backfill compound in layers. (e) Pour some water and poke the pit with a long wooden rod to allow trapped air to escape. (f) Gradually continue refilling process till electrode is buried in the pit up to the green patch painted on the top portion of electrode. (g) Ensure that pit is not watery (h) Pack electrode with compound nicely and tightly, so that it stands firmly in pit. (j) Pour a few buckets of water around pit. (k) Pour a few buckets of water around in the pit everday for 10-15 days for system to set. (l) Connect the earth electrode with equipments by 25mm x 3mm aluminium strip. (m) Earthing test point terminal block made of gun metal size 150x100x50 mm drilled and screwed including 4 Nos 8 mm dia 40 mm long hexagonal head bolts and washers duly fixed on walls with fasteners 4 Nos. Note : (a) Earth resistance shall not be more than 5 Ohm. (b) Aluminium strip for connections shall be measured and paid separately.
Taking out old unsv and Supplying, fixing and testing of cast steel Sluice valve PN1.6 as per IS-14846, body, dome, wedge-CI IS:210, rings-bronze IS:318, Spindal-SS IS:6603, Gland Paking greasy jute packing, fasteners-CS, Gasket- Natural rubber, nominal size DN-150 mm, both ends flanged in existing line, after removal of old unserviceable sluice valve without damaging to existing pipe line complete all as specified and directed by Engr-in-charge. Note : Suitable size flanges for existing pipe line, Joints and jointing materials shall be included under this item.
All as per serial item No. 87.00 here-in-before but nominal size DN-100 mm -ditto-.
All as per serial item No. 87.00 here-in-before but nominal size DN-80 mm -ditto-.
S&F Cast iron Non Return valve W/O by pass arangement , Swing type, of Size 100 mm bore, confirming to IS 5312, flanged ends with nuts bolts, washers complete including taking down of old one as directed by Engr-in-Charge .
S&F Cast iron Non Return valve W/O by pass arangement , Swing type, of Size 150 mm bore, confirming to IS 5312, flanged ends with nuts bolts, washers complete including taking down of old one as directed by Engr-in-Charge .
Supply and fix Cast Iron Air Release Valves with two air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia as directed by Engr-in-Charge .
Supply and fix Cast Iron Air Release Valves with two air Outlets, conforming to IS 14845 of size 150 mm dia bore and fixing up in Cast Iron Water supply mains of size 150 mm dia as directed by Engr-in-Charge .
Construction of brick masonary pit of size 60 x 60 x 60cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawing No. STD- 1258, sheet 1/1. (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office of GE Kasauli.
Construction of brick masonary pit of size 90 x 90 x 90 cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawing No. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office of GE Kasauli.
Construction of brick masonary pit of size 120 x 120 x 120 cm internal size with MS sheet 3 mm thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawing No. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office of GE Kasauli.
Supply of calcium hypo chloride, 65%-70% chlorine content, high strength granular disinfectant for treatment of drinking water complete all as specified and qty as per requirement and as directed by Engr-in-Charge.
S&F in replacement of Bronze gate valve for 15mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, complete all as specified and directed.
All as per serial item No. 98.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 98.00 here-in-before but of size 25mm bore -ditto-.
All as per serial item No. 98.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 98.00 here-in-before but of size 50mm bore -ditto-.
Taking out unserviceable/defective/damaged/blockage GI pipe 15 mm bore steel water tubing, including fitting and removing away all unserviceable pipe from site, complete all as specified and as directed. (Note: Exacavation and earhwork shall be measured and paid for separately.)
All as per serial item No. 103.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 103.00 here-in-before but of size 25 mm bore -ditto-.
All as per serial item No. 103.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 103.00 here-in-before but of size 50mm bore -ditto-.
All as per serial item No. 103.00 here-in-before but of size 80mm bore -ditto-.
All as per serial item No. 103.00 here-in-before but of size 100mm bore -ditto-.
All as per serial item No. 103.00 here-in-before but of size 150mm bore -ditto-.
S&F steel water tubing medium grade, galvanised, ISI Marked conforming to IS 1239 Part-I 2004, 15mm bore with and including all fittings such as bends , elbows,tees, short length , socket, union, check nuts, nipples, flanges and weldings etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed.
All as per serial item No. 111.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 111.00 here-in-before but of size 25mm bore -ditto-.
All as per serial item No. 111.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 111.00 here-in-before but of size 50mm bore -ditto-.
All as per serial item No. 111.00 here-in-before but of size 80mm bore -ditto-.
All as per serial item No. 111.00 here-in-before but of size 100mm bore -ditto-.
All as per serial item No. 111.00 here-in-before but of size 150mm bore -ditto-.
Cleaning of RCC OH Tank of capacity 50000 Gln on staging 20 feet height throughly removing mud, grits etc. from the sump by following method:- (a) Removing all dirt,mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars/floor removing mud, grits & deposits etc properly. (d) Repair/ Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(MS/GI Pipe if reqd, it will be measured and paid separately).(e) Dry washed walls, coating with a one coat of white cement in side and out side two coat of white wash with lime the whole surface of walls/pillars and floor/roof of sump.
Cleaning of RCC UG sump of capacity 100000 Gln on staging 20 feet height throughly removing mud, grits etc. from the sump by following method:- (a) Removing all dirt,mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars/floor removing mud, grits & deposits etc properly. (d) Repair/ Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(MS/GI Pipe if reqd, it will be measured and paid separately).(e) Dry washed walls, coating with a one coat of white cement in side and out side two coat of white wash with lime the whole surface of walls/pillars and floor/roof of sump.
Cleaning of RCC UG sump of capacity 30000 Gln on staging 20 feet height throughly removing mud, grits etc. from the sump by following method:- (a) Removing all dirt,mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars/floor removing mud, grits & deposits etc properly. (d) Repair/ Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(MS/GI Pipe if reqd, it will be measured and paid separately).(e) Dry washed walls, coating with a one coat of white cement in side and out side two coat of white wash with lime the whole surface of walls/pillars and floor/roof of sump.
Cleaning of RCC Semi UG sump of capacity 10000 Gln on staging 10 feet height throughly removing mud, grits etc. from the sump by following method:- (a) Removing all dirt,mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars/floor removing mud, grits & deposits etc properly. (d) Repair/ Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(MS/GI Pipe if reqd, it will be measured and paid separately).(e) Dry washed walls, coating with a one coat of white cement in side and out side two coat of white wash with lime the whole surface of walls/pillars and floor/roof of sump.
Cleaning of RCC Semi UG sump of capacity 5000 Gln on staging 10 feet height throughly removing mud, grits etc. from the sump by following method:- (a) Removing all dirt,mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars/floor removing mud, grits & deposits etc properly. (d) Repair/ Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(MS/GI Pipe if reqd, it will be measured and paid separately).(e) Dry washed walls, coating with a one coat of white cement in side and out side two coat of white wash with lime the whole surface of walls/pillars and floor/roof of sump.
Taking out old & unserviceable chlorination dosing pump and Supply & fixing of fully automatic Sodium Hypo chlorite dosing equipment with following accessories with specification incl. piping & wiring all as specified & directed by Engr-in-charge. (a).Dosing pump having maximum flow rate 6L PH @ 4 Bar ,230 V,50 Hz AC Single phase, dosing rate adjusment manually,level switch interlock inbuilt on the pump, Diaphragm Electronic type 02 Nos one working & 01 standby (b). Dosing mixing tank cylindrical flat bottom LDPE storage capacity 100 ltrs. - 01 Nos. (c). Dosing Tank mixer - mixing Motor made out of SS-304 with 0.25 HP single phase motor type Inline Helical/worn type Gearbox & Motor - 01 Nos. (d). Skid MSEP - Made oput of MS duly powder coated Entire Plant ON - 01 Nos. (e).Control Panel - As Per VP Design - 01 Nos. (f). Pressure Switch - Made out of CI/ SS Automatic ON/OFF Operation type LPS/HPS - 01 Nos.
Supply only water quality Test Kit for Bromine,Chlorine and PH level for daily testing of quality of Water at various supply point of Solan.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m indepth; for foundation, etc. orfor shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc1.5 m in depth and getting out hard dense soil as complete all as specified and directed .
Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed.
Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed.
Amount of credit of Rs. 154171.10 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
Rajesh Agencies (BID ID -3110763)
R B TRADERS (BID ID -3111286)
naina devi constructions (BID ID -3110317)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .